Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Photolytic Degradation of Water‐Soluble Organic Carbon in Snowmelts: Changes in Molecular Characteristics, Brown Carbon Chromophores, and Radiative Effects

Abstract Water‐soluble organic carbon (WSOC) deposited in ambient snowpack play key roles in regional carbon cycle and surface energy budget, but the impacts of photo‐induced processes on its optical and chemical properties are poorly understood yet. In this study, melted samples of the seasonal snow collected from northern Xinjiang, northwestern China, were exposed to ultraviolet (UV) radiation to investigate the photolytic transformations of WSOC. Molecular characteristics and chemical composition of WSOC and its brown carbon (BrC) constituents were investigated using high‐performance liquid chromatography interfaced with a photodiode array detector and a high‐resolution mass spectrometer. Upon illumination, formation of nitrogen‐ and sulfur‐containing species with high molecular weight was observed in snow samples influenced by soil‐ and plant‐derived organics. In contrast, the representative sample collected from remote region showed the lowest molecular diversity and photolytic reactivity among all samples, in which no identified BrC chromophores decomposed upon illumination. Approximately 65% of chromophores in urban samples endured UV irradiation. However, most of BrC composed of phenolic/lignin‐derived compounds and flavonoids disappeared in the illuminated samples containing WSOC from soil‐ and plant‐related sources. Effects of the photochemical degradation of WSOC on the potential modulation of snow albedo were estimated. Apparent half‐lives of WSOC estimated as albedo reduction in 300–400 nm indicated 0.1–0.4 atmospheric equivalent days, which are shorter than typical photolysis half‐lives of ambient biomass smoke aerosol. This study provides new insights into the roles of WSOC in snow photochemistry and snow surface energy balance.

Meteorology & Atmospheric Sciences↗

Cross-Scale Molecular Analysis of Chemical Heterogeneity in Shale Rocks

The organic and mineralogical heterogeneity in shale at micrometer and nanometer spatial scales contributes to the quality of gas reserves, gas flow mechanisms and gas production. Here, we demonstrate two molecular imaging approaches based on infrared spectroscopy to obtain mineral and kerogen information at these mesoscale spatial resolutions in large-sized shale rock samples. The first method is a modified microscopic attenuated total reflectance measurement that utilizes a large germanium hemisphere combined with a focal plane array detector to rapidly capture chemical images of shale rock surfaces spanning hundreds of micrometers with micrometer spatial resolution. The second method, synchrotron infrared nano-spectroscopy, utilizes a metallic atomic force microscope tip to obtain chemical images of micrometer dimensions but with nanometer spatial resolution. This chemically "deconvoluted" imaging at the nano-pore scale is then used to build a machine learning model to generate a molecular distribution map across scales with a spatial span of 1000 times, which enables high-throughput geochemical characterization in greater details across the nano-pore and micro-grain scales and allows us to identify co-localization of mineral phases with chemically distinct organics and even with gas phase sorbents. Finally, this characterization is fundamental to understand mineral and organic compositions affecting the behavior of shales.

04 OIL SHALES AND TAR SANDS↗

Spatial Resolution Versus Data Acquisition Efficiency in Mapping an Inhomogeneous System with Species Diffusion

Traditionally, spatially-resolved photoluminescence (PL) has been performed using a point-by-point scan mode with both excitation and detection occurring at the same spatial location. But with the availability of high quality detector arrays like CCDs, an imaging mode has become popular for performing spatially-resolved PL. By illuminating the entire area of interest and collecting the data simultaneously from all spatial locations, the measurement efficiency can be greatly improved. However, this new approach has proceeded under the implicit assumption of comparable spatial resolution. We show here that when carrier diffusion is present, the spatial resolution can actually differ substantially between the two modes, with the less efficient scan mode being far superior. We apply both techniques in investigation of defects in a GaAs epilayer – where isolated singlet and doublet dislocations can be identified. A superposition principle is developed for solving the diffusion equation to extract the intrinsic carrier diffusion length, which can be applied to a system with arbitrarily distributed defects. The understanding derived from this work is significant for a broad range of problems in physics and beyond (for instance biology) – whenever the dynamics of generation, diffusion, and annihilation of species can be probed with either measurement mode.

14 SOLAR ENERGY↗

Use of an ambient ionization flowing atmospheric-pressure afterglow source for elemental analysis through hydride generation

An ambient mass spectrometry ionization source based on an atmospheric-pressure flowing afterglow has been coupled to a Mattauch-Herzog mass spectrograph capable of simultaneous acquisition of a range of mass-to-charge values by means of a Faraday-strip array detector. The flowing afterglow was used as the ionization pathway for species produced by hydride generation. This ionization strategy circumvents problems, such as discharge instabilities or memory effects, induced by introducing the gaseous sample into the discharge. The generated spectra show both atomic and molecular peaks; calibration curves were calculated for both peak types with limits of detection for arsenic below 10 ppb. This study demonstrates the ability to use an ambient mass spectrometry source, commonly used for molecular analyses, for the detection of gas phase elemental species with the possibilty of performing speciation by coupling with a separation technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Early Results from the Q{sub weak} Experiment

A subset of results from the recently completed Jefferson Lab Q{sub weak} experiment are reported. This experiment, sensitive to physics beyond the Standard Model, exploits the small parity-violating asymmetry in elastic {vector e}p scattering to provide the first determination of the protons weak charge Q{sub w}{sup p}. The experiment employed a 180 {micro}A longitudinally polarized 1.16 GeV electron beam on a 35 cm long liquid hydrogen target. Scattered electrons corresponding to Q{sup 2} of 0.025 GeV{sup 2} were detected in eight Cerenkov detectors arrayed symmetrically around the beam axis. The goals of the experiment were to provide a measure of Q{sub w}{sup p} to 4.2 percent (combined statistical and systematic error), which implies a measure of sin2(thetaw) at the level of 0.3 percent, and to help constrain the vector weak quark charges C{sub 1u} and C{sub 1d}. The experimental method is described, with particular focus on the challenges associated with the worlds highest power LH{sub 2} target. The new constraints on C{sub 1u} and C{sub 1d} provided by the subset of the experiments data analyzed to date will also be shown, together with the extracted weak charge of the neutron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current and Future Research at DANCE

An overview of the current experimental program on measurements of neutron capture and neutron induced fission at the Detector for Advanced Neutron Capture Experiments (DANCE) is presented. Three major projects are currently under way: 1) high precision measurements of neutron capture cross sections on Uranium isotopes, 2) research aimed at studies of the short-lived actinide isomer production in neutron capture on 235 U and 3) measurements of correlated data of fission observables. New projects include developments of auxiliary detectors to improve the capability of DANCE. We are building a compact, segmented NEUtron detector Array at DANCE (NEUANCE), which will be installed in the central cavity of the DANCE array. It will thus provide experimental information on prompt fission neutrons in coincidence with the prompt fission gamma-rays measured by 160 BaF 2 crystals of DANCE. Additionally, unique correlated data will be obtained for neutron capture and neutron-induced fission using the DANCE-NEUANCE experimental set up in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A simple technique to estimate the fully time-resolved x-ray diameter of a z pinch

Occultations are routinely used to derive information about astronomical objects. Here an occultation scheme is used to derive a fully time-resolved estimate of the x-ray emitting diameter of a z pinch. By using different filtrations on the sensors, one could for example, distinguish the size of the K-line emitting region compared to the higher energy K-continuum emitting volume. Or with suitable apertures and detector arrays, the pinch diameter could be axially and temporally resolved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Multichannel Time-of-Flight Technique for Plasma Potential Profile Measurements by Heavy Ion Beam Diagnostic on the Tokamak ISTTOK

This contribution summarizes the current implementation of the time-of-flight (TOF) energy analysis for plasma potential measurements by the heavy ion beam diagnostic (HIBD) on the tokamak ISTTOK. The technique is described in detail. The results of the measurements of the ISTTOK plasma potential radial profile are presented. It is proved that the TOF energy analysis is suitable for simultaneous multichannel detection using a multiple cell array detector. With the aim of improving the signal-to-noise ratio of the diagnostic, the channeltrons have recently been installed on the 'start' and 'stop' detectors and preliminary results are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Ion Doppler Spectrometer Instrument for Ion Temperature and Flow Measurements on SSPX

A high-resolution ion Doppler spectrometer has been installed on the Sustained Spheromak Plasma Experiment to measure ion temperatures and plasma flow. The system is composed of a 1 meter focal length Czerny-Turner spectrometer with diffraction grating line density of 2400 lines/mm, which allows for first order spectra between 300 and 600 nm. A 16-channel photomultiplier tube detection assembly combined with output coupling optics provides a spectral resolution of 0.0126 nm per channel. We calculate in some detail the mapping of curved slit images onto the linear detector array elements. This is important in determining wavelength resolution and setting the optimum vertical extent of the slit. Also, because of the small wavelength window of the IDS, a miniature fiber optic survey spectrometer sensitive to a wavelength range 200 to 1100 nm and having resolution 0.2 nm, is used to obtain a time-integrated spectrum for each shot to verify specific impurity line radiation. Several measurements validate the systems operation. Doppler broadening of C III 464.72 nm line in the plasma shows time-resolved ion temperatures up to 250 eV for hydrogen discharges, which is consistent with neutral particle energy analyzer measurements. Flow measurements show a sub-Alfvenic plasma flow ranging from 5 to 45 km/s for helium discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the shell structure near {sup 54}Ca and {sup 100}Sn

In this contribution results will be reported from two recent experiments at the GSI Fragmentseparator (FRS). The first experiment is using one-nucleon knockout with relativistic fragments from a 500 AMeV {sup 86}Kr primary beam to probe the single-particle structure in {sup 49}Ca and {sup 55}Ti. From the one-neutron knockout in the neutron-rich nuclei {sup 50}Ca and the N = 34 nucleus {sup 56}Ti cross sections and momentum distributions were deduced allowing the determination of angular momentum values and spectroscopic factors for individual states.In the second experiment decay spectroscopy of {sup 100}Sn and nuclei in its vicinity was performed. The nuclei of interest were produced using the fragmentation of a 1 AGeV {sup 124}Xe primary beam. The RISING gamma-ray detector array was used in close geometry to detect gamma-decay following isomeric as well as beta decays. Aside from the production of more that 200 {sup 100}Sn nuclei, several new isotopes and isomers were discovered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Step Cascades In {sup 63}Ni

Multi-step cascades from the {sup 62}Ni(n{sub cold},{gamma}) {sup 63}Ni reaction were studied via a {gamma}-ray spectroscopy method. With a {gamma}-ray detector array multiple {gamma}-ray coincident events were accumulated. By selecting full cascade events from the capture state to the ground state, we have developed a new computer-based level construction method and it is applied to excited level assignment in {sup 63}Ni.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intensity-Modulated Advanced X-ray Source (IMAXS) for Homeland Security Applications

X-ray cargo inspection systems for the detection and verification of threats and contraband require high x-ray energy and high x-ray intensity to penetrate dense cargo. On the other hand, low intensity is desirable to minimize the radiation footprint. A collaboration between HESCO/PTSE Inc., Schonberg Research Corporation and Rapiscan Laboratories, Inc. has been formed in order to design and build an Intensity-Modulated Advanced X-ray Source (IMAXS). Such a source would allow cargo inspection systems to achieve up to two inches greater imaging penetration capability, while retaining the same average radiation footprint as present fixed-intensity sources. Alternatively, the same penetration capability can be obtained as with conventional sources with a reduction of the average radiation footprint by about a factor of three. The key idea is to change the intensity of the source for each x-ray pulse based on the signal strengths in the inspection system detector array during the previous pulse. In this paper we describe methods to accomplish pulse-to-pulse intensity modulation in both S-band (2998 MHz) and X-band (9303 MHz) linac sources, with diode or triode (gridded) electron guns. The feasibility of these methods has been demonstrated. Additionally, we describe a study of a shielding design that would allow a 6 MV X-band source to be used in mobile applications.

07 ISOTOPE AND RADIATION SOURCES↗

Heavy ion beam probe coordinate mapping and calibration at WEGA stellarator

The heavy ion beam probe (HIBP) is an established nonperturbing diagnostic for high spatially and temporary resolved measurements of magnetically confined plasma parameters such as potential, density, and temperature. These quantities can be determined from the change in the ion beam parameters (charge, intensity, and trajectory) passing through a plasma volume due to collisions with electrons and interaction with the confining magnetic field. One of the problems that should be solved during HIBP installation and tuning is the coordinate matching. Conventionally the coordinate mapping of the HIBP measurement point is provided by ray tracing calculations of the ion beam in the magnetic field. However, it is very difficult to include all physical effects and uncertainties in the model. Thus, the result of the calculations may differ from the real probing position. In order to improve the mapping precision of the HIBP installed at the WEGA stellarator an additional measurement of the beam position is provided using a primary beam detector array inside the vacuum vessel. This allows comparing the measured and calculated ion beam positions in order to prove the calculated coordinate precision and include adjustments in the calculation code if necessary. The principle and the results of this calibration, which is not specific to WEGA but could be adapted to other experiments as well, are presented in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Band Structures in Aapprox110 Neutron-Rich Nuclei

The high spin states of neutron-rich nuclei in Aapprox110 region have been carefully investigated by measuring prompt gamma-gamma-gamma coincident measurements populated in the spontaneous fission of {sup 252}Cf with the Gammasphere detector array. Many new collective bands have been discovered. In this proceeding paper, we introduce some interesting new band structures recently observed by our cooperative groups, that is, the one-phonon- and two-phonon gamma-vibrational bands in odd-A {sup 103}Nb, {sup 105}Mo and {sup 107}Tc, the chiral doublet bands in even-even {sup 106}Mo, {sup 110}Ru and {sup 112}Ru, and the pseudospin partner bands with in {sup 108}Tc. The characteristics of these band structures have been discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of electron cyclotron emission imaging instrument on the DIII-D tokamak and first data

A new electron cyclotron emission imaging diagnostic has been commissioned on the DIII-D tokamak. Dual detector arrays provide simultaneous two-dimensional images of T{sub e} fluctuations over radially distinct and reconfigurable regions, each with both vertical and radial zoom capability. A total of 320 (20 verticalx16 radial) channels are available. First data from this diagnostic demonstrate the acquisition of coherent electron temperature fluctuations as low as 0.1% with excellent clarity and spatial resolution. Details of the diagnostic features and capabilities are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Maia Spectroscopy Detector System: Engineering for Integrated Pulse Capture, Low-Latency Scanning and Real-Time Processing

The Maia detector system is engineered for energy dispersive x-ray fluorescence spectroscopy and elemental imaging at photon rates exceeding 10{sup 7}/s, integrated scanning of samples for pixel transit times as small as 50 {micro}s and high definition images of 10{sup 8} pixels and real-time processing of detected events for spectral deconvolution and online display of pure elemental images. The system developed by CSIRO and BNL combines a planar silicon 384 detector array, application-specific integrated circuits for pulse shaping and peak detection and sampling and optical data transmission to an FPGA-based pipelined, parallel processor. This paper describes the system and the underpinning engineering solutions.

43 PARTICLE ACCELERATORS↗

A synthetic diagnostic for the evaluation of new microwave imaging reflectometry diagnostics for DIII-D and KSTAR

The first microwave imaging reflectometry (MIR) system for characterization of fluctuating plasma density has been implemented for the TEXTOR tokamak [H. Park et al., Rev. Sci. Instrum. 75, 3787 (2004)]; an improved MIR system will be installed on DIII-D and KSTAR. The central issue remains in preserving phase information by addressing antenna coupling between the reflection layer and the detector array in the presence of plasma turbulence. A synthetic diagnostic making use of coupled full-wave diffractive codes has been developed in geometries and applied to a variety of optical arrangements. The effectiveness of each scheme is quantitatively compared with respect to the fluctuation levels accessible in the simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Driver Linac for the Frankfurt Neutron Source

The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) will deliver high neutron fluxes in the energy range of 1 to 500 keV. The Activation Mode provides a high averaged neutron flux created by a cw proton beam of up to 5 mA, while in the Compressor Mode intense neutron pulses of 1 ns length are formed with a repetition rate of up to 250 kHz. The Compressor Mode is well-suited for energy-dependent neutron capture measurements using the Time-of-Flight method in combination with a 4{pi} BaF{sub 2} detector array. The design of the proton driver linac for both operation modes is presented. This includes the volume type ion source, the ExB chopper located in the low energy section, the RFQ-IH combination for beam acceleration and the bunch compressor. Finally, the neutron production at the lithium-7 target and the resulting energy spectrum is described.

43 PARTICLE ACCELERATORS↗