Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Manycore Performance-Portability: Kokkos Multidimensional Array Library

Large, complex scientific and engineering application code have a significant investment in computational kernels to implement their mathematical models. Porting these computational kernels to the collection of modern manycore accelerator devices is a major challenge in that these devices have diverse programming models, application programming interfaces (APIs), and performance requirements. The Kokkos Array programming model provides library-based approach to implement computational kernels that are performance-portable to CPU-multicore and GPGPU accelerator devices. This programming model is based upon three fundamental concepts: (1) manycore compute devices each with its own memory space, (2) data parallel kernels and (3) multidimensional arrays. Kernel execution performance is, especially for NVIDIA® devices, extremely dependent on data access patterns. Optimal data access pattern can be different for different manycore devices – potentially leading to different implementations of computational kernels specialized for different devices. The Kokkos Array programming model supports performance-portable kernels by (1) separating data access patterns from computational kernels through a multidimensional array API and (2) introduce device-specific data access mappings when a kernel is compiled. An implementation of Kokkos Array is available through Trilinos [Trilinos website, http://trilinos.sandia.gov/, August 2011].

Edwards, H. Carter↗

A microbial detection array (MDA) for viral and bacterial detection

Background: Identifying the bacteria and viruses present in a complex sample is useful in disease diagnostics, product safety, environmental characterization, and research. Array-based methods have proven utility to detect in a single assay at a reasonable cost any microbe from the thousands that have been sequenced. Methods: We designed a pan-Microbial Detection Array (MDA) to detect all known viruses (including phages), bacteria and plasmids and developed a novel statistical analysis method to identify mixtures of organisms from complex samples hybridized to the array. The array has broader coverage of bacterial and viral targets and is based on more recent sequence data and more probes per target than other microbial detection/discovery arrays in the literature. Family-specific probes were selected for all sequenced viral and bacterial complete genomes, segments, and plasmids. Probes were designed to tolerate some sequence variation to enable detection of divergent species with homology to sequenced organisms, and to have no significant matches to the human genome sequence. Results: In blinded testing on spiked samples with single or multiple viruses, the MDA was able to correctly identify species or strains. In clinical fecal, serum, and respiratory samples, the MDA was able to detect and characterize multiple viruses, phage, and bacteria in a sample to the family and species level, as confirmed by PCR. Conclusions: The MDA can be used to identify the suite of viruses and bacteria present in complex samples.

59 BASIC BIOLOGICAL SCIENCES↗

Method of rotation angle measurement in machine vision based on calibration pattern with spot array

We propose a method of rotation angle measurement with high precision in machine vision. An area scan CCD camera, imaging lens, and calibration pattern with a spot array make up the measurement device for measuring the rotation angle. The calibration pattern with a spot array is installed at the rotation part, and the CCD camera is set at a certain distance from the rotation components. The coordinates of the spots on the calibration pattern is acquired through the vision image of the calibration pattern captured by the CCD camera. At the initial position of the calibration pattern, the camera is calibrated with the spot array; the mathematical model of distortion error of the CCD camera is built. With the equation of coordinate rotation measurement, the rotation angle of the spot array is detected. In the theoretic simulation, noise of different levels is added to the coordinates of the spot array. The experiment results show that the measurement device can measure the rotation angle precisely with a noncontact method. The standard deviation of rotation angle measurement is smaller than 3 arc sec. The measurement device can measure both microangles and large angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Functional Gene Array for Detection of Bacterial Virulence Elements

Emerging known and unknown pathogens create profound threats to public health. Platforms for rapid detection and characterization of microbial agents are critically needed to prevent and respond to disease outbreaks. Available detection technologies cannot provide broad functional information about known or novel organisms. As a step toward developing such a system, we have produced and tested a series of high-density functional gene arrays to detect elements of virulence and antibiotic resistance mechanisms. Our first generation array targets genes from Escherichia coli strains K12 and CFT073, Enterococcus faecalis and Staphylococcus aureus. We determined optimal probe design parameters for gene family detection and discrimination. When tested with organisms at varying phylogenetic distances from the four target strains, the array detected orthologs for the majority of targeted gene families present in bacteria belonging to the same taxonomic family. In combination with whole-genome amplification, the array detects femtogram concentrations of purified DNA, either spiked in to an aerosol sample background, or in combinations from one or more of the four target organisms. This is the first report of a high density NimbleGen microarray system targeting microbial antibiotic resistance and virulence mechanisms. By targeting virulence gene families as well as genes unique to specific biothreat agents, these arrays will provide important data about the pathogenic potential and drug resistance profiles of unknown organisms in environmental samples.

59 BASIC BIOLOGICAL SCIENCES↗

Plasmonic surface lattice resonances in nanoparticle arrays

This work reviews the literature and provides a detailed computational analysis of the optical properties of one- and two-dimensional arrays of silver and gold nanoparticles, with emphasis on surface lattice resonances (SLRs) that arise when localized plasmon resonances (LSPRs) in the nanoparticles couple to diffraction resonances that are determined by the interparticle spacing to give polariton modes in which the two types of excitations are coherently coupled. The computations are based on the coupled dipole approximation, which provides a nearly quantitative description of the extinction spectra for arrays of this type where the particles are well separated and not too large. The computations are used to determine many characteristics of SLRs associated with the lower polariton mode that is mostly photonic in nature, and we also study the upper polariton that is dominated by the LSPR response, as well as Rayleigh anomalies (RAs) that correspond to purely diffractive excitation. The calculations explore the sensitivity of these excitations to the directions of the incident wave and polarization vectors relative to the array axis, the effect of array spacing and number of particles in the array, and the effect of nanoparticle radius and background refractive indices. Details of the physical mechanisms involved in determining blue- and/or redshifts as structural parameters are varied is provided, with SLR’s being sensitive to far-field coupling, while LSPR’s can also be sensitive to near- and intermediatefield interactions that in some cases are similar to effects found in dye molecule aggregates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Imaging the Shallow Structure of the Yucca Flat at the Source Physics Experiment Phase II Site with Horizontal-to-Vertical Spectral Ratio Inversion and a Large- N Seismic Array

The Source Physics Experiment (SPE) is a series of chemical explosions at the Nevada National Security Site (NNSS) with the goal of understanding seismic-wave generation and propagation of underground explosions. To understand explosion source physics, accurate geophysical models of the SPE site are needed. Here, we utilize a large-N seismic array deployed at the SPE phase II site to generate a shallow subsurface model of shear-wave velocity. The deployment consists of 500 geophones and covers an area of, approximately, 2.5 × 2 km. The array is located in the Yucca Flat in the northeast corner of the NNSS, Nye County, Nevada. Using ambient-noise recordings throughout the large-N seismic array, we calculate horizontal-to-vertical spectral ratios (HVSRs) across the array. We obtain 2D seismic images of shear-wave velocities across the SPE phase II site for the shallow structure of the basin. In this work the results clearly image two significant seismic impedance interfaces at ~150–500 and ~350–600 m depth. The shallower interface relates to the contrast between Quaternary alluvium and Tertiary volcanic rocks. The deeper interface relates to the contrast between Tertiary volcanic rocks and the Paleozoic bedrock. The 2D subsurface models support and extend previous understanding of the structure of the SPE phase II site. This study shows that the HVSR method in conjunction with a large-N seismic array is a quick and effective method for investigating shallow structures.

58 GEOSCIENCES↗

Design and Characterization of a Sodium Iodide (NaI) Array for Coincidence Measurements

An array of sodium iodide detectors (NaI) was constructed to record time-correlated gamma ray measurements. The NaI Array consists of twelve 2×4×16-inch detectors. When the array is placed close to an inspected object, this arrangement provides high efficiency for gamma ray detection, particularly for high-energy gamma rays. Data are collected in time-tagged, list-mode format, which is suitable for the application of a variety of coincidence analysis methods. Automated energy calibration of each detector is accomplished by utilizing gamma radiation from thoriated welding rods that are embedded in the system. The energy resolution of spectra that are produced by the NaI array is 7.3% at 662 keV. The data are processed to sum gamma-ray energies for simultaneous detections in adjacent detectors, which are dominated by the escape of scattered photons from one detector and subsequent absorption in an adjacent detector. When data are processed in this way, the photopeak efficiency exceeds 20% over the range 400 keV to 10 MeV; the total efficiency, which includes the Compton continuum and single and double escape peaks, exceeds 70% over this energy range. Utilization of time correlations enables isolation of spectral features that are associated with the same decay cascade or fission event. Characterization of the response of the NaI Array to both gamma rays and neutrons with the Gamma Detector Response and Analysis Software (GADRAS) enables accurate computation for virtually any radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Adaptive Beamforming to Signal Observations at the Mt. Meron Array, Israel

The Mt. Meron array consists of 16 stations spanning an aperture of 3-4 kilometers in northern Israel. The array is situated in a region of substantial topographic relief, and is surrounded by settlements at close range (Figure 1). Consequently the level of noise at the array is high, which requires efforts at mitigation if distant regional events of moderate magnitude are to be observed. This note describes an initial application of two classic adaptive beamforming algorithms to data from the array to observe P waves from 5 events east of the array ranging in distance from 1100- 2150 kilometers.

58 GEOSCIENCES↗

Development of a 1 x N Fiber Optic Sensor Array for Carbon Sequestration Site Monitoring

A fiber sensor array for sub-surface CO 2 concentrations measurements was developed for monitoring geologic carbon sequestration sites. The fiber sensor array uses a single temperature tunable distributed feedback (DFB) laser operating with a nominal wavelength of 2.004 μm. Light from this DFB laser is direct to one of the 4 probes via an in-line 1 x 4 fiber optic switch. Each of the 4 probes are buried and allow the sub-surface CO 2 to enter the probe through Millipore filters that allow the soil gas to enter the probe but keeps out the soil and water. Light from the DFB laser interacts with the CO 2 before it is directed back through the in-line fiber optic switch. The DFB laser is tuned across two CO 2 absorption features where a transmission measurement is made allowing the CO 2 concentration to be retrieved. The fiber optic switch then directs the light to the next probe where this process is repeated allowing sub-surface CO 2 concentration measurements at each of the probes to be made as a function of time. The fiber sensor array was deployed for fifty-eight days beginning June 19, 2012 at the Zero Emission Research Technology (ZERT) field site where sub-surface CO 2 concentrations were monitored. Background measurements indicate the fiber sensor array can monitor background levels as low as 1,000 parts per million (ppm). A thirty four day sub-surface release of 0.15 tones CO 2 /day began on July 10, 2012. The elevated subsurface CO 2 concentration was easily detected by each of the four probes with values ranging to over 60,000 ppm, a factor of greater than 6 higher than background measurements. The fiber sensor array was also deploy at the Big Sky Carbon Sequestration Partnership (BSCSP) site in north-central Montana between July 9th and August 7th, 2013 where background measurements were made in a remote sequestration site with minimal infrastructure. The project provided opportunities for two graduate students to participate in research directly related to geologic carbon sequestration. Furthermore, commercialization of the technology developed is being pursued with five different companies via the Department of energy SBIR/STTR program

47 OTHER INSTRUMENTATION↗

Packed Ultra-wideband Mapping Array (PUMA): A Radio Telescope for Cosmology and Transients

PUMA is a proposal for an ultra-wideband, low-resolution and transit interferometric radio telescope operating at $200-1100\,\mathrm{MHz}$. Its design is driven by six science goals which span three science themes: the physics of dark energy (measuring the expansion history and growth of the universe up to $z=6$), the physics of inflation (constraining primordial non-Gaussianity and primordial features) and the transient radio sky (detecting one million fast radio bursts and following up SKA-discovered pulsars). We propose two array configurations composed of hexagonally close-packed 6m dish arrangements with 50% fill factor. The initial 5,000 element 'petite array' is scientifically compelling, and can act as a demonstrator and a stepping stone to the full 32,000 element 'full array'. Viewed as a 21cm intensity mapping telescope, the program has the noise equivalent of a traditional spectroscopic galaxy survey comprised of 0.6 and 2.5 billion galaxies at a comoving wavenumber of $k=0.5\,h\mathrm{Mpc}^{-1}$ spanning the redshift range $z = 0.3 - 6$ for the petite and full configurations, respectively. At redshifts beyond $z=2$, the 21cm technique is a uniquely powerful way of mapping the universe, while the low-redshift range will allow for numerous cross-correlations with existing and upcoming surveys. This program is enabled by the development of ultra-wideband radio feeds, cost-effective dish construction methods, commodity radio-frequency electronics driven by the telecommunication industry and the emergence of sufficient computing power to facilitate real-time signal processing that exploits the full potential of massive radio arrays. The project has an estimated construction cost of 55 and 330 million FY19 USD for the petite and full array configurations. Including R&D, design, operations and science analysis, the cost rises to 125 and 600 million FY19 USD, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismic Wave Coherence as a Function of Propagation Azimuth at the Large-N Array, Source Physics Experiment

The Large-N array of the Source Physics Experiment (SPE) consisted, in part, of 496 vertical component geophones that recorded the seismic wave field produced by the SPE-5 buried chemical explosion. Preliminary observations of the data showed a large degree of azimuthally dependent seismic scattering, particularly for post-P wave arrivals, hindering surface wave analysis. We document and quantify the azimuthal dependence of the wave field scattering in order to guide future coherent wave field processing methods. Specifically, we form three linear arrays, with different nominal source-receiver azimuths, by extracting a subset of the Large-N stations. For each linear array, we evaluate wave field coherence as a function of frequency and inter-station distance. For P waves, we observe that there is a strong azimuthal dependence of wave coherence, with the highest degree of scattering occurring in a northwest/southeast propagation direction. This suggests that there are structural elements beneath the Large-N array that affect the direct source to receiver body wave ray path. We also observe that the scattering of the post-P energy displays a coherence that is dependent on both frequency and azimuthal direction. This energy is preferentially coherent in the southwest-to-northeast propagation direction, consistent with the strike of the steeply dipping fault (Boundary fault) adjacent to the northeast side of the Large-N array, but only at low frequencies (<10 Hz). At higher frequencies, the azimuthally dependent wave coherence diminishes, suggesting that the scattering of high frequency portion of the post-P wave field is independent of the large-scale geologic structure at this site.

58 GEOSCIENCES↗

The IEA Wind Task 49 Reference Floating Wind Array Design Basis

International Energy Agency Wind Technology Collaboration Programme (IEA Wind) Task 49 on Integrated Design of Floating Wind Arrays is an international collaboration aiming to advance the development of large-scale floating wind farms by providing open-access resources to the research and development and planning communities. The work of Task 49 focuses on array-level challenges related to the colocation of many floating wind turbines; their layouts, mooring systems, and cabling systems; failure risks; logistical considerations; marine spatial planning needs; and future research needs and innovation directions. This report provides a general design basis for the development of reference floating wind farm designs. These reference array designs will extend the scope of existing reference floating wind turbine designs to facilitate research on array-level floating wind technology challenges and innovations. The design basis promotes coordination and consistency in developing the reference array designs.

17 WIND ENERGY↗

Assessment of North Slope of Alaska (NSA) Snow Monitoring Arrays

Arrays of instruments for monitoring winter precipitation (snowfall) and snow cover on the ground installed in 2017 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska (NSA) C1 and at Oliktok Point sites became operational in 2018. In 2022, the instruments from Oliktok Point were moved to NSA E12, about 5.4 km south of NSA C1, where two arrays now operate. The instrument arrays monitor wind speed and direction, snow depth at multiple locations, the horizontal flux of blowing snow, and the number and fall speed of hydrometeors. The arrays are monitored using digital cameras. Collectively, the instruments produce a wealth of data on falling and accumulated snow, but, as with any instrument array, some data are more reliable and accurate than others. In this document, we present our findings on the efficacy, accuracy, and reliability of each type of instrument. Overall, a key finding is that no single instrument provides sufficient information to determine the source of falling snow particles nor the cause of changes in snow depth. However, if used in concert, the instruments produce a reliable understanding of the processes affecting the snow cover depth distribution and the true winter precipitation.

47 OTHER INSTRUMENTATION↗

Zero-Order Phased Fiber Arrays

Phased arrays remain an important strategy for scaling average power and pulse energy in optical fiber lasers. In zero-order arrays, the lengths of the constituent lasers or amplifiers are matched to within the coherence length of a pulse; for fibers having bandwidths on the order of one nanometer, lengths must be matched to 1 mm; for fiber having bandwidths on the order of 30 nm (pulse duration of 100 fs), lengths must be matched to 30 {micro}m. The overarching goal of this work has been to demonstrate a scaling path to 10 mJ pulses from an array of fiber lasers, with each fiber contributing roughly 1 mJ of energy. The near term goals were, and remain, two-fold. First, to demonstrate that arrays of fiber amplifier chains can be created having path length differences on the order of sub-picoseconds. This has been accomplished, showing that sub-nanojoule, 200 fs pulses can be split into an array of four chains, each chain amplified with a single preamp, and the outputs can be recombined within the coherence length of the pulses. The second near term goal, stabilizing the phase through active feedback, is not yet complete. The strategy has been to generate an out-of-band CW seed signal that is monitored to account for fluctuations in path length that occur between pulses. At this point the necessary hardware is in place, but the control electronics are not. We expect the co-phasing work to continue under separate funding, though in a simpler form. Instead of combining pulses from many amplifiers we would combine many sequential pulses from a single fiber laser via a resonant cavity. Such a scheme is less expensive to build and test (and eventually, to field), though significant technical hurdles must be overcome, including the development of a low-loss mechanism for releasing the energy that is built up within the cavity.

42 ENGINEERING↗

The development of a high-throughput gradient array apparatus for the study of porous polymer networks.

A gradient array apparatus was constructed for the study of porous polymers produced using the process of chemically-induced phase separation (CIPS). The apparatus consisted of a 60 element, two-dimensional array in which a temperature gradient was placed in the y-direction and composition was varied in the x-direction. The apparatus allowed for changes in opacity of blends to be monitored as a function of temperature and cure time by taking images of the array with time. The apparatus was validated by dispense a single blend composition into all 60 wells of the array and curing them for 24 hours and doing the experiment in triplicate. Variations in micron scale phase separation were readily observed as a function of both curing time and temperature and there was very good well-to-well consistency as well as trial-to-trial consistency. Poragen of samples varying with respect to cure temperature was removed and SEM images were obtained. The results obtained showed that cure temperature had a dramatic affect on sample morphology, and combining data obtained from visual observations made during the curing process with SEM data can enable a much better understanding of the CIPS process and provide predictive capability through the relatively facile generation of composition-process-morphology relationships. Data quality could be greatly enhanced by making further improvements in the apparatus. The primary improvements contemplated include the use of a more uniform light source, an optical table, and a CCD camera with data analysis software. These improvements would enable quantification of the amount of scattered light generated from individual elements as a function of cure time. In addition to the gradient array development, porous composites were produced by incorporating metal particles into a blend of poragen, epoxy resin, and crosslinker. The variables involved in the experiment were metal particle composition, primary metal particle size, metal concentration, and poragen composition. A total of 16 different porous composites were produced and characterized using SEM. In general, the results showed that pore morphology and the distribution of metal particles was dependent on multiple factors. For example, the use of silver nanoparticles did not significantly affect pore morphology for composites derived from decanol as the poragen, but exceptionally large pores were obtained with the use of decane as the poragen. With regard to the effect of metal particle size, silver nanoparticles were essentially exclusively dispered in the polymer matrix while silver microparticles were found in pores. For nickel particles, both nanoparticles and microparticles were largely dispersed in the polymer matrix and not in the pores.

36 MATERIALS SCIENCE↗

Simulated Impact of Shortened Strings in Commercial and Utility-Scale Photovoltaic Arrays

The deliberate removal of photovoltaic modules from a string can occur for various reasons encompassing maintenance, measurements, theft, or failure, reducing that string length relative to others when replacement modules are not available and there are not any viable alternative makes and models that could be inserted. This phenomenon, delineated in our prior experimentally validated research, manifests two significant effects: (1) a shift in the ideal maximum power point and (2) the induction of potentially substantial reverse currents in the shortened strings at open-circuit voltage, VOC. However, the scalability and asymptotic limits of these observed behaviors concerning array size remained undetermined. In this study, we elucidate the operational dynamics of such arrays by manipulating two mismatch-contributing variables in simulated arrays of up to 900 strings: the number of removed modules per string (indicative of the level of mismatch, ranging up to 5) and the quantity of shortened strings (1 to 60). Simulation outcomes underscore that mismatch severity impacts array operation more than the proportion of shortened strings. This research delves into the practical ramifications of operating with shortened strings, including implications for low-irradiance operation and the manifestation of deleterious reverse currents (>35 A in specific cases), emphasizing the need for careful array configuration for optimal performance and safety in these implementations.

Energy & Fuels↗

First M87 Event Horizon Telescope Results. II. Array and Instrumentation

The Event Horizon Telescope(EHT)is a very long baseline interferometry (VLBI) array that comprises millimeter- and submillimeter-wavelength telescopes separated by distances comparable to the diameter of the Earth. At a nominal operating wavelength of∼1.3 mm, EHT angular resolution(λ/D)is∼25μas, which is sufficient to resolve nearby supermassive black hole candidates on spatial and temporal scales that correspond to their event horizons. With this capability, the EHT scientific goals are to probe general relativistic effects in the strong-field regime and to study accretion and relativistic jet formation near the black hole boundary. In this Letterwe describe the system design of the EHT, detail the technology and instrumentation that enable observations, and provide measures of its performance. Meeting the EHT science objectives has required several key developments that have facilitated the robust extension of the VLBI technique to EHT observing wavelengths and the production of instrumentation that can be deployed on a heterogeneous array of existing telescopes and facilities. To meet sensitivity requirements, high-bandwidth digital systems were developed that process data at rates of 64 gigabit s−1, exceeding those of currently operating cm-wavelength VLBI arrays by more than an order of magnitude. Associated improvements include the development of phasing systems at array facilities, new receiver installation at several sites, and the deployment of hydrogen maser frequency standards to ensure coherent data capture across the array. These efforts led to the coordination and execution of the first Global EHT observations in2017 April, and to event-horizon-scale imaging of the supermassive black hole candidate in M87.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal stability of HfO2 nanotube arrays

Thermal stability of highly ordered hafnium oxide (HfO2) nanotube arrays prepared through an electrochemical anodization method in the presence of ammonium fluoride is investigated in a temperature range of room temperature to 900 C in flowing argon atmosphere. The formation of the HfO2 nanotube arrays was monitored by current density transient characteristics during anodization of hafnium metal foil. Morphologies of the as-grown and post-annealed HfO2 nanotube arrays were analyzed by powder Xray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Although monoclinic HfO2 is thermally stable up to 2000K in bulk, the morphology of HfO2 nanotube arrays degraded at 900 C. A detailed X-ray photoelectron spectroscopy (XPS) study revealed that the thermal treatment significantly impacted the composition and the chemical environment of the core elements (Hf and O), as well as F content coming from the electrolyte. Possible reasons for the degradation of the nanotube at high temperature were discussed based on XPS study and possible future improvements have also been suggested. Moreover, dielectric measurements were carried out on both the as-grown amorphous film and 500 C post-annealed crystalline film. This study will help us to understand the temperature impact on the morphology of nanotube arrays, which is important to its further applications at elevated temperatures.

36 MATERIALS SCIENCE↗