Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Pseudospark-sourced Electron Beam for Millimeter Wave and Terahertz Radiation Generation

The production and propagation of an electron beam from both a multi-gap and a small-scale single-gap pseudospark discharge are investigated. From a three-gap pseudospark, a beam up to 680 A was measured at the anode at an applied dc voltage of 23 kV. This beam can propagate downstream as far as 20 cm in a gaseous environment with no guiding magnetic field, which confirms that the transport of the electron beam was based on the neutralization of the space-charge of the electron beam due to the ionization of the gas molecules by the beam itself. The beam is of very small size of 1-3 mm in diameter and is ideal to drive high frequency radiation. Higher energy electron beam pulses were generated using a 14-gap pseudospark discharge powered by a cable pulser capable of producing 120 ns duration and 170 kV voltage pulses. The beam measured had a current of up to 110 A. A Ka-band Cherenkov maser and a W-band backward wave oscillator from the produced beam were simulated and experimentally studied. Millimeter wave pulses were detected successfully from both devices. In an effort to show the effects of scaling down the size of the pseudospark discharge on beam performance, a single-gap 1 mm aperture pseudospark electron beam experiment was conducted, based on which a 206 GHz microklystron was designed and simulated.

43 PARTICLE ACCELERATORS↗

TH-A-19A-08: Intel Xeon Phi Implementation of a Fast Multi-Purpose Monte Carlo Simulation for Proton Therapy

Purpose: Recent studies have demonstrated the capability of graphics processing units (GPUs) to compute dose distributions using Monte Carlo (MC) methods within clinical time constraints. However, GPUs have a rigid vectorial architecture that favors the implementation of simplified particle transport algorithms, adapted to specific tasks. Our new, fast, and multipurpose MC code, named MCsquare, runs on Intel Xeon Phi coprocessors. This technology offers 60 independent cores, and therefore more flexibility to implement fast and yet generic MC functionalities, such as prompt gamma simulations. Methods: MCsquare implements several models and hence allows users to make their own tradeoff between speed and accuracy. A 200 MeV proton beam is simulated in a heterogeneous phantom using Geant4 and two configurations of MCsquare. The first one is the most conservative and accurate. The method of fictitious interactions handles the interfaces and secondary charged particles emitted in nuclear interactions are fully simulated. The second, faster configuration simplifies interface crossings and simulates only secondary protons after nuclear interaction events. Integral depth-dose and transversal profiles are compared to those of Geant4. Moreover, the production profile of prompt gammas is compared to PENH results. Results: Integral depth dose and transversal profiles computed by MCsquare and Geant4 are within 3%. The production of secondaries from nuclear interactions is slightly inaccurate at interfaces for the fastest configuration of MCsquare but this is unlikely to have any clinical impact. The computation time varies between 90 seconds for the most conservative settings to merely 59 seconds in the fastest configuration. Finally prompt gamma profiles are also in very good agreement with PENH results. Conclusion: Our new, fast, and multi-purpose Monte Carlo code simulates prompt gammas and calculates dose distributions in less than a minute, which complies with clinical time constraints. It has been successfully validated with Geant4. This work has been financialy supported by InVivoIGT, a public/private partnership between UCL and IBA.

07 ISOTOPE AND RADIATION SOURCES↗

H-mode Accelerating Structures with PMQ Focusing for Low-Beta Beams

We report on results of the project developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. The shunt impedance of IH-PMQ structures is 10-20 times higher than that of a conventional drift-tube linac, while the transverse size is 4-5 times smaller. The H-PMQ accelerating structures following a short RFQ can be used both in the front end of ion linacs or in stand-alone applications. Results of the combined 3-D modeling -- electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis -- for a full IH-PMQ accelerator tank are presented. The accelerating field profile in the tank is tuned to provide the best propagation of a 50-mA deuteron beam using coupled iterations of EM and beamdynamics modeling. Multi-particle simulations withParmela and CST Particle Studio have been used to confirm the design. Measurement results of a cold model of the IH-PMQ tank are presented.

Accelerator Design, Technology, and Operations↗

Beam ion instability: Measurement, analysis, and simulation

A weak vertical coupled-bunch instability with oscillation amplitude of the order of a few μ m has been observed in SPEAR3 at nominal vacuum pressure. The instability becomes stronger with increasing neutral gas pressure as observed by turning off vacuum pumps, and becomes weaker when the vertical beam emittance is increased. These observations indicate that the vertical beam motion is driven by ions trapped in the periodic potential of the electron beam. In this paper we present a series of comprehensive beam measurements, impedance-based stability analysis, and numerical simulations of beam-ion interactions in SPEAR3. The effects of vacuum pressure, gas species, beam current, bunch fill pattern, chromaticity, and vertical beam emittance are investigated.

43 PARTICLE ACCELERATORS↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

Modeling the Amplfied OSC Experiment at IOTA

Optical Stochastic Cooling (OSC), a beam cooling technique based on Stochastic Cooling, is in the early stages of experimental development. It uses radiation produced by the beam in an undulator magnet (the pickup) to correct the momentum deviation of particles downstream in another undulator (the kicker). The OSC mechanism was recently demonstrated at Fermilabʼs IOTA ring using a passive configuration. However, the cooling rate of OSC can be dramatically increased by first amplifying the undulator radiation before applying the corrective kick. In collaboration with the IOTA experiment, we developed a computational model of the OSC mechanism. This work presents beam‐dynamics simulations of the amplified‐OSC configuration. We implement a model of intrabeam scattering and study the effects on beam equilibrium and diffusion rate as a function of bunch charge. Finally, we investigate the phase‐space dynamics with various coupling configurations between the transverse and longitudinal planes.

Dick, A. J.↗

SU-E-T-321: The Effects of a Dynamic Collimation System On Proton Pencil Beams to Improve Lateral Tissue Sparing in Spot Scanned Proton Therapy

Purpose: To evaluate the lateral beam penumbra in pencil beam scanning proton therapy delivered using a dynamic collimator device capable of trimming a portion of the primary beam in close proximity to the patient. Methods: Monte Carlo simulations of pencil beams were performed using MCNPX. Each simulation transported a 125 MeV proton pencil beam through a range shifter, past acollimator, and into a water phantom. Two parameters were varied among the simulations, the source beam size (sigma in air from 3 to 9 mm), and the position of the edge of the collimator (placed from 0 to 30 mm from the central axis of the beam). Proton flux was tallied at the phantom surface to determine the effective beam sizefor all combinations of source beam size and collimator edge position. Results: Quantifying beam size at the phantom surface provides a useful measure tocompare performance among varying source beam sizes and collimation conditions. For arelatively large source beam size (9 mm) entering the range shifter, sigma at thesurface was found to be 10 mm without collimation versus 4 mm with collimation. Additionally, sigma at the surface achievable with collimation was found to be smallerthan for any uncollimated beam, even for very small source beam sizes. Finally, thelateral penumbra achievable with collimation was determined to be largely independentof the source beam size. Conclusion: Collimation can significantly reduce proton pencil beam lateral penumbra.Given the known dosimetric disadvantages resulting from large beam spot sizes,employing a dynamic collimation system can significantly improve lateral tissuesparing in spot-scanned dose distributions.

60 APPLIED LIFE SCIENCES↗

IMPACT-T User Document Version 1.6

IMPACT-T is a fully three-dimensional program to track relativistic particles taking into account space charge forces and short-range longitudinal and transverse wakenelds. IMPACT-T is one of the few codes used in the photoinjector community that has a parallel implementation, making it very useful for high statistics simulations of beam halos and beam diagnostics. It has a comprehensive set of beamline elements, and furthermore allows arbitrary overlap of their fields, which gives the IMPACT-T a capability to model both the standing wave structure and traveling wave structure. It is also unique in its use of space-charge solvers based on an integrated Green function to efficiently and accurately treat beams with large aspect ratio, and a shifted Green function to efficiently treat image charge effects of a cathode. It is also unique in its inclusion of energy binning in the space-charge calculation to model beams with large energy spread. IMPACT-T has a flexible data structure that allows particles to be stored in containers with common characteristics; for photoinjector simulations the containers represent multiple slices, but in other applications they could correspond, e.g., to particles of different species. Together, all these features make IMPACT-T a powerful and versatile tool for modeling beams in photoinjectors and other systems.

99 GENERAL AND MISCELLANEOUS↗

Adiabatic Formation of a Matched-beam Distribution for an Alternating-gradient Quadrupole Lattice

The formation of a quasiequilibrium beam distribution matched to an alternating-gradient quadrupole focusing lattice by means of the adiabatic turn-on of the oscillating focusing field is studied numerically using particle-in-cell simulations. Quiescent beam propagation over several hundred lattice periods is demonstrated for a broad range of beam intensities and vacuum phase advances describing the strength of the oscillating focusing field. Properties of the matched-beam distribution are investigated. In particular, self-similar evolution of the beam density profile is observed over a wide range of system parameters. The numerical simulations are performed using the WARP particle-in-cell code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of radial expansion of an electron beam injected into a background plasma

A 2-D electrostatic particle code was used to study the beam radial expansion of a nonrelativistic electron beam injected from an isolated equipotential conductor into a background plasma. The simulations indicate that the beam radius is generally proportional to the beam electron gyroradius when the conductor is charged to a large potential. The simulations also suggest that the charge buildup at the beam stagnation point causes the beam radial expansion. From a survey of the simulation results, it is found that the ratio of the beam radius to the beam electron gyroradius increases with the square root of beam density and decreases inversely with beam injection velocity. This dependence is explained in terms of the ratio of the beam electron Debye length to the ambient electron Debye length. These results are most applicable to the SEPAC electron beam injection experiments from Spacelab 1, where high charging potential was observed.

Koga, J.↗

Second harmonic Bessel-Gauss beam shaping with elliptic axicon aberrations

The second harmonic (SH) of an axicon generated Bessel-Gauss beam is created through the nonlinear interaction of photons with a crystal, resulting in the energy doubling of the output photons. In this work, we show experimentally that in addition to frequency doubling, the SH of Bessel-Gauss beams under asymmetric aberrations from an elliptic axicon exhibit intriguing beam formation. Particularly, the central region of the SH beam profile is composed of two central spots of various geometries surrounded by nested ellipses; one of which is the configuration of two central gamma dots with similar radius knotted by nested ellipses for a zeroth-order Bessel-Gauss pump. These SH beams consistently maintain their spatial profile throughout propagation, reminiscing the behavior of screw dislocations in wave patterns. Our numerical simulations produce beam dynamics consistent with that of experiments and further implicate the remarkable interweaving of bright spots with dark vortices. This is especially noticeable when the beams dynamically oscillate along the optical axis, resulting in the genesis of spatially polarized beams with a knotted framework. The insights gained from our study establish a novel paradigm for exploring interactions of Bessel-like beams with vortex dynamics. This, in turn, has the potential to spark innovations in optical applications, fostering new methodologies to harness and manipulate complex light structures. Our experimental findings could spur new methods of generating logical states of light and new opportunities for material processing control. Published by the American Physical Society 2025

Wang, Tianhong (ORCID:0000000169104201)↗

Modeling of the amplified optical stochastic cooling experiment at IOTA

Optical Stochastic Cooling (OSC), a beam cooling technique based on Stochastic Cooling, is in the early stages of experimental development. It uses radiation produced by the beam in an undulator magnet (the pickup) to correct the momentum deviation of particles downstream in another undulator (the kicker). The OSC mechanism was recently demonstrated at Fermilab’s IOTA ring using a passive configuration. However, the cooling rate of OSC can be dramatically increased by first amplifying the undulator radiation before applying the corrective kick. In collaboration with the IOTA experiment, we developed a computational model of the OSC mechanism. This paper presents beam-dynamics simulations of the amplified-OSC configuration. We implement a model of intrabeam scattering and study the effects on beam equilibrium and diffusion rate as a function of bunch charge. Finally, we investigate the phase-space dynamics with various coupling configurations between the transverse and longitudinal planes.

43 PARTICLE ACCELERATORS↗

Simulation Studies of Intra-Train, Bunch-by-Bunch Feedback Systems at the International Linear Collider

The International Linear Collider (ILC) is a proposed electron-positron collider targeting collision energies from 250 GeV to 1 TeV. With design luminosities of order 10³⁴ cm²s⁻¹, a beam-based, intra-train feedback system would be required near the Interaction Point (IP) to provide nanometre-level stabilisation of the beam overlap in the collisions. Here we present results from beam-tracking simulations of the 500 GeV ILC, including the impact of beam-trajectory imperfections on the luminosity, and the capability of the IP feedback system to compensate for them. Effects investigated include the position jitter introduced by the damping ring extraction kicker, short-range and long-range wakefields, and ground motion. The feedback system was shown to be able to correct for beam-beam offsets of up to 200 nm and stabilise the collision overlap to the nanometre level, within a few bunch crossings.

Ramjiawan, R. L.↗

Editorial announcements and information — ICFA Beam Dynamics Newsletter No. 81

This is a general information article of the ICFA Beam Dynamics Newsletter No. 81. Thus, it contains two forewords from the Editor-in-Chief and the issue editor, a workshop and conference report section, a recent Ph.D. thesis section, a forthcoming beam dynamics events section, and a section of announcements from the beam dynamics panel.

47 OTHER INSTRUMENTATION↗

Space radiation simulation using blowout plasma wakes at the SAMURAI Lab

We discuss the creation of broadband electron energy spectra using plasma wakefield acceleration at the SAMURAI Lab as part of the UCLA Particle Beam Physics Laboratory group. As the exploration and development of space increases, it will become important to efficiently replicate radiation conditions that exist in low earth orbit and planetary space. Missions such as satellite deployment and exploration of other planets, i.e. the Juno probe launched to explore Jupiter [1], require electronics that are able to withstand the electron radiation spectrum present in these locations. This requires Earth-based testing for development of robust electronics with respect to electron radiation exposure. Conventional accelerators are poorly suited for this purpose because they are designed for monoenergetic electron beams. Current simulation schemes involve the interpolation of discrete exposure tests, with time structures entirely different from space events. This idea poorly captures the radiation damage physics seen in the real world. Conversely, the wakefields produced in the blowout regime of beam plasma wakefield accelerators can be used to create the full spectrum of space radiation including high energy “killer” electrons by injecting a long bunch to excite the plasma blowout. With a long bunch ( k p σ z ≈ 2 ) the beam will feel both accelerating and decelerating fields, resulting in an exponential or power law energy spectrum distribution seen in regions outside the Earth and Jupiter. This can be achieved at the new SAMURAI lab at UCLA resulting in broadband energy spectra with maximum energies up to 100 MeV that correctly reflect the radiative conditions of space in low Earth orbit and around Jupiter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the UED beam line design via ImpactT simulation

The high charge low energy compressor system developed at NSLS-II can generate 5MeV electron bunches with 50pC charge (10 -8 electrons) focusing to 30 micron beam size and bunch length of order of 100 fs. NSLS-II plans to build it as part of the existing instrument for the ultra-fast electron diffraction (UED) and ultra-fast electron microscope (UEM) experiments to be installed at ATF-II, BNL. The expected intensity will be several orders of magnitudes higher than achieved previously using current technology (~10 -4 -10 -5 electrons). This type of accelerator based MeV electron microscopes, taking advantage of strong interaction of electrons with matter and overcoming space charge problem, are complementary to XFEL, such as LCLS.

36 MATERIALS SCIENCE↗

Transverse BBU Suppression with Feedback for Energy Recovery Linacs

In this study, we present beam dynamics simulations of the Strong Hadron Cooling (SHC) Energy Recovery Linac (ERL) that incorporate a feedback (FB) system designed to mitigate Beam Breakup (BBU) instabilities. The FB effectively suppresses BBU and increases the threshold current by roughly an order of magnitude. Our analysis revealed the aliasing behavior of the dominant higher-order mode (HOM) and its suppression by the FB, as evident from the power spectral density (PSD) of the beam centroid’s horizontal motion at the exit of the final linac section. Although the FB system— even when affected by noise—successfully reduced the BBU peak, it also amplified the PSD at other frequencies. These results provide important insights into BBU suppression and threshold current enhancement in ERLs.

Setiniyaz, S. [Thomas Jefferson National Accelerat↗