Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

SU-F-T-506: Development and Commissioning of the Effective and Efficient Grid Therapy Using High Dose Rate Flattening Filter Free Beam and Multileaf Collimator

Purpose: Treating bulky tumors with grid therapy (GT) has demonstrated high response rates. Long delivery time (∼15min), with consequent increased risk of intrafraction motion, is a major disadvantage of conventional MLC-based GT (MLC-GT). The goal of this study was to develop and commission a MLC-GT technique with similar dosimetric characteristics, but more efficient delivery. Methods: Grid plan was designed with 10X-FFF (2400MU/min) beam and MLC in a commercial treatment planning system (TPS). Grid size was 1cm by 1cm and grid-to-grid distance was 2cm. Field-in-field technique was used to flatten the dose profile at depth of 10cm. Prescription was 15Gy at 1.5cm depth. Doses were verified at depths of 1.5cm, 5cm and 10cm. Point dose was measured with a plastic scintillator detector (PSD) while the planar dose was measured with calibrated Gafchromic EBT3 films in a 20cm think, 30cmx30cm solid water phantom. The measured doses were compared to the doses calculated in the treatment planning system. Percent depth dose (PDD) within the grid was also measured using EBT3 film. Five clinical cases were planned to compare beam-on time. Results: The valley-to-peak dose ratio at the 3 depths was approximately 10–15%, which is very similar to published result. The average point dose difference between the PSD measurements and TPS calculation is 2.1±0.6%. Film dosimetry revealed good agreement between the delivered and calculated dose. The average gamma passing rates at the 3 depths were 95% (3%, 1mm). The average percent difference between the measured PDD and calculated PDD was 2.1% within the depth of 20cm. The phantom plan delivery time was 3.6 min. Average beam-on time was reduced by 66.1±5.6% for the 5 clinical cases. Conclusion: An effective and efficient GT technique was developed and commissioned for the treatment of bulky tumors using FFF beam combined with MLC and automation. The Department of Radiation Oncology at Henry Ford Health System receives research support from Varian Medical Systems and Philips Health Care.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 02: Feasibility of using multileaf collimation for stereotactic radiosurgery of arteriovenous malformation

SRS using linac and cones offers steep dose fall-off but a tradeoff exists between conformality and treatment time, which depends on the number of isocentres. Purpose of this study is to quantify planning metrics between cones- and MLC-based SRS for arteriovenous malformation(AVM). Seven AVM cases treated with cones were re-planned with MLC on Pinnacle treatment planning system. Planning target volume(PTV) was created with 1mm uniform margin to the AVM to account for MLC positional variation. Clinically-planned prescription dose(15–25Gy) was used. Four plans were generated per case:non-coplanar VMAT(ncV), single-arc VMAT(saV), non-coplanar IMRT(ncI), non-coplanar conformal(ncC). Plans were compared for conformity(CI), heterogeneity(HI) and gradient(GI) indices and brain doses. Estimated treatment times and monitor units(MU) were compared. Cone-based plans required 2–6 isocentres. Though CI-RTOG was similar for plans(median=0.98), CI-Paddick was most favourable for ncV(median=0.86) and worst for cones(0.54). HI for MLC plans(median=1.19–1.27) were lower than cone-based plans(1.43). GI was similar for all plans. For 2/7 ncC had brainstem maximum dose>16.7Gy and therefore were clinically unacceptable. Brain V12Gy,V10Gy,V2Gy were lowest in the cones plan. ncV brain V12Gy,V10Gy,V2Gy were lowest of all MLC-based plans studied. Treatment MUs were similar for MLC-based plans and up to 70% lower than clinically delivered plans. ncV showed best conformality in this study. Of the MLC-based plans, ncV also showed lowest normal tissue dose with reasonable treatment time.

60 APPLIED LIFE SCIENCES↗

Pattern Recognition: The Importance of Dispersion in Crystal Collimation

One aspect of the upcoming CRYSTAL experiment is to study the dynamics of single protons circulating the SPS in the presence of a crystal. Under some circumstances (for example under crystal channeling) a proton may hit the crystal and the neighboring silicon strip position detectors only once, before extraction from the SPS. In general (at most crystal rotation angles) it is expected that single protons will hit the crystal many times, with many accelerator turns between each hit, before escaping. Intermediate regimes are also possible (for example under volume reflection) in which a proton hits the crystal only a few times over many turns before being lost.

43 PARTICLE ACCELERATORS↗

Advanced X-ray Collection and Collimation Optic

Incom Inc. and Brookhaven National Laboratory have a mutual interest in developing and testing an X-ray optic that will function in an advanced detector system. This optic leverages the development work already carried out at Incom in drawing hollow core capillary structures. Incom has developed a revolutionary method for fabricating arrays of hollow capillary structures out of several types of glass and is investigating several market applications for this technology, including large area (9”x9”) microchannel plates for electron amplification, hydrogen storage, and x-ray optics, the subject of this application. Methods have been developed for fabricating hexagonally arranged polycapillaries with outside diameters in the range of .020”-0.25” with capillary internal diameters from 2-350+ µm. Initial trials of capillary tapering have yielded promising results. BNL’s expertise in the development of X-ray optics, especially x-ray spectrometers will be utilized in the development of the unique lens concept and its integration into the spectrometer.

42 ENGINEERING↗

Advanced X-ray Collection and Collimation Optic

To develop and specify a design for a cost-effective, high-resolution x-ray spectrometer and its x-ray lenses is the goal of this proposal. Optimized polycarpellary lenses will be fabricated, characterized and implemented in the spectrometer. Based on the results a system analysis is performed and verified in a feasibility study.

47 OTHER INSTRUMENTATION↗

Radiological Consequences of Beam Loss on Beamline Front End Collimator during Top-off Injection into the Storage Ring

The primary radiological safety concern for the top-off injection, with the beam line front end safety shutters open, is the scenario where electrons could be conveyed down to the beam line through the front end due to the erroneous combination of lattice magnetic field settings and beam energy. It is of paramount importance to ensure that such events are of remote possibility. Particle tracking simulations by the NSLS-II Accelerator Physicists have shown that by a set of interlocking requirements of the lattice magnetic fields and by the implementation of physical apertures, the errant electron beam can be confined to the front end components within the storage ring.

36 MATERIALS SCIENCE↗

Evaluation of Various Collimators for UF6 Gas Pipe Measurement

On-line gamma measurements of the enrichment of uranium in UF6 gas in pipes is carried out as part of international safeguards. The 186 keV line from 235 U is measured in NaI detectors. One complication in the analysis is that the 186 keV line also comes from the (time-dependent) amount of uranium-bearing material deposited on the interior walls of the pipe. This contribution has to be subtracted before the enrichment of the gas can be calculated. The relative contributions to the total 186 keV count rate from the gas and from the deposit depends on the amount of deposit, but also on the type of collimation/shielding used between the NaI detector and the gas pipe. Several different collimation/shielding designs have been simulated in order to determine which provides the best performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Design Study of the Parallel-Slit Ring Collimator for Fast Neutron Emission Tomography of Spent Fuel

For the past 18 months, Oak Ridge National Laboratory has been developing a passive fast-neutron emission tomography capability. The goal of this development is a new passive capability to detect diversion of single fuel pins (rods) from spent or used nuclear fuel assemblies by performing neutron emission tomography. At present, a laboratory prototype imager is under construction. The purpose of the prototype imager is to demonstrate imaging capability sufficient to resolve individual fuel pins in a spent nuclear fuel assembly. This report documents the results of simulation studies to optimize the design of the prototype imager.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic Image Reconstruction for the Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

For the past three years, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly in order to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager is under construction. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies. This report documents the development of the iterative reconstruction code used to perform tomographic image reconstruction, the imager response calculation used by the reconstruction code, and the results of reconstructions of simulated tomographic imaging measurements for the prototype imager design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Measurements with the Prototype Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

Since 2017, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager has been built and initial imaging measurements performed. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies, and in initial measurements, neutron sources separated by a spacing of 1.27 cm (similar to the spacing between fuel pins in commercial pressurized water reactor 17×17 nuclear fuel assemblies) have been resolved. This report documents the as-built imager, first measurements performed with it, and tomographic reconstructions performed using the measured data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pattern Recognition: The Importance of Dispersion in Crystal Collimation

One aspect of the upcoming CRYSTAL experiment is to study the dynamics of single protons circulating the SPS in the presence of a crystal. Under some circumstances (for example under crystal channeling) a proton may hit the crystal and the neighboring silicon strip position detectors only once, before extraction from the SPS. In general (at most crystal rotation angles) it is expected that single protons will hit the crystal many times, with many accelerator turns between each hit, before escaping. Intermediate regimes are also possible (for example under volume reflection) in which a proton hits the crystal only a few times over many turns before being lost. It is crucial that the data analysis of each single proton data set be able to distinguish between these different dynamical phases, and to be able to convincingly demonstrate that the fundamental processes at play in each phase are well understood. Distinguishing between dynamical phases depends crucially on the ability to perform pattern recognition--at least visually, but preferably quantitatively--on the single proton data sets. This note shows that synchrotron oscillations significantly affect the hit pattern of a proton on the crystal. (By hit pattern we mean either the measurement vector of turn number and penetration depth, for each proton, or a vector that can be directly derived from the measurement vector, such as the vector of inferred synchrotron phase and penetration depth.) The analysis is (deliberately) as rudimentary as possible, using an elementary linear calculation which neither includes any higher order effects in the accelerator, nor any dynamical interactions between the test proton and the crystal or the silicon detectors. Single particle simulation studies need to be carried out for CRYSTAL, exploring realistic effects besides dispersion, such as multiple scattering, dead zones, energy loss, dispersion slope, and linear coupling. Only after analysis software becomes available to interpret the output of such studies will it be possible to predict with any confidence that it will be possible to distinguish all single proton dynamical phases in the CRYSTAL experiment. Then reality will prevail.

43 PARTICLE ACCELERATORS↗

MARS15-Based System for Beam Loss and Collimation Studies

The system includes the newest version of the MARS15 code for particle production and transport in accelerator components integrated with a novel highprecision tracker/stepper for multi-turn tracking merged with MAD-X. The overall approach is described with all the essential features and programming issues highlighted. The application is illustrated for the Fermilab Recycler Ring and Integrable Optics Test Accelerator (IOTA) facilities as well as for the Higgs Factory muon collider and International $e^+e^−$ Linear Collider (ILC) projects.

43 PARTICLE ACCELERATORS↗