Search NASA⌕ Search

SEARCH · Search NASA

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Retrieval of Water Vapor Column Abundance and Aerosol Properties from ChemCam Passive Sky Spectroscopy

We derive water vapor column abundances and aerosol properties from Mars Science Laboratory (MSL) ChemCam passive mode observations of scattered sky light. This paper covers the methodology and initial results for water vapor and also provides preliminary results for aerosols. The data set presented here includes the results of 113 observations spanning from Mars Year 31 L(s) = 291 deg (March 30, 2013) to Mars Year 33 L(s) = 127 deg (March 24, 2016). Each ChemCam passive sky observation acquires spectra at two different elevation angles. We fit these spectra with a discrete-ordinates multiple scattering radiative transfer model, using the correlated-k approximation for gas absorption bands. The retrieval proceeds by first fitting the continuum of the ratio of the two elevation angles to solve for aerosol properties, and then fitting the continuum-removed ratio to solve for gas abundances. The final step of the retrieval makes use of the observed CO 2 absorptions and the known CO 2 abundance to correct the retrieved water vapor abundance for the effects of the vertical distribution of scattering aerosols and to derive an aerosol scale height parameter. Our water vapor results give water vapor column abundance with a precision of +/-0.6 precipitable microns and systematic errors no larger than +/-0.3 precipitable microns, assuming uniform vertical mixing. The ChemCam-retrieved water abundances show, with only a few exceptions, the same seasonal behavior and the same timing of seasonal minima and maxima as the TES, CRISM, and REMS-H data sets that we compare them to. However ChemCam-retrieved water abundances are generally lower than zonal and regional scale from-orbit water vapor data, while at the same time being significantly larger than pre-dawn REMS-H abundances. Pending further analysis of REMS-H volume mixing ratio uncertainties, the differences between ChemCam and REMS-H pre-dawn mixing ratios appear to be much too large to be explained by large scale circulations and thus they tend to support the hypothesis of substantial diurnal interactions of water vapor with the surface. Our preliminary aerosol results, meanwhile, show the expected seasonal pattern in dust particle size but also indicate a surprising interannual increase in water-ice cloud opacities.

Mcconnochie, Timothy H.↗

Top-Down NOx Emissions of European Cities Based on the Downwind Plume of Modelled and Space-Borne Tropospheric NO2 Columns

Top-down estimates of surface NOX emissions were derived for 23 European cities based on the downwind plume decay of tropospheric nitrogen dioxide (NO2) columns from the LOTOS-EUROS (Long Term Ozone Simulation-European Ozone Simulation) chemistry transport model (CTM) and from Ozone Monitoring Instrument (OMI) satellite retrievals, averaged for the summertime period (April-September) during 2013. Here we show that the top-down NOX emissions derived from LOTOS-EUROS for European urban areas agree well with the bottom-up NOX emissions from the MACC-III inventory data (R(exp 2) = 0.88) driving the CTM demonstrating the potential of this method. OMI top-down NOX emissions over the 23 European cities are generally lower compared with the MACC-III emissions and their correlation is slightly lower (R(exp 2) = 0.79). The uncertainty on the derived NO2 lifetimes and NOX emissions are on average ~55% for OMI and ~63% for LOTOS-EUROS data. The downwind NO2 plume method applied on both LOTOS-EUROS and OMI tropospheric NO2 columns allows to estimate NOX emissions from urban areas, demonstrating that this is a useful method for real-time updates of urban NOX emissions with reasonable accuracy.

NOx emissions↗

Portable, Low-Cost, Column Carbon Dioxide and Methane Measurements for Validating Satellite Observations in Remote Locations

We present a low-cost (~$10K per instrument), portable solution to ground-based validation of satellite observations for difficult to reach locations with precisions of 1 ppm XCO2 and 10 ppb XCH4 for hourly data products. While Total Carbon Column Observing Network (TCCON) is the gold-standard for ground validation, there are locations where a ground column validation data point would be useful but conditions are not conducive to a permanent station. Examples include wetlands, thawing permafrost, the tropics, the Amazon, sub-Saharan Africa, as well as locations without a power grid or with geopolitical conflict. In addition, the low-cost and portability mean a geographical region can be studied in depth with multiple instruments. This passive, sun-pointing instrument is a miniaturized, laser heterodyne radiometer (mini-LHR) that has been under development by our team since 2009. It can be operated either in tandem with AERONET (a global network of 500 instruments that measure aerosol optical depth), or as a stand-alone instrument with a low-cost (~$3K), light-weight sun tracker. One of the main benefits of the mini-LHR is that it can quickly reach remote locations and provide a validation measurement even if there is limited or no infrastructure at the site. The instrument weighs ~10 lbs, fits into a backpack, and is powered by two folding solar panels and a battery pack. In clear conditions, the instrument can be set-up in under an hour. Portability means that mini-LHRs can be easily moved for side-by-side comparisons with other mini-LHRs and with TCCON which simplifies assessing instrument bias as well as accuracy. Like TCCON, the mini-LHR points directly at the sun with a narrow field-of-view and is its insensitivity to cloud and aerosol scattering that is common to nadir-pointing passive satellite approaches. Here we present a collection of sample data sets to demonstrate performance from locations that vary in climate, altitude, solar zenith angle, hours of sun per day, etc., as well as data from side-by-side TCCON comparisons. Retrievals of CO2 and CH4 were completed using the NASA/Goddard's Planetary Spectrum Generator (PSG) that incorporates meteorological inputs from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) data set.

Wilson, Emily W.↗

Water Vapor Column Measurements with Infrared Active Optical IPDA Lidar

Development of a novel triple-pulsed 2-μm direct detection Integrated Path Differential Absorption (IPDA) lidar to measure column average carbon dioxide (XCO2) and water vapor (XH2O) from an airborne platform provides a new tool to advance atmospheric science studies. Column water vapor measurements are used in global mapping of weather fronts, weather forecast, and in studies of atmospheric transport, radiation, clouds and climate. Water vapor interference is source of biases in XCO2 measurements due to overlap in absorption, line broadening, and retrieval of dry air mixing of carbon dioxide. Model calculations show a XH2O measurement capability of 0.5% accuracy over 1.0 km spatial scales from the NASA B-200 aircraft. Ground testing of the integrated IPDA was in progress during December 2017-January 2018, and airborne measurements and validation of XH2O measurements over land and ocean are planned during January-February 2018. Technology developments in the measurement of XH2O are presented along with performance projections, and results from ground and airborne testing and validations in this paper.

Singh, Upendra N.↗

Version 2 Ozone Monitoring Instrument SO2 Product (OMSO2 V2): New Anthropogenic SO2 Vertical Column Density Dataset

The Ozone Monitoring Instrument (OMI) has been providing global observations of SO2 pollution since 2004. Here we introduce the new anthropogenic SO2 vertical column density (VCD) dataset in the version 2 OMI SO2 product (OMSO2 V2). As with the previous version (OMSO2 V1.3), the new dataset is generated with an algorithm based on principal component analysis of OMI radiances, but features several updates. The most important among those is the use of expanded lookup tables and model a priori profiles to estimate SO2 Jacobians for individual OMI pixels, in order to better characterize pixel-to-pixel variations in SO2 sensitivity, including over snow and ice. Additionally, new data screening and spectral fitting schemes have been implemented to improve the quality of the spectral fit. As compared with the planetary boundary layer SO2 dataset in OMSO2 V1.3, the new dataset has substantially better data quality, especially over areas that are relatively clean or affected by the south Atlantic anomaly. The updated retrievals over snow/ice yield more realistic seasonal changes in SO2 at high latitudes and offer enhanced sensitivity to sources during wintertime. An error analysis has been conducted to assess uncertainties in SO2 VCDs from both the spectral fit and Jacobian calculations. The uncertainties from spectral fitting are reflected in SO2 slant column densities (SCDs) and largely depend on the signal-to-noise ratio of the measured radiances, as implied by the generally smaller SCD uncertainties over clouds or for smaller solar zenith angles. The SCD uncertainties for individual pixels are estimated to be~0.15-0.3 DU (Dobson Units) between ~40°S and ~40°N and to be~0.2-0.5 DU at higher latitudes. The uncertainties from the Jacobians are approximately ~50-100% over polluted areas, and primarily attributed to errors in SO2 a priori profiles and cloud pressures, as well as the lack of explicit treatment for aerosols. Finally, the daily mean and median SCDs over the presumably SO2-free equatorial East Pacific have increased by only~0.0035 DU and ~0.003 DU respectively over the entire 15-year OMI record; while the standard deviation of SCDs has grown by only~0.02 DU or ~10%. Such remarkable long-term stability makes the new dataset particularly suitable for detecting regional changes in SO2 pollution.

OMI, SO2, Remote Sensing↗

Thermal cycling testing to failure of a ceramic column grid array package for space applications

Ceramic column grid array (CCGA) packages have been used increasingly in logic and microprocessor functions, telecommunications, flight avionics boards, payload electronics boards, engineering navigational and science cameras, electronic assemblies, and other applications, because of their inherent advantages such as high electrical interconnect density, very good thermal and electrical performance, and compatibility with standard surface-mount technology (SMT) packaging assembly processes. Because these advanced electronic packages tend to have less solder-joint strain-relief than do leaded flat-pack electronic packages, the reliability of CCGA packages in challenging thermal environments is a very important consideration for their short- and long-term use in JPL-NASA space missions. In this study, we assembled daisy chains of polyimide printed wiring boards from CCGA-interconnect packages, inspected the boards nondestructively, and then subjected them to thermal cycling to assess their reliability in thermal environments from +125°C to -40°C±25°C. The test hardware consists of a CCGA 1752 package (CN version). The package was divided into four daisy-chained sections that were electrically monitored for their continuity during thermal cycling. The CCGA 1752 package is roughly 45 mm × 45 mm with a 42-mm × 42-mm array of 80%/20% Pb/Sn columns on a 1.00-mm pitch. The resistance of the daisy-chained CCGA interconnects was continuously monitored during thermal cycling in a gaseous nitrogen environment. Electrical continuity resistance measurements as a function of thermal cycling are reported here; tests to date have shown significant change to an open circuit in daisy-chain resistance as a function of thermal cycling. The change in interconnect resistance becomes increasingly noticeable with increasing number of thermal cycles. This paper describes the experimental thermal-cycling test results of CCGA 1752 package reliability testing under an extremely wide temperature range. The first failure was observed at 1479th thermal cycle. We report the thermal-cycle reliability test data for ~2500 thermal cycles.

Ramesham, Rajeshuni↗

Retrieval Algorithm for the Column CO2 Mixing Ratio from Pulsed Multi-Wavelength Lidar Measurements

The retrieval algorithm for the column mixing ratio of CO2 from the measurements of a pulsed multi-wavelength integrated path differential absorption (IPDA) lidar is described. The lidar samples the shape of the 1572.33 nm CO2 absorption line at 15 or 30 wavelengths. The algorithm uses a least-squares fit between the CO2 line shape computed from a layered 10 atmosphere model to that sampled by the lidar. In addition to the column average CO2 dry air mole fraction (XCO2), several other parameters are also solved simultaneously from the fit. These include the Doppler shift in the received laser signal wavelengths, the product of the surface reflectivity and atmospheric transmission and a linear trend in the lidar receiver’s spectral response. The algorithm can also be used to solve for the average water vapor mixing ratio, which causes a secondary absorption in the wings of the CO2 absorption line under high humidity conditions. The least-squares fit is linearized about the 15 expected XCO2 value which allows the use of a standard linear least-squares fitting method and software tools. The standard deviation of the retrieved XCO2 is obtained from covariance matrix of the fit. An averaging kernel is defined similarly to that used for passive trace-gas sounding. Examples are presented of using the algorithm to retrieve XCO2 from the measurements from NASA Goddard’s airborne CO2 Sounder lidar made at a constant altitude and during spiral-down maneuvers.

Xiaoli Sun↗

Global Distribution and 14-Year Changes in Erythemal Irradiance, UV Atmospheric Transmission, and Total Column Ozone 2005 – 2018 Estimated from OMI and EPIC Observations

Satellite data from the Ozone Measuring Instrument (OMI) and Earth Polychromatic Imaging Camera (EPIC) are used to study changes and global distribution of UV erythemal irradiance in mW/m(exp 2) E(ζ,φ,z,t) and the dimensionless UV index (E/25 mWm(exp 2)) over the Earth’s surface as a function of latitude ζ, longitude φ, altitude z, and time t. OMI time series data starting in January 2005 to December 2018 are used to estimate 14-year changes in erythemal irradiance, total column ozone TCO3, scene reflectivity LER, and aerosol absorption τA at specific land sites in the Northern and Southern Hemispheres using publicly available OMI data. Estimates of changes in atmospheric transmission ΔCτ(ζ,φ,z,t) derived from OMI measured cloud and haze reflectivity show an increase between 60°S to 45°S almost no average 14-year change from 55°S to 30°N but show an increase from 35°N to 55°N. This implies increased solar insolation at higher latitudes that suggests positive feedback for global warming. Changes in aerosol absorption of UV irradiance ΔCA(ζ,φ,z,t) derived from changes in τA are mostly in the equatorial region and at higher southern latitudes resulting in correlated changes in E. TCO3 derived from OMI data has increased at a rate of 2% per decade for the latitudes between 60°S to 10°N changing to a decrease of 1% per decade between 40°N to 60°N. The result is an average decrease in E(ζ,φ,z,t) at a rate of 2% per decade in the Southern Hemisphere and an increase between 40°N to 60°N. For some specific sites (latitudes from 55°S to 45°N) there has been little or no change in E(ζ,φ,z,t) for the period 2005 – 2018. Nearly half the sites show strong correlation effects of both short- and long-term cloud and absorbing aerosol change as well as anticorrelation with total column ozone change ΔTCO3. Synoptic EPIC data from the sunlit Earth are used to derive ozone and reflectivity needed for global images of the distribution of E(ζ,φ,z,t) from sunrise to sunset centered on the Americas, Europe-Africa, and Asia. EPIC data are used to show the latitudinal distribution of E(ζ,φ,z,t) from the equator to 75° for specific longitudes. Dangerously high amounts of erythemal irradiance (12 < UV index < 18) are found for many low latitude and high-altitude sites (e.g., San Pedro, Chile (2.45 km), La Paz, Bolivia (3.78 km). Lower UV indices at some equatorial or high-altitude sites (e.g., Quito, Ecuador) are moderated by the presence of persistent cloud effects. High UVI levels (UVI > 6) are also found at most mid-latitude sites during the summer months.

Ozone Measuring Instrument (OMI) and Earth Polychr↗

On the Stability and Phase Behavior of Titan's Subsurface Liquid Columns

On Titan, liquid hydrocarbon may stay in the subsurface porous permeable crust known as the alkanofer, analogous to water in Earth’s aquifer. In addition to pressure gradient, the subsurface liquid in alkanofers is subject to vertical compositional grading due to the gravity and temperature gradient. The common wisdom is that the liquid would normally stay underground in a stability established by the pressure that increases with depth as observed in aquifers on Earth. However, Titan’s liquids consist of nitrogen and hydrocarbons, mainly methane and ethane, the behavior of which is very sensitive to temperature and pressure. Consequently, the liquid density does not always increase with depth, thus may introduce a reverse density profile that leads to vertical convective instability of the liquid column. If reverse density profiles are present, capillary pressures arising from liquid trapped within small pores in the crust can help with the column stability. The liquid held in the capillaries can seal the space below it thus helping with the stability, unless the overpressure built from underneath becomes larger than the capillary pressure, which causes leakage to allow the liquids to seep upward from the deep. This situation is analogous to hydrocarbon seeps on Earth, where oil and natural gas escape the reservoir and flow slowly through network of cracks to the surface. An algorithm based on an extended Gibbs equation commonly used in petroleum reservoir engineering is employed in this work to produce pressure, density, and compositional profiles for evaluating the stability and phase behavior of Titan’s subsurface fluids.

Sugata Tan↗

Column Optical Depth (COD) Derived from CALIOP Ocean Surface Returns

The Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) on board the Cloud Aerosol Lidar Infrared Pathfinder Satellite Observations (CALIPSO) satellite has been making near-global measurements of clouds and aerosols since mid-June 2006. Among the properties reported in CALIPSO data products are estimates of total column optical depth (COD) obtained by integrating the retrieved extinction coefficients of detected particulates (i.e., aerosols and clouds) from 36 km to the surface. However, due to algorithm detection limits and instrument sensitivities, particulates can go undetected when the particulate loading is especially diffuse or in regions where the signal is attenuated by over-lying layers. Because extinction is not calculated where features are not detected, these undetected particulates can introduce low biases into the reported COD. Lidar ratio assumptions used in the extinction retrievals can also introduce errors. To minimize these biases, future releases of the CALIPSO lidar data products will implement an ocean-derived column optical depth (ODCOD) retrieval. The following paper briefly describes the algorithm, the current status of the algorithm development and verification efforts, and preliminary comparisons to col-located COD estimates derived using other retrieval schemes and obtained from other sensors.

Robert A Ryan↗

Using CALIPSO's New Ocean Derived Column Optical Depths

CALIPSO’s Version 4.51 Level 2 data release introduces an all-new group of science data sets containing estimates of total column two-way transmittances and effective optical depths derived from CALIOP ocean surface backscatter measurements and MERRA-2 reanalysis wind speed data. These estimates use data from the standard CALIOP lidar signal but in a passive sensor-like way, thus creating a unique link to passive instrument measurements. These new retrievals are provided for the entire mission, day and night, at 532nm, and are reported at single shot, 1km, and 5km resolutions for all profiles in which a valid lidar ocean surface return is detected. The addition of a total column optical depth constraint on subsequent retrievals of cloud and aerosol optical properties opens the door for many exciting new ways to leverage the already rich and versatile CALIPSO dataset. Following a brief review of the retrieval technique, this talk will focus on quality assurance assessments, estimated uncertainties, and data usage scenarios. We will conclude with examples highlighting some of the exciting work already being done using this new addition to CALIPSO’s already rich data record.

R Ryan↗

Updated assessment of TROPOMI NO2 and HCHO columns using airborne spectrometers during the MOOSE and TRACER-AQ field campaigns

Airborne spectrometer data offers the opportunity to evaluate satellite product performance without the impact of subpixel heterogeneity between the different satellite and ground-based measurement footprints. Previous measurements during the Long Island Sound Tropospheric Ozone Study were used to evaluate TROPOMI’s v1.3 NO2 product and found very strong relationships (r2=0.96) between the airborne spectrometer and TROPOMI with a systematic low bias mostly attributed to the coarse a priori profile assumption within the standard TROPOMI retrieval. This presentation will update that analysis using the most up-to-date version 2 TROPOMI NO2 product as well as expand analysis to the HCHO product. In summer 2021, NASA GeoCAPE Airborne Simulator (GCAS) collected measurements over southeast Michigan/western Ontario for the Michigan-Ontario Ozone Source Experiment (MOOSE) and Houston, Texas during the TRacking Aerosol Convection ExpeRiment – Air Quality (TRACER-AQ). Flight strategies for both deployments included repeated systematic sampling over common areas of interest coinciding with TROPOMI. During these flights, GCAS NO2 tropospheric columns are available at 250 m x 560 m resolution. Preliminary evaluation of GCAS NO2 retrievals with Pandora spectrometer data in Houston, Texas (3 sites) shows a median percent difference of 1.4% with an interquartile range of -15.5-14.9% (r2=0.72). Column HCHO was also retrieved at a slightly coarser resolution in Houston, Texas (750 m x 1680 m) showing distinct spatial patterns associated with secondary production through the oxidation of VOCs downwind of industrial facilities. Comparison to Pandora HCHO showed a low bias of ~25% (r2=0.29) with further investigation needed to identify the cause for this bias. This presentation will share how the GCAS/Pandora/TROPOMI NO2 and HCHO intercompare and will also extend analysis toward thinking about how these assets will contribute to the validation of future geostationary observations.

Laura Judd↗

Comparing Low-Cost Sensors with Ground-Based and Airborne In-Situ and Column Observations of NO2 and HCHO during the FRAPPE Field Campaign in Colorado, USA

Even in the presence of more reliable air quality tools, low-cost sensors have the benefit of recording data on highly localized spatial and temporal scales, allowing for multiple measurements within a single satellite pixel and on pixel boundaries. However, they are less accurate than their regulatory-grade counterparts, requiring regular co-locations with accepted instruments to ensure their validity. Thus, the addition of low-cost sensors to a field campaign – where reference-grade air quality instruments are abundant – not only provides ample opportunities for low-cost sensor co-location and calibration, but also allows the low-cost instruments to be used for sub-pixel validation, covering more surface area than the regulatory instruments alone with a network of sensors. During the summer of 2014, our low-cost sensor network was deployed during the Front Range Air Pollution and Photochemistry Experiment (FRAPPÉ) campaign conducted to sample the composition of air at and above ground level in northeastern Colorado, USA. The low-cost sensor platform included a suite of gas-phase sensors, notably NO2 and two generalized volatile organic compound (VOC) sensors, which were leveraged together to quantify speciated hydrocarbons such as formaldehyde. These key pollutants were chosen for their impacts on human health and climate change, as well as their inclusion on the TEMPO satellite launching this year. Airborne campaign measurements included slant column optical observations of formaldehyde (HCHO), nitrogen dioxide (NO2), and ozone (O3). Myriad additional in-situ instruments described chemical composition up to approximately 5 km above surface level. Ground-based instrumentation included both stationary and mobile regulatory-grade instruments, which were used for sensor calibration. Machine learning techniques such as artificial neural networks (ANNs) were used to match the low-cost signals to that of the reference-grade instruments. Here, we compare calibrated low-cost sensor data collected at ground level in a variety of locations along Colorado’s Front Range to various data sources from the FRAPPÉ campaign to better understand how well airborne and regulatory ground-based measurements can be extrapolated to other locations. Further, as the slant column measurements act as satellite simulators, we explore how low-cost instruments can be used for satellite validation purposes. Comparisons among these different data types also have important implications in data fusion.

Kristen Okorn↗

Using Orbiting Carbon Observatory-2 (OCO-2) column CO2 retrievals to rapidly detect and estimate biospheric surface carbon flux anomalies

The global carbon cycle is experiencing continued perturbations via increases in atmospheric carbon concentrations, which are partly reduced by terrestrial biosphere and ocean carbon uptake. Greenhouse gas satellites have been shown to be useful in retrieving atmospheric carbon concentrations and observing surface and atmospheric CO2 seasonal-to-interannual variations. However, limited attention has been placed on using satellite column CO2 retrievals to evaluate surface CO2 fluxes from the terrestrial biosphere without advanced inversion models at low latency. Such applications could be useful to monitor, in near real time, biosphere carbon fluxes during climatic anomalies like drought, heatwaves, and floods, before more complex terrestrial biosphere model outputs and/or advanced inversion modelling estimates become available. Here, we explore the ability of Orbiting Carbon Observatory-2 (OCO-2) column-averaged dry air CO2 (XCO2) retrievals to directly detect and estimate terrestrial biosphere CO2 flux anomalies using a simple mass-balance approach. An initial global analysis of surface–atmospheric CO2 coupling and transport conditions reveals that the western US, among a handful of other regions, is a feasible candidate for using XCO2 for detecting terrestrial biosphere CO2 flux anomalies. Using the CarbonTracker model reanalysis as a test bed, we first demonstrate that a well-established mass-balance approach can estimate monthly surface CO2 flux anomalies from XCO2 enhancements in the western United States. The method is optimal when the study domain is spatially extensive enough to account for atmospheric mixing and has favorable advection conditions with contributions primarily from one background region. We find that errors in individual soundings reduce the ability of OCO-2 XCO2 to estimate more frequent, smaller surface CO2 flux anomalies. However, we find that OCO-2 XCO2 can often detect and estimate large surface flux anomalies that leave an imprint on the atmospheric CO2 concentration anomalies beyond the retrieval error/uncertainty associated with the observations. OCO-2 can thus be useful for low-latency monitoring of the monthly timing and magnitude of extreme regional terrestrial biosphere carbon anomalies.

Andrew F. Feldman↗

Multiplexed Oversampling Digitizer in 65 nm CMOS for Column-Parallel CCD Readout

A digitizer designed to read out column-parallel charge-coupled devices (CCDs) used for high-speed X-ray imaging is presented. The digitizer is included as part of the High-Speed Image Preprocessor with Oversampling (HIPPO) integrated circuit. The digitizer module comprises a multiplexed, oversampling, 12-bit, 80 MS/s pipelined Analog-to-Digital Converter (ADC) and a bank of four fast-settling sample-and-hold amplifiers to instrument four analog channels. The ADC multiplexes and oversamples to reduce its area to allow integration that is pitch-matched to the columns of the CCD. Novel design techniques are used to enable oversampling and multiplexing with a reduced power penalty. The ADC exhibits 188 ?V-rms noise which is less than 1 LSB at a 12-bit level. The prototype is implemented in a commercially available 65 nm CMOS process. The digitizer will lead to a proof-of-principle 2D 10 Gigapixel/s X-ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic testing device having an adjustable water column

An ultrasonic testing device having a variable fluid column height is disclosed. An operator is able to adjust the fluid column height in real time during an inspection to to produce optimum ultrasonic focus and separate extraneous, unwanted UT signals from those stemming from the area of interest.

42 ENGINEERING↗

Column Testing and 1D Reactive Transport Modeling to Evaluate Uranium Plume Persistence Processes

Motivation for Study: Natural flushing of contaminants at various U.S. Department of Energy Office of Legacy Management sites is not proceeding as quickly as predicted (plume persistence) Objectives: Help determine natural flushing rates using column tests. Use 1D reactive transport modeling to better understand the major processes that are creating plume persistence Approach: Core samples from under a former mill tailings area Tailings have been removed. Column leaching using lab-prepared water similar to nearby Gunnison River water. 1D reactive transport modeling to evaluate processes

54 ENVIRONMENTAL SCIENCES↗

Sealed micro gas chromatography columns and methods thereof

The present application relates to microfabricated columns having a sealed flow channel. In particular, the channel is sealed during dicing, thereby preventing debris from accumulating within channels. In use, the seal is ruptured mechanically to connect one or more fluidic connections, which deliver analytes to the flow channel. Additional details are provided for making and using sealed columns.

Moorman, Matthew W.↗