Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Design, fabrication and performance of two grazing incidence telescopes for celestial extreme ultraviolet astronomy

The design and performance of grazing incidence telescopes for celestial extreme ultraviolet (EUV) astronomy are described. The telescopes basically consist of a star tracker, collimator, grazing incidence mirror, vacuum box lid, vacuum housing, filters, a ranicon detector, an electronics box, and an aspect camera. For the survey mirror a Wolter-Schwarzschild type II configuration was selected. Diamond-turning was used for mirror fabrication, a technique which machines surfaces to the order of 10 microns over the required dimensions. The design of the EUV spectrometer is discussed with particular reference to the optics for a primarily spectroscopic application and the fabrication of the f/10 optics.

Lampton, M.↗

The application of digital signal processing techniques to a teleoperator radar system

A digital signal processing system was studied for the determination of the spectral frequency distribution of echo signals from a teleoperator radar system. The system consisted of a sample and hold circuit, an analog to digital converter, a digital filter, and a Fast Fourier Transform. The system is interfaced to a 16 bit microprocessor. The microprocessor is programmed to control the complete digital signal processing. The digital filtering and Fast Fourier Transform functions are implemented by a S2815 digital filter/utility peripheral chip and a S2814A Fast Fourier Transform chip. The S2815 initially simulates a low-pass Butterworth filter with later expansion to complete filter circuit (bandpass and highpass) synthesizing.

Pujol, A.↗

Design and performance of the cryogenic focal plane optics assembly for the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has successfully completed its mission of providing an unbiased all-sky survey of astronomical objects in the 8 to 120 micrometer wavelength region. The design and performance of the Focal Plane Optics Assembly (FPOA) for the IRAS instrument is described in this paper. The FPOA consists of 62 survey field stops, 62 individual small field lenses, 124 small spectral filters, and a precision multi-part aluminum housing. The FPOA is capable of repeated thermal cycling from ambient temperature to 2 Kelvin. The spectral filters, along with the detector spectral responses, provide infrared bandpasses of 8-15, 18-30, 46-78, and 85-117 micrometers. The combination of very long wavelengths, liquid helium temperatures, and small size provided a significant design challenge. Spectral filter and field lens designs for the four spectral bands are described. Also, discussed are techniques which were developed for mechanical mounting of the small lenses and spectral filters, and to assure their optical alignment.

Bamberg, J. A.↗

Annular denuders for use in global climate and stratospheric measurements of acidic gases and particles

Measurements of acidic and basic gases that coexist with fine particle (less than 2.5 micron) may be useful for determining the impact of these species on global climate changes and determining species that influence stratospheric ozone levels. Annular denuders are well suited for this purpose. A new concentric annular denuder system, consisting of a three channel denuder, a Teflon coated cyclone preseparator, and a multistage filter pack was developed, evaluated, and shown to provide reliable atmospheric measurements of SO2, HNO2, HNO3, NH3, SO4(=), NH4(+), NO3(-), and H(+). For example, the precision of the annular denuder for the ambient measurements of HNO3 and nitrates at concentrations between 0.1 to 3 microgram/cu m was + or - 12 and 16 pct., respectively. The 120 x 25 mm three channel denuder is encased in a stainless steel sheath and has annular spaces that are 1 mm wide. This design was shown to have nearly identical capacity for removal of SO2 as conventional 210 x 25 mm single channel denuder configurations. The cyclone preseparator was designed and tested to have a D sub 50 cutoff diameter of 2.5 micron and minimal retention of HNO3.

Stevens, Robert K.↗

Some observations on spin detector response during Galileo high gain antenna deployment

This paper summarizes a dynamic analysis conducted in support of the investigation of the anomalous deployment of the Galileo High Gain Antenna on April 11, 1991. The work was focused on modeling the spacecraft spin dynamics to predict and compare the spin detector telemetry during the antenna deployment for possible cause scenarios. The effects of analog and digital low-pass filtering, digitization, and telemetry on the reported spin rate were studied as well. The high frequency phenomena in the spin detector response are masked by the filtering and sampling of the telemetry data. However, the observed spin detector telemetery is consistent with a single rib popping free, and is most likely associated with a rib near the spin detector, or 180 deg opposite.

Peng, Chia-Yen↗

An X-Band Mixer Engineered for 77 K Operation

An X-band Si-diode singly balanced mixer developed specifically for cryogenic operation is presented. In order to reduce thermal demands on a mechanical cooler, the mixer was designed to operate with a minimum of local oscillator (LO) power. That is, since the LO had to be cooled to reduce phase noise, it was desirable to minimize the LO drive. Novel embedding circuit strategy was responsible for nearly theoretical performance. The signal-matching circuit simultaneously provided a reactive termination to the image, sum, and first, second, and third LO harmonic frequencies. A conversion loss of 3.2 dB at 77 K with an LO drive of +1 dBm was measured. This loss included IF filter, dc block, and hybrid coupler losses. Mixer conversion loss is shown to be consistent with the theoretical performance limit expected from the intrinsic diode. The relationship among junction capacitance, flat-band potential, and conversion loss is examined.

Romanofsky, Robert R.↗

New Research by CCD Scanning for Comets and Asteroids

Spacewatch was begun in 1980; its purpose is to explore the various populations of small objects within the solar system. Spacewatch provides data for studies of comets and asteroids, finds potential targets for space missions, and provides information on the environmental problem of possible impacts. Moving objects are discovered by scanning the sky with charge-coupled devices (CCDS) on the 0.9-meter Spacewatch Telescope of the University of Arizona on Kitt Peak. Each Spacewatch scan consists of three drift scan passes over an area of sky using a CCD filtered to a bandpass of 0.5-1.0 pm (approximately V+R+I with peak sensitivity at 0.7 pm). The effective exposure time for each pass is 143 seconds multiplied by the secant of the declination. The area covered by each scan is 32 arcminutes in declination by about 28 minutes of time in right ascension. The image scale is 1.05 arcseconds per pixel. Three passes take about 1.5 hours to complete and show motions of individual objects over a one hour time baseline. The limiting magnitude is about 21.5 in single scans. CCD scanning was developed by Spacewatch in the early 1980s, with improvements still being made - particularly by bringing a new 1.8-m Spacewatch Telescope on line. In the meantime, we have been finding some 30,000 new asteroids per year and applying their statistics to the study of the collisional history of the solar system. Spacewatch had found a total of 150 Near-Earth Asteroids (NEAS) and 8 new comets, and had recovered one lost comet (P/Spitaler in 1993). Spacewatch is also efficient in recovery of known comets and has detected and reported positions for more than 137,000 asteroids, mostly new ones in the main belt, including more than 10,882 asteroids designated by the Minor Planet Center (MPC).

Gehrels, Tom↗

New Research by CCD Scanning for Comets and Asteroids

The purpose of Spacewatch is to explore the various populations of small objects within the solar system. Spacewatch provides data for studies of comets and asteroids, finds potential targets for space missions, and provides information on the environmental problem of possible impacts. Moving objects are discovered by scanning the sky with charge-coupled devices (CCDs) on the 0.9-meter Spacewatch Telescope of the University of Arizona on Kitt Peak. Each Spacewatch scan consists of three drift scan passes over an area of sky using a CCD filtered to a bandpass of 0.5-1.0 microns (approximately V+R+I with peak sensitivity at 0.7 micron). The effective exposure time for each pass is 143 seconds multiplied by the secant of the declination. We have been finding some 30,000 new asteroids per year and applying their statistics to the study of the collisional history of the solar system. As of the end of the observing run of Nov. 1997, Spacewatch had found a total of 153 Near-Earth Asteroids (NEAs) and 8 new comets since the project began in the 1980s, and had recovered one lost comet. The total number of NEAs found by Spacewatch big enough to be hazardous if they were to impact the Earth is 36. Spacewatch is also efficient in recovery of known comets and has detected and reported positions for more than 137,000 asteroids, mostly new ones in the main belt, including more than 16,000 asteroids designated by the Minor Planet Center (MPC).

Gehrels, Tom↗

Compact Efficient Lidar Receiver for Measuring Atmospheric Aerosols

A small, light weight, and efficient aerosol lidar receiver was constructed and tested. Weight and space savings were realized by using rigid optic tubes and mounting cubes to package the steering optics and detectors in a compact assembly. The receiver had a 1064nm channel using an APD detector. The 532nm channel was split (90/10) into an analog channel (90%) and a photon counting channel (10%). The efficiency of the 1064nm channel with optical filter was 44.0%. The efficiency of the analog 532nm channel was 61.4% with the optical filter, and the efficiency of the 532nm photon counting channel was 7.6% with the optical filter. The results of the atmospheric tests show that the detectors were able to consistently return accurate results. The lidar receiver was able to detect distinct cloud layers, and the lidar returns also agreed across the different detectors. The use of a light weight fiber-coupled telescope reduced weight and allowed great latitude in detector assembly positioning due to the flexibility enabled by the use of fiber optics. The receiver is now ready to be deployed for aircraft or ground based aerosol lidar measurements.

Gili, Christopher↗

Determination of Ceres Physical Parameters Using Radiometric and Optical Data

The Dawn spacecraft was launched on September 27th, 2007. Its mission is to rendezvous with and observe the two largest bodies in the main asteroid belt, Vesta and Ceres. It has completed over a year’s worth of direct observations of Vesta from early 2011 through late 2012. In the spring of 2015, the Dawn spacecraft entered orbit around the asteroid Ceres for the start of what is expected to be more than a year of science operations. The science data collected from this encounter consist of infrared (IR) images and spectra, visible images through a number of color filters, gamma ray detections and measurements of the Ceres gravity field. These data will be collected during several science phases: an Approach phase (1500000-4860 km from Ceres), a Survey orbit (4860 km radius), a High Altitude Mapping Orbit (HAMO) (1940 km radius) and a Low Altitude Mapping Orbit (LAMO) (855 km radius). The Approach phase included three Rotational Characterization (RC) opportunities. Designing each science orbit and successfully transferring into that orbit requires a sufficiently accurate estimate of Ceres physical parameters (body fixed frame, GM and harmonics). This paper focuses on work performed to estimate Ceres physical parameters using Deep Space Network (DSN) radiometric tracking data and optical measurements derived from science camera imagery. This paper describes planning for the data acquisition, as well as processing techniques and methodology. The trajectories predicted by the gravity field estimations are also compared with the actual as-flown trajectories. Observations of the gravity at high altitudes are found to be sufficient to design precision orbits at lower altitudes. Follow-up analysis after successfully reaching LAMO is included, as is a discussion of lessons learned.

Kennedy, Brian M.↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/ absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

Euclid Near Infrared Spectro Photometer instrument concept and first test results obtained for different breadboards models at the end of phase C

The Euclid mission objective is to understand why the expansion of the Universe is accelerating through by mapping the geometry of the dark Universe by investigating the distance-redshift relationship and tracing the evolution of cosmic structures. The Euclid project is part of ESA's Cosmic Vision program with its launch planned for 2020 (ref [1]). The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments and is operating in the near-IR spectral region (900- 2000nm) as a photometer and spectrometer. The instrument is composed of: - a cold (135K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly (corrector and camera lens), a filter wheel mechanism, a grism wheel mechanism, a calibration unit and a thermal control system - a detection subsystem based on a mosaic of 16 HAWAII2RG cooled to 95K with their front-end readout electronic cooled to 140K, integrated on a mechanical focal plane structure made with molybdenum and aluminum. The detection subsystem is mounted on the optomechanical subsystem structure - a warm electronic subsystem (280K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data This presentation describes the architecture of the instrument at the end of the phase C (Detailed Design Review), the expected performance, the technological key challenges and preliminary test results obtained for different NISP subsystem breadboards and for the NISP Structural and Thermal model (STM).

Maciaszek, Thierry↗

Genesis Solar Wind Sample Curation Facility

The controlled access facility designed and constructed for storing and examining Genesis solar wind samples consists of two adjacent laboratories, both ISO Class 4 cleanrooms (vertical laminar flow, ULPA filtered). One cleanroom is equipped with ultrapure water (UPW) for experimental cleaning of containers and tools used in handling the solar wind samples, flight hardware and witness plates. The ultrapure water is also used for cleaning the solar wind samples. The other cleanroom is for long-term nitrogen storage of samples and for examination and processing of Genesis samples.

Curation Facility↗

On optimal filtering of GPS dual frequency observations without using orbit information

The concept of optimal filtering of observations collected with a dual frequency GPS P-code receiver is investigated in comparison to an approach for C/A-code units. The filter presented here uses only data gathered between one receiver and one satellite. The estimated state vector consists of a one-way pseudorange, ionospheric influence, and ambiguity biases. Neither orbit information nor station information is required. The independently estimated biases are used to form double differences where, in case of a P-code receiver, the wide lane integer ambiguities are usually recovered successfully except when elevation angles are very small. An elevation dependent uncertainty for pseudorange measurements was discovered for different receiver types. An exponential model for the pseudorange uncertainty was used with success in the filter gain computations.

Eueler, Hans-Juergen↗

EFFECT OF FILTER TEMPERATURE ON TRAPPING ZINC VAPOR

To address the {sup 65}Zn contamination issue in the TEF, a multi-task experimental program was initiated. The first experimental task was completed and is reported in Ref. 1. The results of the second experimental task are reported here. This task examined the effect of filter temperature on trapping efficiency and deposit morphology. Based on the first experimental tasks that examined filter pore size and trapping efficiency, stainless steel filter media with a 20 {micro}m pore size was selected. A series of experiments using these filters was conducted during this second task to determine the effect of filter temperature on zinc vapor trapping efficiency, adhesion and morphology. The tests were conducted with the filters heated to 60, 120, and 200 C; the zinc source material was heated to 400 C for all the experiments to provide a consistent zinc source. The samples were evaluated for mass change, deposit adhesion and morphology. As expected from the physical vapor deposition literature, a difference in deposit morphology and appearance was observed between the three filter temperatures. The filter held at 60 C had the largest average mass gain while the 120 and 200 C filters exhibited similar but lower weight gains. The standard deviations were large and suggest that all three temperatures exhibited comparable gains. No zinc was detected on the backside surface of the filters indicating high efficiency for front and internal trapping. A zinc rich deposit was formed on the surface of the 60 C filter. Based on a simple tape adhesion test, the surface zinc was readily removed from the 60 C filter while less zinc deposit was removed from the 120 and 200 C filter samples. It is surmised that the higher temperatures enable the zinc to deposit within the filter media rather than on the surface. Based on the findings that all three statistically trapped the same quantity of zinc vapor and that the higher temperatures resulted in a more adherent/better trapped product, operating the filters at 120 to 200 C is recommended.

36 MATERIALS SCIENCE↗

Charging Experiments and Filtration Testing on Facemask Materials: Towards Goals of Full Performance Restoration of Used N95 Masks and Enhancement of Common-Fabric Facemasks

Different techniques have been developed for sanitizing N95 masks while retaining whatever charge remains on them. However, these sanitizing methods do not address the fact that the electrical charge, filtration efficacy, and breathability of such masks may be expected to degrade during long-term use based on mechanisms known in the literature. In this study, approaches to electrically (re)charging facemask filter materials were explored in response to the COVID-19 induced shortage of N95 masks. The effort consisted of charging experiments followed by filtration testing conducted at the coupon level during a month-long period (May 2020). The main focus of the work was to develop a recharging technique which could eventually be adapted and used as part of a broader full-performance restoration process for used N95 masks, e.g., which might employ simple washing by alcohol or soapy water as a preceding step for sanitization and declogging. Most tested coupons were therefore nonwoven meltblown fibrous polypropylene (PP) filter media extracted from decades old N95 masks. Keeping in mind commonly used cloth facemasks, limited trials were also performed with some commercially available fabrics. Charging was done at elevated temperature and was followed by cooling to freeze in the applied charges produced from corona discharges using different electrode configurations and parameter combinations, or from triboelectric rubbing. Charging was also focused on using potentially scalable equipment, e.g., Van de Graaff generators or consumer ionic hair products. Some degree of success was achieved with one of the fabrics and the PP filter media which was first purposefully discharged to have typical filtration efficiency (FE) of ~35%. Numerous attempts at corona charging discharged media resulted in filtration efficiency (FE) ≥ 80 – 85%. Some measure of charge robustness was also established via stable performance during loading testing. However, results where FE ≥ 90% were not reliably repeatable and no results met the FE ≥ 95% goal due to shortcomings of the charging process. The best three trials for PP media statistically met the FE ≥ 90% criteria, amounted to a small percentage of the trials relying on an ionic hair dryer, and are attributed to good embedding of charges via aerodynamic force. Triboelectric charging significantly enhanced the viability of one of the polyester fabrics –measured FE increased from 19% up to 46% while maintaining a reasonably low pressure drop.

N95↗

A Bloom Filter Based Scalable Data Integrity Check Tool for Large-Scale Dataset

Large scale HPC applications are becoming increasingly data intensive. At Oak Ridge Leadership Computing Facility (OLCF), we are observing the number of files curated under individual project are reaching as high as 200 millions and project data size is exceeding petabytes. These simulation datasets, once validated, often needs to be transferred to archival system for long term storage or shared with the rest of the research community. Ensuring the data integrity of the full dataset at this scale is paramount important but also a daunting task. This is especially true considering that most conventional tools are serial and file-based, unwieldy to use and/or can't scale to meet user's demand.To tackle this particular challenge, this paper presents the design, implementation and evaluation of a scalable parallel checksumming tool, fsum, which we developed at OLCF. It is built upon the principle of parallel tree walk and work-stealing pattern to maximize parallelism and is capable of generating a single, consistent signature for the entire dataset at extreme scale. We also applied a novel bloom-filter based technique in aggregating signatures to overcome the signature ordering requirement. Given the probabilistic nature of bloom filter, we provided a detailed error and trade-off analysis. Using multiple datasets from production environment, we demonstrated that our tool can efficiently handle both very large files as well as many small-file based datasets. Our preliminary test showed that on the same hardware, it outperforms conventional tool by as much as 4×. It also exhibited near-linear scaling properties when provisioned with more compute resources.

97 MATHEMATICS AND COMPUTING↗