Search NASA⌕ Search

SEARCH · Search NASA

Results for “data reduction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

SU-F-T-12: Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy

Purpose: The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. Methods: The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The XCOM photon cross-section library was used. Variance reduction techniques were used to speed up the calculation and to considerably reduce the computer time. To obtain the dose rate distributions of the source in an unbounded liquid water phantom, the source was immersed at the center of a cube phantom of 100 cm3. Results: The obtained dose rate constant for the BEBIG 60Co source was 1.108±0.001 cGyh-1U-1, which is consistent with the values in the literature. The radial dose functions were compared with the values of the consensus data set in the literature, and they are consistent with the published data for this energy range. Conclusion: The dose rate constant is consistent with the results of Granero et al. and Selvam and Bhola within 1%. Dose rate data are compared to GEANT4 and DORZnrc Monte Carlo code. However, the radial dose function is different by up to 10% for the points that are notably near the source on the transversal axis because of the high-energy photons from 60Co, which causes an electronic disequilibrium at the interface between the source capsule and the liquid water for distances up to 1 cm.

60 APPLIED LIFE SCIENCES↗

Automated Vehicle Detection in a Nuclear Facility Using Low-Frequency Acoustic Sensors

This article presents an analysis of the method of construction and results for a classifier intended to identify vehicles using low-frequency acoustic data collected by a dis-tributed sensor network. This data is collected as part of a venture intended to explore data analytics and multisensor fusion techniques for the monitoring of activities at a test bed nuclear facility located at Oak Ridge National Laboratory in Oak Ridge, Tennessee. We describe the associated target signature and design a classifier based on a multilayer perceptron, followed by an analysis of its results. We discuss how overall accuracy is not the only consideration in constructing this classifier, and how for this application, it is actually desirable to operate at a lower level of accuracy in exchange for a reduction in the false alarm rate, as well as how this relates to the actual deployment of the classifier in practical use.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Accelerating Markov Chain Monte Carlo sampling with diffusion models

Global fits of physics models require efficient methods for exploring high-dimensional and/or multimodal posterior functions. We introduce a novel method for accelerating Markov Chain Monte Carlo (MCMC) sampling by pairing a Metropolis-Hastings algorithm with a diffusion model that can draw global samples with the aim of approximating the posterior. We briefly review diffusion models in the context of image synthesis before providing a streamlined diffusion model tailored towards low-dimensional data arrays. We then present our adapted Metropolis-Hastings algorithm which combines local proposals with global proposals taken from a diffusion model that is regularly trained on the samples produced during the MCMC run. Our approach leads to a significant reduction in the number of likelihood evaluations required to obtain an accurate representation of the Bayesian posterior across several analytic functions, as well as for a physical example based on a global fit of parton distribution functions. Our method is extensible to other MCMC techniques, and we briefly compare our method to similar approaches based on normalising flows. A code implementation can be found at https://github.com/NickHunt-Smith/MCMC-diffusion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Dynamic Reduction Network for Point Clouds

Classifying whole images is a classic problem in machine learning, and graph neural networks are a powerful methodology to learn highly irregular geometries. It is often the case that certain parts of a point cloud are more important than others when determining overall classification. On graph structures this started by pooling information at the end of convolutional filters, and has evolved to a variety of staged pooling techniques on static graphs. In this paper, a dynamic graph formulation of pooling is introduced that removes the need for predetermined graph structure. It achieves this by dynamically learning the most important relationships between data via an intermediate clustering. The network architecture yields interesting results considering representation size and efficiency. It also adapts easily to a large number of tasks from image classification to energy regression in high energy particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-G-206-15: Effects of Dose Reduction On Emphysema Score

Purpose: The purpose of this study was to investigate the effects of reducing radiation dose levels on emphysema scores from lung cancer screening CT exams. Methods: 52 cases were selected from the National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data. All scans were acquired with fixed effective mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare) using 120kV, 64×0.6mm collimation and pitch 1.0. All images were reconstructed with 1mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions at 50% and 25% of the original dose (approximately 1.0- and 0.5-mGy CTDIvol). Lung segmentations were obtained via region growing from manual seed point at a threshold of 600HU followed by manual removal of trachea and major airways. Lung segmentations were only performed on original dose scans, and mapped to simulated reduced-dose scans. Emphysema scores based on relative area of lung with attenuation values lower than −950HU (RA950) were computed for all cases. Results: Average RA950 of all 50 cases were 31.6 (±5.5), 32.5 (±4.9) and 32.8 (±4.6) for 100%, 50% and 25% dose level respectively. The average absolute difference in RA950 between simulated and original dose scans were 1.0 (±0.7) and 1.4 (±1.1) for 50% and 25% dose level respectively. Conclusion: RA950 is relatively robust to dose level, with a difference of no more than 5 from the original dose scans. The average RA950 of this population was high for a two reasons: This was a high risk population of patients with substantial smoking history; The use of B50 kernel, which may be biased towards high emphysema scores. Further exploration with smoother kernels will be conducted in the future. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH grant support from U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Statistical learning for predicting density–matrix-based electron dynamics

In this study, we consider the problem of learning density-dependent molecular Hamiltonian matrices from time series of electron density matrices, all in the context of Hartree–Fock theory. Prior work developed a solution to this problem for small molecular systems with density and Hamiltonian matrices of size at most 6 × 6. Here, using a battery of techniques, we scale prior methods to larger molecular systems with, for example, 29 × 29 matrices. This includes systems that either have more electrons or are expressed in large basis sets such as 6-311++G**. Scaling the method to larger systems enhances its relevance for realistic applications in chemistry and physics. To achieve this scaling, we apply dimensionality reduction, ridge regression and analytic computation of Hessians. Through the combination of these techniques, we are able to learn Hamiltonians by minimizing an objective function that encodes local propagation error. Importantly, these learned Hamiltonians can then be used to predict electron dynamics for thousands of steps: When we use our learned Hamiltonians to numerically solve the time-dependent Hartree–Fock equation, we obtain predicted dynamics that are in close quantitative agreement with ground truth dynamics. This includes field-off trajectories similar to the training data and field-on trajectories outside of the training data.

59 BASIC BIOLOGICAL SCIENCES↗

Radical Treatment of Haloacetonitriles in Aqueous Systems: A Kinetic Study

Haloacetonitriles (HANs) are important drinking water disinfection byproducts formed through the chlorination and chloramination of amino acids. Although HAN concentrations in treated water are usually lower than trihalomethanes, they are still of major concern due to their higher cyto- and genotoxicity. HANs undergo chemical transformations by hydrolysis on the hour to week time scales; however, for possible direct water reuse situations, their active removal using advanced oxidation/reduction processes (AO/RPs) may be required. We report here our systematic kinetic study of the four major AO/RP radiolysis species, oxidizing hydroxyl (·OH) and sulfate (SO 4 −· ) radicals and reducing hydrated electron (e aq − ) and hydrogen atoms (H · ) with five HANs (mono-, di-, and trichloroacetonitriles and mono- and dibromoacetonitriles) in water measured using electron pulse radiolysis techniques. At ambient temperatures and pH 1−7, significant reactivity was found for e aq − ( k = (1−5) × 10 10 M −1 s −1 ) and H · atoms ( k = (1 − 40 × 10 7 M −1 s −1 ), but only minimal oxidation by ·OH ( k = (0.6−10) × 10 7 M −1 s −1 ) and SO 4 −· ( k = (0.2−4) × 10 6 M −1 s −1 ) occurred. These data suggest that the large-scale AO/RP treatment of these contaminants will be effective for deaerated reducing systems, where the reductive electron-induced degradation of HANs will occur.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal conductivity evaluation of ion irradiated Si 3 N 4 and ZrN ceramics using spatial domain thermoreflectance

Nitride ceramics have been investigated for different applications in the nuclear industry, such as space nuclear power, fusion reactor diagnostics and plasma heating, inert matrix fuels, and accident tolerant fuels. Although thermal conductivity remains one of the most important properties to track following irradiation, traditional techniques such as laser flash and xenon flash are limited to bulk sample characterization, which requires lengthy and cost-consuming neutron irradiation. This work used spatial domain thermoreflectance (SDTR) for the micrometer-scale measurement of thermal conductivity in 15 MeV Ni ion-irradiated silicon nitride and zirconium nitride from 1 to 50 dpa and 300 to 700 °C. Here, the SDTR-measured unirradiated thermal conductivity was found to be consistent with the published data on bulk samples. Electrically conductive ZrN exhibits modest reduction after irradiation which is minimal at the highest irradiation temperatures. In electrically insulating Si 3 N 4 , the reduction is more significant and unlike ZrN, the reduction remains significant even at a higher irradiation temperature. The thermal resistance evolution following irradiation was compared with lattice swelling, which was determined using grazing incidence x-ray diffraction, and radiation-induced defects were observed using transmission electron microscopy. A saturation value was observed between 15 and 50 dpa for thermal conductivity degradation in both nitride ceramics and a direct correlation with high-temperature defect recombination was observed, as well as the potential presence of additional carrier scattering mechanisms.

36 MATERIALS SCIENCE↗

Metagenomic Methods for Addressing NASA's Planetary Protection Policy Requirements on Future Missions: A Workshop Report

Molecular biology methods and technologies have advanced substantially over the past decade. These new molecular methods should be incorporated among the standard tools of planetary protection (PP) and could be validated for incorporation by 2026. To address the feasibility of applying modern molecular techniques to such an application, NASA conducted a technology workshop with private industry partners, academics, and government agency stakeholders, along with NASA staff and contractors. The technical discussions and presentations of the Multi-Mission Metagenomics Technology Development Workshop focused on modernizing and supplementing the current PP assays. The goals of the workshop were to assess the state of metagenomics and other advanced molecular techniques in the context of providing a validated framework to supplement the bacterial endospore-based NASA Standard Assay and to identify knowledge and technology gaps. In particular, workshop participants were tasked with discussing metagenomics as a stand-alone technology to provide rapid and comprehensive analysis of total nucleic acids and viable microorganisms on spacecraft surfaces, thereby allowing for the development of tailored and cost-effective microbial reduction plans for each hardware item on a spacecraft. Workshop participants recommended metagenomics approaches as the only data source that can adequately feed into quantitative microbial risk assessment models for evaluating the risk of forward (exploring extraterrestrial planet) and back (Earth harmful biological) contamination. Participants were unanimous that a metagenomics workflow, in tandem with rapid targeted quantitative (digital) PCR, represents a revolutionary advance over existing methods for the assessment of microbial bioburden on spacecraft surfaces. The workshop highlighted low biomass sampling, reagent contamination, and inconsistent bioinformatics data analysis as key areas for technology development. Finally, it was concluded that implementing metagenomics as an additional workflow for addressing concerns of NASA's robotic mission will represent a dramatic improvement in technology advancement for PP and will benefit future missions where mission success is affected by backward and forward contamination.

59 BASIC BIOLOGICAL SCIENCES↗

Data-driven approach to parameterize SCAN + U for an accurate description of 3 d transition metal oxide thermochemistry

Semilocal density-functional theory (DFT) methods exhibit significant errors for the phase diagrams of transition-metal oxides that are caused by an incorrect description of molecular oxygen and the large self-interaction error in materials with strongly localized electronic orbitals. Empirical and semiempirical corrections based on the DFT + U method can reduce these errors, but the parameterization and validation of the correction terms remains an on-going challenge. Here we develop a systematic methodology to determine the parameters and to statistically assess the results by considering interlinked thermochemical data across a set of transition metal compounds. We consider three interconnected levels of correction terms: (1) a constant oxygen binding correction, (2) Hubbard-U correction, and (3) DFT/DFT + U compatibility correction. The parameterization is expressed as a unified optimization problem. We demonstrate this approach for 3d transition metal oxides, considering a target set of binary and ternary oxides. With a total of 37 measured formation enthalpies taken from the literature, the dataset is augmented by the reaction energies of 1710 unique reactions that were derived from the formation energies by systematic enumeration. To ensure a balanced dataset across the available data, the reactions were grouped by their similarity using clustering and suitably weighted. The parameterization is validated using leave-one-out cross validation (CV), a standard technique for the validation of statistical models. We apply the methodology to the strongly constrained and appropriately normed (SCAN) density functional. Based on the CV score, the error of binary (ternary) oxide formation energies is reduced by 40% (75%) to 0.10 (0.03) eV/atom. A simplified correction scheme that does not involve SCAN/SCAN + U compatibility terms still achieves an error reduction of 30% (25%). The method and tools demonstrated here can be applied to other classes of materials or to parameterize the corrections to optimize DFT + U performance for other target physical properties.

36 MATERIALS SCIENCE↗

Unraveling the Active Site in Copper-ceria Systems for the Water Gas Shift Reaction: In-situ Characterization of an Inverse Powder CeO2-x/CuO-Cu Catalyst

An inverse powder system composed of CeO{sub 2} nanoparticles dispersed over a CuO-Cu matrix is proposed as a novel catalyst for the water-gas shift reaction. This inverse CeO{sub 2}/CuO-Cu catalyst exhibits a higher activity than standard Cu/CeO{sub 2} catalysts. In situ synchrotron characterization techniques were employed to follow the structural changes of CeO{sub 2}/CuO-Cu under reaction conditions. Time-resolved X-ray diffraction experiments showed the transformation of CuO to metallic Cu via a Cu{sub 2}O intermediate. Short-order structural changes were followed by pair distribution function analysis and corroborated the results obtained by diffraction. Moreover, X-ray absorption spectroscopy also revealed oxidation state changes from Cu{sup 2+} to Cu{sup 0} and the partial reduction of CeOx nanoparticles. The activity data obtained by mass spectrometry revealed that hydrogen production starts once the copper has been fully reduced. The strong interaction of ceria and copper boosted the catalytic performance of the sample. The inverse catalyst was active at low temperatures, stable to several reaction runs and to redox cycles. These characteristics are highly valuable for mobile fuel cell applications. The active phases of the inverse CeO{sub 2}/CuO-Cu catalyst are partially reduced ceria nanoparticles strongly interacting with metallic copper. The nature and structure of the ceria nanoparticles are of critical importance because they are involved in processes related to water dissociation over the catalyst surface.

08 HYDROGEN↗

Evaluation of Changes to the MTR Fuel Dissolution Flowsheet to Increase the Number of L-Bundles Charged to a Dissolver

Material Test Reactor (MTR) fuels are dissolved in the H-Canyon facility using a Hg-catalyzed, HNO₃ dissolution flowsheet. The flowsheet is based on experimental work in which laboratory-scale experiments were used to provide bounding values for both offgas and H₂ generation rates. The generation of H₂ gas, primarily from the dissolution of Al, is controlled by limiting the surface area exposed to the solution. The number of L-Bundles charged and their submergence level defines the exposed surface area which is directly proportional to the H₂ generation rate. For the MTR fuel dissolution flowsheet, the maximum number of L-Bundles which can be charged to a dissolver was specified as a function of the Al concentration in the solution and the submergence level of the bundle. The MTR fuels are currently dissolved in the 6.1D dissolver. To reach the desired terminal Al concentration, a total of 12 L-Bundles of fuel are dissolved per batch. Depending on the submergence level being used in the dissolver, the 12 bundles are dissolved in three charges of four bundles per charge or in a sequence of three, four, and five bundles. However, if six L-Bundles could be dissolved in the initial charge, a dissolver batch could be completed in two dissolutions instead of three. To assess the feasibility of dissolving six bundles in the first charge, the Savannah River National Laboratory evaluated changes to the MTR flowsheet which increase the number of bundles which can be charged to a dissolver. Since the development of the existing MTR fuel dissolution flowsheet, improved offgas measurement methods have been developed to more accurately calculate the offgas composition and generation rate during laboratory-scale dissolutions. In the first part of this study, improvements in the calibration model for the Raman spectrometer (used for offgas characterization) and a more effective data smoothing routine were applied to existing data. The uncertainty in the offgas composition data used to define the MTR fuel dissolution flowsheet were subsequently re-evaluated which resulted in an approximate 50% reduction in the uncertainty of the H₂ gas concentration measurements. The reduced uncertainty was used in new calculations to define the maximum number of L-Bundles which can be charged to either the 6.1D or 6.4D dissolver as a function of the Al concentration. With the reduced uncertainty in the H₂ concentration measurements, a flowsheet was defined which supported initially charging 6 bundles to a dissolver. This flowsheet is based on the use of 0.002 M Hg, an L-Bundle immersion depth of 54 in., an air sparge/purge flowrate of 40 scfm, an iodine reactor operating temperature of 200 °C, and not exceeding 60% of the H₂ LFL in the dissolver offgas. In the second phase of this study, calculations were performed to assess the impact of changing various operating parameters to increase the number of L-Bundles charged to an H-Canyon dissolver. Applying the improved offgas measurement techniques including the reduced uncertainty in the H₂ concentration measurements to the existing data, the number of bundles of MTR fuel which can be charged to either the 6.1D or 6.4D dissolver were calculated based on varying the bundle immersion depth (44-60 in.), air sparge/purge flowrate (40-60 scfm), iodine reactor operating temperature (150-200 °C), and the percentage of the H₂ LFL which must not be exceeded (60-76%). Qualitatively, the percentage of the LFL had the largest influence on the maximum number of bundles which can be charged to a dissolver followed by the air sparge/purge flowrate, L-Bundle immersion depth, and the iodine reactor operating temperature. During the evaluation of each variable, the other variables were held at the baseline flowsheet conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synchrotron-based techniques for characterizing STCH water-splitting materials

Understanding the role of oxygen vacancy–induced atomic and electronic structural changes to complex metal oxides during water-splitting processes is paramount to advancing the field of solar thermochemical hydrogen production (STCH). The formulation and confirmation of a mechanism for these types of chemical reactions necessitate a multifaceted experimental approach, featuring advanced structural characterization methods. Synchrotron X-ray techniques are essential to the rapidly advancing field of STCH in part due to properties such as high brilliance, high coherence, and variable energy that provide sensitivity, resolution, and rapid data acquisition times required for the characterization of complex metal oxides during water-splitting cycles. X-ray diffraction (XRD) is commonly used for determining the structures and phase purity of new materials synthesized by solid-state techniques and monitoring the structural integrity of oxides during water-splitting processes (e.g., oxygen vacancy–induced lattice expansion). X-ray absorption spectroscopy (XAS) is an element-specific technique and is sensitive to local atomic and electronic changes encountered around metal coordination centers during redox. While in operando measurements are desirable, the experimental conditions required for such measurements (high temperatures, controlled oxygen partial pressures, and H 2 O) practically necessitate in situ measurements that do not meet all operating conditions or ex situ measurements. Here, we highlight the application of synchrotron X-ray scattering and spectroscopic techniques using both in situ and ex situ measurements, emphasizing the advantages and limitations of each method as they relate to water-splitting processes. The best practices are discussed for preparing quenched states of reduction and performing synchrotron measurements, which focus on XRD and XAS at soft (e.g., oxygen K-edge, transition metal L-edges, and lanthanide M-edges) and hard (e.g., transition metal K-edges and lanthanide L-edges) X-ray energies. The X-ray absorption spectra of these complex oxides are a convolution of multiple contributions with accurate interpretation being contingent on computational methods. The state-of-the-art methods are discussed that enable peak positions and intensities to be related to material electronic and structural properties. Through careful experimental design, these studies can elucidate complex structure–property relationships as they pertain to nonstoichiometric water splitting. A survey of modern approaches for the evaluation of water-splitting materials at synchrotron sources under various experimental conditions is provided, and available software for data analysis is discussed.

08 HYDROGEN↗

Integrated Pest Management (IPM) for Early Detection Algal Crop Protection. Final Report

During large-scale, outdoor algal biomass growth, production strain(s) are subject to attack by pathogens, predators, and non-productive competitors, compromising the biomass yield. The project team at UCSD developed and demonstrated the effectiveness of Volatile Organic Compound, VOC, analysis via mass spectrometry (MS) as an early detection system for the presence of production algal ponds infection. The MS detection can then trigger high-resolution melt analysis (HRMA) and enhanced quantitative PCR (qPCR) to identify predatory or pathogenic species precisely. This study gathered the foundational data informing how wholly automated systems monitor the health of production ponds. By detecting the presence of low molecular weight VOCs in the air space above ponds, the instrument was able to mimic “sniffing” the health of the algae pond. This early warning system will be free growers from time-consuming and costly regular surveillance of ponds with the current techniques, such as qPCR and flow-cam assays, which are slower, less sensitive, and not easily fully automated, resulting in increased production efficiency through the reduction of crop loss. This project demonstrated that Chemical Ionization Mass Spectrometry, CIMS, could serve as a real-time monitor of ponds health tracking up to 100 different VOCs simultaneously for continuous periods up to 60 days without interruption, signaling infection within an algal crop 24 to 36 hours prior to techniques such as qPCR and microscopy. While mass spectrometry is an expensive tool, this simple VOC sampling system proved not only to be sensitive and robust but could to multiplexed to monitor several ponds, lowering the overall cost serially. This technology demonstrated a reduction in biomass production cost by approximately 50% compared to growers not employing any detection methodology.

09 BIOMASS FUELS↗

Analog neutron transport for nuclear instrumentation applications with the Monte-Carlo code TRIPOLI-4 - Paper 3

Monte-Carlo codes simulating particle transport usually make use of well-known variance reduction techniques, leading to more efficient simulations. Even in configurations which do not deal with deep-penetration, some of these techniques, such as the implicit capture, are actually often used by default. The statistical weight of the simulated particles is then modified in order to take into account the modification of the sampling without introducing any bias in the estimation process. For instance, the implicit capture decreases the statistical weight of the particles at each collision, whereas the sampling of a single outgoing particle increases this statistical weight in case of scattering reactions producing multiple neutrons. In addition, Russian roulette and splitting operations, which are usually also played at each collision, lead to other modifications of the statistical weights. As a result, Monte-Carlo codes provide particle histories that are valid on average, but collect statistical weights which differ from 1, when tallying the estimation of the quantities of interest. Yet, some nuclear instrumentation calculations inherently need to work with statistical weights equal to 1, since either individual events have to be collected (such as the arrival of a particle at a detector, the measurement of a time of flight, etc), or the coincidence of events or also correlations between individual events have to be taken into account. To address these specific applications with Monte-Carlo simulation codes, users need a full analog simulation mode. The continuous-energy Monte-Carlo code TRIPOLI4{sup R} is mainly dedicated to shielding, reactor physics and criticality safety calculations. Its capabilities have recently been extended to widen its use to nuclear instrumentation with the possibility of γ-spectrometry calculations and the simulation of photonuclear reactions for instance. Other features needed by nuclear instrumentation applications have been available in TRIPOLI-4 for a long time, such as the sampling of the time variable and the possibility of tallying in a time grid for most of the available tallies (fluxes, reaction rates, dose equivalent rates, energy depositions, etc). In TRIPOLI-4, the transport between two consecutive collisions is analog if no variance reduction technique is requested by the user to handle deep-penetration configurations. However, up to the version 9 of the code, the collision itself is sampled in a non-analog way. This paper presents a first implementation of a full analog neutron transport mode in TRIPOLI-4, preliminary verification results and an application of this functionality to the simulation of the Nucifer detector located in Saclay, France. It should be noted that only neutron transport is dealt with in this work and that all nuclear data come from JEFF-3.1.1 or ENDF/B-VII.0 evaluations, including fission data when needed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Unraveling the Active Site in Copper-Ceria Systems for the Water-Gas Shift Reaction: In Situ Characterization of an Inverse Powder CeO2-x/CuO-Cu Catalyst

An inverse powder system composed of CeO{sub 2} nanoparticles dispersed over a CuO-Cu matrix is proposed as a novel catalyst for the water-gas shift reaction. This inverse CeO{sub 2}/CuO-Cu catalyst exhibits a higher activity than standard Cu/CeO{sub 2} catalysts. In situ synchrotron characterization techniques were employed to follow the structural changes of CeO{sub 2}/CuO-Cu under reaction conditions. Time-resolved X-ray diffraction experiments showed the transformation of CuO to metallic Cu via a Cu{sub 2}O intermediate. Short-order structural changes were followed by pair distribution function analysis and corroborated the results obtained by diffraction. Moreover, X-ray absorption spectroscopy also revealed oxidation state changes from Cu{sup 2+} to Cu{sup 0} and the partial reduction of CeO{sub x} nanoparticles. The activity data obtained by mass spectrometry revealed that hydrogen production starts once the copper has been fully reduced. The strong interaction of ceria and copper boosted the catalytic performance of the sample. The inverse catalyst was active at low temperatures, stable to several reaction runs and to redox cycles. These characteristics are highly valuable for mobile fuel cell applications. The active phases of the inverse CeO{sub 2}/CuO-Cu catalyst are partially reduced ceria nanoparticles strongly interacting with metallic copper. The nature and structure of the ceria nanoparticles are of critical importance because they are involved in processes related to water dissociation over the catalyst surface.

08 HYDROGEN↗

A High-Throughput Study of PtNiZr Catalysts for Application in PEM Fuel Cells

The effects of adding Zr to PtNi oxygen reduction reaction (ORR) electrocatalyst alloys were examined in a study aimed at probing the possibility of creating catalysts with enhanced resistance to corrosion in a PEM fuel cell environment. Samples consisting of pure Pt or PtNiZr alloys with a range of compositions (not exceeding 11 at.% Zr) were fabricated using co-sputter deposition. A high-throughput fabrication approach was used wherein 18 distinct thin film catalyst alloy samples with varying compositions were deposited onto a large-area substrate with individual Au current collector structures. A multi-channel pseudo-potentiostat allowed for the simultaneous quantitative study of catalytic activity for all 18 electrodes in a single test bath, a first for the study of ORR electrocatalysts. A properly stirred oxygenated 1 M H{sub 2}SO{sub 4} electrolyte solution was used to provide each electrode with a steady-state flow of reactants during electrochemical evaluation. The onset potentials, absolute current density values, and Tafel analysis data obtained using this technique were compared with literature reports. The analyses showed that most PtNiZr alloys tested offered improvements over pure Pt, however those surfaces with a high mole fraction (>4 at.%) of Zr exhibited reduced activity that was roughly inversely correlated to the amount of Zr present. Film composition, morphology, and crystallographic properties were examined using X-ray energy dispersive spectroscopy (XEDS), X-ray photoelectron spectroscopy (XPS), SEM, and synchrotron X-ray diffraction. These data were then correlated with electrochemical data to elucidate the relationships between composition, structure, and relative performance for this ternary system.

30 DIRECT ENERGY CONVERSION↗

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross-validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. Conclusions: The topological soft-gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗