Search NASA⌕ Search

SEARCH · Search NASA

Results for “data usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Orbiter electrical equipment utilization baseline

The baseline for utilization of Orbiter electrical equipment in both electrical and Environmental Control and Life Support System (ECLSS) thermal analyses is established. It is a composite catalog of Space Shuttle equipment, as defined in the Shuttle Operational Data Book. The major functions and expected usage of each component type are described. Functional descriptions are designed to provide a fundamental understanding of the Orbiter electrical equipment, to insure correlation of equipment usage within nominal analyses, and to aid analysts in the formulation of off-nominal, contingency analyses.

Source record↗

Solar-Radiation Measuring Equipment and Glossary

1976 listing of commercially available solar-radiation measuring equipment is presented in 50-page report. Sensor type, response time, cost data, and comments concerning specifications and intended usage are listed for 145 instruments from 38 manufactures.

Carter, E. A.↗

CRAYCDC

The CRAYCDC is a FORTRAN subroutine which runs on the CDC Cyber 205. It converts 64 bit binary data from a Cray computer (1S or X-MP) to the corresponding 64 bit binary data for a Cyber 205. The purpose, usage, storage, timing consideration, access to CRAYCDC, are outlined.

Guest, C. J.↗

On satellite scatterometer capabilities in air-sea interaction

The verified capabilities and some practical usage of the satellite scatterometer in geophysical data production have demonstrated the value of this instrument. This evaluation of scatterometer ability to measure marine winds includes the scatterometer verification data, the state of the art planetary boundary layer model relating the wind profile in the atmosphere to the surface stress, and the pertinent results of the Storms Response Experiment.

Brown, R. A.↗

Shuttle orbit flight control design lessons - Direction for Space Station

The Space Shuttle orbit flight control system, which operates during all exo-atmospheric flight phases, has successfully met operational requirements. Many design integration and operational issues that required resolution during development and testing provide an experience base that will benefit the development of future space systems, particularly the Space Station. To this end, the applicable Shuttle and Space Station hardware/software is reviewed with some perspective provided on how current design groundrules were derived and how issues that affected the Shuttle orbit control system design are a pathway for the Space Station. Some of the most significant lessons learned from the Shuttle are summarized, with a discussion of the effect of performance and design of hardware, including the data processing system on software structures and usage procedures. Crew interface issues and important results from man-in-the-loop tests are summarized. Problems resulting from trying to meet difficult orbital operational objectives, including some sophisticated payload operations are characterized. Several proposed Shuttle flight control design improvements, developed in response to some of the lessons learned so far, are identified. Potential application of the Shuttle design lessons and new control technologies to the Space Station are discussed.

Cox, Kenneth J.↗

Network issues for large mass storage requirements

File Servers and Supercomputing environments need high performance networks to balance the I/O requirements seen in today's demanding computing scenarios. UltraNet is one solution which permits both high aggregate transfer rates and high task-to-task transfer rates as demonstrated in actual tests. UltraNet provides this capability as both a Server-to-Server and Server-to-Client access network giving the supercomputing center the following advantages highest performance Transport Level connections (to 40 MBytes/sec effective rates); matches the throughput of the emerging high performance disk technologies, such as RAID, parallel head transfer devices and software striping; supports standard network and file system applications using SOCKET's based application program interface such as FTP, rcp, rdump, etc.; supports access to the Network File System (NFS) and LARGE aggregate bandwidth for large NFS usage; provides access to a distributed, hierarchical data server capability using DISCOS UniTree product; supports file server solutions available from multiple vendors, including Cray, Convex, Alliant, FPS, IBM, and others.

Perdue, James↗

Small-RPS Enabled Mars Rover Concept

Both the MER and the Mars Pathfinder rovers operated on Mars in an energy-limited mode, since the solar panels generated power during daylight hours only. At other times the rovers relied on power stored in batteries. In comparison, Radioisotope Power Systems (RPS) offer a power-enabled paradigm, where power can be generated for long mission durations (measured in years), independently from the Sun, and on a continuous basis. A study was performed at PL to assess the feasibility of a small-RPS enabled MER-class rover concept and any associated advantages of its mission on Mars. The rover concept relied on design heritage from MER with two significant changes. First, the solar panels were replaced with two single GPHS module based small-RPSs. Second, the Mossbauer spectroscope was substituted with a laser Raman spectroscope, in order to move towards MEPAG defined astrobiology driven science goals. The highest power requirements were contributed to mobility and telecommunication type operating modes, hence influencing power system sizing. The resulting hybrid power system included two small-RPSs and two batteries. Each small-RPS was assumed to generate 50We of power or 62OWh/sol of energy (BOL), comparable to that of MER. The two 8Ah batteries were considered available during peak power usage. Mission architecture, power trades, science instruments, data, communication, thermal and radiation environments, mobility, mass issues were also addressed. The study demonstrated that a new set of RPS-enabled rover missions could be envisioned for Mars exploration within the next decade, targeting astrobiology oriented science objectives, while powered by 2 to 4 GPHS modules.

Mars exploration↗

Fatigue Crack Growth in Peened Friction Stir Welds

Friction stir welding induces residual stresses that accelerates fatigue crack growth in the weld nugget. Shot peening over the weld had little effect on growth rate. Laser peening over the weld retarded the growth rate: Final crack growth rate was comparable to the base, un-welded material. Crack tunneling evident from residual compressive stresses. 2195-T8 fracture surfaces were highly textured. Texturing makes comparisons difficult as the material system is affecting the data as much as the processing. Material usage becoming more common in space applications requiring additional work to develop useful datasets for damage tolerance analyses.

Forth, Scott C.↗

Energy Management Operations for the InSight Solar-Powered Mission at Mars

This paper discusses how the change in launch date has changed the energy management challenges for InSight, and how the energy management approach for surface operations has been adapted to address those challenges. It also describes how energy balance and battery life are protected over the course of the InSight landed mission, in terms of a deliberate balance between autonomous on-board fault protection and ground commanding into reduced-load configurations that still make progress versus specific, prioritized mission success criteria. It describes the project’s unique statistical analysis and usage of Mars Exploration Rovers (MER) archived data on solar energy collection to develop and validate an explicit prelaunch margin policy versus energy reductions due to environment variability over multiple-sol sequences. And finally, the paper explains how this archived energy data has influenced the modification of the Phoenix-heritage autonomous fault protection, to guard against quickly-arising inclement power-generation conditions, such as rapid onset of a local dust storm or water ice cloud front.

Lisano II, MIchael E.↗

Do Heat Pump Clothes Dryers Make Sense for the U.S. Market

Heat pump clothes dryers (HPCDs) can be as much as 50percent more energy-efficient than conventional electric resistance clothes dryers, and therefore have the potential to save substantial amounts of electricity. While not currently available in the U.S., there are manufacturers in Europe and Japan that produce units for those markets. Drawing on analysis conducted for the U.S. Department of Energy's (DOE) current rulemaking on amended standards for clothes dryers, this paper evaluates the cost-effectiveness of HPCDs in American homes, as well as the national impact analysis for different market share scenarios. In order to get an accurate measurement of real energy savings potential, the paper offers a new energy use calculation methodology that takes into account the most current data on clothes washer cycles, clothes dryer usage frequency, remaining moisture content, and load weight per cycle, which is very different from current test procedure values. Using the above methodology along with product cost estimates developed by DOE, the paper presents the results of a life-cycle cost analysis of the adoption of HPCDs in a representative sample of American homes. The results show that HPCDs have positive economic benefits only for households with high clothes dryer usage or for households with high electricity prices and moderately high utilization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Active Climate Control Seats on Energy Use, Fuel Use, and CO2 Emissions

A project was developed through collaboration between Gentherm and NREL to determine the impact of climate control seats for light-duty vehicles in the United States. The project used a combination of experimentation and analysis, with experimental results providing critical input to the analysis process. First, outdoor stationary vehicle testing was performed at NREL's facility in Golden, CO using multiple occupants. Two pre-production Ford Focus electric vehicles were used for testing; one containing a standard inactive seat and the second vehicle containing a Gentherm climate control seat. Multiple maximum cool-down and steady-state cooling tests were performed in late summer conditions. The two vehicles were used to determine the increase in cabin temperature when using the climate control seat in comparison to the baseline vehicle cabin temperature with a standard seat at the equivalent occupant whole-body sensation. The experiments estimated that on average, the climate control seats allowed for a 2.61 degrees Celsius increase in vehicle cabin temperature at equivalent occupant body sensation compared to the baseline vehicle. The increased cabin air temperature along with their measured energy usage were then used as inputs to the national analysis process. The national analysis process was constructed from full vehicle cabin, HVAC, and propulsion models previously developed by NREL. In addition, three representative vehicle platforms, vehicle usage patterns, and vehicle registration weighted environmental data were integrated into the analysis process. Both the baseline vehicle and the vehicle with climate control seats were simulated, using the experimentally determined cabin temperature offset of 2.61degrees Celsius and added seat energy as inputs to the climate control seat vehicle model. The U.S. composite annual fuel use savings for the climate control seats over the baseline A/C system was determined to be 5.1 gallons of gasoline per year per vehicle, corresponding to 4.0 grams of CO2/mile savings. Finally, the potential impact of 100 percent adoption of climate control seats on U.S. light-duty fleet A/C fuel use was calculated to be 1.3 billion gallons of gasoline annually with a corresponding CO2 emissions reduction of 12.7 million tons. Direct comparison of the impact of the CCS to the ventilated seat off-cycle credit was not possible because the NREL analysis calculated a combined car/truck savings and the baseline A/C CO2 emissions were higher than EPA. To enable comparison, the CCS national A/C CO2 emissions were split into car/truck components and the ventilated seat credit was scaled up. The split CO2 emissions savings due to the CCS were 3.5 g/mi for a car and 4.4 g/mi for a truck. The CCS saved an additional 2.0 g/mi and 2.5 g/mi over the adjusted ventilated seat credit for a car and truck, respectively.

30 DIRECT ENERGY CONVERSION↗

2023 Real-time Optimization Workflow Status Update

Nuclear integrated energy systems are composed of a diverse set of energy generation sources and exist in dynamic and competitive electricity markets. With the inclusion of thermal energy storage, nuclear power systems can store heat for future use through various processes, such as water desalination or hydrogen generation. This heat storage can be managed in such a way as to economically optimize its usage. By combining real-time price data from the day-ahead and real-time markets with predictive and intelligent models, the charging and discharging of the thermal energy storage may be determined and optimized. This research details an approach through models and systems for the real-time optimization (RTO) of capacity allocation. Virtual models of the energy system and its physics phenomenon and component interactions provide intelligence to verification and prediction of operations. An optimization framework can use data generated from both a set of physical assets as well as the virtual models to predict future performance and create optimization and control workflows. Data warehouse technologies can be used to combine data across models, optimization workflows, market price data, and sensor data to intuitively store various types of data and provide integrations to physical control systems as well as user visualizations. Put together, these components can create a system for the RTO of nuclear integrated energy systems. Various virtual models and bench-scale physical demonstrations have been successfully performed and verified using this system. Larger scale testbeds that include thermal energy storage systems have been identified as future opportunities. A gap analysis that details the steps necessary to reach a physical demonstration at this scale is provided, along with conclusions on the current effort and future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The CanBikeCO Full Pilot: Long-Term Results and Analysis From an E-Bike Program in Colorado, USA

Personal micromobility devices like bicycles, e-bikes, and scooters are low- or zero-energy alternatives to single-occupancy vehicles. However, a lack of data has led to a dearth of data-driven research on personally owned e-bike usage. We present longitudinal findings from the CanBikeCO program, focused on e-bike adoption and use across demographics, trip characteristics, and geographies in the state of Colorado. CanBikeCO recorded travel survey data from low-income individuals provided with personal e-bikes by the Colorado Energy Office in six communities across Colorado from July 2021 to December 2022. The data were collected using a custom instance of the National Renewable Energy Laboratory OpenPATH platform, which combines passive data collection with semantic information such as trip mode and purpose labels. To our knowledge, there are no prior travel survey data on personally owned e-bikes with this range and scope. Insights from this unique dataset include: (i) work trips were 17% more likely than average trips to be taken on an e-bike, (ii) e-bikes were most often reported to replace cars (34% of e-bike trips) and other personal micromobility devices (22%), and (iii) participants favored walking for trips less than 1 mile, e-bikes for trips of 1-3 miles, and e-bikes, cars, or shared rides for trips of 3-20 miles. The data used to generate these results have been made available in the Transportation Secure Data Center. We find e-bike use is appealing across age groups and may be related to characteristics of land use, urban form, occupation, income, and car ownership. We conclude for this population that the energy demand added by e-bike use (induced demand and replacing non-motorized modes) is outweighed by the reduction in energy demand from replacement of single-occupancy vehicle trips with e-bike trips. Our findings suggest considerable potential for energy savings from personal e-bike ownership.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Eye-Tracking Data with Regards to the Complexity of Flight Deck Information Automation and Management - Inattentional Blindness, System State Awareness, and EFB Usage

In the constant drive to further the safety and efficiency of air travel, the complexity of avionics-related systems, and the procedures for interacting with these systems, appear to be on an ever-increasing trend. While this growing complexity often yields productive results with respect to system capabilities and flight efficiency, it can place a larger burden on pilots to manage increasing amounts of information and to understand intricate system designs. Evidence supporting this observation is becoming widespread, yet has been largely anecdotal or the result of subjective analysis. One way to gain more insight into this issue is through experimentation using more objective measures or indicators. This study utilizes and analyzes eye-tracking data obtained during a high-fidelity flight simulation study wherein many of the complexities of current flight decks, as well as those planned for the next generation air transportation system (NextGen), were emulated. The following paper presents the findings of this study with a focus on electronic flight bag (EFB) usage, system state awareness (SSA) and events involving suspected inattentional blindness (IB).

Dill, Evan T.↗

ZFS Interface For Accelerators

As data volume increases in HPC centers, storing data in reasonable amounts of space and time while maintaining data integrity and recoverability becomes ever more difficult. ZFS is a filesystem that provides these features, among many others, that make it attractive for usage in HPC environments. It has the ability to compress data, compute checksums, and compute redundancy codes within the same runtime, rather than compute each separately, without knowledge of the underlying structure of the filesystem. However, measurements have shown that compression on CPUs can be incredibly inefficient and significantly reduce the performance of ZFS. The ZFS Interface for Accelerators (Z.I.A.) was developed to provide an interface to route data to accelerators while being processed by ZFS, so that the ZFS infrastructure and features are maintained, while allowing for ZFS administrators to provide faster implementations of compression, or other features, to their instance of ZFS.

Lee, Jason↗

Complete and Correct Transfer of Information (CACTI)

Many distributed systems, file transfer mechanisms, and message passing systems offer reliability mechanisms such as acknowledgements, retries, and durability. While these tools may be “good enough” for their typical use cases, they may not offer sufficient coverage for the wide range of faults that impact data transfers and communication. A gap in the reliability measures may lead to some small amount of data loss. Some high-consequence systems cannot tolerate the loss or corruption of even a single record. We present seven principles that will counter a wide range of faults and protect against data loss and corruption. These principles bring together lessons learned from a wide range of technologies and can inform appropriate system design and application usage. These principles will help readers reason on how prevent data loss in a multi-hop pipeline and how to properly use tools that may have a deficiency in reliability.

97 MATHEMATICS AND COMPUTING↗

Yahoo! Compute Coop (YCC). A Next-Generation Passive Cooling Design for Data Centers

The purpose of the Yahoo! Compute Coop (YCC) project is to research, design, build and implement a greenfield "efficient data factory" and to specifically demonstrate that the YCC concept is feasible for large facilities housing tens of thousands of heat-producing computing servers. The project scope for the Yahoo! Compute Coop technology includes: - Analyzing and implementing ways in which to drastically decrease energy consumption and waste output. - Analyzing the laws of thermodynamics and implementing naturally occurring environmental effects in order to maximize the "free-cooling" for large data center facilities. "Free cooling" is the direct usage of outside air to cool the servers vs. traditional "mechanical cooling" which is supplied by chillers or other Dx units. - Redesigning and simplifying building materials and methods. - Shortening and simplifying build-to-operate schedules while at the same time reducing initial build and operating costs. Selected for its favorable climate, the greenfield project site is located in Lockport, NY. Construction on the 9.0 MW critical load data center facility began in May 2009, with the fully operational facility deployed in September 2010. The relatively low initial build cost, compatibility with current server and network models, and the efficient use of power and water are all key features that make it a highly compatible and globally implementable design innovation for the data center industry. Yahoo! Compute Coop technology is designed to achieve 99.98% uptime availability. This integrated building design allows for free cooling 99% of the year via the building's unique shape and orientation, as well as server physical configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling

We investigate the existence of the principal-agent (PA) problem in non-government, non-mall commercial buildings in the U.S. in 2003. The analysis concentrates on space heating and cooling energy consumed by centrally installed equipment in order to verify whether a market failure caused by the PA problem might have prevented the installation of energy-efficient devices in non-owner-occupied buildings (efficiency problem) and/or the efficient operation of space-conditioning equipment in these buildings (usage problem). Commercial Buildings Energy Consumption Survey (CBECS) 2003 data for single-owner, single-tenant and multi-tenant occupied buildings were used for conducting this evaluation. These are the building subsets with the appropriate conditions for assessing both the efficiency and the usage problems. Together, these three building types represent 51.9percent of the total floor space of all buildings with space heating and 59.4percent of the total end-use energy consumption of such buildings; similarly, for space cooling, they represent 52.7percent of floor space and 51.6percent of energy consumption. Our statistical analysis shows that there is a usage PA problem. In space heating it applies only to buildings with a small floor area (<_50,000 sq. ft.). We estimate that in 2003 it accounts for additional site energy consumption of 12.3 (+ 10.5 ) TBtu (primary energy consumption of 14.6 [+- 12.4] TBtu), corresponding to 24.0percent (+- 20.5percent) of space heating and 10.2percent (+- 8.7percent) of total site energy consumed in those buildings. In space cooling, however, the analysis shows that the PA market failure affects the complete set of studied buildings. We estimate that it accounts for a higher site energy consumption of 8.3 (+-4.0) TBtu (primary energy consumption of 25.5 [+- 12.2]TBtu), which corresponds to 26.5percent (+- 12.7percent) of space cooling and 2.7percent (+- 1.3percent) of total site energy consumed in those buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗