Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

elm-diagnostics

elm-diagnostics is a Python package for computing diagnostic analyses and visualizations for the E3SM Land Model (ELM) component and is meant to support new feature development in ELM. The tool reads model history files and performs quantitative analyses including budget-closure checking, variable transformations, temporal aggregations, and statistical summaries to support model evaluation, validation, and scientific interpretation. The framework is designed for extensibility, with modular architecture enabling straightforward addition of new diagnostic methods, derived variables, analysis types, visualization approaches, and model-specific adaptations

Hoffman, Matt [Los Alamos National Laboratory]↗

Preliminary Neutronics Analysis of the ITER Toroidal Interferometer and Polarimeter Diagnostic Corner Cube Retroreflectors

ITER is an international project under construction in France that will demonstrate nuclear fusion at a power plant-relevant scale. The Toroidal Interferometer and Polarimeter (TIP) Diagnostic will be used to measure the plasma electron line density along 5 laser-beam chords. This line-averaged density measurement will be input to the ITER feedback-control system. The TIP is considered the primary diagnostic for these measurements, which are needed for basic ITER machine control. Therefore, system reliability & accuracy is a critical element in TIP’s design. There are two major challenges to the reliability of the TIP system. First is the survivability and performance of in-vessel optics and second is maintaining optical alignment over long optical paths and large vessel movements. Both of these issues greatly depend on minimizing the overall distortion due to neutron & gamma heating of the Corner Cube Retroreflectors (CCRs). These are small optical mirrors embedded in five first wall locations around the vacuum vessel, corresponding to certain plasma tangency radii. During the development of the design and location of these CCRs, several iterations of neutronics analyses were performed to determine and minimize the total distortion due to nuclear heating of the CCRs. The CCR corresponding to TIP Channel 2 was chosen for analysis as a good middle-road case, being an average distance from the plasma (of the five channels) and having moderate neutron shielding from its blanket shield housing. Results show that Channel 2 meets the requirements of the TIP Diagnostic, but barely. These results suggest other CCRs might be at risk of exceeding thermal deformation due to nuclear heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Fast Evaluation of Viral Emerging Risks (FEVER): A computational tool for biosurveillance, diagnostics, and mutation typing of emerging viral pathogens

Viral pathogens can rapidly evolve, adapt to novel hosts, and evade human immunity. The early detection of emerging viral pathogens through biosurveillance coupled with rapid and accurate diagnostics are required to mitigate global pandemics. However, RNA viruses can mutate rapidly, hampering biosurveillance and diagnostic efforts. Here, we present a novel computational approach called FEVER (Fast Evaluation of Viral Emerging Risks) to design assays that simultaneously accomplish: 1) broad-coverage biosurveillance of an entire group of viruses, 2) accurate diagnosis of an outbreak strain, and 3) mutation typing to detect variants of public health importance. We demonstrate the application of FEVER to generate assays to simultaneously 1) detect sarbecoviruses for biosurveillance; 2) diagnose infections specifically caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); and 3) perform rapid mutation typing of the D614G SARS-CoV-2 spike variant associated with increased pathogen transmissibility. These FEVER assays had a high in silico recall (predicted positive) up to 99.7% of 525,708 SARS-CoV-2 sequences analyzed and displayed sensitivities and specificities as high as 92.4% and 100% respectively when validated in 100 clinical samples. The D614G SARS-CoV-2 spike mutation PCR test was able to identify the single nucleotide identity at position 23,403 in the viral genome of 96.6% SARS-CoV-2 positive samples without the need for sequencing. This study demonstrates the utility of FEVER to design assays for biosurveillance, diagnostics, and mutation typing to rapidly detect, track, and mitigate future outbreaks and pandemics caused by emerging viruses.

59 BASIC BIOLOGICAL SCIENCES↗

HFTS-2 Completions Design and State-of-the-Art Diagnostics Results

Various completion schemes were tested as part of the Hydraulic Fracture Test Site-2 (HFTS-2) project. The wells were instrumented with permanent fiber optic (FO) cable, and unique near-wellbore and far-field region surveys were acquired to evaluate spatial and temporal hydraulic fracture characteristics. The state-of-the-art diagnostics included substantial monitoring of both the well stimulation and longer-term production performance. The objective was to evaluate and improve stimulation distribution effectiveness (SDE) for different completion designs based on the diagnostics results. A hydraulic fracturing (HF) profile (i.e., proppant/fluid allocation among clusters) was obtained using near-wellbore Distributed Acoustic Sensing (DAS) data acquired during stimulation. Statistical analysis provided a quantitative assessment of SDE for the different completion designs. A novel workflow was developed to assess time-lapse fracture property changes at the cluster and stage levels based on Distributed Strain Sensing (DSS) data acquired during the production phase. These time-lapse fracture property changes were compared with the HF profile. Based on the statistical analysis, Rate Per Cluster (RPC) during proppant slurry placement appears to be a primary completion design variable, rather than the typical Rate Per Perf (RPP). If RPC was not maintained at a certain level, the likelihood of uneven distribution increased dramatically. The stage configurations that created low RPC while maintaining high RPP did not show improved SDE. The strain change results based on DSS data during the production phase indicated near-wellbore fracture property changes (e.g., aperture changes during well shut-in and flow periods) and aligned well with near-wellbore DAS signals acquired during stimulation. More importantly, fracture property changes based on DSS data acquired during two tests over a 7-month period show high consistency and good alignment with the near-wellbore HF profile. This workflow quantitatively evaluates SDE for different completion designs using diagnostic results and could help optimize completion strategy for future development projects. Here, the analysis and interpretation of results demonstrate the technical feasibility of using permanent fiber optic cable for stimulation and production monitoring and indic

58 GEOSCIENCES↗

Understanding the structure and structural degradation mechanisms in high-voltage lithium-ion battery cathode oxides. A review of materials diagnostics

Materials diagnostic techniques are the principal tools used in the development of low-cost, high-performance electrodes for next-generation lithium-based energy storage technologies. Also, this review highlights the importance of materials diagnostic techniques in unraveling the structure and the structural degradation mechanisms in high-voltage, high-capacity oxides that have the potential to be implemented in high-energy-density lithium-ion batteries for transportation that can use renewable energy and is less-polluting than today. The rise in CO 2 concentration in the earth’s atmosphere due to the use of petroleum products in vehicles and the dramatic increase in the cost of gasoline demand the replacement of current internal combustion engines in our vehicles with environmentally friendly, carbon free systems. Therefore, vehicles powered fully/partially by electricity are being introduced into today’s transportation fleet. As power requirements in all-electric vehicles become more demanding, lithium-ion battery (LiB) technology is now the potential candidate to provide higher energy density. Moreover, discovery of layered high-voltage lithium-manganese–rich (HV-LMR) oxides has provided a new direction toward developing high-energy-density LiBs because of their ability to deliver high capacity (~250 mA h/g) and to be operated at high operating voltage (~4.7 V). Unfortunately, practical use of HV-LMR electrodes is not viable because of structural changes in the host oxide during operation that can lead to fundamental and practical issues. This article provides the current understanding on the structure and structural degradation pathways in HV-LMR oxides, and manifests the importance of different materials diagnostic tools to unraveling the key mechanism(s). Furthermore, the fundamental insights reported, might become the tools to manipulate the chemical and/or structural aspects of HV-LMR oxides for low cost, high-energy-density LiB applications.

25 ENERGY STORAGE↗

Photon Beamlines and Diagnostics at LCLS

The Linac Coherent Light Source (LCLS) is the first hard-x-ray free electron laser in operation. The turn-on of LCLS was rapid and operation has been reliable. Performance has exceeded the design parameters in several areas. The photon energy output covers a range from 480 eV to over 9 keV; the pulse energy is typically 2-3 mJ, with a maximum of 4 mJ at 2 keV. Electron pulse lengths can be varied from 500 fs to shorter than 10 fs. A low-charge option at 20 pC is being explored, which delivers pulses shorter than 10 fs with a reduced pulse energy, typically around 0.2 mJ. On-demand, single-shot and multi-shot modes up to 60 Hz (planned is 120 Hz) can be made available. The photon diagnostics built for LCLS have been commissioned and provide measurements of various properties of the FEL beam, such as pulse energy, beam size and position, wavelength, and allows for intensity attenuation over the entire wavelength range. The two soft x-ray instruments, the Atomic Molecular and Optics (AMO) and Soft X-ray Material Science (SXR) stations, are fully operational and completed their second user run in mid September 2010. The third user run is scheduled from October to December 2010, and will include the first hard x-ray instrument X-ray Pump-and-Probe (XPP). Three additional hard x-ray stations will follow: CXI (Coherent X-ray Imaging) is planned to start commissioning in December 2010, the XCS (X-ray correlation spectroscopy) instrument will start in June 2011, and the station for Matter in Extreme Conditions (MEC) in 2012. A list of past and future milestones for LCLS commission and operations is shown in table 1. The LCLS hard x-ray Free Electron Laser at SLAC reported first lasing in April of 2009. Since then two successful user runs have been completed at the two soft x-ray stations. The first hard x-ray station has started commissioning in July of 2010. Beam diagnostics play an essential role for tuning the machine and delivering the requested beam properties to the users. An overview of the LCLS photon diagnostics will be presented including some selected commissioning results. Plans for future improvements and upgrades will be briefly discussed.

43 PARTICLE ACCELERATORS↗

Antibody-Based Diagnostics: Fast Track Production

The major product line for NHD is the development, marketing and sale of rapid antibody based diagnostic kits. Studies conducted by the World Health Organization in 1996 showed that infectious and parasitic diseases accounted for 43% of the 40 million deaths in developing countries. In the United States alone, for example, the death rate due to infectious diseases rose 58% from 1980 to 1992. The incidence of food-borne illness continues to rise. As many as 81 million illnesses and 9,000 deaths occur each year in the United States from food-borne microorganisms. In addition, pesticides in food give rise to an estimated 6,000 cancer cases annually in the U.S. The Environmental Protection Agency (EPA) estimated, in the early 1990s, that approximately 43% of the water systems serving 120 million people had EPA violations, and nearly one million people became ill due to contaminated water. In fact, "Boil Water" alerts have been issued for cities such as Milwaukee, New York City, Washington D.C., and others. With the basic infrastructure in the U.S. water systems being quite old, there remains a risk of system failure and contamination. The largest market driver for the diagnostics business is cost—routine analyses for DOD, EPA, USDA, FDA, WHO and veterinary applications run between $\$3-7$/test. Special high demand tests (usually patent protected and unique, can run $\$15-25$/test). The proposed suite of diagnostics test kits developed under this project is expected to result in penetrating several high volume markets; these include WHO, DOD, CDC, environmental, and food safety sectors.

59 BASIC BIOLOGICAL SCIENCES↗

Application and Continued Development of Thin Faraday Collectors as a Lost Ion Diagnostic for Tokamak Fusion Plasmas

This report summarizes the accomplishment of sixteen years of work toward the development of thin foil Faraday collectors as a lost energetic ion diagnostic for high temperature magnetic confinement fusion plasmas. Following initial, proof of principle accelerator based studies, devices have been tested on TFTR, NSTX, ALCATOR, DIII-D, and JET (KA-1 and KA-2). The reference numbers refer to the attached list of publications. The JET diagnostic KA-2 continues in operation and hopefully will provide valuable diagnostic information during a possible d-t campaign on JET in the coming years. A thin Faraday foil spectrometer, by virtue of its radiation hardness, may likewise provide a solution to the very challenging problem of lost alpha particle measurements on ITER and other future burning plasma machines.

43 PARTICLE ACCELERATORS↗

A Non-invasive beam size diagnostic for ARIA

Presentation slides Diagnostics for ARIA should include noninvasive measurements of beam size for tuning to optimum radiographic performance; The beam size can be measured non- invasively using a diamagnetic loop; Diamagnetic loop theory is well developed, and experiments have been successful; The single major problem encountered in making these measurements on LIAs has been location; A dedicated station for these measurements on ARIA can be easily inserted into either of the DARHT accelerator beam lines for testing; Diagnostic sensitivity depends on dimensions and bias field strength; The ARIA design would provide high-amplitude signals for accurate beam size measurements; The details of loop construction is important to achieve balanced signal output immune to commonmode backgrounds; and Techniques for testing and calibrating diamagnetic loops were developed more than 15 years ago for DARHT diagnostics.

43 PARTICLE ACCELERATORS↗

Spectroscopic Investigations of Highly Charged Tungsten Ions - Atomic Spectroscopy and Fusion Plasma Diagnostics

The spectra of highly charged tungsten ions have been investigated using x-ray and extreme ultraviolet spectroscopy. These heavy ions are of interest in relativistic atomic structure theory, where high-precision wavelength measurements benchmark theoretical approaches, and in magnetic fusion research, where the ions may serve to diagnose high-temperature plasmas. The work details spectroscopic investigations of highly charged tungsten ions measured at the Livermore electron beam ion trap (EBIT) facility. Here, the EBIT-I and SuperEBIT electron beam ion traps have been employed to create, trap, and excite tungsten ions of M- and L-shell charge states. The emitted spectra have been studied in high resolution using crystal, grating, and x-ray calorimeter spectrometers. In particular, wavelengths of n = 0 M-shell transitions in K-like W 55+ through Ne-like W 64+ , and intershell transitions in Zn-like W 44+ through Co-like W 47+ have been measured. Special attention is given to the Ni-like W46+ ion, which has two strong electric-dipole forbidden transitions that are of interest for plasma diagnostics. The EBIT measurements are complemented by spectral modeling using the Flexible Atomic Code (FAC), and predictions for tokamak spectra are presented. The L-shell tungsten ions have been studied at electron-beam energies of up to 122 keV and transition energies measured in Ne-like W 64+ through Li-like W 71+ . These spectra constitute the physics basis in the design of the ion-temperature crystal spectrometer for the ITER tokamak. Tungsten particles have furthermore been introduced into the Sustained Spheromak Physics Experiment (SSPX) spheromak in Livermore in order to investigate diagnostic possibilities of extreme ultraviolet tungsten spectra for the ITER divertor. The spheromak measurement and spectral modeling using FAC suggest that tungsten ions in charge states around Er-like W 6+ could be useful for plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Diagnostics for High Pressure Spray Combustion.

The development of accurate predictive engine simulations requires experimental data to both inform and validate the models, but very limited information is presently available about the chemical structure of high pressure spray flames under engine- relevant conditions. Probing such flames for chemical information using non- intrusive optical methods or intrusive sampling techniques, however, is challenging because of the physical and optical harshness of the environment. This work details two new diagnostics that have been developed and deployed to obtain quantitative species concentrations and soot volume fractions from a high-pressure combusting spray. A high-speed, high-pressure sampling system was developed to extract gaseous species (including soot precursor species) from within the flame for offline analysis by time-of-flight mass spectrometry. A high-speed multi-wavelength optical extinction diagnostic was also developed to quantify transient and quasi-steady soot processes. High-pressure sampling and offline characterization of gas-phase species formed following the pre-burn event was accomplished as well as characterization of gas-phase species present in the lift-off region of a high-pressure n-dodecane spray flame. For the initial samples discussed in this work several species were identified, including polycyclic aromatic hydrocarbons (PAH); however, quantitative mole fractions were not determined. Nevertheless, the diagnostic developed here does have this capability. Quantitative, time-resolved measurements of soot extinction were also accomplished and the novel use of multiple incident wavelengths proved valuable toward characterizing changes in soot optical properties within different regions of the spray flame.

Skeen, Scott A.↗

LCLS Physics Specifications for the SXRSS Beam Overlap Diagnostics

The SXRSS Beam Overlap Diagnostics PRD provides the physics requirements for the overlap diagnostics as part of the SXRSS project for the LCLS undulator. This document covers the overlap diagnostics to be installed after girders 9 and 12 of the LCLS undulators.

ENG↗

Rayleigh Scattering Combustion Diagnostic

A laser Rayleigh scattering (LRS) temperature diagnostic was developed over 8 weeks with the goal of studying oxy-combustion of pulverized coal char in high temperature reaction environments with high concentrations of carbon dioxide. Algorithms were developed to analyze data collected from the optical diagnostic system and convert the information to temperature measurements. When completed, the diagnostic will allow for the kinetic gasification rates of the oxy-combustion reaction to be obtained, which was previously not possible since the high concentrations of high temperature CO 2 consumed thermocouples that were used to measure flame temperatures inside the flow reactor where the combustion and gasification reactions occur. These kinetic rates are important for studying oxy-combustion processes suitable for application as sustainable energy solutions.

01 COAL, LIGNITE, AND PEAT↗

Portable Diagnostics and Rapid Germination

In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

09 BIOMASS FUELS↗

The ICF National Diagnostic Plan (NDP) September 2018

This documents the National Diagnostic Plan as of September 2018, resulting from an August meeting of the NDP leadership group. The substance of the changes in this plan from the NDP document issued in 2017 is in the new schedules and text for the eight national transformative diagnostics - section III, and the many local diagnostics for our three Inertial Confinement Fusion (ICF) facilities; NIF, Z and OMEGA - section V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of pooling strategies of clinical COVID-19 samples for more efficient diagnostic testing

Pooling of COVID-19 clinical samples can offer significant reduction in reagents, time, and labor needed to test large numbers of clinical samples. Especially for testing asymptomatic and return-towork/ school cases, where the prevalence of COVID-19 may be relatively low, large groups of clinical samples can be classified as negative with a single test, with no need to test every sample individually. LANL has performed validation for two different pooling strategies to assess diagnostic assay sensitivity in pooled samples compared to the clinical positive sample alone. (1) Pooling study - Determine diagnostic assay sensitivity in pooled samples with ratios of 1:5, 1:10, 1:20, and 1:30 positive to negative clinical samples. (2) Reloading study - Determine diagnostic assay sensitivity in reloading of multiple clinical samples through a Qiagen column in 5x, 10, and 20x sample volumes (1 positive plus 4, 9, and 19 negative samples).

59 BASIC BIOLOGICAL SCIENCES↗

Developing inductively driven diagnostic X-ray sources to enable transformative radiography and diffraction capabilities on Z

Penetrating X-rays are one of the most effective tools for diagnosing high energy density experiments, whether through radiographic imaging or X-ray diffraction. To expand the X-ray diagnostic capabilities at the 26-MA Z Pulsed Power Facility, we have developed a new diagnostic X-ray source called the inductively driven X-pinch (IDXP). This X-ray source is powered by a miniature transmission line that is inductively coupled to fringe magnetic fields in the final power feed. The transmission line redirects a small amount of Zs magnetic energy into a secondary cavity where 150+ kA of current is delivered to a hybrid X-pinch. In this report, we describe the multi-stage development of the IDXP concept through experiments both on Z and in a surrogate setup on the 1 MA Mykonos facility. Initial short-circuit experiments to verify power ow on Z are followed by short-circuit and X-ray source development experiments on Mykonos. The creation of a radiography-quality X-pinch hot spot is verified through a combination of X-ray diode traces, laser shadowgraphy, and source radiography. The success of the IDXP experiments on Mykonos has resulted in the design and fabrication of an IDXP for an upcoming Z experiment that will be the first-ever X-pinch fielded on Z. We have also pursued the development of two additional technologies. First, the extended convolute post (XCP) has been developed as an alternate method for powering diagnostic X-pinches on Z. This concept, which directly couples the current owing in one of the twelve Z convolute posts to an X-pinch, greatly increases the amount of available current relative to an IDXP (900 kA versus 150 kA). Initial short-circuit XCP experiments have demonstrated the efficacy of power ow in this geometry. The second technology pursued here is the inductively driven transmission line (IDTL) current monitor. These low-current IDTLs seek to measure the current in the final power feed with high fidelity. After three generations of development, IDTL current monitors frequently return cleaner current measurements than the standard B-dot sensors that are fielded on Z. This is especially true on high-inductance experiments where the harshest conditions are created in the nal power feed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗