Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework to Design Consumer-Centric Operational Strategies for Resilience Enhancement

Extreme temperature-related events like heat waves or cold snaps can significantly stress the power distribution grid as electricity demand spikes leading to brownouts or blackouts if not managed properly. In addition, such extreme events can exacerbate inequity, with vulnerable populations (for example, houses with poor insulation, located in non-critical zones, and lack of local resources) at greater risk. There is a growing deployment of distribution systems automation technologies such as advanced metering infrastructure, sensors, and automated control systems to enhance the visibility of the entire distribution grid while meeting resilience objectives. Here, this paper proposes a framework for investigating how automation can improve the distribution system's resilience and ensure customers' health and safety during such extremes. The proposed framework's efficacy will be demonstrated for the Electricity Reliability Council of Texas (ERCOT) during winter storm Uri with varying levels of distribution automation technologies such as feeder isolation using smart switches, remote outage signals using advanced meters, and comfort-aware outage using advanced analytics and communication. Simulation results show that an outage strategy involving advanced grid technology and communication can reduce the occupant exposure to severe cold by 93% and, simultaneously, reduce expected energy not served by 73.2% when compared against feeder isolation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volt/VAR Optimization (VVO) Application on GridAPPS-D Platform

There is a large increment in the distributed energy resources (DERs) installation and deployments of smart sensing devices and communication infrastructure; hence, the power distribution network is swiftly evolving from a passive network to an active network. This motivates the development of advanced applications to operate power distribution systems for higher efficiency and reliability. These advanced applications are model-based and data-driven. This requires an advanced distribution management system (ADMS) to provide required data for the optimal operation of the distribution systems by coordinating various grid controllable devices. In this paper a Volt-VAR optimization (VVO) application to coordinate the grid’s legacy and new voltage control devices for conservation voltage reduction (CVR) is deployed on the GridAPPS-D platform (an open-source platform ) for ADMS application development. The VVO application is validated for various operating conditions on using modified IEEE 8500-node distribution test feeders. Further, the application is successfully deployed on the GridAPPS-D platform.

Jha, Rahul↗

A Fast Scalable Quasi-Static Time Series Analysis Method for PV Impact Studies Using Linear Sensitivity Model

Understanding the impact of distributed photovoltaic (PV) resources on various elements of the distribution feeder is imperative for their cost effective integration. A year-long quasi-static time series (QSTS) simulation at 1-second granularity is often necessary to fully study these impacts. However, the significant computational burden associated with running QSTS simulations is a major challenge to their adoption. In this paper, we propose a fast scalable QSTS simulation algorithm that is based on a linear sensitivity model for estimating voltage-related PV impact metrics of a three-phase unbalanced, nonradial distribution system with various discrete step control elements including tap changing transformers and capacitor banks. Here, the algorithm relies on computing voltage sensitivities while taking into account all the effects of discrete controllable elements in the circuit. Consequently, the proposed sensitivity model can accurately estimate the state of controllers at each time step and the number of control actions throughout the year. For the test case of a real distribution feeder with 2969 buses (5469 nodes), 6 load/PV time series power profiles, and 9 voltage regulating elements including controller delays, the proposed algorithm demonstrates a dramatic time reduction, more than 180 times faster than traditional QSTS techniques.

14 SOLAR ENERGY↗

PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RADIANCE Executive Summary

Microgrids are gaining attention from organizations and cities because of their potential reliability and resilience benefits, especially in remote geographic areas: Microgrids can provide local power during emergencies, and they can reduce the costs of imported fuel by reducing overall fuel use. But the complexities and novelties of microgrid technologies are often barriers to deployment that require testing and validation to overcome. This report describes the testing, validation, and deployment of microgrid technologies in Cordova, Alaska, completed through the U.S. Department of Energy (DOE) Grid Modernization Laboratory Consortium (GMLC) project Resilient Alaskan Distribution system Improvements using Automation, Network analysis, Control, and Energy storage (RADIANCE).

ARIES↗

Electrostatic modulation of the lateral carrier density profile in field effect devices with nonlinear dielectrics

The properties of two-dimensional (2D) electronic systems are often effectively controlled using electrostatic gating. The geometry of such field effect devices influences the effectiveness of the gate and the carrier density profile in the 2D device. Here, in this work, we analyze the gate-induced spatial variations in the lateral carrier density in patterned LaAlO 3 /SrTiO 3 devices. We model the electrostatics of the 2D interface using the Thomas-Fermi approximation and compute the gate-induced charge distribution at the interface. We show that the electric field lines generated by the gate are focused at the edges of the device, causing an increased depletion near its edges. This effect is accentuated in LaAlO 3 /SrTiO 3 due to the large, nonlinear dielectric constant of the substrate, and the large distance between the gate electrode and the interface. We experimentally demonstrate one consequence of this effect by directly imaging current distributions in gated heterostructures, finding that insulating regions nucleate at the edges of the device due to the gate. Our results suggest that device geometry and choice of dielectric materials control the charge distribution in 2D systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Entropy of the Quantum–Classical Interface: A Potential Metric for Security

Hybrid quantum–classical systems are emerging as key platforms in quantum computing, sensing, and communication technologies, but the quantum–classical interface (QCI)—the boundary enabling these systems—introduces unique and largely unexplored security vulnerabilities. This position paper proposes using entropy-based metrics to monitor and enhance security, specifically at the QCI. We present a theoretical security outline that leverages well-established information-theoretic entropy measures, such as Shannon entropy, von Neumann entropy, and quantum relative entropy, to detect anomalous behaviors and potential breaches at the QCI. By linking entropy fluctuations to scenarios of practical relevance—including quantum key distribution, quantum sensing, and hybrid control systems—we promote the potential value and applicability of entropy-based security monitoring. While explicitly acknowledging practical limitations and theoretical assumptions, we argue that entropy-based metrics provide a complementary approach to existing security methods, inviting further empirical studies and theoretical refinements that can strengthen future quantum technologies.

97 MATHEMATICS AND COMPUTING↗

National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR) power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Locational Marginal Pricing (DLMP) for Congestion Management and Voltage Support

In this paper, a day-ahead market-clearing model for smart distribution systems is proposed. Various types of distributed energy resources (DERs), such as distributed energy storage, distributed generators, microgrids, and load aggregators, can bid into the day-ahead distribution-level electricity market. Considering system Volt/VAR control, network reconfiguration, and interactions with the wholesale market, an optimization model is built to clear the day-ahead market, through which the distribution locational marginal pricing (DLMPs) for both active power and reactive power are determined. Through derivations of the Lagrangian function and sensitivity factors, DLMPs are decomposed to five components (i.e., marginal costs for active power, reactive power, congestion, voltage support, and loss), which provide price signals to motivate DERs to contribute to congestion management and voltage support. Finally, case studies demonstrate the effectiveness of the proposed method.

congestion management↗

Comparison of Routable Control System Security Approaches

This document is an supplement to the 'Secure and Efficient Routable Control Systems.' It addressed security in routable control system communication. The control system environment that monitors and manages the power grid historically has utilized serial communication mechanisms. Leased-line serial communication environments operating at 1200 to 9600 baud rates are common. However, recent trends show that communication media such as fiber, optical carrier 3 (OC-3) speeds, mesh-based high-speed wireless, and the Internet are becoming the media of choice. In addition, a dichotomy has developed between the electrical transmission and distribution environments, with more modern communication infrastructures deployed by transmission utilities. The preceding diagram represents a typical control system. The Communication Links cloud supports all of the communication mechanisms a utility might deploy between the control center and devices in the field. Current methodologies used for security implementations are primarily led by single vendors or standards bodies. However, these entities tend to focus on individual protocols. The result is an environment that contains a mixture of security solutions that may only address some communication protocols at an increasing operational burden for the utility. A single approach is needed that meets operational requirements, is simple to operate, and provides the necessary level of security for all control system communication. The solution should be application independent (e.g., Distributed Network Protocol/Internet Protocol [DNP/IP], International Electrotechnical Commission [IEC] C37.118, Object Linking and Embedding for Process Control [OPC], etc.) and focus on the transport layer. In an ideal setting, a well-designed suite of standards for control system communication will be used for vendor implementation and compliance testing. An expected outcome of this effort is an international standard.

99 GENERAL AND MISCELLANEOUS↗

A Testbed for Deploying Distributed State Estimation in Power Grid

Abstract—With the increasing demand, scale and data information of power systems, fast distributed applications are becoming more important in power system operation and control. This paper proposes a testbed for evaluating power system distributed applications, considering data exchange among distributed areas. A high-performance computing (HPC) version of distributed state estimation is implemented and used as a distributed application example. The IEEE 118-bus system is used to deploy the parallel distributed state estimation, and the MeDICi middleware is used for data communication. The performance of the testbed demonstrates its capability to evaluate parallel distributed state estimation by leveraging the HPC paradigm. This testbed can also be applied to evaluate other distributed applications.

distributed state estimation↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Features Of The J-PARC Linac

Japan Proton Accelerator Research Complex (J-PARC) will be one of the highest intensity proton accelerators in the world aiming to realize 1 MW class of the beam power. The accelerator consists of a 400-MeV linac, a 3-GeV rapid-cycling synchrotron (RCS) and a main ring synchrotron (MR), and the accelerated beam is applied to several experimental facilities. The linac, which is the injector for the RCS, has about 50 cavity modules to accelerate the beam up to 400 MeV. The acceleration field error in all of them should be within {+-}1% in amplitude and {+-}1 degree in phase because the momentum spread of the RCS injection beam is required to be within 0.1%. For the cavity field stabilization, a high-stable optical signal distribution system is used as the RF reference, and sophisticated digital feedback and feed-forward system is working well in the low level RF control system. Consequently the providing beam to the RCS is very stable, and the beam commissioning and the experiments of the application facilities have been progressed steadily.

43 PARTICLE ACCELERATORS↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

BioMass PDU Electrical Design Study UPDATE

The BioMass Process Demonstration Unit (PDU) electrical system is used for the power distribution and control of the many motors and process required loads. Study requirements include a complete system analysis and equipment evaluation, which includes conductor sizing, transformer sizing, breaker and fuse sizing, short-circuit analysis, load-flow analysis, protective-device coordination, arc-flash-hazard analysis, and a multi-state code and grounding review.

09 BIOMASS FUELS↗

Adaptive protection opportunities, gap assessments, and designs

This report provides a comprehensive overview of adaptive protection schemes in use by distribution systems for protection, switching and control on their systems. A significant focus is placed on how existing schemes can be impacted by increasing penetrations of DER as well as how these schemes can enable DER penetrations to increase. EPRI have conducted a survey of member utilities and performed a comprehensive literature review with the goal of baselining the research and identifying gaps with a focus on the issues that were encountered with adaptive protection on real systems. The five adaptive protection applications that are most prevalent on systems today are discussed in detail. These are weather-based fuse-saving, adaptive protection to reduce short-circuit current, adaptive protection for DER, adaptive protection for microgrids, and distribution automation. A broad overview of the technology is given for each scheme. Issues that have been encountered by utilities are highlighted and the safety and reliability impacts are also examined. As distribution systems, intelligent electronic devices, grid equipment and distribution management systems are rapidly evolving, adaptive protection techniques and technologies will become more widely adopted. This report proposes a framework for a conceptual automatic adaptive protection system. EPRI have ongoing research, development and demonstration projects in all of the constituent elements, however challenges remain to link the elements together in a secure and reliable way. EPRI will continue research into automated adaptive protection applications and challenges for the systems of today and future applications to assist system operators in managing the evolving system.

14 SOLAR ENERGY↗