Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Effectiveness of State-Level Policies on Solar Market Development in Different State Contexts

In response to public interest in customer-sited distributed solar photovoltaics (PV), state and local policymakers have implemented policy initiatives with the goal of encouraging private investment and building a robust PV market. Policymakers face challenges, including limited budgets and incomplete information about the effectiveness of the various policy options in their specific situation, in crafting and executing policy that supports market development goals. Recent work investigated the effect of the order in which policies are implemented (referred to as 'policy stacking') and the presence of low-cost enabling policies, such as interconnection standards and net metering, can have on the success of states in promoting PV markets. Findings indicate that implementation of interconnection standards and policy related to the valuation of excess electricity (e.g., net metering), along with indicators of long term government support for a solar PV market (e.g., RPS) and a non-policy determinant (population), explain about 70% of the variation among states in new PV capacity. This paper builds on that research to determine the most effective policy strategies for different types of states, as determined by their physical, demographic and macroeconomic context. A number of researchers have investigated the effectiveness of state-level policy using various statistical methods to determine relationships between installed solar PV projects and policy initiatives. In this study, the grouping of states by non-policy factors adds dimension to these analyses by identifying how policies function in different non-policy environments.

14 SOLAR ENERGY↗

CRADA 376 Final Report Development of Protective Coatings for 1 kW Hot Zone

Pacific Northwest National Laboratory (PNNL) has extensive experience in the development, fabrication, and evaluation of surface treatments and protective coatings for metallic solid oxide fuel cell (SOFC) components. For example, modified (Mn,Co)3O4 spinel coatings and coating/metal interfaces have been shown to substantially improve oxidation resistance, electrical performance, and oxide scale adhesion of ferritic stainless steel interconnects in planar SOFC stacks. At the time of the establishment of this CRADA, Protonex Technology Corporation had been working in the field of SOFC development for over 12 years and had demonstrated more than 250 thermal cycles with a less than 15 minutes start time and more than 2000 hours of continuous operation on a 250W tubular solid oxide hot zone module as part of a program for the Office of the Secretary of Defense (OSD). An industrial version of the military system, denoted P200i, had been developed that was launched at the 2015 Fuel Cell Expo in Tokyo. Feedback during beta testing of this unit was very positive. However, Protonex recognized that to transition from military markets, the commercial system would require longer life time and higher power. Leveraging their novel thermal management strategy from the tubular hot zone that allowed for rapid and repeated thermal cycling, Protonex developed a planar 1kW module aimed at the industrial and commercial market. However, more robust interconnect coatings were needed to bring the system into the 1000+ hour life time requested by customers. Therefore, PNNL’s experience and technology were engaged to enable the 1kw system to transition from military applications to commercial and industrial applications. In this CRADA, PNNL teamed with Protonex to leverage PNNL’s expertise in protective coating techniques for solid oxide fuel cell (SOFC) applications. As the first step in the collaboration, protective spinel coatings were fabricated at PNNL onto ten AISI 440 stainless steel bus bars provided by Protonex. A precursor slurry containing spinel powder was applied to the steel surfaces via an ultrasonic spray process. The coated bars were then subjected to a reducing atmosphere heat treatment (i.e., heated to 850°C at 3°C/min in a hydrogen atmosphere and held at that temperature for five hours). Five of the bars were left in this reduced condition; the other five bars were subjected to an oxidizing heat treatment (i.e., heated to 1000°C at 3°C/min in air and held at that temperature for one hour). The bars were then sent to Protonex for testing. Subsequently, Protonex decided to discontinue their SOFC development activities, so they had no further interest in continuing the collaboration with PNNL, and the CRADA activities were terminated.

30 DIRECT ENERGY CONVERSION↗

100% Carbon-Free Electricity for Sandia NM and KAFB Using Concentrating Solar Power (CSP) (SAND Report)

This report provides a design study to produce 100% carbon-free electricity for Sandia NM and Kirtland Air Force Base (KAFB) using concentrating solar power (CSP). Annual electricity requirements for both Sandia and KAFB are presented, along with specific load centers that consume a significant and continuous amount of energy. CSP plant designs of 50 MW and 100 MW are then discussed to meet the needs of Sandia NM and the combined electrical needs of both Sandia NM and KAFB. Probabilistic modeling is performed to evaluate inherent uncertainties in performance and cost parameters on total construction costs and the levelized cost of electricity. Total overnight construction costs are expected to range between ~$300M - $400M for the 50 MW CSP plant and between ~$500M - $800M for the 100 MW plant. Annual operations and maintenance (O&M) costs are estimated together with potential offsets in electrical costs and CO 2 emissions. Other considerations such as interconnections, land use and permitting, funding options, and potential agreements and partnerships with Public Service Company of New Mexico (PNM), Western Area Power Administration (WAPA), and other entities are also discussed.

14 SOLAR ENERGY↗

The Role of the U.S. Electric Distribution System in Serving Data Center and Other Large Loads

The rapid expansion of data centers in the United States is reshaping how the electric distribution system must plan for and accommodate large load interconnections. This report evaluates the role of the distribution grid in serving these loads, from small edge facilities to hyperscale campuses. Using national datasets, utility filings, and industry studies, we assess demand growth, reliability requirements, interconnection thresholds, and infrastructure needs at substations and feeders. The analysis highlights the mismatch between fast data center development timelines and slower utility planning and construction cycles, as well as strategies such as phased energization, on-site generation, hosting capacity maps, and structured interconnection frameworks. While focused on data centers, the insights also apply to other high-density loads such as advanced manufacturing, hydrogen production, and electrified transportation. The report concludes with approaches to align planning processes, transparency tools, and regulatory frameworks so utilities can manage new large loads in ways that support a reliable and resilient grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High temperature - low mass solar blanket

Interconnect materials and designs for use with ultrathin silicon solar cells are discussed, as well as the results of an investigation of the applicability of parallel-gap resistance welding for interconnecting these cells. Data relating contact pull strength and cell electrical degradation to variations in welding parameters such as time, voltage and pressure are presented. Methods for bonding ultrathin cells to flexible substances and for bonding thin (75 micrometers) covers to these cells are described. Also, factors influencing fabrication yield and approaches for increasing yield are discussed. The results of vacuum thermal cycling and thermal soak tests on prototype ultrathin cell test coupons and one solar module blanket are presented.

Mesch, H. G.↗

An analysis of space power system masses

Various space electrical power system masses are analyzed with particular emphasis on the power management and distribution (PMAD) portion. The electrical power system (EPS) is divided into functional blocks: source, interconnection, storage, transmission, distribution, system control and load. The PMAD subsystem is defined as all the blocks between the source, storage and load, plus the power conditioning equipment required for the source, storage and load. The EPS mass of a wide range of spacecraft is then classified as source, storage or PMAD and tabulated in a database. The intent of the database is to serve as a reference source for PMAD masses of existing and in-design spacecraft. The PMAD masses in the database range from 40 kg/kW to 183 kg/kW across the spacecraft systems studied. Factors influencing the power system mass are identified. These include the total spacecraft power requirements, total amount of load capacity and physical size of the spacecraft. It is found that a new utility class of power systems, represented by Space Station Freedom, is evolving.

Kenny, Barbara H.↗

An analysis of space power system masses

Various space electrical power system masses are analyzed with particular emphasis on the power management and distribution (PMAD) portion. The electrical power system (EPS) is divided into functional blocks: source, interconnection, storage, transmission, distribution, system control and load. The PMAD subsystem is defined as all the blocks between the source, storage and load, plus the power conditioning equipment required for the source, storage and load. The EPS mass of a wide range of spacecraft is then classified as source, storage or PMAD and tabulated in a database. The intent of the database is to serve as a reference source for PMAD masses of existing and in-design spacecraft. The PMAD masses in the database range from 40 kg/kW to 183 kg/kW across the spacecraft systems studied. Factors influencing the power system mass are identified. These include the total spacecraft power requirements, total amount of load capacity and physical size of the spacecraft. It is found that a new utility class of power systems, represented by Space Station Freedom, is evolving.

Kenny, Barbara H.↗

Self-assembled tunable networks of sticky colloidal particles

Self-assembled tunable networks of microscopic polymer fibers ranging from wavy colloidal "fur" to highly interconnected networks are created from polymer systems and an applied electric field. The networks emerge via dynamic self-assembly in an alternating (ac) electric field from a non-aqueous suspension of "sticky" polymeric colloidal particles with a controlled degree of polymerization. The resulting architectures are tuned by the frequency and amplitude of the electric field and surface properties of the particles.

36 MATERIALS SCIENCE↗

Interconnect for fuel cell stack

A metal interconnect for a fuel cell stack is formed from an electrically conductive metal sheet having at least four stamped slots through the metal sheet, and often many more than four slots. The stamped slots individually extend lengthwise parallel to the direction of fluid flow during operation of the fuel cell stack assembly and are disposed on the metal sheet in a pattern extending parallel and perpendicular to the direction of fluid flow, so as to define at least one metal strip portion between adjacent slots extending parallel to the direction of fluid flow and at least one metal strip portion between adjacent slots extending perpendicular to the direction of fluid flow. The metal strip portion(s) include portions of reduced thickness that allow for fluid flow between adjacent slots and portions of greater thickness that provide discrete locations of electrical connection between the separator plate fuel cell electrode.

30 DIRECT ENERGY CONVERSION↗

Relevance of Generation Interconnection Procedures to Feed-in Tariffs in the United States

Feed-in tariffs (FITs) have been used to promote renewable electricity development in over 40 countries throughout the past two decades. These policies generally provide guaranteed prices for the full system output from eligible generators for a fixed time period (typically 15-20 years). Due in part to the success of FIT policies in Europe, some jurisdictions in the United States are consideringimplementing similar policies, and a few have already put such policies in place. This report is intended to offer some guidance to policymakers and regulators on how generator interconnection procedures may affect the implementation of FITs and how state generator interconnection procedures can be formulated to support state renewable energy objectives. This report is based on a literaturereview of model interconnection procedures formulated by several organizations, as well as other documents that have reviewed, commented on, and in some cases, ranked state interconnection procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ground-referenced single-ended signaling connected graphics processing unit multi-chip module

A system of interconnected chips comprising a multi-chip module (MCM) includes a processor chip, a system functions chip, and an MCM package configured to include the processor chip, the system functions chip, and an interconnect circuit. The processor chip is configured to include a first ground-referenced single-ended signaling interface circuit. A first set of electrical traces manufactured within the MCM package and configured to couple the first single-ended signaling interface circuit to the interconnect circuit. The system functions chip is configured to include a second single-ended signaling interface circuit and a host interface. A second set of electrical traces manufactured within the MCM package and configured to couple the host interface to at least one external pin of the MCM package. In one embodiment, each single-ended signaling interface advantageously implements ground-referenced single-ended signaling.

Dally, William J.↗

Radio frequency component and method of making same

An electrical component and a method of constructing it are disclosed. The component includes a hollow tubular structure. The structure includes a series of axially spaced apart rings and at least one outer perimeter housing member. The housing member interconnects the rings for defining an internal configuration of the hollow tubular structure for electrical purposes. The rings and the housing member each include inter-engageable elements for helping secure mechanically the rings and housing member together to facilitate final assembly of the electrical component.

Pryor, Mark K.↗

On-Board AC Charging Topology Integrated with Electric Vehicle Motor Drive System

On-board AC charging is a convenient and widely adopted method for recharging electric vehicles (EVs) directly from standard alternating current (AC) power sources. This paper presents a novel topology for AC charging of EVs that utilizes EV 3-phase electric machine windings as the input inductors, thus eliminating the requirement for bulky grid interfacing inductors and resulting in a compact and cost-effective integrated motor drive and charger system. The proposed approach leverages the motor windings and parallel operating half-bridge inverter during the charging process by interconnecting the inverter phases with the motor windings in a mechanically interleaved and electrically paralleled manner. The implementation of this unique and innovative idea, achieved through precise control and arrangement of the motor winding as a series inductor, successfully eliminates the possibility of unintended motion of the electric machine during the charging process.

ADVANCED PROPULSION SYSTEMS↗

Development of a Thin-Film Solar Cell Interconnect for the Powersphere Concept

Dual junction amorphous silicon (a-Si) solar cells produced on polyimide substrate have been selected as the best candidate to produce a lightweight solar array for the PowerSphere program. The PowerSphere concept features a space-inflatable, geodetic solar array approximately 0.6 meters in diameter and capable of generating about 20W of electrical power. Trade studies of various wiring concepts and connection methods led to an interconnect design with a copper contact that wraps around the edge, to the back of the solar cell. Applying Plasma Vapor Deposited (PVD) copper film to both sides and the edge of the solar cell produces the wrap around contact. This procedure results in a contact pad on the back of the solar cell, which is then laser welded to a flex circuit material. The flex circuit is constructed of copper in a custom designed routing pattern, and then sandwiched in a Kapton insulation layer. The flex circuit then serves as the primary power distribution system between the solar cells and the spacecraft. Flex circuit material is the best candidate for the wiring harness because it allows for low force deployment of the solar cells by the inflatable hinges on the PowerSphere. An additional frame structure, fabricated and assembled by ILC Dover, will reinforce the wrap around contact-flex blanket connection, thus providing a mechanically robust solar cell interconnect for the PowerSphere multifunctional program. The PowerSphere team will use the wraparound contact design approach as the primary solution for solar cell integration and the flex blanket for power distribution.

Simburger, Edward J.↗

Expanding market opportunities: cogeneration strategies for integrated PWR and thermal energy storage systems

We assess the economic viability of nuclear cogeneration by investigating three different modes—fixed dispatch, fully flexible dispatch, and flexible dispatch with minimum heat supply requirements. The analysis focuses on an existing pressurized water reactor (PWR) integrated with thermal energy storage (TES). Heat production costs are estimated under these modes for two U.S. electricity markets: the Electric Reliability Council of Texas (ERCOT) and the Pennsylvania–New Jersey–Maryland Interconnection (PJM). A sensitivity analysis examines profitability at varying heat market prices. Results indicate that fixed heat dispatch inflates heat production costs, often rendering projects economically feasible only at higher heat price levels. Fully-flexible dispatch lowers heat production costs by an average of 43 % compared to fixed dispatch. However, the current 30 % thermal dispatch limit may be insufficient to serve high baseline industrial demands cost‐effectively; higher maximum dispatch rates could enhance project economics. Markets with higher and more volatile electricity prices (e.g., ERCOT) offer greater total energy sales potential (i.e., heat and electricity), but also increase opportunity costs when heat production scheduling restrictions are imposed. In contrast, lower-price, less volatile markets (e.g., PJM) experience smaller impacts from such constraints and provide greater flexibility in accommodating varying cogeneration modes. In conclusion, these findings provide a framework to guide nuclear plant operators in aligning cogeneration strategies with industrial process requirements and electricity market conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk-informed Hierarchical Control of Behind-the-Meter DERs with AMI Data Integration (Final Technical Report)

This project addresses several key barriers to implement the next generation demand response applications and provides a clear understanding of implementing hierarchical and standalone control using AMI data. Through this program, Eaton has developed and tested a meter-as-a-controller prototype with the help of other partners--- National Renewable Energy Laboratory (NREL), Electric Power Research Institute (EPRI), Pecan St Inc. (PSI), and Delaware Electric Cooperative (DEC). The controller can utilize residential controllable loads such as heating, ventilation, and air conditioner (HVAC), electric water heater and distributed energy resources like solar PV and battery energy storage systems for off-setting the demand that is required from the grid, thus providing reliable grid-services for demand reduction or peak shaving. The controller is also capable of coordinating the resources of the premises for better management and energy efficiency while meeting the comfort bound of the premises owner as quality-of-service. The development has been demonstrated in a three virtual-home setup at system performance lab of NREL with real appliances (HVAC, electric water heater, solar PV, and battery). The technology has also been proved through laboratory and field demonstration with successful interconnectivity (e.g., end-to-end communication and data exchange) between the residential appliances and utility through the RF network at Delaware Electric Co-op (DEC) in Delaware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Planning and Operations in Electricity Markets Under System Tansformation: Key Findings

This report summarizes a set of key findings that have been developed through a set of interconnected research activities performed by five institutions between January 2020 and December 2023. The project team, comprising Argonne National Laboratory, the National Renewable Energy Laboratory, Lawrence Berkeley National Laboratory, the Electric Power Research Institute, and Johns Hopkins University, collective engaged with the North American Independent System Operators and Regional Transmission Operators (ISO/RTOs) to identify the key challenges they are facing and opportunities for the project team to provide technical assistance in several prioritized challenge areas.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗