Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Reliability of Quantitative Ultrasonic Assessment of Normal-Tissue Toxicity in Breast Cancer Radiotherapy

Purpose: We have recently reported that ultrasound imaging, together with ultrasound tissue characterization (UTC), can provide quantitative assessment of radiation-induced normal-tissue toxicity. This study's purpose is to evaluate the reliability of our quantitative ultrasound technology in assessing acute and late normal-tissue toxicity in breast cancer radiotherapy. Method and Materials: Our ultrasound technique analyzes radiofrequency echo signals and provides quantitative measures of dermal, hypodermal, and glandular tissue toxicities. To facilitate easy clinical implementation, we further refined this technique by developing a semiautomatic ultrasound-based toxicity assessment tool (UBTAT). Seventy-two ultrasound studies of 26 patients (720 images) were analyzed. Images of 8 patients were evaluated for acute toxicity (<6 months postradiotherapy) and those of 18 patients were evaluated for late toxicity ({>=}6 months postradiotherapy). All patients were treated according to a standard radiotherapy protocol. To assess intraobserver reliability, one observer analyzed 720 images in UBTAT and then repeated the analysis 3 months later. To assess interobserver reliability, three observers (two radiation oncologists and one ultrasound expert) each analyzed 720 images in UBTAT. An intraclass correlation coefficient (ICC) was used to evaluate intra- and interobserver reliability. Ultrasound assessment and clinical evaluation were also compared. Results: Intraobserver ICC was 0.89 for dermal toxicity, 0.74 for hypodermal toxicity, and 0.96 for glandular tissue toxicity. Interobserver ICC was 0.78 for dermal toxicity, 0.74 for hypodermal toxicity, and 0.94 for glandular tissue toxicity. Statistical analysis found significant changes in dermal (p < 0.0001), hypodermal (p = 0.0027), and glandular tissue (p < 0.0001) assessments in the acute toxicity group. Ultrasound measurements correlated with clinical Radiation Therapy Oncology Group (RTOG) toxicity scores of patients in the late toxicity group. Patients with RTOG Grade 1 or 2 had greater ultrasound-assessed toxicity percentage changes than patients with RTOG Grade 0. Conclusion: Early and late radiation-induced effects on normal tissue can be reliably assessed using quantitative ultrasound.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture Toughness Evaluation for Sandia Mock-up Stainless Steel Canister Weldment Using Spiral Notch Torsion Fracture Toughness Test

Many radioactive materials within the nuclear fuel cycle present a significant hazard. Such materials include spent nuclear fuel, high-level waste, legacy waste and other nuclear materials that have no current outlet than storage. These materials are often held in long-term storage as an interim stage within their lifecycle. Lifecycles can include reuse or disposal. Safety and security of spent nuclear fuel (SNF) interim storage installations are very important, due to a great concentration of fission products, actinides and activation products. Stress corrosion cracking of interim storage containers has been identified as a high priority data gap by the Department of Energy. However, little has been done with regards to the canister weld material properties, including the fracture toughness, and their impact on stress corrosion, until recently from Sandia National Laboratory canister mockup program. Furthermore, because no post-weld heat treatment was required, the associated high tensile residual stress within these canister welds can drive the initiation and growth of stress corrosion cracking (SCC) cracks. Thus, the fracture mechanical property, such as fracture toughness, is an essential information to understand the canister weldment fracture resistance behavior and to support mitigation protocol development to counter SCC. In this work, we carried out fracture toughness evaluation on the received mock-up canister weldments from Sandia, using spiral notch torsion fracture test technology. The details of the weldment fracture toughness evaluation program development at ORNL are presented in this progress report. The objective of this research is to collect fracture toughness data on the mock-up canister weldment from Sandia National Laboratory. Data will be collected under quasi-static fracture loading using the Oak Ridge National Laboratory (ORNL) developed Spiral Notch Torsion Test (SNTT) technology carried out on a biaxial tension/torsion tester. These data will be used to support the ongoing SNF dry storage canister modeling activities and to address regulatory issues associated with canister container integrity and the follow-on SNF system transport reliability. SNTT has been a recent breakthrough in measuring fracture toughness for different materials, including metals, ceramics, concrete and polymers composites. Due to its high geometry constraint and unique loading condition, SNTT can be used to measure the fracture toughness with smaller specimens without concern of size effects. The application of SNTT to brittle materials has been proved to be successful. The micro-cracks induced by original notches in brittle materials could ensure crack growth in SNTT samples. Therefore, no fatigue pre-cracks are needed. The application of SNTT to the ductile material to generate valid toughness data will require a test sample with sufficient crack length to increase the sample fracture tip localized constraint. Fatigue pre-crack growth techniques are employed to introduce sharp crack front into the sample. Previously, only rough calculations were applied to estimate the compliance evolution in the SNTT crack growth process; while accurate quantitative descriptions have never been attempted. This generates an urgent need to understand the crack evolution during the SNTT fracture testing process of ductile materials. The newly developed governing equations for SNTT crack growth estimate are used to control the fatigue crack growth to effectively reaching the target crack length. The detailed SNTT approach and its estimated fracture toughness for the as-received Sandia canister weldment and the associated baseline 304 stainless steel are presented in this report. In the past SNTT technology has also been successfully applied to investigate the fracture behavior of X52 and X80 steels and the X52 welded materials used for hydrogen infrastructures. The current study in supporting Sandia SNF Dry Storage Mock-up Canister Program is the first attempt of applying SNTT to the highly ductile stainless steel and the associated weld materials. The SNTT test results indicate that SNTT method is a reliable test approach with good repeatability in applying to SS304 steel and SS304/308 weld material. The estimate JQ upon fracture for the baseline SS304 steel is at 1618 lb/in. The estimate JQ upon fracture for the SS304/308 weld from HAZ and weld specimens are 720 lb/in and 850 lb/in, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical and genetic blockade of HDACs enhances osteogenic differentiation of human adipose tissue-derived stem cells by oppositely affecting osteogenic and adipogenic transcription factors

Highlights: Black-Right-Pointing-Pointer Acetylation affected hASCs osteodifferentiation through Runx2-PPAR{gamma}. Black-Right-Pointing-Pointer HDACs knocking-down favoured the commitment effect of osteogenic medium. Black-Right-Pointing-Pointer HDACs silencing early activated Runx2 and ALP. Black-Right-Pointing-Pointer PPAR{gamma} reduction and calcium/collagen deposition occurred later. Black-Right-Pointing-Pointer Runx2/PPAR{gamma} target genes were modulated in line with HDACs role in osteo-commitment. -- Abstract: The human adipose-tissue derived stem/stromal cells (hASCs) are an interesting source for bone-tissue engineering applications. Our aim was to clarify in hASCs the role of acetylation in the control of Runt-related transcription factor 2 (Runx2) and Peroxisome proliferator activated receptor (PPAR) {gamma}. These key osteogenic and adipogenic transcription factors are oppositely involved in osteo-differentiation. The hASCs, committed or not towards bone lineage with osteoinductive medium, were exposed to HDACs chemical blockade with Trichostatin A (TSA) or were genetically silenced for HDACs. Alkaline phosphatase (ALP) and collagen/calcium deposition, considered as early and late osteogenic markers, were evaluated concomitantly as index of osteo-differentiation. TSA pretreatment, useful experimental protocol to analyse pan-HDAC-chemical inhibition, and switch to osteogenic medium induced early-osteoblast maturation gene Runx2, while transiently decreased PPAR{gamma} and scarcely affected late-differentiation markers. Time-dependent effects were observed after knocking-down of HDAC1 and 3: Runx2 and ALP underwent early activation, followed by late-osteogenic markers increase and by PPAR{gamma}/ALP activity diminutions mostly after HDAC3 silencing. HDAC1 and 3 genetic blockade increased and decreased Runx2 and PPAR{gamma} target genes, respectively. Noteworthy, HDACs knocking-down favoured the commitment effect of osteogenic medium. Our results reveal a role for HDACs in orchestrating osteo-differentiation of hASCs at transcriptional level, and might provide new insights into the modulation of hASCs-based regenerative therapy.

60 APPLIED LIFE SCIENCES↗

Evaluation of methods to assess the uncertainty in estimated energy savings

In this work we present a methodology to evaluate the accuracy of methods used to quantify the uncertainty in estimated total energy savings. We focus on savings measurement and verification (M&V) approaches that use a baseline model to characterize energy use, and that forward-project the model for a counterfactual to determine avoided energy use. These approaches are common to the International Performance Measurement and Verification Protocol's (IPMVP's) Option C and Option B. This methodology can be used to evaluate the uncertainty in savings estimates that are due to model error. It has been applied to evaluate two uncertainty estimation methods, including the industry standard ASHRAE Guideline 14 approach. The evaluation used data from 69 commercial buildings and four different baseline models that span daily and hourly granularity, as well as linear and non-linear/non-parametric forms. The findings of this work indicate that the standard methods that are widely used by the M&V community for estimating the total savings uncertainty over the post-installation period tend to underestimate the uncertainty. The tendency to underestimate the uncertainty is stronger for hourly models than for daily models, due to stronger autocorrelation in model residuals at the hourly time scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of Remote 3-Dimensional Image Guided Radiation Therapy Quality Assurance for Radiation Therapy Oncology Group Clinical Trials

Purpose: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. Methods and Materials: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities. Results: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases. Conclusion: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of a three-phase adaptive radiotherapy for nasopharyngeal carcinoma using helical tomotherapy

Adaptive radiotherapy (ART) has been introduced to correct the radiation-induced anatomic changes in head and neck cases during a treatment course. This study evaluated the potential dosimetric benefits of applying a 3-phase adaptive radiotherapy protocol in nasopharyngeal carcinoma (NPC) patients compared with the nonadaptive single-phase treatment protocol. Ten NPC patients previously treated with this 3-phase radiation protocol using Hi-Art Tomotherapy were recruited. Two new plans, PII-ART and PIII-ART, were generated based on the up-to-date computed tomography (CT) images and contours and were used for treatment in phase two (PII; after 25th fraction) and phase three (PIII; after 35th fraction), respectively. To simulate the situation of no replanning, 2 hybrid plans denoted as PII-NART and PIII-NART were generated using the original contours pasted on the PII- and PIII-CT sets by CT-CT fusion. Dosimetric comparisons were made between the NART plans and the corresponding ART plans. In both PII- and PIII-NART plans, the doses to 95% of all the target volumes (D{sub 95}) were increased with better dose uniformity, whereas the organs at risk (OARs) received higher doses compared with the corresponding ART plans. Without replanning, the total dose to 1% of brainstem and spinal cord (D{sub 1}) significantly increased 7.87 {+-} 7.26% and 10.69 {+-} 6.72%, respectively (P = 0.011 and 0.001, respectively), in which 3 patients would have these structures overdosed when compared with those with two replannings. The total maximum doses to the optic chiasm and pituitary gland and the mean doses to the left and right parotid glands were increased by 10.50 {+-} 10.51%, 8.59 {+-} 6.10%, 3.03 {+-} 4.48%, and 2.24 {+-} 3.11%, respectively (P = 0.014, 0.003, 0.053, and 0.046, respectively). The 3-phase radiotherapy protocol showed improved dosimetric results to the critical structures while keeping satisfactory target dose coverage, which demonstrated the advantages of ART in helical tomotherapy of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Small-Molecule Models of Hydrogen-Evolving MX 2 (M = Mo, W; X = S, Se) Bulk Solids: Composition–Activity Relationships

Triangular metal chalcogenide clusters of the form [M 3 Q 7 L 3 ]An (M = Mo or W; Q = S or Se; L = i Bu 2 NCS 2 – , (CF 3 CH 2 ) 2 NCS 2 – , i Bu 2 NCSe 2 – , or i Bu 2 PS 2 – ; An = Cl – or I – ) have been investigated as molecular analogues of layered metal dichalcogenide (MX 2 ) H 2 -evolution catalysts. These clusters have been evaluated for their relative H 2 -evolving ability under a common photolysis protocol implementing [Ru(bpy) 3 ] 2+ as chromophore and Et 3 N as sacrificial electron donor. With M constant as Mo and with constant supporting ligand, clusters with an all-sulfide core enable greater H 2 -TON than clusters with an all-selenide core. A more active catalyst is produced by [Mo 3 S 7 (S 2 CN i Bu 2 ) 3 ] + I – than its W 3 analogue with the same core sulfide composition and supporting dithiocarbamate ligands. Dichalcogenocarbamate ligands provide more active catalysts than dialkyldithiophosphate ligated clusters, and within the dichalcogenocarbamate set, greater H 2 -turnovers correlate with more-electron-donating ligands (i.e., i Bu 2 NCS 2 – > (CF 3 CH 2 ) 2 NCS 2 – > i Bu 2 NCSe 2 – ). Cluster cations with Cl – as counteranion are very similar in activity H 2 -evolving levels to identical clusters with I – , ruling out any significant interfering effect by I – upon the electron transfer relay between Et 3 N and catalyst. In the aggregate, observations are consistent with a mechanism for H 2 evolution that involves reductive extrusion of H 2 from a metal hydride intermediate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Communication Testbed for Testing Power Electronic Agent Systems

Power electronic systems (PES) incorporate complex intra-system communication, which are of vital importance for the successful operation of these systems. This paper proposes and outlines a communication testbed that will help in the development and testing of the communications between the components of PES. It allows for the comparison and evaluation of different communication methods, such as MQTT, Modbus, or User Datagram Protocol (UDP), and for the characterization of how these communication protocols perform.

Dean, Ben↗

SU-E-I-80: Quantification of Respiratory and Cardiac Motion Effect in SPECT Acquisitions Using Anthropomorphic Models: A Monte Carlo Simulation Study

Purpose: The purpose of the present study was to quantify, evaluate the impact of cardiac and respiratory motion on clinical nuclear imaging protocols. Common SPECT and scintigraphic scans are studied using Monte Carlo (MC) simulations, comparing the resulted images with and without motion. Methods: Realistic simulations were executed using the GATE toolkit and the XCAT anthropomorphic phantom as a reference model for human anatomy. Three different radiopharmaceuticals based on 99mTc were studied, namely 99mTc-MDP, 99mTc—N—DBODC and 99mTc—DTPA-aerosol for bone, myocardium and lung scanning respectively. The resolution of the phantom was set to 3.5 mm{sup 3}. The impact of the motion on spatial resolution was quantified using a sphere with 3.5 mm diameter and 10 separate time frames, in the ECAM modeled SPECT scanner. Finally, respiratory motion impact on resolution and imaging of lung lesions was investigated. The MLEM algorithm was used for data reconstruction, while the literature derived biodistributions of the pharmaceuticals were used as activity maps in the simulations. Results: FWHM was extracted for a static and a moving sphere which was ∼23 cm away from the entrance of the SPECT head. The difference in the FWHM was 20% between the two simulations. Profiles in thorax were compared in the case of bone scintigraphy, showing displacement and blurring of the bones when respiratory motion was inserted in the simulation. Large discrepancies were noticed in the case of myocardium imaging when cardiac motion was incorporated during the SPECT acquisition. Finally the borders of the lungs are blurred when respiratory motion is included resulting to a dislocation of ∼2.5 cm. Conclusion: As we move to individualized imaging and therapy procedures, quantitative and qualitative imaging is of high importance in nuclear diagnosis. MC simulations combined with anthropomorphic digital phantoms can provide an accurate tool for applications like motion correction techniques’ optimization. This research has been co-funded by the European Union (European Social Fund) and Greek national resources under the framework of the ‘Archimedes III: Funding of Research Groups in TEI of Athens’ project of the ‘Education & Lifelong Learning’ Operational Programme.

60 APPLIED LIFE SCIENCES↗

SU-E-J-206: Adaptive Radiotherapy for Gynecological Malignancies with MRIGuided Cobolt-60 Radiotherapy

Purpose: Even in the IMRT era, bowel toxicity and bone marrow irradiation remain concerns with pelvic irradiation. We examine the potential gain from an adaptive radiotherapy workflow for post-operative gynecological patients treated to pelvic targets including lymph nodes using MRI-guided Co-60 radiation therapy. Methods: An adaptive workflow was developed with the intent of minimizing time overhead of adaptive planning. A pilot study was performed using retrospectively analyzed images from one patient’s treatment. The patient’s treated plan was created using conventional PTV margins. Adaptive treatment was simulated on the patient’s first three fractions. The daily PTV was created by removing non-target tissue, including bone, muscle and bowel, from the initial PTV based on the daily MRI. The number of beams, beam angles, and optimization parameters were kept constant, and the plan was re-optimized. Normal tissue contours were not adjusted for the re-optimization, but were adjusted for evaluation of plan quality. Plan quality was evaluated based on PTV coverage and normal tissue DVH points per treatment protocol. Bowel was contoured as the entire bowel bag per protocol at our institution. Pelvic bone marrow was contoured per RTOG protocol 1203. Results: For the clinically treated plan, the volume of bowel receiving 45 Gy was 380 cc, 53% of the rectum received 30 Gy, 35% of the bladder received 45 Gy, and 28% of the pelvic bone marrow received 40 Gy. For the adaptive plans, the volume of bowel receiving 45 Gy was 175–201 cc, 55–62% of the rectum received 30 Gy, 21– 27% of the bladder received 45 Gy, and 13–17% of the pelvic bone marrow received 40 Gy. Conclusion: Adaptive planning led to a large reduction of bowel and bone marrow dose in this pilot study. Further study of on-line adaptive techniques for the radiotherapy of pelvic lymph nodes is warranted. Dr. Low is a member of the scientific advisory board of ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

An intercomparison of airborne nitric acid measurements

Results are reported on the performance of (1) denuder-tube/chemiluminescent, (2) nylon-filter/ion-chromatography, and (3) tunable-diode-laser/multipath-absorption HNO3 measurement instruments during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986. The instrument designs, test protocols, and CITE 2 flights are described, and the results are presented in extensive graphs and discussed in detail. The data obtained with the three instruments are shown to be in very poor agreement at mixing ratios below 150 parts per trillion by volume (pptv), with significant discrepancies even at higher levels. Instrument (3) gave systematically higher values than (1) and (2). It is concluded that none of the instruments is accurate enough for reliable use at normal atmospheric HNO3 levels (around 100 pptv).

Gregory, G. L.↗

An investigation of networking techniques for the ASRM facility

This report is based on the early design concepts for a communications network for the Advanced Solid Rocket Motor (ASRM) facility being built at Yellow Creek near Iuka, MS. The investigators have participated in the early design concepts and in the evaluation of the initial concepts. The continuing system design effort and any modification of the plan will require a careful evaluation of the required bandwidth of the network, the capabilities of the protocol, and the requirements of the controllers and computers on the network. The overall network, which is heterogeneous in protocol and bandwidth, is being modeled, analyzed, simulated, and tested to obtain some degree of confidence in its performance capabilities and in its performance under nominal and heavy loads. The results of the proposed work should have an impact on the design and operation of the ASRM facility.

Moorhead, Robert J., II↗

The crystallization and crystalline properties of LARC-TPI

LARC-TPI, a thermoplastic polyimide, has been studied in order to develop an understanding of its crystalline phase transition. Our experiments suggest that samples synthesized in different laboratories apparently had different degrees of imidization and their thermal behaviors differed accordingly. When the most crystalline of these polyimides was studied in some detail, we found that it melted irreversibly in that once a sample was completely melted it would not recrystallize. A polymer that did not recrystallize displayed a glass transition, which increased in temperature upon subsequent cooling and reheating. Solubility experiments indicated that heating above the crystalline melting temperature led to network formation in the polymer, a conclusion that is consistent with other behavior just mentioned. Differential calorimetric studies revealed that annealing at slow heating rates or under isothermal conditions resulted in dual melting transitions. These studies, supported by X-ray diffraction results, strongly indicate that the annealing process involves a solid-liquid-solid transformation. From an existing phenomenological model for the kinetics of phase transitions, kinetic parameters for these crystallizations have been evaluated. The Avrami exponents n increased with the annealing temperature in the protocol used in this study. Their values were about 2 or lower, thus indicating that crystallization may have followed a mechanism that included heterogeneous nucleation of a low dimensional order in which all the embryonic crystallites formed at the beginning of the process. A positive temperature coefficient for these crystallizations indicated that diffusion may have had a rate controlling influence and affected the values of n.

Theil, Michael H.↗

SeaWIFS Postlaunch Technical Report Series: The SeaWiFS Photometer Revision for Incident Surface Measurement (SeaPRISM) Field Commissioning - Volume 13

This report documents the scientific activities that took place at the Acqua Alta Oceanographic Tower (AAOT) in the northern Adriatic Sea off the coast of Italy from 2-6 August 1999. The ultimate objective of the field campaign was to evaluate the capabilities of a new instrument called the SeaWiFS Photometer Revision for Incident Surface Measurements (SeaPRISM). SeaPRISM is based on a CE-318 sun photometer made by CIMEL Electronique (Paris, France). The CE-318 is an automated, robotic system which measures the direct sun irradiance plus the sky radiance in the sun plane and in the almucantar plane. The data are transmitted over a satellite link, and this remote operation capability has made the device very useful for atmospheric measurements. The revision to the CE-318 that makes the instrument potentially useful for SeaWiFS calibration and validation activities is to include a capability for measuring the radiance leaving the sea surface in wavelengths suitable for the determination of chlorophyll a concentration. The initial evaluation of this new capability involved above- and in-water measurement protocols. An intercomparison of the water-leaving radiances derived from SeaPRISM and an in-water system showed the overall spectral agreement was approximately 8.6%, but the blue-green channels intercompared at the 5% level. A blue-green band ratio comparison was at the 4% level.

Hooker, Stanford B.↗

Dietary Intake Can Predict and Protect Against Changes in Bone Metabolism during Spaceflight and Recovery (Pro K)

Bone loss is not only a well-documented effect of spaceflight on astronauts, but also a condition that affects millions of men and women on Earth each year. Many countermeasures aimed at preventing bone loss during spaceflight have been proposed, and many have been evaluated to some degree. To date, those showing potential have focused on either exercise or pharmacological interventions, but none have targeted dietary intake alone as a factor to predict or minimize bone loss during spaceflight. The "Dietary Intake Can Predict and Protect against Changes in Bone Metabolism during Spaceflight and Recovery" investigation ("Pro K") is one of the first inflight evaluations of a dietary countermeasure to lessen bone loss of astronauts. This protocol will test the hypothesis that the ratio of acid precursors to base precursors (specifically animal protein to potassium) in the diet can predict directional changes in bone mineral during spaceflight and recovery. The ratio of animal protein to potassium in the diet will be controlled for multiple short (4-day) periods before and during flight. Based on multiple sets of bed rest data, we hypothesize that a higher ratio of the intake of animal protein to the intake of potassium will yield higher concentrations of markers of bone resorption and urinary calcium excretion during flight and during recovery from bone mineral loss after long-duration spaceflight.

Smith, Scott M.↗

Note: Elastic wave velocity measurement using ultrasonic system with two-reflectors

We show an experiment protocol for ultrasonic velocity measurements carried out in a synchrotron-based multi-anvil high-pressure apparatus. By adding a second reflector in the cell assembly, ultrasonic signals are significantly stabilized for experiments where samples experience structural changes such as phase transition or partial melting. Features of the elastic wave can be calculated from acoustic impedance allowing us to evaluate the possible interference between the sample reflection and other internal multiple reflections. This new protocol allows various forms of samples including cold-pressed powder samples, for which grain size and porosity can be monitored and controlled in situ during the annealing process.

47 OTHER INSTRUMENTATION↗

Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner

Purpose: The highest photon fluence rate that a computed tomography (CT) detector must be able to measure is an important parameter. The authors calculate the maximum transmitted fluence rate in a commercial CT scanner as a function of patient size for standard head, chest, and abdomen protocols. Methods: The authors scanned an anthropomorphic phantom (Kyoto Kagaku PBU-60) with the reference CT protocols provided by AAPM on a GE LightSpeed VCT scanner and noted the tube current applied with the tube current modulation (TCM) system. By rescaling this tube current using published measurements on the tube current modulation of a GE scanner [N. Keat, “CT scanner automatic exposure control systems,” MHRA Evaluation Report 05016, ImPACT, London, UK, 2005], the authors could estimate the tube current that these protocols would have resulted in for other patient sizes. An ECG gated chest protocol was also simulated. Using measured dose rate profiles along the bowtie filters, the authors simulated imaging of anonymized patient images with a range of sizes on a GE VCT scanner and calculated the maximum transmitted fluence rate. In addition, the 99th and the 95th percentiles of the transmitted fluence rate distribution behind the patient are calculated and the effect of omitting projection lines passing just below the skin line is investigated. Results: The highest transmitted fluence rates on the detector for the AAPM reference protocols with centered patients are found for head images and for intermediate-sized chest images, both with a maximum of 3.4 ⋅ 10{sup 8} mm{sup −2} s{sup −1}, at 949 mm distance from the source. Miscentering the head by 50 mm downward increases the maximum transmitted fluence rate to 5.7 ⋅ 10{sup 8} mm{sup −2} s{sup −1}. The ECG gated chest protocol gives fluence rates up to 2.3 ⋅ 10{sup 8} − 3.6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} depending on miscentering. Conclusions: The fluence rate on a CT detector reaches 3 ⋅ 10{sup 8} − 6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} in standard imaging protocols, with the highest rates occurring for ECG gated chest and miscentered head scans. These results will be useful to developers of CT detectors, in particular photon counting detectors.

60 APPLIED LIFE SCIENCES↗