Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Recanalization and Mortality Rates of Thrombectomy With Stent-Retrievers in Octogenarian Patients with Acute Ischemic Stroke

BackgroundOur objective was to evaluate the effect of treatment with stent-retrievers in octogenarians suffering an acute ischemic stroke.MethodsA total of 150 consecutive patients with acute stroke who were treated with stent-retrievers between April 2010 and June 2012 were retrospectively reviewed. Patients were divided into those <80 years old (n = 116) and those ≥80 (n = 34). Baseline characteristics, procedure data, and endpoints (postprocedural NIHSS, death, and mRS at 3 months) were compared.ResultsHigh blood pressure, atrial fibrillation, and anticoagulation were more frequent in octogenarians (p = 0.01, 0.003, and 0.04 respectively). There were no differences between both groups regarding previous intravenous thrombolysis (32.4 vs. 48.3 %, p = 0.1), preprocedural NIHSS (18.1 vs. 16.8, p = 0.3), procedure time (74.5 (40–114) min vs. 63 (38–92) min, p = 0.2), revascularization time (380.5 (298–526.3) min vs. 350 (296.3–452.8), p = 0.3), TICI ≥ 2B (88.2 vs. 93.9 %, p = 0.1), and symptomatic haemorrhage (5.9 vs. 2.6 %, p = 0.3). Discharge NIHSS was higher in octogenarians (9.7 vs. 6.5, p = 0.03). Death and 3-month mRS ≥3 were more frequent in octogenarians (35.3 vs. 17.2 %, p = 0.02 and 73.5 vs. 37.1 %, p = 0.02). ICA-involvement and prolonged revascularization involved higher mortality (66.7 vs. 27.6 %, p = 0.03) and worse mRS (50 vs. 24.4 %, p = 0.06) in octogenarians.ConclusionsIn our series, treatment with stent-retrievers in octogenarians with acute ischemic stroke achieved good rates of recanalization but with a high mortality rate. ICA involvement and revascularization times beyond 6 hours associated to a worse prognosis. These data might be of value in the design of prospective studies evaluating the clinical efficacy of the endovascular treatments in octogenarians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutronic Design and Analysis of the Holos-Quad Concept

HolosGen, LLC is proposing a highly innovative micro-reactor concept targeting both civilian and military applications. It consists of an advanced helium-cooled gas reactor using a turbojet-type turbine and compressor to achieve a highly condensed reactor that fits into a commercial ISO container. The Holos-Quad concept being considered for civilian applications will generate 22MWt, using four Subcritical Power Modules (SPMs) that fit into one 40-foot ISO container. It is a high-temperature gas-cooled reactor concept using TRISO fuel distributed in graphite hexagonal blocks, cooled with helium gas at 7MPa and a high outlet temperature. In FY2019, HolosGen, LLC received an ARPA-E MEITNER grant to team up with the Argonne National Laboratory (ANL) design team to demonstrate the feasibility of the Holos-Quad concept in terms of neutronics. In particular, the evaluation study of the Holos design features and alternative options for reactivity control was considered. Through these tasks, the ANL design team has been working on demonstrating the feasibility of the Holos-Quad concept in terms of neutronics to help advance the core design of the Holos-Quad. A rigorous design approach was employed for the Holos-Quad in order to ensure that the input space is fully investigated, and that the best solutions are considered. The first step of this approach consisted of properly defining the Holos-Quad design problem by identifying the competitive design objectives: its economic performance is maximized with longer lifetime and its transportability to remote locations is maximized with reduced weight. The design problem also required to identify the operational constraints (in terms of thermal hydraulics, reactivity feedback and shutdown margins) and the input parameters that could be varied. In the second step, a sensitivity analysis was performed to enable preliminary investigation of the input space to identify the correlations among input and output variables. It allowed, for instance, to find input parameters that have relatively poor impact on the core performance and that could be removed from the optimization problem to accelerate its convergence. This sensitivity analysis showed that the design problem defined is highly constrained since only 117 solutions out of 1,000 simulated cores met all the design constraints. The design optimization was performed in the third step employing a genetic algorithm to effectively explore this highly constrained input space and find global optimal solutions. More than 2,500 cores were fully evaluated to converge to a Pareto Frontier of optimum solutions providing best compromise between the life-time target and the total core weight, as shown in Figure 1. The main benefit of this approach was to reduce the human effort and to be able to automatically re-run the optimization problem when changing the design problem. The multi-objective optimization identified various core solutions that would be optimum solutions for different types of applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving dairy manure hydrolysis and acidification through microbial community restructuring by adaptation to hyperthermophilic conditions

Dairy manure (DM) contributes significantly to greenhouse gas emissions and ecosystem degradation, yet its resistance to biodegradation hinders widespread bioprocessing applications. Lignocellulosic materials in DM pose a particular challenge because of their recalcitrance. Bioprocessing under hyperthermophilic (≥70 °C) conditions potentially offers an advantage over traditional fermentation temperatures due to enhanced activity of enzymes and the kinetics of enzymatic reactions. This can lead to a higher conversion rate and a greater extent of biomass hydrolysis and acidification. To test the validity of this hypothesis, the current study evaluated the efficacy of anaerobic hydrolysis and acidogenic fermentation of DM under mesophilic, thermophilic, and hyperthermophilic conditions. All inocula were adapted to corresponding temperatures but were derived from the same mesophilic source. Hyperthermophilic conditions resulted in superior DM hydrolysis efficiency (53%) compared to mesophilic (34%) and thermophilic (42%) conditions. The hyperthermophilic environment was particularly favorable to the decomposition of crude proteins and hemicellulose, which were reduced by 64% and 54%, respectively. Furthermore, hyperthermophilic fermentation also yielded the highest volatile fatty acid (VFA) production rate of 460 mg/L/day during the first four days, representing improvements of 50% and 90% over mesophilic and thermophilic conditions. In part, this was attributed to the enhanced production of branched-chain VFAs, including an increase of 6–10% in isobutyric acid and 12–13% in isovaleric acid. At hyperthermophilic conditions, however, there was no accumulation of VFAs during the days 5–8 of fermentation, which could be due to acetate conversion by the syntrophic acetate-oxidizing bacteria. A considerable gain in hydrolysis efficiency and VFA production rate were accompanied by a reduction in microbial diversity, which suggests that hyperthermophilic temperature is a favorable environment for the selection of organisms with enhanced DM hydrolysis and fermentation capabilities. A significantly increased relative abundance of xylanolytic Caldicoprobacter (23% of population) and proteolytic Thermovirga (9% of population) could be the major contributors to improved decomposition of hemicellulose and protein. As revealed by the techno-economic analysis, acidogenic fermentation of DM at 70 °C and a retention period of 4 days provides the greatest positive net present value, highest internal rate of return of 9.2%, and shortest investment payback period of 9 years. Furthermore, this study demonstrates that hyperthermophilic conditions enable superior deconstruction and bioconversion of lignocellulose-containing biomass into VFAs under reduced retention times, offering a promising approach for improving DM management and generating bioproducts.

09 BIOMASS FUELS↗

Noncovalent Interaction Energies in Covalent Complexes: TEM-1 beta-Lactamase and beta-Lactams

The class A {beta}-lactamase TEM-1 is a key bacterial resistance enzyme against {beta}-lactam antibiotics, but little is known about the energetic bases for complementarity between TEM-1 and its inhibitors. Most inhibitors form a covalent adduct with the catalytic Ser70, making the measurement of equilibriumconstants, and hence interaction energies, technically difficult. This study evaluates noncovalent interactions withincovalent complexes by examining the differential stability of TEM-1 and its inhibitor adducts. The thermal denaturation of TEM-1 follows a two-state, reversible model with a melting temperature (T{sub m}) of 51.6 C and a van't Hoff enthalpy of unfolding ({Delta}H{sub VH}) of 146.2 kcal/mol at pH 7.0. The stability of the enzyme changes on forming an inhibitor adduct. As expected, some inhibitors stabilize TEM-1; transition-state analogues increase the T{sub m} by up to 3.7 C(1.7 kcal/mol). Surprisingly, all {beta}-lactam covalent acyl-enzyme complexes tested destabilize TEM-1 significantly relative to the apoenzyme. For instance, the clinically used inhibitor clavulanic acid and the {beta}-lactamase-resistant {beta}-lactams moxalactam and imipenem destabilize TEM-1 by over 2.6 C (1.2 kcal/mol) in their covalent adducts. Based on the structure of the TEM-1/imipenem complex (Maveyraud et al., J Am Chem Soc 1998;120:9748-52), destabilization by moxalactam and imipenem is thought to be caused by a steric clash between the side-chain of Asn132 and the 6(7)-{alpha} group of these {beta}-lactams. To test this hypothesis, the mutant enzyme N132A was made. In contrast with wild-type, the covalent complexes between N132A and both imipenem and moxalactam stabilize the enzyme, consistent with the hypothesis. To investigate the structural bases of this dramatic change instability, the structure of N132A/imipenem was determined by X-ray crystallography. In the complex with N132A, imipenemadopts a very different conformation from that observed in the wild-type complex, and the putative destabilizing interaction with residue 132 is relieved. Studies of several enzymes suggest that {beta}-lactams, andcovalent inhibitors in general, can have either net favorable or net unfavorable noncovalent interaction energies within the covalent complex. In the case of TEM-1, such unfavorable interactions convert substrate analogues into very effective inhibitors.

60 APPLIED LIFE SCIENCES↗

Destructive PIE and Safety Testing of Six AGR-5/6/7 Capsule 2 Compacts

This study evaluates fission product retention and particle failure mechanisms in AGR-5/6/7 Capsule 2 uranium carbide and uranium oxide (UCO) tristructural isotropic (TRISO) fuel under high-temperature gas reactor accident-relevant conditions using high-temperature safety tests and destructive postirradiation examination. Three Capsule 2 compacts were held isothermally at 1600°C for approximately 300 hours and one compact at 1800°C for approximately 300 hours; two additional compacts were examined in the as-irradiated state. Post-test deconsolidation–leach–burn–leach (DLBL) quantified nuclide inventories in matrix and particles. Individual particles were surveyed for radioisotope inventories, and microanalytical approaches resolved microstructural evolution and fission product distributions within the coating layers. At 1600°C, no krypton was detected above the minimum detectable limit, and cesium releases were far below a single particle equivalent, indicating the absence of full TRISO failure or SiC failures. Silver releases were limited and primarily reflected depleted postirradiation inventories, consistent with prior compact-level exams indicating substantial in-pile 110mAg loss. At 1800°C, cumulative 134Cs release of approximately 2.5 particle equivalents and delayed 85Kr totaling approximately 0.53 particle equivalents were consistent with one full TRISO failure and two SiC failures. Europium and strontium releases were roughly one order of magnitude higher than at 1600°C and comparable to AGR-1/AGR-2 high-temperature tests, with sustained late-hold rates indicating diffusion through intact coatings coupled with matrix depletion. Overall, AGR-5/6/7 Capsule 2 UCO fuel demonstrated fission product retention during safety testing consistent with prior AGR campaigns, while distinctive in-pile 110mAg depletion and measurable 1600°C europium loss motivate targeted follow-on studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-T-254: Dose Volume Histogram (DVH) Analysis of Breath Hold Vs Free Breathing Techniques for Esophageal Tumors

Purpose: Lung and heart doses and associated toxicity are of concern in radiotherapy for esophageal cancer. This study evaluates the dosimetry of deep-inspiration-breath-hold (DIBH) technique as compared to freebreathing( FB) using 3D-conformal treatment(3D-CRT) of esophageal cancer. Methods: Eight patients were planned with FB and DIBH CT scans. DIBH scans were acquired using Varian RPM system. FB and DIBH CTs were contoured per RTOG-1010 to create the planning target volume(PTV) as well as organs at risk volumes(OAR). Two sets of gross target volumes(GTV) with 5cm length were contoured for each patient: proximal at the level of the carina and distal at the level of gastroesophageal junction and were enlarged with appropriate margin to generate Clinical Target Volume and PTV. 3D-CRT plans were created on Eclipse planning system for 45Gy to cover 95% of PTV in 25 fractions for both proximal and distal tumors on FB and DIBH scans. For distal tumors celiac nodes were covered electively. DVH parameters for lung and heart OARs were generated and analyzed. Results: All DIBH DVH parameters were normalized to FB plan values. Average of heart-mean and heart-V40 was 0.70 and 0.66 for proximal lesions. For distal lesions ratios were 1.21 and 2.22 respectively. For DIBH total lung volume increased by 2.43 times versus FB scan. Average of lung-mean, V30, V20, V10, V5 are 0.82, 0.92, 0.76, 0.77 and 0.79 for proximal lesions and 1.17,0.66,0.87,0.93 and 1.03 for distal lesions. Heart doses were lower for breath-hold proximal lesions but higher for distal lesions as compared to free-breathing plans. Lung doses were lower for both proximal and distal breath-hold lesions except mean lung dose and V5 for distal lesions. Conclusion: This study showed improvement of OAR doses for esophageal lesions at mid-thoracic level utilizing DIBH vs FB technique but did not show consistent OAR sparing with DIBH for distal lesions.

60 APPLIED LIFE SCIENCES↗

Destructive PIE and Safety Testing of Six AGR-5/6/7 Capsule 2 Compacts

This study evaluates fission product retention and particle failure mechanisms in AGR-5/6/7 Capsule 2 uranium carbide and uranium oxide (UCO) tristructural isotropic (TRISO) fuel under high-temperature gas reactor accident-relevant conditions using high-temperature safety tests and destructive post-irradiation examination. Three Capsule 2 compacts were held isothermally at 1600°C for approximately 300 hours and one compact at 1800°C for approximately 300 hours; two additional compacts were examined in the as-irradiated state. Post-test deconsolidation–leach–burn–leach (DLBL) quantified nuclide inventories in matrix and particles. Individual particles were surveyed for radioisotope inventories, and microanalytical approaches resolved microstructural evolution and fission product distributions within the coating layers. At 1600°C, no krypton was detected above the minimum detectable limit, and cesium releases were far below a single particle equivalent, indicating the absence of full TRISO failure or SiC failures. Silver releases were limited and primarily reflected depleted post-irradiation inventories, consistent with prior compact-level exams indicating substantial in-pile 110m Ag loss. At 1800°C, cumulative 134 Cs release of approximately 2.5 particle equivalents and delayed 85 Kr totaling approximately 0.53 particle equivalents were consistent with one full TRISO failure and two SiC failures. Europium and strontium releases were roughly one order of magnitude higher than at 1600°C and comparable to AGR-1/AGR-2 high-temperature tests, with sustained late-hold rates indicating diffusion through intact coatings coupled with matrix depletion. Overall, AGR-5/6/7 Capsule 2 UCO fuel demonstrated fission product retention during safety testing consistent with prior AGR campaigns, while distinctive in-pile 110m Ag depletion and measurable 1600°C europium loss motivate targeted follow-on studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing methods in fusion and fitting for time series construction in remote sensing-based earth observations

This study evaluates the comparative performance of spatiotemporal fusion and time-series fitting methods for constructing high-spatiotemporal-resolution remote sensing time-series data. Due to in-class similarity of fusion methods and fitting methods, we employ the Fit-FC (Fitting, spatial Filtering, and residual Compensation) model as a representative fusion method and the linear harmonic fitting model as a representative fitting method. Both Fit-FC and the linear harmonic fitting are widely used for high-spatiotemporal-resolution time-series data construction, and we modify the original Fit-FC model to enable automatic time-series fusion. To ensure data representativeness, we use 3 years (2019–2021) of Harmonized Landsat and Sentinel-2 surface reflectance datasets and Terra MCD43A4 products. Eight experimental regions are selected worldwide to guarantee generalization of the comparative performance between fusion and fitting methods, covering diverse land-use types (cropland, developed land, forest, and grassland) and varying climatological conditions. Time-series of NDVI and surface reflectance are analyzed under both actual observations and simulated data-missing scenarios. The constructed time-series data reveals that (1) the modified Fit-FC and linear harmonic fitting model achieve excellent performance in constructing high-resolution time-series images; (2) the fusion method outperforms the fitting method in constructing time-series of NDVI and surface reflectance images in cropland-, forest-, and grassland-dominated regions; (3) both methods achieve comparable performance in developed-dominated regions; (4) the fusion method is more robust to missing data, and better captures abrupt phenological transitions under conditions of continuous missing data; (5) the fitting method is computationally more efficient, making it suitable for large-scale time-series image reconstruction. This study provides valuable insights for selecting optimal strategies to generate high-resolution time-series images across diverse application scenarios and lays a foundation for extensions to other vegetation indices or land surface variables.

54 ENVIRONMENTAL SCIENCES↗

The Randomized Freeway Stent Study: Drug-Eluting Balloons Outperform Standard Balloon Angioplasty for Postdilatation of Nitinol Stents in the SFA and PI Segment

Purpose: The prospective randomized multicenter Freeway study evaluated the possible hemodynamic and clinical benefits of primary stent insertion followed by percutaneous transluminal angioplasty (PTA) with drug-eluting balloons (DEB) over post-stent insertion PTA with standard balloons in the treatment of symptomatic femoropopliteal arteriosclerotic lesions. Methods: In total, 204 patients in 13 centers in Germany and Austria were enrolled and randomized to primary stenting followed by either FREEWAY™ drug-eluting balloon or standard PTA balloon angioplasty. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 6 months; the secondary endpoints include TLR rate at 12 months and primary patency, shift in Rutherford classification, ankle–brachial index (ABI) and major adverse events (MAE) at 6 and 12 months. Lesion characteristics and vessel patency were analyzed by an independent and blinded corelab. Results: At 6-month and 12-month follow-up, TLR rate was lower in the DEB arm compared to standard PTA but did not reach statistical significance (4.1% vs. 9.0% p = 0.234 and 7.9% vs. 17.7% p = 0.064, respectively). Primary patency was significantly better for patients treated with the DEB at 6 months (90.3% vs. 69.8% p = 0.001) and 12 months (77.4% vs. 61.0% p = 0.027). Improvement in Rutherford classifications was likewise significantly better for patients in the DEB group at 6 (94.9% vs. 84.3% p = 0.027) and 12 months (95.5% vs. 79.9% p = 0.003). The percentage of patients with an improved ABI of 1.0–1.2 was significantly higher in the DEB group compared to the PTA group at 6 months (55.3% vs. 35.3%; p = 0.015) but without significant difference at 12 months (48.2% vs. 32.9%; p = 0.055). At 6 months, rate of major adverse events (MAE) was 1% in both arms, and at 12 months 2.2% for the DEB and 3.8% for the PTA group. Conclusion: The Freeway Stent Study shows that the usage of DEB as a restenosis prophylaxis seems to be safe and feasible. The 12-month follow-up results give a clear sign in favor of the DEB group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined effects of warming and acidification on accumulation and elimination dynamics of paralytic shellfish toxins in mussels Mytilus galloprovincialis

Highlights: • Impact of warming and acidification on the accumulation/elimination dynamics of HAB-toxins in shellfish. • High toxicity levels were found under current conditions. • Climate change scenarios may lead to lower but prolonged PST contamination. Harmful algal blooms (HAB) have been increasing in frequency and intensity most likely due to changes on global conditions, which constitute a significant threat to wild shellfish and its commercial farming. This study evaluated the impact of increasing seawater temperature and acidification on the accumulation/elimination dynamics of HAB-toxins in shellfish. Mytilus galloprovincialis were acclimated to four environmental conditions simulating different climate change scenarios: i) current conditions, ii) warming, iii) acidification and iv) interaction of warming with acidification. Once acclimated, mussels were exposed to the paralytic shellfish toxins (PSTs) producing dinoflagellate Gymnodinium catenatum for 5 days and to non-toxic diet during the subsequent 10 days. High toxicity levels (1493 µg STX eq. kg{sup −1}) exceeding the safety limits were determined under current conditions at the end of the uptake period. Significantly lower PSP toxicity levels were registered for warming- and acidification-acclimated mussels (661 and 761 µg STX eq. kg{sup −1}). The combined effect of both warming and acidification resulted in PSP toxicity values slightly higher (856 μg STX eq. kg{sup −1}). A rapid decrease of toxicity was observed in mussels at the current conditions after shifting to a non-toxic diet, which was not noticed under the predicted climate change scenarios. Variability of each PST analogue, measured throughout the experiment, highlighted different mechanisms are associated with changes of each environmental factor, although both resulting in lower toxicity. Warming-acclimated mussels showed lower accumulation/elimination rates, while acidification-acclimated mussels showed higher capability to accumulate toxins, but also a higher elimination rate preventing high toxicity levels. As different mechanisms are triggered by warming and acidification, their combined effect not leads to a synergism of their individual effects. The present work is the first assessing the combined effect of climate change drivers on accumulation/elimination of PSTs, in mussels, indicating that warming and acidification may lead to lower toxicity values but longer toxic episodes. PSTs are responsible for the food poisoning syndrome, paralytic shellfish poisoning (PSP) in humans. This study can be considered as the first step to build models for predicting shellfish toxicity under climate change scenarios.

54 ENVIRONMENTAL SCIENCES↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

14 SOLAR ENERGY↗

Mercury removal from flue gases by novel regenerable magnetic nanocomposite sorbents

Magnetic zeolite composites with supported silver nanoparticles are a new class of multifunctional materials with potential applications as recyclable catalysts, disinfectants, and sorbents. This study evaluated the suitability of the magnetic composites as sorbents for the removal of elemental mercury vapor from flue gases of coal-fired power plants. The sorbents were found to completely capture mercury at temperatures up to 200{sup o}C, and the mercury capacity of the sorbents was found to be affected by the state, content, and size of the silver particles in the composite. Cumulative or extended thermal treatments at 400{sup o}C were found to improve the mercury capture capacity, allowing the sorbent to be regenerated and recycled multiple times without performance degradation. The magnetic sorbent was readily separated from fly ash by magnetic separation, leaving the fly ash essentially free of sorbent contamination. In initial in-plant tests, the sorbents were able to capture mercury from the flue gases of an operational, full-scale, coal-fired power plant. The combination of mercury capacity, ease of separation and regeneration, and recyclability makes these multifunctional magnetic composites excellent candidate sorbents for the control of mercury emissions from coal-fired power plants. 35 refs., 5 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implications of Changes in Water Stress and Precipitation Extremes for Cocoa Production in Côte D'ivoire and Ghana

ABSTRACT Climate change induces high variability in drought patterns and extreme precipitation indices in rainfed cocoa farming, impacting cocoa production. This study evaluated water stress, meteorological and agricultural drought conditions, and critical extreme precipitation indices in the world's two largest cocoa‐producing nations from 1981 to 2022. The results revealed a significant reduction in total annual precipitation (PRCPTOT), in the last three decades, with the greatest decline in the 1991–2000 and 2011–2022 periods. Ghana experienced the most significant reduction up to 15% (200 mm/year) in the last decade, attributed to a substantial decrease in wet days number (RR1) up to 25 days per year, a reduction in maximum consecutive wet days (CWD) up to 6 days per year, and an increase in maximum consecutive dry days (CDD) up to 15 days per year. Moreover, there was a notable decline in the Simple Daily Intensity Index (SDII), with reductions of up to 4 mm/day in certain areas, contributing to increased drought frequency, severity, and duration. In the most recent decade (2011–2022), particularly during the extremely dry years of 2013 and 2015, cocoa‐growing regions in Ghana (GHA) and eastern Côte d'Ivoire (CIV) experienced prolonged agricultural drought expressed by soil moisture deficit, typically extending from May to September. Additionally, large portions of central and eastern Ghana, as well as northeastern Côte d'Ivoire experienced sustained water stress, with over three consecutive months of total monthly precipitation falling below 100 mm, negatively impacting cocoa productivity. The decrease in the yield in the range of 2.5% to 37% was noted in the dry years and the following years, varying according to the country depending on the severity of the drought. Sensitivity analysis highlights cocoa yield's responsiveness to drought and water stress, particularly in specific years when water stress occurred, such as 1984,1985, 1989, 1995, 1999, 2000, and 2008. Considering the observed trends in precipitation patterns and their impact on cocoa production, it is crucial to acknowledge the inherent uncertainty of future precipitation patterns due to climate change. To address this challenge effectively, our study underscores the importance of identifying and closely monitoring regions currently facing water stress, as determined by precipitation and drought indicators. Over the analysed period (1981–2022), we have noted shifts in the distribution of water‐stressed areas, highlighting the dynamic nature of this issue. Consequently, we advocate for a targeted approach to implement cocoa supplementary irrigation in consistently water‐stressed regions.

Obahoundje, Salomon [International Water Managemen↗

Reactor Performance and Safety Characteristics of Beryllium-Based Composite Moderators as Replacements for Graphite in mHTGRs

Here, this study evaluates beryllium-based two-phase composite moderators as an alternative to graphite in an evaluation of reactor performance and safety characteristics. Historically, modular high-temperature gas-cooled reactors (mHTGRs) use graphite as a moderator because of its high moderating ratio and reasonable thermal properties; however, graphite has unfavorable properties under irradiation, which can require component replacement and a significant radioactive waste burden. In this assessment, we explore advanced moderators comprised of magnesium oxide (MgO) as the host matrix and beryllium metal and/or beryllium oxide (Be and/or BeO) as the entrained moderating phase. For the reactor performance and thermal-hydraulic safety analysis, the core design model of the General Atomics mHTGR-350 was used to demonstrate the feasibility of a “drop-in” replacement of graphite using the beryllium-based moderators. We employed the neutronics code Serpent to analyze the moderating behavior of the composite moderators with comparisons drawn to graphite. We performed a scoping analysis of accidents for mHTGRs using RELAP to show that these moderators do not present impediments to safety and are expected to stay within temperature limits. Measured thermophysical properties of the composite moderators are used in the thermal-hydraulic assessments. Our analysis reveals that the two-phase composite MgO-matrix beryllium-based moderators are a suitable replacement for graphite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Pronghorn for Natural-Circulation Molten Salt Loops

This paper presents the development and validation of a high-fidelity thermal-hydraulic model of a molten salt natural circulation flow loop, designed for integration within a digital twin framework. The study evaluates the performance of Idaho National Laboratory’s Pronghorn against experimental data from Texas A&M University Molten Salt Flow Loop (MSFL) four Hitec-salt test benchmark data. Natural circulation of high-Prandtl-number fluids exhibits complex, counter-intuitive flow patterns that make pointwise thermocouple readings unreliable. Experimental work at TAMU’s MSFL provides benchmark data, including flow visualization at a test-section and centerline steady-state temperature measurements along the loop. Validation includes four single-phase natural circulation test cases with Hitec salt. Key metrics include flow profile agreement and steady-state temperature accuracy. Pronghorn results for two-dimensional single-phase agree qualitatively with the experimental flow profile. This paper illustrates the importance of Computational Fluid Dynamics (CFD) in elucidating the behavior of high-Prandtl-number thermal-hydraulics, along with how misleading centerline temperature measurements can be. Pronghorn reproduces the axial and radial stratification that makes single thermocouple readings unreliable. Future research will focus on reduced-order modeling techniques to enable rapid simulation suitable for real-time digital twin applications. The validated cases provide a basis for developing reduced-order surrogates aimed at real-time digital-twin applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Fusion-fission hybrid for fissile fuel production without processing

Two scenarios are typically envisioned for thorium fuel cycles: “open” cycles based on irradiation of 232 Th and fission of 233 U in situ without reprocessing or “closed” cycles based on irradiation of 232 Th followed by reprocessing, and recycling of 233 U either in situ or in critical fission reactors. This study evaluates a third option based on the possibility of breeding fissile material in a fusion-fission hybrid reactor and burning the same fuel in a critical reactor without any reprocessing or reconditioning. This fuel cycle requires the hybrid and the critical reactor to use the same fuel form. TRISO particles embedded in carbon pebbles were selected as the preferred form of fuel and an inertial laser fusion system featuring a subcritical blanket was combined with critical pebble bed reactors, either gas-cooled or liquid-salt-cooled. The hybrid reactor was modeled based on the earlier, hybrid version of the LLNL Laser Inertial Fusion Energy (LIFE) system, whereas the critical reactors were modeled according to the Pebble Bed Modular Reactor (PBMR) and the Pebble Bed Advanced High Temperature Reactor (PB-AHTR) design. An extensive neutronic analysis was carried out for both the hybrid and the fission reactors in order to track the fuel composition at each stage of the fuel cycle and ultimately determine the plant support ratio, which has been defined as the ratio between the thermal power generated in fission reactors and the fusion power required to breed the fissile fuel burnt in these fission reactors. It was found that the maximum attainable plant support ratio for a thorium fuel cycle that employs neither enrichment nor reprocessing is about 2. This requires tuning the neutron energy towards high energy for breeding and towards thermal energy for burning. A high fuel loading in the pebbles allows a faster spectrum in the hybrid blanket; mixing dummy carbon pebbles with fuel pebbles enables a softer spectrum in the critical reactors. This combination consumes about 20% of the thorium initially loaded in the hybrid reactor (~200 GWd/tHM), partially during hybrid operation, but mostly during operation in the critical reactor. The plant support ratio is low compared to the one attainable using continuous fuel chemical reprocessing, which can yield a plant support ratio of about 20, but the resulting fuel cycle offers better proliferation resistance as fissile material is never separated from the other fuel components.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗