Parametric Channeling Radiation and its Application to the Measurement of Electron Beam Energy

We have proposed a method for observing parametric channeling radiation (PCR) and of applying it to the measurement of electron beam energy. The PCR process occurs if the energy of the channeling radiation coincides with the energy of the parametric X-ray radiation (PXR). The PCR process can be regarded as the diffraction of 'virtual channeling radiation'. We developed a scheme for beam energy measurement and designed an experimental setup. We also estimated the beam parameters, and calculated the angular distributions of PXR and PCR. These considerations indicate that the observation of PCR is promising.

43 PARTICLE ACCELERATORS↗

Status of the SAGA Light Source

The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installed in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.

43 PARTICLE ACCELERATORS↗

The Nanofocus Endstation of the MINAXS Beamline of PETRA III

The Micro- and Nanofocus X-ray Scattering Beamline (MINAXS) of the new 3rd generation source PETRA III is equipped with two endstations, out of which the farthest from the high beta undulator source is designed to provide a high flux, monochromatic X-ray beam focused to a size in the order of 100 nmx100 nm routinely used for microdiffraction experiments (nanofocus endstation). This contribution presents an overview on the current status of the nanofocus endstation and outlines the to-be-used experimental setup.

43 PARTICLE ACCELERATORS↗

Opportunities for the Crystal Ball detector at JLab

We discuss the physics case for a new experimental setup that consists of the Crystal Ball multiphoton spectrometer and the CLAS12 forward detector installed at the tagged photon beam of Hall-B at JLab. The proposed apparatus will provide nearly 4{pi} sr coverage and good energy and angular resolution for photons and protons allowing a detailed high statistics investigation of the reactions with multiple photons. Such setup can be used to investigate the spectrum of doubly-strange {Xi} via their neutral decays, test C, CP, and T invariance in the neutral and charged decays of {eta} and {eta}' perform precise measurements of the Dalitz and double Dalitz decays of pseudoscaler and vector mesons, etc. Such data may also shed new light on the existence and the properties of the earlier claimed light exotic mesons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of beam emission spectroscopy to NBI plasmas of Heliotron J

This paper describes the application of the beam emission spectroscopy (BES) to Heliotron J, having the nonsymmetrical helical-magnetic-axis configuration. The spectral and spatial profile of the beam emission has been estimated by the numerical calculation taking the collisional excitation processes between plasmas (electrons/ions) and beam atoms. Two sets of the sightlines with good spatial resolution are presented. One is the optimized viewing chords which have 20 sightlines and observe the whole plasma region with the spatial resolution {Delta}{rho} less than {+-}0.055 using the newly designed viewing port. The other is 15 sightlines from the present viewing port of Heliotron J for the preliminary measurement to discuss the feasibility of the density fluctuation measurement by BES. The beam emission has been measured by a monochromator with a CCD camera. A good consistency has been obtained between the spectral profiles of the beam emission measured by the monochromator and the beam emission spectrum deduced by the model calculation. An avalanche photodiode with an interference filter system was also used to evaluate the signal-to-noise (S/N) ratio of the beam emission in the present experimental setup. The modification of the optical system is being planned to improve the S/N ratio, which will enable us to estimate the density fluctuation in Heliotron J.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-GeV Electron Generation Using Texas Petawatt Laser

We present simulation results and experimental setup for multi-GeV electron generation by a laser plasma wake field accelerator (LWFA) driven by the Texas Petawatt (TPW) laser. Simulations show that, in plasma of density n{sub e} = 2-4x10{sup 17} cm{sup -3}, the TPW laser pulse (1.1 PW, 170 fs) can self-guide over 5 Rayleigh ranges, while electrons self-injected into the LWFA can accelerate up to 7 GeV. Optical diagnostic methods employed to observe the laser beam self-guiding, electron trapping and plasma bubble formation and evolution are discussed. Electron beam diagnostics, including optical transition radiation (OTR) and electron gamma ray shower (EGS) generation, are discussed as well.

43 PARTICLE ACCELERATORS↗

Hybrid Laser-Plasma Wakefield Acceleration

The concept of driving a driver/witness-type plasma wakefield accelerator (PWFA) with quasimonoenergetic double electron bunches from a laser wakefield accelerator (LWFA) is studied. In the quasimonoenergetic LWFA/SMLWFA (self-modulated LWFA) regime, it is possible to generate multiple quasimonoenergetic electron bunches with durations of only a few fs and distances of only a few tens of fs with a comparably simple experimental setup. In a subsequent high-density plasma afterburner stage the witness bunch energy can be boosted in the plasma wakefield generated by the driver. Such a hybrid system can increase the maximum energy output of a laser wakefield accelerator and is well suited to study driver/witness plasma accelerator phenomena and can be used as a cost-effective test-bed for future high-energy plasma-based accelerators.

43 PARTICLE ACCELERATORS↗

Stimulated emission in the red, green, and blue in a nanostructured glass ceramics

Red, green, and blue stimulated emissions have been achieved in Ho{sup 3+} doped oxyfluoride glass ceramic at room temperature. The material shows three emission bands at the red (650 nm), green (545 nm), and blue (488 nm) regions under infrared excitation at 750 nm. These emission bands are caused by a photon avalanche upconversion process previously reported. A pump and probe experimental setup has been designed to show stimulated emissions at the three bands. The pump power threshold for positive gain in the 490 nm band has been estimated around 2.7 kW/cm{sup 2}. Higher thresholds are expected for the other bands.

74 ATOMIC AND MOLECULAR PHYSICS↗

A new method to measure torsion moments on small-scaled specimens

As a result of a continuous evolution in the field of small-scaled components, an increasing need exists for mechanical characterization of single structures and materials in micrometer dimensions. Moreover, for a detailed analysis of the deformation and failure behavior, it is often necessary to perform investigations under multiaxial loading in addition to uniaxial loading. A simple possibility to create defined multiaxial stress-strain fields is offered by a torsion experiment. In the frame of this work, a new method is presented, which allows determining torsion moments applied to wires as thin as 10 {mu}m in monotonic as well as cyclic manner. Besides a detailed description of the measuring principle, the experimental setup and the first results will be presented. In particular, investigations on gold wires with diameters ranging from 10 to 60 {mu}m, applying torsion moments in the nNm regime, are shown.

36 MATERIALS SCIENCE↗

Experimental Studies of Ion Beam Neutralization: Preliminary Results

A testing platform is designed to study ion beam neutralization in the mesothermal, collisionless region. In the experimental setup, argon neutrals were ionized in a microwave cavity and accelerated by a plasma lens system which was biased to 2500 V above the system ground. Electrons were boiled off from two hot tungsten filaments to neutralize the ion beam. The plasma is diagnosed using Langmuir probe and Faraday probe. A 3-D traversing system and a complete data acquisition loop were developed to efficiently measure 3-D beam profile. Preliminary measurements of beam profiles are presented for different operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laboratory measurements and theoretical modeling of seismoelectric interface response and coseismic wave fields

A full-waveform seismoelectric numerical model incorporating the directivity pattern of a pressure source is developed. This model provides predictions of coseismic electric fields and the electromagnetic waves that originate from a fluid/porous-medium interface. An experimental setup in which coseismic electric fields and interface responses are measured is constructed. The seismo-electric origin of the signals is confirmed. The numerically predicted polarity reversal of the interfacial signal and seismoelectric effects due to multiple scattering are detected in the measurements. Both the simulated coseismic electric fields and the electromagnetic waves originating from interfaces agree with the measurements in terms of travel times, waveform, polarity, amplitude, and spatial amplitude decay, demonstrating that seismoelectric effects are comprehensively described by theory.

58 GEOSCIENCES↗

Design and characterization of optical heads for interferometric ballistic velocity measurements

The design of optical fiber based heads offering high accuracy and bandwidth for use in VISAR (velocity interferometer system for any reflector) experiments measuring ballistic velocities is described. A new, expanded, model for predicting the distance-dependent collection efficiency of the heads is presented. The model is shown to agree very well with experimental results, both within and outside the ''depth of field''. Various optical heads are demonstrated, to suit different experimental setups and conditions. Designs offering options for high bandwidths, accurate prealignment, and large stand-off distances are discussed. Results from a typical VISAR experiment are presented, verifying that our designs yield high-quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conducting Well-Controlled Ion Irradiations To Understand Neutron Irradiation Effects In Materials

A firm understanding of the effect of radiation on materials is required to develop predictive models of materials behavior in-reactor and provide a foundation for creating new, more radiation-tolerant materials. Ion irradiation can serve this purpose for nuclear reactor components and is becoming a key element of materials development for advanced nuclear reactors. Ion irradiations can be conducted quickly, at low cost, and with precise control over irradiation temperature, temperature uniformity, dose rate, dose uniformity and total dose. During proton irradiations the 2{sigma}(twice the standard deviation) of the sample temperature is generally below {approx}7 deg. C, the dose rate variation {approx}3%, the dose uncertainty {approx}3%, and there is an excellent temperature and dose uniformity across the irradiated area. In this article, we describe the experimental setup and irradiation procedure used to conduct well-controlled ion irradiations at the University of Michigan.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of electron density with the phase-resolved cut-off probe method

The phase resolved cut-off probe method, a precise measurement method for the electron density, was recently proposed [J. H. Kwon et al., Appl. Phys. Lett. 96, 081502 (2010)]. This paper presents the measurements of electron density using the method under various experimental conditions (different pressures, powers, chamber volumes, and discharge sources). The result shows that the method is not only in good agreement with the previous method using wave transmittance under various experimental conditions but it is also able to find the cut-off point clearly even under difficult conditions such as high pressure ({approx} 1 Torr), high discharge power, and small plasma volume. The details of the experimental setup, the operating mechanism of the probe method, and the data processing procedure (algorithm) are also addressed. Furthermore, the reliability of the measurement method is investigated by using an electromagnetic field simulation with cold plasma model (CST-Drude model, Computer Simulation Technology).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the implementation of computed laminography using synchrotron radiation

Hard x rays from a synchrotron source are used in this implementation of computed laminography for three-dimensional (3D) imaging of flat, laterally extended objects. Due to outstanding properties of synchrotron light, high spatial resolution down to the micrometer scale can be attained, even for specimens having lateral dimensions of several decimeters. Operating either with a monochromatic or with a white synchrotron beam, the method can be optimized to attain high sensitivity or considerable inspection throughput in synchrotron user and small-batch industrial experiments. The article describes the details of experimental setups, alignment procedures, and the underlying reconstruction principles. Imaging of interconnections in flip-chip and wire-bonded devices illustrates the peculiarities of the method compared to its alternatives and demonstrates the wide application potential for the 3D inspection and quality assessment in microsystem technology.

43 PARTICLE ACCELERATORS↗

Response to 'Comment on 'Controllable local modification of fractured Nb-doped SrTiO{sub 3} surfaces' [Appl. Phys. Lett. 98, 256102 (2011)'.

In their comment, Chen et al. try to argue that the experimentally observed controllable voltage-induced surface modification, which was attributed to a local electric field-induced atom transfer from the surface to the tip, is rather caused by either an oxidation process and/or a resistance change. In this response, we will show that we can rule out these two effects in our experiment. The statements by Chen et al. are based on two arguments: (1) the tip modification after transferring an adatom should alter the dI/dV contrast, which was not seen in our experiments and (2) the vacuum conditions in our experiment are similar to earlier reports on resistance switching. First, Chen et al. discuss that the adsorption on the tip should alter the topographic contrast, as many papers have reported. In fact, in our experiments we frequently observed tip modifications at high bias voltage. These typically result in slight changes in scanning tunneling spectroscopy data [see, for example, the spectra in Fig. 3(b) in Ref. 4 and Fig. 2(d) of Ref. 5] but only weakly affected the topographic contrast. Second, Chen et al. claim that oxidation is another possible mechanism to explain our experimental observations. To support this claim, they compare our results to an earlier publication showing resistance switching. In fact, the resistance switching mechanism is related to oxygen vacancy migration or local surface oxidation. The mechanism of oxygen vacancy migration requires a 'forming' process with a threshold current in the order of microampere or even milliampere. In our experimental setup, however, we used tunneling currents in the order of 50 pA. Even during surface modification, which was performed at open feedback loop conditions with voltage pulse of up to 3 or -5 V, the maximum transient current did not exceed a few nanoampere. Therefore, we can safely exclude oxygen vacancy migration as a potential mechanism for the observed surface modification. As a second potential mechanism Chen et al. mention a local surface oxidation process. However, the total pressure at high-vacuum conditions used in experiments, where resistance switching was observed (10{sup -7} torr in Ref. 3) is three order magnitude higher than in our experiment performed under ultrahigh vacuum (UHV) conditions (below 10{sup -10} torr). Furthermore, mass spectra measured with a residual gas analyzer show that the main residue gas in our UHV system is hydrogen ({approx} 90%). Water, oxygen, and other oxygen-related gases are negligible with a partial pressure in the order of 10{sup -12} torr range or lower. Therefore, we can also exclude that local oxidation with reactants from the residual gas causes the observed modifications. In addition, in our experiment, the refilling of the modified areas at negative bias could not be observed with fresh tip, even for bias voltages as high as -10 V. In short, the mechanism for the modification on the UHV in situ fractured Nb:SrTiO{sub 3} (Nb-doped Strontium titanate) surfaces with scanning tunneling microscope (STM) tip is different from the mechanisms such as local surface oxidation or filament formation, used to explain the largecurrent induced resistance switching works.

08 HYDROGEN↗

Experimental demonstration of early time, hohlraum radiation symmetry tuning for indirect drive ignition experiments

Early time radiation symmetry at the capsule for indirect drive ignition on the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Nucl. Fusion 44, 228 (2004)] will be inferred from the instantaneous soft x-ray re-emission pattern of a high-Z sphere replacing the ignition capsule. This technique was tested on the OMEGA laser facility [J. M. Soures, R. L. McCrory, T. Boehly et al., Laser Part. Beams 11, 317 (1991)] in near full ignition scale vacuum hohlraums using an equivalent experimental setup to the one planned for NIF. Two laser cones entering each laser entrance hole heat the hohlraums to radiation temperatures of 100 eV, mimicking the NIF ignition pulse foot drive. The experiments have demonstrated accuracies of {+-}1.5% ({+-}2%) in inferred P{sub 2}/P{sub 0} (P{sub 4}/P{sub 0}) Legendre mode incident flux asymmetry and consistency between 900 eV and 1200 eV re-emission patterns. We have also demonstrated the expected tuning capability of P{sub 2}/P{sub 0}, from positive (pole hot) to negative (waist hot), decreasing linearly with the inner/outer beams power fraction. P{sub 4}/P{sub 0} on the other hand shows very little variation with power fraction. We developed a simple analytical viewfactor model that is in good agreement with both measured P{sub 2}/P{sub 0} and P{sub 4}/P{sub 0} and their dependence on inner beam power fraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The EXL experiment at FAIR and plans with the ESR at GSI

In this contribution, the physics program of the EXL experiment at FAIR-NuSTAR along with its experimental setup will be briefly outlined. This experiment aims to study the structure and the dynamics of radioactive nuclei which collide with light ions in inverse kinematics. On the way to the final measurements, several measurements have been proposed at the existing ESR at GSI with the purpose of understanding the detection systems for EXL and obtaining the first physics results in this type of experiments in a storage ring.