Search NASA⌕ Search

SEARCH · Search NASA

Results for “fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A Variation of the F-Test for Determining Statistical Relevance of Particular Parameters in EXAFS Fits

A general problem when fitting EXAFS data is determining whether particular parameters are statistically significant. The F-test is an excellent way of determining relevance in EXAFS because it only relies on the ratio of the fit residual of two possible models, and therefore the data errors approximately cancel. Although this test is widely used in crystallography (there, it is often called a 'Hamilton test') and has been properly applied to EXAFS data in the past, it is very rarely applied in EXAFS analysis. We have implemented a variation of the F-test adapted for EXAFS data analysis in the RSXAP analysis package, and demonstrate its applicability with a few examples, including determining whether a particular scattering shell is warranted, and differentiating between two possible species or two possible structures in a given shell.

36 MATERIALS SCIENCE↗

Transverse impedance measurement using response matrix fit method at APS.

The Advanced Photon Source (APS) is a third-generation synchrotron light source based on a 7-GeV electron storage ring. In third-generation light sources the synchrotron radiation is mainly produced in undulators. In order to achieve high photon flux and tunability, the magnet gap in undulators has to be as small as possible. Therefore, the undulators are installed on dedicated small-gap insertion device (ID) vacuum chambers. APS has thirty-five 5-m-long straight sections available for undulators. At the time of the measurements, there were 31 straight sections occupied with various insertion devices, and 4 straight sections were still empty. Most of the ID vacuum chambers have a 8-mm in-vacuum gap, and two chambers have a 5-mm gap. These narrow-gap vacuum chambers are believed to be the main source of the transverse impedance of the machine. One can measure the combined impedance by measuring the transverse tune slope with single-bunch current. Comparing this slope before and after installation of the narrow-gap vacuum chamber, one can deduce the impedance of the chamber. It is difficult to accurately measure the change in the tune slope after one or a few new ID chambers are installed. If several identical ID vacuum chambers are installed over a period of time, then one can estimate the contribution of one ID chamber. Over the last few years there have been a number of attempts to measure the impedance of separate components of accelerators. Phase-advance measurements from beam position monitor (BPM) turn-by-turn histories were used at LEP to measure the impedance distribution around the ring. Researches at LEP were able to fit average impedance in the long sections of the LEP arc and determine the impedance of the rf sections. The method was tried at APS; however, the accuracy of the measurements was not enough to determine the small impedance of a single ID vacuum chamber. There is also a different approach that uses local orbit bumps to probe different parts of an accelerator. The orbit bump method was done at BINP, APS, and ESRF. All these methods have one common feature: they employ the fact that the beam sees the impedance as an additional defocusing quadrupole whose strength depends on the beam current. At APS we use an orbit response matrix fit to determine the distribution of focusing errors around the machine, and then use these errors to calculate beta functions. Since the beam sees the impedance as a quadrupole whose strength depends on the beam current, the measurement of the beta functions with different currents could be used to determine the impedance distribution around the machine. This approach was first used at APS and reported in.

43 PARTICLE ACCELERATORS↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modified moment-fitted integration scheme for X-FEM applications with history-dependent material data

Here, we present a strategy for the numerical integration of partial elements with the eXtended finite element method (X-FEM). The new strategy is specifically designed for problems with propagating cracks through a bulk material that exhibits inelasticity. Following a standard approach with the X-FEM, as the crack propagates into new regions of the domain, elements are split into several copies that contain pieces of the domain on either side of the crack. We examine quadrature rules that have sufficient accuracy to calculate stiffness matrices regardless of the orientation of the crack with respect to the element. This permits the number of integration points within elements to remain constant as a crack propagates, and for state data to be easily transferred between successive discretizations. In order to maintain weights that are strictly positive, we propose an approach that blends moment-fitted weights with volume-fraction based weights. To demonstrate the efficacy of this simple approach, we present results from numerical tests and examples with both elastic and plastic material response.

42 ENGINEERING↗

Investigation of goodness of model data fit using PLSR and PCR regression models to determine informative wavelength band in NIR region for non-invasive blood glucose prediction

Diabetes mellitus is a metabolic disorder characterized by the deficiency in insulin secretion or insulin action on target tissues. Diabetes being diagnosed, requires frequent monitoring. Current measurement techniques are invasive in nature, which is painful. Non-invasive measurement methods for the prediction of blood glucose is a big challenge. Hence this paper focuses on a comparative study to analyze the performance of the two regression models: partial least square regression (PLSR) and principal component regression (PCR) models to arrive at the best regression model for the prediction of blood glucose non-invasively based on NIR diffuse reflectance spectroscopy. The regression model developed involves spectral data collected from 32 subjects from a diabetic center using diffuse reflectance spectrometer (DRS). The spectroscopic data were acquired from the subjects both invasively using clinical method and non-invasively using DRS setup in the NIR spectral range whose wavelength ranges from 750 to 1040 nm. Multivariate analysis using PLSR is found to be a better regression model in terms of the fitted response and estimated mean square prediction error. It is observed that the mean square error value is 0.04 mg/dl for the tenth component in the PLSR model. The developed regression model also proves to be a useful tool in identifying the informative wavelength bands for blood glucose measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gene-by-environment interactions influence the fitness cost of gene copy-number variation in yeast

Abstract Variation in gene copy number can alter gene expression and influence downstream phenotypes; thus copy-number variation provides a route for rapid evolution if the benefits outweigh the cost. We recently showed that genetic background significantly influences how yeast cells respond to gene overexpression, revealing that the fitness costs of copy-number variation can vary substantially with genetic background in a common-garden environment. But the interplay between copy-number variation tolerance and environment remains unexplored on a genomic scale. Here, we measured the tolerance to gene overexpression in four genetically distinct Saccharomyces cerevisiae strains grown under sodium chloride stress. Overexpressed genes that are commonly deleterious during sodium chloride stress recapitulated those commonly deleterious under standard conditions. However, sodium chloride stress uncovered novel differences in strain responses to gene overexpression. West African strain NCYC3290 and North American oak isolate YPS128 are more sensitive to sodium chloride stress than vineyard BC187 and laboratory strain BY4743. Consistently, NCYC3290 and YPS128 showed the greatest sensitivities to overexpression of specific genes. Although most genes were deleterious, hundreds were beneficial when overexpressed—remarkably, most of these effects were strain specific. Few beneficial genes were shared between the sodium chloride-sensitive isolates, implicating mechanistic differences behind their sodium chloride sensitivity. Transcriptomic analysis suggested underlying vulnerabilities and tolerances across strains, and pointed to natural copy-number variation of a sodium export pump that likely contributes to strain-specific responses to overexpression of other genes. Our results reveal extensive strain-by-environment interactions in the response to gene copy-number variation, raising important implications for the accessibility of copy-number variation-dependent evolutionary routes under times of stress.

60 APPLIED LIFE SCIENCES↗

Bacterial fitness for plant colonization is influenced by plant growth substrate

Despite advances in our understanding of bacterial plant colonization, the extent to which growth substrate influences the molecular mechanisms enabling bacteria to efficiently colonize plants remains poorly understood. To address this, we used randomly barcoded transposon mutagenesis sequencing (RB-TnSeq) in Paraburkholderia graminis OAS925, an efficient rhizosphere colonizer, and Brachypodium distachyon grown in six different substrates. Of the 382 rhizosphere colonization genes that we identified in OAS925, 348 genes (91.1%) are dependent on the growth substrate evaluated, and 34 genes (8.9%) are shared across all the substrates. Both the core and substrate-dependent colonization genes are from multiple functional categories, demonstrating the multifaceted and major impact that plant growth substrate has on bacterial colonization. The identified colonization genes and their varied importance across plant growth substrates could not be readily explained by differences in root exudate profiles, suggesting that the substrate environment itself plays an outsized role in the ability of a bacterium to colonize the rhizosphere. Our data confirm that bacterial fitness for plant colonization is strongly influenced by plant growth substrate type and highlights the importance of taking this parameter into consideration when engineering bacterial strains for improved host colonization.

Paraburkholderia↗

Experimental Characterization and Modeling of Thermal Contact Resistance of Electric Machine Stator-to-Cooling Jacket Interface Under Interference Fit Loading

Cooling of electric machines is a key to increasing power density and improving reliability. This paper focuses on the design of a machine using a cooling jacket wrapped around the stator. The thermal contact resistance (TCR) between the electric machine stator and cooling jacket is a significant factor in overall performance and is not well characterized. This interface is typically an interference fit subject to compressive pressure exceeding 5 MPa. An experimental investigation of this interface was carried out using a thermal transmittance setup using pressures between 5 and 10 MPa. Furthermore, the results were compared to currently available models for contact resistance, and one model was adapted for prediction of TCR in future motor designs.

30 DIRECT ENERGY CONVERSION↗

Smart medical systems with application to nutrition and fitness in space

Smart medical systems are being developed to allow medical treatments to address alterations in chemical and physiologic status in real time. In a smart medical system, sensor arrays assess subject status, which is interpreted by computer processors that analyze multiple inputs and recommend treatment interventions. The response of the subject to the treatment is again assessed by the sensor arrays, thus closing the loop. An early form of "smart medicine" has been practiced in space to assess nutrition. Nutrient levels are assessed with food frequency questionnaires, which are interpreted by flight surgeons to recommend inflight alterations in diet. In the future, sensor arrays will directly probe body chemistry. Near-infrared spectroscopy can be used to non-invasively measure several blood and tissue parameters that are important in the assessment of nutrition and fitness. In particular, this technology can be used to measure blood hematocrit and interstitial fluid pH. The non-invasive measurement of interstitial pH is discussed as a surrogate for blood lactate measurement for the development and real-time assessment of exercise protocols in space. Earth-based application of these sensors is also described.

NASA Discipline Life Sciences Technologies↗