Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

In-situ Synthesis of PuCl 3 and Corresponding Raman and Density Functional Theory Vibrational Modes

The experimental and calculated Raman spectrum of PuCl 3 has been reported for the first time. PuCl 3 is a primary species found in plutonium metal refinement, specifically in pyrochemical salt processes including multicycle direct oxide reduction, metal chlorination, and electrorefining. As such, Raman signatures of PuCl 3 could serve as potential forensic indicators of material process history. A novel technique for synthesizing PuCl 3 from the in situ chlorination of plutonium metal with HCl was developed to establish these signatures. Cerium metal surrogates were utilized to ensure optimization of the plutonium experiments and to minimize personnel exposure, and all experiments were carried out in a Raman reaction chamber designed for air-tight, high vacuum environments. In situ Raman spectroscopy was employed in conjunction with density functional theory (DFT) to investigate the vibrational modes of PuCl 3 . Associated mixed oxy and hydroxyl phases are also reported. The combined Raman and DFT results have eliminated inconsistencies in Raman mode assignments for the MX 3 family of metal chlorides having P6 3 /m symmetry, and IR modes derived from the DFT calculations are additionally presented. The data observed in this study are of potential interest to nuclear forensic analyses, nuclear sample aging, nuclear energy, plutonium processing, and stockpile stewardship.

36 MATERIALS SCIENCE↗

Image Provenance Analysis

The literature of multimedia forensics is mainly dedicated to the analysis of single assets (such as sole image or video files), aiming at individually assessing their authenticity. Different from this, image provenance analysis is devoted to the joint examination of multiple assets, intending to ascertain their history of edits, by evaluating pairwise relationships. Each relationship, thus, expresses the probability of one asset giving rise to the other, through either global or local operations, such as data compression, resizing, color-space modifications, content blurring, and content splicing. The principled combination of these relationships unveils the provenance of the assets, also constituting an important forensic tool for authenticity verification. This chapter introduces the problem of provenance analysis, discussing its importance and delving into the state-of-the-art techniques to solve it.

Moreira, Daniel↗

Contribution of bulk mass spectrometry isotopic analysis to characterization of materials in the framework of CMX-4

Seven laboratories used the results of bulk uranium isotopic analysis by either inductively coupled plasma mass spectrometry (ICP-MS) or thermal ionization mass spectrometry (TIMS) for characterization of the samples in the Nuclear Forensic International Technical Working Group fourth international collaborative material exercise, CMX-4. Comparison of the measured isotopic compositions of uranium in three exercise samples is implemented for identifying any differences or similarities between the samples. The role of isotopic analyses in the context of a real nuclear forensic investigation is discussed. Several limitations in carrying out ICP-MS or TIMS analysis in CMX-4 are noted.

07 ISOTOPE AND RADIATION SOURCES↗

International inter-comparison exercise on $${}^{153}\hbox {Sm}$$153Sm

Samarium-153 ( 153 Sm) is one of the many isotopes of interest to the nuclear forensics community. This short-lived radionuclide decays to stable europium-153 via beta emission, with subsequent de-excitation via gamma emission and internal conversion. Historical measurements of 153 Sm by gamma spectrometry and beta liquid scintillation counting have shown a low bias compared to beta proportional counting. In order to investigate this, four national laboratories jointly conducted an experimental inter-comparison exercise on a certified 153Sm sample, created from neutron activation of samarium-152. Radiometric measurements were conducted using gamma spectrometry, liquid scintillation, gas proportional counting, and passivated implanted planar silicon detectors and compared across the four institutions against the certificate. The results from this experiment are presented together with a number of conclusions which suggest that the current published cumulative fission yield for 153 Sm, as used by many laboratories, is approximately 15% high and is the likely cause of the previously observed historical bias.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rare-earth element fractionation in uranium ore and its U(VI) alteration minerals

We developed a cation exchange chromatography method employing sulfonated polysterene cation resin (DOWEX AG50-X8) in order to separate rare-earth elements (REEs) from uranium-rich materials. The chemical separation scheme is designed to reduce matrix effects and consequently yield enhanced ionization efficiencies for concentration determinations of REEs without significant fractionation using solution mode-inductively coupled plasma mass spectrometry (ICP-MS) analysis. This method was then applied to determine REE abundances in four uraninite (ideally UO 2 ) samples and their associated U(VI) alteration minerals. In three of the samples analyzed, the concentration of REEs for primary uraninite are higher than those for their corresponding secondary uranium alteration phases. The results for U(VI) alteration minerals of two samples indicate enrichment of the light REEs (LREEs) over the heavy REEs (HREEs). This differential mobilization is attributed to differences in the mineralogical composition of the U(VI) alteration. There is a lack of fractionation of the LREEs in the uraninite alteration rind that is composed of U(VI) minerals containing Ca 2+ as the interlayer cation (uranophane and bequerelite); contrarily, U(VI) alteration minerals containing K + and Pb 2+ as interlayer cations (fourmarierite, dumontite) indicate fractionation (enrichment) of the LREEs. Our results have implications for nuclear forensic analyses since a comparison is reported between the REE abundances for the CUP-2 (processed uranium ore) certified reference material and previously determined values for uranium ore concentrate (UOC) produced from the same U deposit (Blind River/Elliott Lake, Canada). UOCs represent the most common form of interdicted nuclear material and consequently is material frequently targeted for forensic analysis. The comparison reveals similar chondrite normalized REE signatures but variable absolute abundances. Based on the results reported here, the latter may be attributed to the differing REE abundances between primary ore and associated alteration phases, and/or is related to varying fabrication processes adopted during production of UOC.

58 GEOSCIENCES↗

Profiling of Volatile Impurities in Tetramethylenedisulfotetramine (TETS) for Synthetic-Route Determination

This study investigated the feasibility of using volatile impurities from the rodenticide tetramethylenedisulfotetramine (TETS) for the discrimination of TETS produced by three synthetic routes. Each route was used to make one batch of TETS by reacting sulfamide with one of three formaldehyde analogs in the presence of either trifluroacetic acid (TFA) or hydrochloric acid. Ten impurities useful for differentiating the three TETS batches were sampled and tentatively identified by headspace solid-phase microextraction comprehensive two-dimensional gas chromatography-mass spectrometry (HS-SPME/GC x CG-MS). Of the ten identified impurities, the alkyl trifluoroacetate and alkyl chloride impurities distinguished TETS routes based on their use of either TFA or HCl as catalyst. On the other hand, four 6-carbon ketone impurities appeared to be batch specific rather than route specific and hence potentially useful for sample matching. Interestingly, 1,3,5-trioxane was not found in the TETS batch where it was used as a reactant, but instead was found in the two batches that did not have 1,3,5-trioxane as the reactant. In summary, the limited work discussed in this paper supports: (1) the feasibility of sampling and detecting volatile organic impurities from a solid chemical-threat agent, (2) the probable forensic benefit of catalysts acting as reactants in side reactions, (3) the uniqueness of a synthetic batch’s impurity profile for potential sample matching, and (4) the possibility that some impurities, such as formaldehyde analogs, are not forensically helpful and may lead to an incorrect estimate about the synthetic route if not supported by sound chemical knowledge.

Fraga, Carlos G.↗

JTAG-based PLC memory acquisition framework for industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLC) are the embedded devices that directly control and monitor critical industrial infrastructure processes such as nuclear plants and power grid stations. Cyberattacks often target PLCs to sabotage a physical process. A memory forensic analysis of a suspect PLC can answer questions about an attack, including compromised firmware and manipulation of PLC control logic code and I/O devices. Given physical access to a PLC, collecting forensic information from the PLC memory at the hardware-level is risky and challenging. It may cause the PLC to crash or hang since PLCs have proprietary, legacy hardware with heterogeneous architecture. This paper addresses this research problem and proposes a novel JTAG (Joint Test Action Group)-based framework, Kyros, for reliable PLC memory acquisition. Kyros systematically creates a JTAG profile of a PLC through hardware assessment, JTAG pins identification, memory map creation, and optimizing acquisition parameters. It also facilitates the community of interest (such as ICS owners, operators, and vendors) to develop the JTAG profiles of PLCs. Further, we present a case study of Kyros implementation over Allen-Bradley 1756-A10/B to help understand the framework's application on a real-world PLC used in industry settings. The sample PLC memory dumps are shared with the research community to facilitate further research.

Rais, Muhammad Haris↗

Three-dimensional microstructural characterization of bulk plutonium and uranium metals using focused ion beam technique

Nuclear forensics requires accurate quantification of discriminating microstructural characteristics of the bulk nuclear material to identify its process history and provenance. Conventional metallographic preparation techniques for bulk plutonium (Pu) and uranium (U) metals are limited to providing information in two-dimension (2D) and do not allow for obtaining depth profile of the material. In this contribution, use of dual-beam focused ion-beam/scanning electron microscopy (FIB-SEM) to investigate the internal microstructure of bulk Pu and U metals is demonstrated. Our results demonstrate that the dual-beam methodology optimally elucidate microstructural features without preparation artifacts, and the three-dimensional (3D) characterization of inner microstructures can reveal salient microstructural features that cannot be observed from conventional metallographic techniques. As a result, examples are shown to demonstrate the benefit of FIB-SEM in improving microstructural characterization of microscopic inclusions, particularly with respect to nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative Morphological Characterization of Carbide Inclusions in Uranium Metal

Uranium carbides (UCs) are prevalent inclusions in U metal that form during melting operations from interactions with crucible walls and the casting chamber atmosphere. Although UCs have been studied extensively since the beginning of U metal foundry operations, there are still unknowns regarding the effects of thermomechanical processing on their sizes and morphology. Here, we present the results of a series of controlled cooling experiments with molten uranium to elucidate the effect of cooling rate on inclusion morphology in a-U. Samples were melted using a vacuum induction melter and manually cooled at rates of 2.5, 1.7, 1.1, 0.8, 0.3 (± 1%) K/s from ~1600 K to <700 K in under 1 hour. Subsequent scanning electron microscopy (SEM) was performed on cross-sections of the samples, revealing a complex mixture of UC morphologies that are indicative of diffusion and growth influenced by the thermal processing of the U matrix. Image analysis using the Morphological Analysis of Materials (MAMA) software showed that UC sizes generally grew larger with slower cooling rates, and the two slowest cooling rates noticeably impacted the inclusion circularity and ellipse aspect ratio. These results indicate that UC morphology is sensitive to short cooling rates (<1 hour) and could therefore be controlled in the production of metallic nuclear fuels. Additionally, inclusion speciation and morphologies could potentially provide forensic clues about processing history of unknown metal samples. Understanding the driving forces involved in UC morphology evolution is beneficial for evaluating metal fuels for next generation nuclear reactors and for identifying signatures for nuclear forensics.

Athon, Matthew T.↗

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Signature-Discovery Approach for Sample Matching of a Nerve-Agent Precursor using Liquid Chromatography–Mass Spectrometry, XCMS, and Chemometrics

This report demonstrates the use of bioinformatic and chemometric tools on liquid chromatography mass spectrometry (LC-MS) data for the discovery of ultra-trace forensic signatures for sample matching of various stocks of the nerve-agent precursor known as methylphosphonic dichloride (dichlor). The use of the bioinformatic tool known as XCMS was used to comprehensively search and find candidate LC-MS peaks in a known set of dichlor samples. These candidate peaks were down selected to a group of 34 impurity peaks. Hierarchal cluster analysis and factor analysis demonstrated the potential of these 34 impurities peaks for matching samples based on their stock source. Only one pair of dichlor stocks was not differentiated from one another. An acceptable chemometric approach for sample matching was determined to be variance scaling and signal averaging of normalized duplicate impurity profiles prior to classification by k-nearest neighbors. Using this approach, a test set of dichlor samples were all correctly matched to their source stock. The sample preparation and LC-MS method permitted the detection of dichlor impurities presumably in the parts-per-trillion (w/w). The detection of a common impurity in all dichlor stocks that were synthesized over a 14-year period and by different manufacturers was an unexpected discovery. Our described signature-discovery approach should be useful in the development of a forensic capability to help in criminal investigations following chemical attacks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Learning-Enabled MS/MS Spectrum Prediction Facilitates Automated Identification Of Novel Psychoactive Substances

The market for illicit drugs has been reshaped by the emergence of more than 1100 new psychoactive substances (NPS) over the past decade, posing a major challenge to the forensic and toxicological laboratories tasked with detecting and identifying them. Tandem mass spectrometry (MS/MS) is the primary method used to screen for NPS within seized materials or biological samples. The most contemporary workflows necessitate labor-intensive and expensive MS/MS reference standards, which may not be available for recently emerged NPS on the illicit market. Here, we present NPS-MS, a deep learning method capable of accurately predicting the MS/MS spectra of known and hypothesized NPS from their chemical structures alone. NPS-MS is trained by transfer learning from a generic MS/MS prediction model on a large data set of MS/MS spectra. We show that this approach enables a more accurate identification of NPS from experimentally acquired MS/MS spectra than any existing method. We demonstrate the application of NPS-MS to identify a novel derivative of phencyclidine (PCP) within an unknown powder seized in Denmark without the use of any reference standards. We anticipate that NPS-MS will allow forensic laboratories to identify more rapidly both known and newly emerging NPS. NPS-MS is available as a web server at https://nps-ms.ca/, which provides MS/MS spectra prediction capabilities for given NPS compounds. Additionally, it offers MS/MS spectra identification against a vast database comprising approximately 8.7 million predicted NPS compounds from DarkNPS and 24.5 million predicted ESI-QToF-MS/MS spectra for these compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Position-Specific Carbon Isotope Fingerprinting of Fluorinated Organics and Degradation Products

Fluorinated organic compounds are of growing environmental and forensic relevance due to their widespread use in pharmaceuticals, agrochemicals, and consumer products, their environmental persistence, and potential ecological and human health impacts. Elucidating their sources and transformation pathways is therefore a major focus of current research. Stable carbon isotope analysis provides a powerful approach for tracing molecular origins and linking parent compounds to degradation products. Recent isotope measurements have largely relied on mass-spectrometry techniques, which provide only an average isotope ratio across a compound. In this work, we employ a novel nuclear magnetic resonance (NMR) spectroscopy tool to determine position-specific carbon isotope ratios ( 13 C/ 12 C) in organofluorine compounds and their degradation products. This approach enables isotope measurements without combustion or extensive purification and, crucially, resolves ratios at individual carbon positions rather than bulk averages. The resulting intramolecular isotope fingerprints are unique to a molecule’s source. Applied to selected pharmaceuticals and pesticides, these fingerprints allow discrimination of chemically identical compounds. Moreover, we show that the 13 C/ 12 C signature at the fluorinated carbon persists through degradation, demonstrated for lansoprazole and fipronil. The 19 F NMR data produced for the 13 C/ 12 C analyses are also well suited for impurity profiling, providing an additional dimension for fingerprinting fluorinated organics. These findings suggest that position-specific isotope analysis can serve as part of a broader suite of tools for source characterization of organofluorine compounds and their breakdown derivatives, with potential applications in product validation, forensics, and linking these compounds to their breakdown products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and Crystal Structures of Volatile Neptunium(IV) β-Diketonates

There is a large need for neptunium certified reference materials to support domestic nuclear forensics programs. These reference materials are required for quantification of Np forensic related samples. Isotopic separation is required to produce this material; traditional isotopic separation methods use electromagnetic separation techniques. Such methods require a gaseous introduction of Np into the separation source. This work sought to produce a volatile Np compound that would be suitable for the purpose of certified reference material production. ß-diketonates were identified as compounds likely able to serve this purpose. However, previously described synthesis requires NpCl4, which is not commercially available and prohibitively difficult to produce. A novel and facile procedure was developed here to successfully synthesize several tetravalent ß-diketonates of Np. They were characterized using FTIR and single crystal x-ray diffraction. The volatility of these compounds at elevated temperatures was then analyzed, and discussed. The synthesis procedure developed here presents a facile platform for further Np organometallic studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbamoylation as an Effective Tool in the Analysis of the Soman Nerve Agent Marker Pinacolyl Alcohol in Soil Matrices by EI-GC-MS and LC-HRMS

Pinacolyl alcohol (PA) is a Schedule 2 chemical commonly featured in most proficiency tests (PTs) administered by the Organisation for the Prohibition of Chemical Weapons (OPCW) due to its direct as well as forensic link to the nerve agent Soman. Therefore, its detection by Chemical Weapons Convention (CWC) inspection teams during on-site investigations is a strong indicator of the past or latent presence of Soman in the environment. Its small molecular weight (102), early elution time, and poor ionization profile make PA a challenging analyte to detect particularly at low concentrations (∼1–10 μg/g). In this work, 1,1′-carbonyldimidazole (CDI) has been used to effectively modify PA for the first time in two different soil matrices (Virginia type A soil and silt sediment) at two separate concentrations (1 and 10 μg/g) for its subsequent detection by EI-GC-MS and LC-HRMS methods. For the EI-GC-MS analysis, the PA carbamate derivative (PIC) exhibits improved chromatography relative to PA such as improved peak shape, increased molecular weight (196 for PIC and 102 for PA) and increased retention time (16.9 min for PIC and ∼4.1 min for PA). In addition, the derivatization also improves the detection of PA by LC-HRMS as the PIC product possesses protonation sites (i.e., imidazole ring) relative to none exhibited by PA. More importantly, the carbamoylation proceeds under mild conditions (55 °C, no base) and rapidly (3 h), characteristics that make it an appealing protocol for the analysis of PA during OPCW PTs or real case scenarios particularly in instances where it is present at low concentrations. It is anticipated that the protocol can be applied to the forensic analysis of this important Soman marker in various environmental matrices.

Chemistry↗

Strontium isoscape of sub-Saharan Africa allows tracing origins of victims of the transatlantic slave trade

Abstract Strontium isotope ( 87 Sr/ 86 Sr) analysis with reference to strontium isotope landscapes (Sr isoscapes) allows reconstructing mobility and migration in archaeology, ecology, and forensics. However, despite the vast potential of research involving 87 Sr/ 86 Sr analysis particularly in Africa, Sr isoscapes remain unavailable for the largest parts of the continent. Here, we measure the 87 Sr/ 86 Sr ratios in 778 environmental samples from 24 African countries and combine this data with published data to model a bioavailable Sr isoscape for sub-Saharan Africa using random forest regression. We demonstrate the efficacy of this Sr isoscape, in combination with other lines of evidence, to trace the African roots of individuals from historic slavery contexts, particularly those with highly radiogenic 87 Sr/ 86 Sr ratios uncommon in the African Diaspora. Our study provides an extensive African 87 Sr/ 86 Sr dataset which includes scientifically marginalized regions of Africa, with significant implications for the archaeology of the transatlantic slave trade, wildlife ecology, conservation, and forensics.

Science & Technology - Other Topics↗