Search NASA⌕ Search

SEARCH · Search NASA

Results for “guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

ESTABLISHING ETHICAL GUIDELINES FOR APPLYING ARTIFICIAL INTELLIGENCE TO IAEA SAFEGUARDS

Drawing upon globally recognized efforts by a variety of institutions, the paper develops a practical and defensible framework for consideration and use by the International Atomic Energy Agency (IAEA) to support the adoption of credible ethical standards for autonomous and intelligent systems (AIS). The analysis is based on a future hypothetical AIS that identifies signatures of misuse, diversion, and other research and development (R&D). The hypothetical system serves as an exemplar for subject matter expert (SME) workshop participants to begin to answer ethical AIS questions around how these systems should be governed and maintained, what the internal and external considerations associated with artificial intelligence (AI) tools are, and where the boundaries between ethical and non-ethical uses are. The ethical AIS workshop explored several important topics: (a) Recommendations that can be currently implemented by the IAEA, (b) Proposed defensible criteria and metrics aligned with an ethical AI for safeguards implementation, (c) Discussion of future needs and capabilities, and (d) Derive appropriate next steps and actions to support filling current technological, operational, and cultural gaps and realizing an effective ethical AI for safeguards framework. The Establishing Ethical Guidelines for Applying AI to IAEA Safeguards project creates awareness in the community of the ethical AIS approach.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Guidelines for Home Energy Professionals

The Guidelines for Home Energy Professionals (GHEP) provide universal resources to support high-quality work and a skilled, credentialed workforce for home energy upgrades. GHEP incorporates input from more than 2,000 home performance industry members and draws on 45 years of U.S. Department of Energy (DOE) weatherization experience to provide a high-quality baseline across states, agencies, employers, employees, and homeowners.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Operating and maintenance guidelines for screenbowl centrifuges

Plant dewatering circuits equipped with screenbowl centrifuges need to be well designed, properly operated, and adequately maintained to maximize the dewatering performance. The most important 'feed variables' are particle size, dry solids feed rate and slurry flow rate. The most important 'machine variables' include pool depth, rotational speed and gearbox ratio. The article discusses the effect of these parameters and offers some maintenance guidelines. The article was adapted from a paper presented at CoalPrep 2008. 6 refs., 2 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Qualifying nuclear graphite components using ASME guidelines

Qualifying nuclear graphite components using ASME guidelines, including Semi-probabilistic, probabilistic, and deterministic approaches to design, theory of methods, pre-assessment analysis inputs, post assessment analysis outputs, simplified assessment, full assessment, and application.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method for Implementing Subsurface Solid Derived Concentration Guideline Levels (DCGL) - 12331

The U.S. Nuclear Regulatory Commission (NRC) and other federal agencies currently approve the Multi-Agency Radiation Site Survey and Investigation Manual (MARSSIM) as guidance for licensees who are conducting final radiological status surveys in support of decommissioning. MARSSIM provides a method to demonstrate compliance with the applicable regulation by comparing residual radioactivity in surface soils with derived concentration guideline levels (DCGLs), but specifically discounts its applicability to subsurface soils. Many sites and facilities undergoing decommissioning contain subsurface soils that are potentially impacted by radiological constituents. In the absence of specific guidance designed to address the derivation of subsurface soil DCGLs and compliance demonstration, decommissioning facilities have attempted to apply DCGLs and final status survey techniques designed specifically for surface soils to subsurface soils. The decision to apply surface soil limits and surface soil compliance metrics to subsurface soils typically results in significant over-excavation with associated cost escalation. MACTEC, Inc. has developed the overarching concepts and principles found in recent NRC decommissioning guidance in NUREG 1757 to establish a functional method to derive dose-based subsurface soil DCGLs. The subsurface soil method developed by MACTEC also establishes a rigorous set of criterion-based data evaluation metrics (with analogs to the MARSSIM methodology) that can be used to demonstrate compliance with the developed subsurface soil DCGLs. The method establishes a continuum of volume factors that relate the size and depth of a volume of subsurface soil having elevated concentrations of residual radioactivity with its ability to produce dose. The method integrates the subsurface soil sampling regime with the derivation of the subsurface soil DCGL such that a self-regulating optimization is naturally sought by both the responsible party and regulator. This paper describes the concepts and basis used by MACTEC to develop the dose-based subsurface soil DCGL method. The paper will show how MACTEC's method can be used to demonstrate that higher concentrations of residual radioactivity in subsurface soils (as compared with surface soils) can meet the NRC's dose-based regulations. MACTEC's method has been used successfully to obtain the NRC's radiological release at a site with known radiological impacts to subsurface soils exceeding the surface soil DCGL, saving both time and cost. Having considered the current NRC guidance for consideration of residual radioactivity in subsurface soils during decommissioning, MACTEC has developed a technically based approach to the derivation of and demonstration of compliance with subsurface soil DCGLs for radionuclides. In fact, the process uses the already accepted concepts and metrics approved for surface soils as the foundation for deriving scaling factors used to calculate subsurface soil DCGLs that are at least equally protective of the decommissioning annual dose standard. Each of the elements identified for consideration in the current NRC guidance is addressed in this proposed method. Additionally, there is considerable conservatism built into the assumptions and techniques used to arrive at subsurface soil scaling factors and DCGLs. The degree of conservatism embodied in the approach used is such that risk managers and decision makers approving and using subsurface soil DCGLs derived in accordance with this method can be confident that the future exposures will be well below permissible and safe levels. The technical basis for the method can be applied to a broad variety of sites with residual radioactivity in subsurface soils. Given the costly nature of soil surveys, excavation, and disposal of soils as low-level radioactive waste, MACTEC's method for deriving and demonstrating compliance with subsurface soil DCGLs offers the possibility of significant cost savings over the traditional approach of applying surface soil DCGLs to subsurface soils. Furthermore, while yet untested, MACTEC believes that the concepts and methods embodied in this approach could readily be applied to other types of contamination found in subsurface soils. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The ultimate response guideline simulation and analysis by using TRACE/FRAPTAN for Chinshan Nuclear Power Plant

TRACE and FRAPTRAN models of Chinshan BWR/4 nuclear power plant (NPP) were established for the ultimate response guideline (URG) simulation and analysis. The depressurization of the reactor, low pressure water injection of the reactor, and containment venting are the main actions of URG. This research focuses to evaluate the URG utility under Fukushima-like conditions. This study consists of three steps. The first step is the establishment of TRACE and FRAPTRAN models. The second step is the URG simulation and analysis under Fukushima-like conditions by using TRACE model. In this step, the no URG case was also performed in order to evaluate the URG effectiveness. Additionally, the sensitivity study of URG and the required raw water injection were performed. The final step is the fuel rod analysis of FRAPTRAN for the above cases. According to TRACE results, the URG can keep the peak cladding temperature (PCT) below the criteria 1088.7 K under Fukushima-like conditions. It indicates that Chinshan NPP can be controlled in a safe situation. If Chinshan NPP does not perform the URG under Fukushima-like conditions, the water level may drop lower than TAF (top of active fuel) which may result in the generation of the safety issue about the fuel rods. FRAPTRAN results depicted that zirconium-water reaction generated in no low pressure water injection cases. It may cause a safety issue in fuel rods. And, the actions of URG affected the performance of fuel rods according to FRAPTRAN results. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of severe accident management guideline (SAMG) entry condition for OPR1000 - 367

The current severe accident prevention and mitigation strategies for OPR 1000 have emergency operating procedures (EOPs) and severe accident management guidelines (SAMGs), respectively. The main objective of SAMG is to prevent a release of radioactive materials from releasing into environment and mitigate severe accident phenomena during severe accident. The current SAMG entry condition is met when the core exit temperature (CET) reaches 650 deg. C in OPR 1000. Peak cladding temperature (PCT), which represents core integrity more precisely than CET does, cannot be used since it is not measurable in the main control room (MCR). Current SAMG entry condition for every kind of accident scenarios is not reasonable, since entry condition is determined without considering operator action time. Therefore, SAMG entry condition need to be verified with consider operator action time. Thus, an analysis methodology for SAMG entry condition was developed to verify the SAMG entry condition. A severe accident DB were also developed in order to analyze the SAMG entry condition. The analysis results of DB show that available operator action time from the SAMG entrance to RV fail is shorter than the required time in most cases. As a result, the proper SAMG entry condition was suggested through the results of DB analysis. When the SAMG entry condition is changed from CET to suggested condition, the available action time is increased about 350 to 4300 sec. Also, the suggested entry condition was verified through the simulation which considered operation action time and reflecting the suggested entry condition. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operational Guidelines for Use of Radiation Portal Monitors in Nuclear Facilities

This article provides guidelines (not requirements) for the testing, operation, and maintenance of radiation portal monitors used to scan pedestrian and vehicular traffic entering or exiting nuclear facilities to prevent unauthorized removal of nuclear material. The intended audience is facility managers, supervisors, and operators who are responsible for establishing and maintaining radiation detection systems, who are likely well acquainted with physical security procedures, but may not have a familiarity with the operation of radiation detection.

Enders, Alexander [Oak Ridge National Laboratory (↗

Antigua and Barbuda Distributed Energy Resources Deployment Guidelines

This document is designed to provide comprehensive considerations, best practices and guidance for deployment of Distributed Energy Resources (DERs) in Antigua and Barbuda. The document provides lists of various technology selection guidance including technical specifications, requirements and applicable key standards and code associated with key DERs and balance of plant equipment. The document also presents the key microgrid design considerations to integrate the DERs to achieve the economic, decarbonization and resiliency goals. Taking into account sensitive grid for such islands, for grid readiness and screening the potential DER interconnection, general approach is highlighted along with the potential technical interconnection requirements. Furthermore, this document shows the key stakeholders involved in such DER integration and/or microgrid project and how key responsible project team can be qualified. Finally, this document refers to key information about warranties and consumer rights and maintenance of the systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Alternative Compliance: Guidelines for Preparing and Submitting a Waiver Request Application and Other Documentation Requirements (Book)

This document is designed to assist covered fleets interested in taking advantage of more flexible compliance options and to facilitate the transition from Standard Compliance to Alternative Compliance. It is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guidelines for Home Energy Professionals Project (Fact Sheet)

The U.S. Department of Energy’s (DOE) Weatherization Assistance Program (WAP) was created in 1976 and has weatherized more than 7.3 million households since its inception. Throughout the years, private industry, public utilities, municipalities, and states have also implemented numerous home energy upgrade programs in the market—making weatherization efforts a staple in their energy efficiency portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guidelines for Home Energy Professionals Project: Multifamily Job Task Analyses Needs Assessment

This report describes the efforts carried out to determine whether there is a need to develop separate, multifamily-specific JTAs for the four proposed job categories. The multifamily SWS market committee considered these job designations to be the best candidates for developing JTAs and certification blueprints, as well as having the greatest potential for promoting job growth in the multifamily home performance industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Compliance: Guidelines for Preparing and Submitting a Waiver Request Application and Other Documentation Requirements

This document is designed to assist covered fleets interested in taking advantage of more flexible compliance options and to facilitate the transition from Standard Compliance to Alternative Compliance. It is designed to help fleets better understand the Alternative Compliance option and successfully complete the waiver application process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RELAP5-3D Developer Guidelines and Programming Practices

Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developer Guidelines and Programming Practices

Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software, the behavior of the RELAP5-3D program that must be maintained, and code testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗