Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Ionizing Radiation from Ex Vivo Sterilization Diminishes Fatigue but Not Static Murine Vertebral Body Mechanics

For a variety of medical and scientific reasons, human bones can be exposed to ionizing radiation. At relatively high doses (30,000±5,000 Gy), ex vivo ionizing radiation is commonly used to sterilize bone allografts. However, ionizing radiation in these applications has been shown to increase risk of fracture clinically and decrease bone quality. Previously, we observed a significant decrease in compressive static strength and fatigue life of ex vivo whole bones exposed to x-ray radiation at 17,000 Gy and above; no changes in compressive mechanical properties were observed for radiation doses of 1,000 Gy and below. The gap in doses between no mechanical change (1,000 Gy) and significant mechanical degradation (17,000 Gy) is large, and it is unclear at what dose mechanical integrity begins to diminish in whole bones, and if its effects differ in response to static versus cyclic mechanical loading. This is a major clinical concern, as trabecular and cortical bone allografts are commonly used in structural, load-bearing applications. To gain insight into the effect of ionizing radiation from 1,000-17,000 Gy, we conducted an ex vivo radiation study on the static and fatigue mechanical properties of the vertebral whole bone. Our objectives were to: (1) quantify the effect of exposure to ex vivo ionizing radiation on the mechanical integrity (compressive static and fatigue) of whole bones; and (2) evaluate, if there are observed differences in mechanics, if they differ in magnitude for static versus cyclic properties. The results of this study will give insight into the need for changes in protocols for bone allograft radiation sterilization procedures.

bone mechanics↗

Bubble Mapping with the Square Kilometre Array - I. Detecting Galaxies with Euclid, JWST, WFIRST, and ELT within Ionized Bubbles in the Intergalactic medium at z > 6

The Square Kilometre Array (SKA) is expected to provide the first tomographic observations of the neutral intergalactic medium at redshifts z > 6 and pinpoint the locations of individual ionized bubbles during early stages of cosmic reionization. In scenarios where star-forming galaxies provide most of the ionizing photons required for cosmic reionization, one expects the first ionized bubbles to be centred on overdensities of such galaxies. Here, we model the properties of galaxy populations within isolated, ionized bubbles that SKA-1 should be able to resolve at z ≈ 7–10, and explore the prospects for galaxy counts within such structures with various upcoming near-infrared telescopes. We find that, for the bubbles that are within reach of SKA-1 tomography, the bubble volume is closely tied to the number of ionizing photons that have escaped from the galaxies within. In the case of galaxy-dominated reionization, galaxies are expected to turn up above the spectroscopic detection threshold of JWST and ELT in even the smallest resolvable bubbles at z ≤ 10. The prospects of detecting galaxies within these structures in purely photometric surveys with Euclid, WFIRST, JWST, or ELT are also discussed. While spectroscopy is preferable towards the end of reionization to provide a robust sample of bubble members, multiband imaging may be a competitive option for bubbles at z ≈ 10, due to the very small number of line-of-sight interlopers expected at these redshifts.

Erik Zackrisson↗

Onset of Cosmic Reionization: Evidence of an Ionized Bubble Merely 680 Myr After the Big Bang

While most of the intergalactic medium (IGM) today is permeated by ionized hydrogen, it was largely filled with neutral hydrogen for the first 700 million years after the big bang. The process that ionized the IGM (cosmic reionization) is expected to be spatially inhomogeneous, with fainter galaxies likely playing a significant role. However, we still have only a few direct constraints on the reionization process. Here we report spectroscopic confirmation of two galaxies and very likely a third galaxy in a group (hereafter EGS77) at redshift z = 7.7, merely 680 Myr after the big bang. The physical separation among the three members is <0.7 Mpc. We estimate the radius of ionized bubble of the brightest galaxy to be about 1.02 Mpc, and show that the individual ionized bubbles formed by all three galaxies likely overlap significantly, forming a large yet localized ionized region, indicative of inhomogeneity in the reionization process. It is striking that two of three galaxies in EGS77 are quite faint in the continuum, thanks to our selection using their Lyα line emission in the narrowband filter. Indeed, one is the faintest spectroscopically confirmed galaxy yet discovered at such high redshifts. Our observations provide direct constraints on the process of cosmic reionization, and allow us to investigate the properties of sources responsible for reionizing the universe.

Reionization↗

Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

Kelly, Ryan T↗

Investigating Enhanced Thorium Ionization in TIMS Using Re/Pt Porous Ion Emitters

Thermal ionization mass spectrometry (TIMS) is a widely used, benchmark method in the isotopic analysis of actinides relevant to various nuclear and geological fields. Despite significant previous use and inherent advantages, however, poor sample ionization continues to hamper the use of TIMS in the measurement of trace species; actinide ionization efficiencies frequently fall below 0.1 % using traditional instrument sources. Factors leading to poor ionization are compounded in the measurement of several highly refractory metals (e.g. U and Th) that may provide key signatures data in non-proliferation, safeguards and forensics efforts. Herein, a relatively new TIMS ion source strategy, employing porous ion emitters (PIEs) atop traditional filament assemblies, is investigated for the first time as a straightforward means of enhancing the ionization of Th, which is arguably a worst case scenario for TIMS-based actinide measurements. These sources yielded up to 410% greater Th sample utilization, relative to previously published values and in-house measurements collected using traditional methods. Accompanying scanning electron microscopy (SEM) investigations provide preliminary insight into possible mechanisms of PIE functioning and explore the impacts that extended heating have on the constructed source’s structure and composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Propagation direction reversal of ionization zones in the transition between high and low current magnetron sputtering

Past research has revealed the propagation of dense, asymmetric ionization zones in both high and low current magnetron discharges. Here we report about the direction reversal of ionization zone propagation as observed with fast cameras. At high currents, zones move in the E B direction with velocities of 103 to 104 m/s. However at lower currents, ionization zones are observed to move in the opposite, the -E B direction, with velocities ~;; 103 m/s. It is proposed that the direction reversal is associated with the local balance of ionization and supply of neutrals in the ionization zone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MICE Demonstration of Ionization Cooling

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions at energies of up to several TeV at the Muon Collider. The International Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization cooling channel, the muon beam passes through a material (the absorber) in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised project plan, which has received the formal endorsement of the international MICE Project Board and the international MICE Funding Agency Committee, will deliver a demonstration of ionization cooling by September 2017. In the revised configuration a central lithium-hydride absorber provides the cooling effect. The magnetic lattice is provided by the two superconducting focus coils and acceleration is provided by two 201 MHz single-cavity modules. The phase space of the muons entering and leaving the cooling cell will be measured by two solenoidal spectrometers. All the superconducting magnets for the ionization cooling demonstration are available at the Rutherford Appleton Laboratory and the first single-cavity prototype is under test in the MuCool Test Area at Fermilab. The design of the cooling demonstration experiment will be described together with a summary of the performance of each of its components. The cooling performance of the revised configuration will also be presented.

43 PARTICLE ACCELERATORS↗

Pre-Ionization Controlled Laser Plasma Formation for Ignition Applications

The presented research explored new physics and ignition schemes based on laser induced plasmas that are fundamentally distinct from past laser ignition research focused on single laser pulses. Specifically, we consider the use of multiple laser pulses where the first pulse provides pre-ionization allowing controlled absorption of the second pulse. In this way, we can form tailored laser plasmas in terms of their ionization fraction, gas temperature (e.g. to achieve elevated temperature of ~2000 K ideally suited for an ignition source), reduced energy loss to shock waves and radiation, and large kernel size (e.g. length ~1-10 cm). The proposed research included both experimental and modeling efforts, at Colorado State University, Princeton University and University of Tennessee, towards the basic science of the new laser plasma approach with emphasis on tailoring the plasmas to practical propulsion systems. Experimental results (CSU) show that the UV beam produces a pre-ionized volume which assists in breakdown of the NIR beam, leading to reduction in NIR breakdown threshold by factor of >2. Numerical modeling is performed to examine the ionization and breakdown of both beams. The main theoretical and computational parts of the work were done at Princeton University. The modeled breakdown threshold of the NIR, including assist by pre-ionization, is in reasonable agreement with the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionizing-radiation beam monitoring system

A transmissive ionizing-radiation beam monitoring system includes an enclosure structure with at least one ultra-thin window to an incident ionizing-radiation beam, where the ultra-thin window is highly transmissive to ionizing-radiation. Embodiments include at least one thin or ultra-thin scintillator within the enclosure structure that is substantially directly in an incident ionizing-radiation beam path and transmissive to the incident radiation beam, and at least one ultraviolet (UV) illumination source within the enclosure structure facing the scintillator. Embodiments include at least one machine vision camera within the enclosure structure located out of an incident ionizing-radiation beam path and including a camera body and lens having a projection of its optical axis oriented at an angle of incidence of 45±35 degrees to a surface of the scintillator.

Friedman, Peter S.↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Disposal of De-ionizer Vessels Highly Contaminated with {sup 14}Carbon at SRS

At the Savannah River Site (SRS), nuclear production reactors used de-ionizers to control the chemistry of the reactor moderator during their operation to produce nuclear materials primarily for the weapons program. These de-ionizers were removed from the reactors and stored as a legacy waste with no path to disposal due to the relatively high {sup 14}C contamination (i.e., on the order of 20 curies per de-ionizer for 48-50 de-ionizers) and the low disposal limit of 4.2 Ci previously established for the Intermediate Level Vault (ILV). The ILV is considered most appropriate facility within which to dispose these items due to the method of solidifying waste items with cementitious material inside concrete vaults. In previous analyses the {sup 14}C ILV disposal limit was established at 4.2 Ci resulting from the use of a very conservative method to analyze the dose received from atmospheric releases of gaseous {sup 14}C. This investigation implemented a more rigorous evaluation of the physical and chemical processes influencing the release and migration of gaseous {sup 14}C (as CO{sub 2}) to obtain a more realistic estimate of atmospheric dose and to determine new ILV disposal limits. The results are in terms of an emanation rate of {sup 14}C activity at the land surface. There is a rapid buildup to the maximum emanation rate of 1.42 E-8 Ci/year within 0.4 years. This rate continues steadily for the remainder of the simulation. The maximum emanation rate was used to calculate the dose to the Maximally Exposed Individual (MEI) at a point 100 m from the ILV, which is the most restrictive exposure point. The dose to the MEI at this location was calculated to be 3.83 E-05 mrem/yr. which is minuscule compared to the exposure limit defined in US DOE Order 435.1 as 10 mrem/yr. Considering the tiny dose to the MEI calculated in this analysis, no atmospheric pathway limit needed to be applied to the Intermediate Level Vault for {sup 14}C. This is justified in that no matter how much {sup 14}C is disposed in the ILV disposal environment, only a set, relatively small quantity can move into the air space as gas due to the solubility control limitation. Consequently, the groundwater pathway disposal limit for resin-based {sup 14}C in the Intermediate Level Vault became the most restrictive limit among the various pathways, this limit being 2.6 E+06 Ci, which easily allows for disposal of all the Reactor Moderator De-ionizers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces

It is well known that the achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. In this report we systematically study the ion transmission and ionization efficiencies in different ESI-MS interface configurations. The configurations under investigation include a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interfaces with a single emitter and an emitter array, respectively. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Our experimental results suggest that the overall ion utilization efficiency in the SPIN-MS interface configurations is better than that in the inlet capillary based ESI-MS interface configurations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced ionization efficiency in TIMS analyses of plutonium and americium using porous ion emitters

Investigations of enhanced sample utilization in thermal ionization mass spectrometry (TIMS) using porous ion emitter (PIE) techniques for the analyses of trace quantities of americium and plutonium were performed. Repeat ionization efficiency (i.e., the ratio of ions detected to atoms loaded on the filament) measurements were conducted on sample sizes ranging from 10–100 pg for americium and 1–100 pg for plutonium using PIE and traditional (i.e., a single, zone-refined rhenium, flat filament ribbon with a carbon ionization enhancer) TIMS filament sources. When compared to traditional filaments, PIEs exhibited an average boost in ionization efficiency of ~550% for plutonium and ~1100% for americium. A maximum average efficiency of 1.09% was observed at a 1 pg plutonium sample loading using PIEs. Supplementary trials were conducted using newly developed platinum PIEs to analyze 10 pg mass loadings of plutonium. As a result, platinum PIEs exhibited an additional ~134% boost in ion yield over standard PIEs and ~736% over traditional filaments at the same sample loading level.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tunnel ionization within a one-dimensional, undriven plasma sheath

In high density, high temperature plasmas, the plasma sheath that develops can result in extremely high electric fields, on the order of tens to hundreds of V/nm. Under the right conditions, these electric fields can reach magnitudes that can increase the probability of electron tunneling ionization to occur, resulting in one or more electron-ion pairs. The presence of tunneling ionization can then modify the development of the plasma sheath, as well as properties such as the ion and electron densities and plasma potential. The tunnel ionization process for hydrogen atoms is demonstrated, in this work, as implemented in a Sandia National Laboratories, particle-in-cell code Aleph. Results are presented for the application of the tunnel ionization process to a one-dimensional, undriven plasma sheath. Additional results for cases that consider warm ions and neutrals, the inclusion of electron–neutral collisions, and the injection of neutral particles, as well as the application to various plasma devices, will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE ROLE OF DIFFUSIVE SHOCK ACCELERATION ON NONEQUILIBRIUM IONIZATION IN SUPERNOVA REMNANT SHOCKS. II. EMITTED SPECTRA

We present a grid of nonequilibrium ionization models for the X-ray spectra from supernova remnants undergoing efficient diffusive shock acceleration. The calculation follows the hydrodynamics of the blast wave as well as the time-dependent ionization of the plasma behind the shock. The ionization state is passed to a plasma emissivity code to compute the thermal X-ray emission, which is combined with the emission from nonthermal synchrotron emission to produce a self-consistent model for the thermal and nonthermal emission from cosmic-ray dominated shocks. We show how plasma diagnostics such as the G'-ratio of He-like ions, defined as the ratio of the sum of the intercombination, forbidden, and satellite lines to the resonance line, can vary with acceleration efficiency, and discuss how the thermal X-ray emission, when the time-dependent ionization is not calculated self-consistently with the hydrodynamics, can differ from the thermal X-ray emission from models which do account for the hydrodynamics. Finally, we compare the thermal X-ray emission from models which show moderate acceleration ({approx}35%) to the thermal X-ray emission from test-particle models.

79 ASTRONOMY AND ASTROPHYSICS↗

Temporal coherent control of resonant two-photon double ionization of the hydrogen molecule via doubly excited states

Here, we use time-delayed, counter-rotating, circularly polarized few-cycle attosecond nonoverlapping pulses to study the temporal coherent control of the resonant process of two-photon double ionization (TPDI) of hydrogen molecule via doubly excited states for pulse propagation direction along $\hat k$ either parallel or perpendicular to the molecular axis $\hat R$. For $\hat k$∥ $\hat R$ and a pulse carrier frequency of 36 eV resonantly populating the Q 2 1 Π$^+_u$ (1) doubly excited state as well as other 1 Π$^+_u$ doubly excited states, we find that the indirect ionization pathway through these doubly excited states changes the character of the kinematical vortex-shaped momentum distribution produced by the two direct ionization pathways from fourfold to twofold rotational symmetry. This result is similar to what found in TPDI of the He atom involving 1 P$^ o_ {±1}$ doubly excited states; however, angular distributions exhibiting a quantum beat effect between the ground state and a doubly excited state seen for the He atom are observed here for its molecular counterpart with an anomaly in shape and magnitude, not in frequency. The sixfold differential probability integrated over the azimuthal angle of the photoelectron pair shows that this anomaly is due to autoionization decays and quantum beats between doubly excited states. For $\hat k$⟂$\hat R$ and a broadband pulse carrier frequency of 30 eV populating the Q 1 1 Π$^+_u$(1), Q 1 1 Σ$^+_u$(1), Q 2 1 Π$^+_u$(1) , and Q 1 1 Σ$^+_u$ (2) doubly excited states, the momentum distribution is shown to exhibit dynamical electron vortices with four spiral arms, which originates from the interplay between the 1 Δ$^+_ g$ , 1 Π$^+_ g$, and 1 Σ$^+_ g$ dynamical ionization amplitudes. Our treatment within either the adiabatic-nuclei approximation or fixed-nuclei approximation shows that the latter provides a very good account for this correlated process.

74 ATOMIC AND MOLECULAR PHYSICS↗