Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

First demonstration of a fiber optic bolometer on a tokamak plasma (invited)

A fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time at the DIII-D tokamak. A FOB uses a fiber optics-based interferometric technique that is designed to have a high sensitivity to temperature changes [75 mK/(W/m2) responsivity in high vacuum with 0.38 mK noise level] with a negligible susceptibility to electromagnetic interference (EMI) that can be problematic for resistive bolometers in a tokamak environment. A single-channel test apparatus was installed on DIII-D consisting of a measurement FOB and shielded reference FOB. The single-channel FOB showed a negligible increase in the noise level during typical plasma operations (0.39 mK) compared to the benchtop results (0.38 mK), confirming an insignificant EMI impact to the FOB. Comparisons to DIII-D resistive bolometers showed good agreement with the single-channel FOB, indicating that the FOB is comparable to a resistive bolometer when the impulse calibration is applied. The noise-equivalent power density of the calibrated FOB during a plasma operation was 0.55 W/m2 with an average sampling time of 20 ms. The major potential effect of ionizing radiation on the FOB would be the radiation-induced attenuation, which can be efficiently compensated for by adjusting the probing light power.

Lee, S. (ORCID:0000000170289004)↗

Collinear dual-pulse laser optical breakdown and energy deposition

A non-equilibrium model for laser-generated plasmas is used to represent collinear dual nano-second-pulse interactions. In the specific case considered, the breakdown is initiated with an ultraviolet (UV) laser pulse at 266 nm, which pre-ionizes the gas, and it is followed by a near-infrared (NIR) pulse at 1064 nm, which deposits significant energy into the ionized mixture. The model is validated against corresponding experiments, and simulation results are interrogated to understand key features of the plasma-kernel dynamics and the post-discharge hydrodynamics. The hydrodynamics of the non-equilibrium plasma is governed by the two-temperature Navier–Stokes equations accounting for both multiphoton ionization and inverse bremsstrahlung. The interaction between the laser beam and the plasma is modeled based on the radiative transfer equation. The temporal and spatial offsets of the two pulses can generate ionization kernels with different topology and dynamics. It is shown that the UV pre-ionization pulse can tailor the plasma region, leading to a larger ionized volume than would occur for a single-pulse breakdown, and it increases the efficiency of the energy deposition for the following NIR discharge. Vorticity in the early post-discharge phase is generated via baroclinic torque from the misalignment of the radial gradient of density (sudden gas expansion) and the strong pressure gradient (initiated by energy deposition from the laser beam). It is predicted that the collinear dual pulse can be designed to specify the plasma kernel size, shape, and maximum temperature in the breakdown phase, and the initial post-breakdown vorticity and plasma-core decay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single Variable and Multivariate Analysis of Remote Laser-Induced Breakdown Spectra for Prediction of Rb, Sr, Cr, Ba, and V in Igneous Rocks

Laser-induced breakdown spectroscopy (LIBS) will be employed by the ChemCam instrument on the Mars Science Laboratory rover Curiosity to obtain UV, VIS, and VNIR atomic emission spectra of surface rocks and soils. LIBS quantitative analysis is complicated by chemical matrix effects related to abundances of neutral and ionized species in the resultant plasma, collisional interactions within plasma, laser-to-sample coupling efficiency, and self-absorption. Atmospheric composition and pressure also influence the intensity of LIBS plasma. These chemical matrix effects influence the ratio of intensity or area of a given emission line to the abundance of the element producing that line. To compensate for these complications, multivariate techniques, specifically partial least-squares regression (PLS), have been utilized to predict major element compositions (>1 wt.% oxide) of rocks, PLS methods regress one or multiple response variables (elemental concentrations) against multiple explanatory variables (intensity at each pixel of the spectrometers). Because PLS utilizes all available explanatory variable and eliminates multicollinearity, it generally performs better than univariate methods for prediction of major elements. However, peaks arising from emissions from trace elements may be masked by peaks of higher intensities from major elements. Thus in PLS regression, wherein a correlation coefficient is determined for each elemental concentration at each spectrometer pixel, trace elements may show high correlation with more intense lines resulting from optical emissions of other elements. This could result in error in predictions of trace element concentrations. Here, results of simple linear regression (SLR) and multivariate PLS-2 regression for determination of trace Rb, Sr, Cr, Ba, and V in igneous rock samples are compared. This study focuses on comparisons using only line intensities rather than peak areas to highlight differences between SLR and PLS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time Correlation Measurements of 252Cf Source Driven Fission Chains in Bare HEU Metal Assemblies

Passive multiplicity measurements of fissile metal assemblies are well established for measuring the multiplication, fissile content, and detection efficiency. In plutonium metal assemblies, most of the neutrons are unambiguously observed from fission chains because of the high spontaneous fission rate. However, uranium metal assemblies have low spontaneous fission rate such that the observed neutrons are a mixture of fission chain neutrons and cosmic-ray spallation neutrons. As a result, the multiplication, fissile content, and detection efficiency are difficult to measure without accurate quantification of the single neutron events unrelated to the fission chains. However, studying fission chains is simplified by knowing when each chain starts, which can be accomplished using a time-tagged active source such as a 252 Cf ionization chamber or a deuterium-tritium (D-T) neutron generator with an alpha detector. This paper presents time correlation measurements that have been performed with up to five 18 kg highly enriched uranium (HEU) storage castings and a 252 Cf ionization chamber placed near the center of each assembly. The measurements included liquid scintillators with pulse shape discrimination operating on the timescale of fission chains and 3 He proportional counters whose traditional use in multiplicity counting is well understood within a point-kinetics framework. Neutron time correlation distributions have been measured to characterize each assembly and are compared with the equivalent distributions collected passively.

252-Cf Ionization Chamber↗

Femtosecond response of polyatomic molecules to ultra-intense hard X-rays

We report x-ray free-electron lasers enable the investigation of the structure and dynamics of diverse systems, including atoms, molecules, nanocrystals and single bioparticles, under extreme conditions. Many imaging applications that target biological systems and complex materials use hard X-ray pulses with extremely high peak intensities (exceeding 10 20 watts per square centimetre). However, fundamental investigations have focused mainly on the individual response of atoms and small molecules using soft X-rays with much lower intensities. Studies with intense X-ray pulses have shown that irradiated atoms reach a very high degree of ionization, owing to multiphoton absorption, which in a heteronuclear molecular system occurs predominantly locally on a heavy atom (provided that the absorption cross-section of the heavy atom is considerably larger than those of its neighbours) and is followed by efficient redistribution of the induced charge. In serial femtosecond crystallography of biological objects—an application of X-ray free-electron lasers that greatly enhances our ability to determine protein structure—the ionization of heavy atoms increases the local radiation damage that is seen in the diffraction patterns of these objects and has been suggested as a way of phasing the diffraction data. On the basis of experiments using either soft or less-intense hard X-rays, it is thought that the induced charge and associated radiation damage of atoms in polyatomic molecules can be inferred from the charge that is induced in an isolated atom under otherwise comparable irradiation conditions. Here we show that the femtosecond response of small polyatomic molecules that contain one heavy atom to ultra-intense (with intensities approaching 10 20 watts per square centimetre), hard (with photon energies of 8.3 kiloelectronvolts) X-ray pulses is qualitatively different: our experimental and modelling results establish that, under these conditions, the ionization of a molecule is considerably enhanced compared to that of an individual heavy atom with the same absorption cross-section. This enhancement is driven by ultrafast charge transfer within the molecule, which refills the core holes that are created in the heavy atom, providing further targets for inner-shell ionization and resulting in the emission of more than 50 electrons during the X-ray pulse. Fnally, our results demonstrate that efficient modelling of X-ray-driven processes in complex systems at ultrahigh intensities is feasible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultra-intense femtosecond laser interactions with aligned nanostructures

The interaction of ultrafast laser pulses of relativistic intensity with high aspect ratio nanostructures can efficiently and volumetrically heat matter to an ultra-high-energy-density regime encountered in the center of stars and within the core of fusion capsules compressed by the world’s largest lasers. It also generates gigantic quasi-static electromagnetic fields that accelerate particles to very high energy. Here, we present an overview of the physics and applications of these dense relativistic plasmas that can be created with pulses of relatively modest energy from lasers that can operate at a high repetition rate. Recent nanowire array experiments produced near-solid density plasmas with an extreme degree of ionization (e.g., Au +72 ), converted ultrafast pulses of laser light into intense x-ray flashes with record efficiency, and accelerated ions to MeV energies, efficiently driving micro-scale fusion reactions that generate flashes of quasi-monoenergetic neutrons. These plasmas also serve as a platform for advancing the understanding of atomic processes in extreme environments and open a new pathway to laser-driven fusion energy. The irradiation of nanostructures at intensities of > 1 x 10 22 W cm –2 is predicted to lead to an extreme ultra-high energy density plasma regime characterized by terabar pressures that is virtually unexplored.

Optics↗

Mixing between high velocity clouds and the galactic halo

In the Galactic halo, metal-bearing Galactic halo material mixes into high velocity clouds (HVCs) as they hydrodynamically interact. This interaction begins long before the clouds completely dissipate and long before they slow to the velocity of the Galactic material. In order to make quantitative estimates of the mixing efficiency and resulting metal enrichment of HVCs, we made detailed two- and three-dimensional simulations of cloud-interstellar medium interactions. Our simulations track the hydrodynamics and time-dependent ionization levels. They assume that the cloud originally has a warm temperature and extremely low metallicity while the surrounding medium has a high temperature, low density, and substantial metallicity, but our simulations can be generalized to other choices of initial metallicities. In our simulations, mixing between cloud and halo gas noticeably raises the metallicity of the high velocity material. We present plots of the mixing efficiency and metal enrichment as a function of time.

79 ASTRONOMY AND ASTROPHYSICS↗

An evolutionary model for collapsing molecular clouds and their star formation activity. II. Mass dependence of the star formation rate

We discuss the evolution and dependence on cloud mass of the star formation rate (SFR) and efficiency (SFE) of star-forming molecular clouds (MCs) within the scenario that clouds are undergoing global collapse and that the SFR is controlled by ionization feedback. We find that low-mass clouds (M {sub max} ≲ 10{sup 4} M {sub ☉}) spend most of their evolution at low SFRs, but end their lives with a mini-burst, reaching a peak SFR ∼10{sup 4} M {sub ☉} Myr{sup –1}, although their time-averaged SFR is only (SFR) ∼ 10{sup 2} M {sub ☉} Myr{sup –1}. The corresponding efficiencies are SFE{sub final} ≲ 60% and (SFE) ≲ 1%. For more massive clouds (M {sub max} ≳ 10{sup 5} M {sub ☉}), the SFR first increases and then reaches a plateau because the clouds are influenced by stellar feedback since earlier in their evolution. As a function of cloud mass, (SFR) and (SFE) are well represented by the fits (SFR) ≈ 100(1 + M {sub max}/1.4 × 10{sup 5} M {sub ☉}){sup 1.68} M {sub ☉} Myr{sup –1} and (SFE) ≈ 0.03(M {sub max}/2.5 × 10{sup 5} M {sub ☉}){sup 0.33}, respectively. Moreover, the SFR of our model clouds follows closely the SFR-dense gas mass relation recently found by Lada et al. during the epoch when their instantaneous SFEs are comparable to those of the clouds considered by those authors. Collectively, a Monte Carlo integration of the model-predicted SFR(M) over a Galactic giant molecular cloud mass spectrum yields values for the total Galactic SFR that are within half an order of magnitude of the relation obtained by Gao and Solomon. Our results support the scenario that star-forming MCs may be in global gravitational collapse and that the low observed values of the SFR and SFE are a result of the interruption of each SF episode, caused primarily by the ionizing feedback from massive stars.

79 ASTRONOMY AND ASTROPHYSICS↗

AN EVOLUTIONARY MODEL FOR COLLAPSING MOLECULAR CLOUDS AND THEIR STAR FORMATION ACTIVITY

We present an idealized, semi-empirical model for the evolution of gravitationally contracting molecular clouds (MCs) and their star formation rate (SFR) and efficiency (SFE). The model assumes that the instantaneous SFR is given by the mass above a certain density threshold divided by its free-fall time. The instantaneous number of massive stars is computed assuming a Kroupa initial mass function. These stars feed back on the cloud through ionizing radiation, eroding it. The main controlling parameter of the evolution turns out to be the maximum cloud mass, M{sub max}. This allows us to compare various properties of the model clouds against their observational counterparts. A giant molecular cloud (GMC) model (M{sub max} {approx} 10{sup 5} M{sub Sun }) adheres very well to the evolutionary scenario recently inferred by Kawamura et al. for GMCs in the Large Magellanic Cloud. A model cloud with M{sub max} Almost-Equal-To 2000 M{sub Sun} evolves in the Kennicutt-Schmidt diagram, first passing through the locus of typical low-to-intermediate-mass star-forming clouds, and then moving toward the locus of high-mass star-forming ones over the course of {approx}10 Myr. Also, the stellar age histograms for this cloud a few Myr before its destruction agree very well with those observed in the {rho}-Oph stellar association, whose parent cloud has a similar mass, and imply that the SFR of the clouds increases with time. Our model thus agrees well with various observed properties of star-forming MCs, suggesting that the scenario of gravitationally collapsing MCs, with their SFR regulated by stellar feedback, is entirely feasible and in agreement with key observed properties of MCs.

79 ASTRONOMY AND ASTROPHYSICS↗

Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R{sup 2} = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-286: Dose Verification of Spot-Scanning Proton Beam Using GafChromic EBT3 Film

Purpose: Dose verification of spot-scanning proton pencil beam is performed via planar dose measurements at several depths using an ionization-chamber array, requiring repeat irradiations of each field for each depth. Here we investigate film dosimetry which has two advantages: higher resolution and efficiency from one-shot irradiation for multiple depths. Methods: Film calibration was performed using an EBT3 film at 20-cm depth of Plastic Water (CIRS, Norfolk, VA) exposed by a 10-level step wedge on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged from 25–250 cGy(RBE) for proton energies of 170–200 MeV. A uniform 1000 cm{sup 3} dose cube and a clinical prostate combined with seminal-vesicle and pelvic-nodes plan were used for this study. All treatment plans were generated in the RayStation (RaySearch Lab, Sweden). The planar doses at different depths for both cases were measured with film using triple-channel dosimetry and the MatriXX PT (IBA Dosimetry, Germany). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film and MatriXX, versus treatment planning system (TPS) calculations were analyzed and compared using the FilmQA Pro (Ashland Inc., Bridgewater, NJ). Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate >95% for 2%/2mm and are comparable with the MatriXX measurements (0.7%, 1.8%, 3.8% mean differences corresponding to 3%/3mm, 3%/2mm, 2%/2mm, respectively). Overall passing rates for EBT3 films appear higher than those with MatriXX detectors. Conclusion: The energy dependence of the film response could be minimized by calibration using proton beam with mixed energies. The greater efficiency of the dose verification using GafChromic EBT3 results in a potential cost trade-off between room capacity and film cost. EBT3 film may offer distinct advantages in highly intensity-modulated fields due to its higher resolution compared to 2D ionization-chamber array detectors. One of the authors has a research grant from Ashland Inc., the manufacturer of GafChromic film.

60 APPLIED LIFE SCIENCES↗

Using GC-FID to Quantify the Removal of 4-sec-Butylphenol from NGS Solvent by NaOH

A caustic wash of the solvent used in the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process was found to remove the modifier breakdown product 4-sec-butylphenol (SBP) with varying efficiency depending on the aqueous NaOH concentration. Recent efforts at ORNL have aimed at characterizing the flowsheet chemistry and reducing the technical uncertainties of the NG-CSSX process. One technical uncertainty has been the efficacy of caustic washing of the solvent for the removal of lipophilic anions, in particular, the efficient removal of SBP, an important degradation product of the solvent modifier, Cs-7SB. In order to make this determination, it was necessary to develop a sensitive and reliable analytical technique for the detection and quantitation of SBP. This report recounts the development of a GC-FID-based (Gas Chromatography Flame Ionization Detection) technique for analyzing SBP and the utilization of the technique to subsequently confirm the ability of the caustic wash to efficiently remove SBP from the Next Generation Solvent (NGS) used in NG-CSSX. In particular, the developed technique was used to monitor the amount of SBP removed from a simple solvent and the full NGS by contact with sodium hydroxide wash solutions over a range of concentrations. The results show that caustic washing removes SBP with effectively the same efficiency as it did in the original Caustic-Side Solvent Extraction (CSSX) process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong-field ionization and gauge dependence of nonlocal potentials

Nonlocal potential models have been used in place of the Coulomb potential in the Schrödinger equation as an efficient means of exploring high-field laser-atom interaction in previous works. Although these models have found use in modeling phenomena including photoionization and ejected electron momentum spectra, they are known to break electromagnetic gauge invariance. This paper examines if there is a preferred gauge for the linear field response and photoionization characteristics of nonlocal atomic binding potentials in the length and velocity gauges. Overall, it is found that the length gauge is preferable for a wide range of parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

{sup 6}LiF:ZnS(Ag) Neutrons Scintillator Detector Configuration for Optimal Readout

A Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is under development at the NIST Center for Neutron Research (NCNR). The CANDOR neutron sensor will rely on scintillator material for detecting the neutrons scattered by the sample under test. It consists of {sup 6}LiF:ZnS(Ag) scintillator material into which wavelength shifting (WLS) fibers have been embedded. Solid state photo-sensors (silicon photomultipliers) coupled to the WLS fibers are used to detect the light produced by the neutron capture event ({sup 6}Li (n,α) {sup 3}H reaction) and ionization of the ZnS(Ag). This detector configuration has the potential to accomplish the CANDOR performance requirements for efficiency of 90% for 5 A (3.35 meV) neutrons with high gamma rejection (10{sup 7}) along with compact design, affordable cost and materials availability. However this novel design includes challenges for precise neutron detection. The recognizing of the neutron signature versus the noise event produce by gamma event cannot be easy overcome by pulse height discrimination obstacle as can be achieved with {sup 3}He gas tube. Furthermore the selection of silicon photomultipliers (SiPM) as the light sensor maintains the obstacle of dark noise that does not exist when a photomultiplier tube is coupled to the scintillator. A proper selection of SiPM should focus on increasing the output signal and reducing the dark noise in order to optimize the detection sensitivity and to provide a clean signal pulse shape discrimination. The main parameters for evaluation are: - Quantum Efficiency (QE) - matching the SiPM peak QE with the peak transmission wavelength emission of the WLS. - Recovery time - a short recovery time is preferred to minimize the pulse width beyond the intrinsic decay time of the scintillator crystal (improves the gamma rejection based output pulse shape (time)). - Diode dimensions -The dark noise is proportional to the diode active area while the signal is provided by the WLS fibers; therefore the diode area should ideally be only minimally larger than fiber bundle area. - Low dark noise - it is desirable to minimize the dark noise during the pulse integration period so as to minimize the background for pulse shape discrimination. - Photon Detection Efficiency - it is desirable to increase the SiPM PDE in order to enhance light collection. This will increase the likelihood of detecting neutron events with lower light production and will present a cleaner raw signal for pulse shape discrimination. We will present the SiPM optimization process and studies of dark noise and gamma and neutron sensitivity as a function of bias voltage and operating temperature that have enabled us to optimize the detector sensitivity and gamma rejection. The gamma rejection performance goal requires to overcome the challenge of discriminating between the light signature accepted by neutron event to the one received by the noise. In addition there is a huge variation between the number of light photons that reaching the WLS fibers for different neutron events caused by the heavy ions energy losses prior to ionizing the ZnS(Ag) and the high light attenuation of the scintillation mixture. This variation in the light signal along with the long decay time of the ZnS(Ag) (tens of microseconds) can cause double counting of the same neutron event in the case of high light output signature or preventing the detection of low sequential light output signature neutron event. We will presents the algorithm developed for {sup 6}LiF:ZnS(Ag) sensor readout and the results achieved by an off-line analysis by Matlab software code that successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of LHCD edge power deposition through modulation techniques on Alcator C-Mod

The efficiency of LHCD on Alcator C-Mod drops exponentially with line average density. At reactor relevant densities (> 1 · 1020 [m{sup −3}]) no measurable current is driven. While a number of causes have been suggested, no specific mechanism has been shown to be responsible for the loss of current drive at high density. Fast modulation of the LH power was used to isolate and quantify the LHCD deposition within the plasma. Measurements from these plasmas provide unique evidence for determining a root cause. Modulation of LH power in steady plasmas exhibited no correlated change in the core temperature. A correlated, prompt response in the edge suggests that the loss in efficiency is related to a edge absorption mechanism. This follows previous results which found the generation of n{sub ||}-independent SOL currents. Multiple Langmuir probe array measurements of the conducted heat conclude that the lost power is deposited near the last closed flux surface. The heat flux induced by LH waves onto the outer divertor is calculated. Changes in the neutral pressure, ionization and hard X-ray emission at high density highlight the importance of the active divertor in the loss of efficiency. Results of this study implicate a mechanism which may occur over multiple passes, leading to power absorption near the LCFS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon Regeneration Experiment for Axion Search Using X-Rays

In this Letter we describe our novel photon regeneration experiment for the axionlike particle search using an x-ray beam with a photon energy of 50.2 and 90.7 keV, two superconducting magnets of 3 T, and a Ge detector with a high quantum efficiency. A counting rate of regenerated photons compatible with zero has been measured. The corresponding limits on the pseudoscalar axionlike particle-two-photon coupling constant is obtained as a function of the particle mass. Our setup widens the energy window of purely terrestrial experiments devoted to the axionlike particle search by coupling to two photons. It also opens a new domain of experimental investigation of photon propagation in magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recirculating Linac Acceleration - End-to-End Simulation

A conceptual design of a high-pass-number Recirculating Linear Accelerator (RLA) for muons is presented. The scheme involves three superconducting linacs (201 MHz): a single pass linear Pre-accelerator followed by a pair multi-pass (4.5-pass)'Dogbone' RLAs. Acceleration starts after ionization cooling at 220 MeV/c and proceeds to 12.6 GeV. The Pre-accelerator captures a large muon phase space and accelerates muons to relativistic energies, while adiabatically decreasing the phase-space volume, so that effective acceleration in the RLA is possible. The RLA further compresses and shapes up the longitudinal and transverse phase-spaces, while increasing the energy. Appropriate choice of multi-pass linac optics based on FODO focusing assures large number of passes in the RLA. The proposed 'Dogbone' configuration facilitates simultaneous acceleration of both mu{sup +}- species through the requirement of mirror symmetric optics of the return 'droplet' arcs. Finally, presented end-to-end simulation validates the efficiency and acceptance of the accelerator system.

43 PARTICLE ACCELERATORS↗

A SUZAKU OBSERVATION OF MCG -2-58-22: CONSTRAINING THE GEOMETRY OF THE CIRCUMNUCLEAR MATERIAL

We have analyzed a long-look Suzaku observation of the active galactic nucleus MCG -2-58-22, a type 1.5 Seyfert with very little X-ray absorption in the line of sight and prominent features arising from reflection off circumnuclear material: the Fe line and Compton reflection hump. We place tight constraints on the power-law photon index ({Gamma} = 1.80 {+-} 0.02), the Compton reflection strength (R = 0.69 {+-} 0.05), and the Fe K emission line energy centroid and width (E = 6.40 {+-} 0.02 keV, v{sub FWHM} < 7100 km s{sup -1}). We find no significant evidence either for emission from strongly ionized Fe, or for a strong, relativistically broadened Fe line, indicating that perhaps there is no radiatively efficient accretion disk very close in to the central black hole. In addition, we test a new self-consistent physical model from Murphy and Yaqoob, the 'MYTORUS' model, consisting of a donut-shaped torus of material surrounding the central illuminating source and producing both the Compton hump and the Fe K line emission. From the application of this model we find that the observed spectrum is consistent with a Compton-thick torus of material (column density N{sub H} = 3.6{sup +1.3}{sub -0.8} x 10{sup 24} cm{sup -2}) lying outside of the line of sight to the nucleus, leaving it bare of X-ray absorption in excess of the Galactic column. We calculate that this material is sufficient to produce all of the Fe line flux without the need for any flux contribution from additional Compton-thin circumnuclear material.

79 ASTRONOMY AND ASTROPHYSICS↗