Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Carrier-specific dynamics in 2H-MoTe2 observed by femtosecond soft x-ray absorption spectroscopy using an x-ray free-electron laser

Femtosecond carrier dynamics in layered 2H-MoTe2 semiconductor crystals have been investigated using soft x-ray transient absorption spectroscopy at the x-ray free-electron laser (XFEL) of the Pohang Accelerator Laboratory. Following above-bandgap optical excitation of 2H-MoTe2, the photoexcited hole distribution is directly probed via short-lived transitions from the Te 3d5/2 core level (M5-edge, 572–577 eV) to transiently unoccupied states in the valence band. The optically excited electrons are separately probed via the reduced absorption probability at the Te M5-edge involving partially occupied states of the conduction band. A 400 ± 110 fs delay is observed between this transient electron signal near the conduction band minimum compared to higher-lying states within the conduction band, which we assign to hot electron relaxation. Additionally, the transient absorption signals below and above the Te M5 edge, assigned to photoexcited holes and electrons, respectively, are observed to decay concomitantly on a 1–2 ps timescale, which is interpreted as electron–hole recombination. The present work provides a benchmark for applications of XFELs for soft x-ray absorption studies of carrier-specific dynamics in semiconductors, and future opportunities enabled by this method are discussed.

2D materials↗

High Refractive Index Adhesives for Laser Glass Cladding Applications (ABBREVIATED Report)

To eliminate parasitic light oscillations (amplified spontaneous emission (ASE)), high energy laser systems often utilize polymeric materials to adhere optically absorptive cladding materials to laser gain media (glass or crystal). Most of these polymeric optical adhesives are index matched to lower index gain media, and there was no capability to achieve refractive indices (RI) greater than 1.60 with low color, while also maintaining mechanical compliance to serve as adhesives for cladding applications. The completion of LDRD 23-FS-043 shows we can chemically develop novel suitable adhesive candidates with refractive indices above 1.64 at 532 nm while also exhibiting Shore A hardness between 50-90, with high optical clarity, low color, and minimal haze for films ~1-2 mm thick (84 %Transmission at 532 nm). This will enable us to begin mapping a process space to allow future customizable adhesive formulations for building a variety of laser systems with tunable refractive index matching for various gain and cladding media.

36 MATERIALS SCIENCE↗

Preliminary Results of Solid Gas Generator Micropropulsion

A decomposing solid thruster concept, which creates a more benign thermal and chemical environment than solid propellant combustion, while maintaining, performance similar to solid combustion, is described. A Micro-Electro-Mechanical (MEMS) thruster concept with diode laser and fiber-optic initiation is proposed, and thruster components fabricated with MEMS technology are presented. A high nitrogen content solid gas generator compound is evaluated and tested in a conventional axisymmetric thrust chamber with nozzle throat area ratio of 100. Results show incomplete decomposition of this compound in both low pressure (1 kPa) and high pressure (1 MPa) environments, with decomposition of up to 80% of the original mass. Chamber pressures of 1.1 MPa were obtained, with maximum calculated thrust of approximately 2.7 N. Resistively heated wires and resistively heated walls were used to initiate decomposition. Initiation tests using available lasers were unsuccessful, but infrared spectra of the compound show that the laser initiation tests used inappropriate wavelengths for optimal propellant absorption. Optimal wavelengths for laser ignition were identified. Data presented are from tests currently in progress. Alternative solid gas generator compounds are being evaluated for future tests.

deGroot, Wilhelmus A.↗

Online monitoring of lanthanide species with combined spectroscopy in flowing aqueous aerosol systems

Combined spectroscopic analysis through absorption and laser-induced breakdown spectroscopy (LIBS) was used to monitor Nd and Pr concentrations in a flowing aqueous system. A unique, online sampling approach was employed that allowed for an approximately closed analysis loop of liquids from a reservoir. Absorption spectroscopy was performed with an optical flow cell, and LIBS was performed on an aerosol stream. Multivariate calibrations based on combined absorption and LIBS signals were built for Nd and Pr and then used to monitor concentrations in mixed solutions in a series of spiking tests. In these tests, the concentrations of Nd and Pr in solution were intermittently changed while spectroscopic signals were monitored in real-time. The combined spectroscopic signals and multivariate models were successful in monitoring changing concentrations of lanthanide species with high accuracy and minimal latency. Root-mean squared error of predictions were 0.015 mol L −1 and 0.019 mol L −1 for Nd and Pr respectively, and these lanthanides were able to be monitored to an accuracy of < 0.2 wt%. This work demonstrates both the capabilities of a sampling system for online analysis of liquids and the capabilities of multimodal spectroscopic characterization for real-time, continuous tracking of species in potentially hazardous liquid systems.

absorbance spectroscopy↗

Real-time atmospheric absorption spectra for in-flight tuning of an airborne dial system

Real-time measurements of atmospheric absorption spectra are displayed and used to precisely calibrate and fix the frequency of an Alexandrite laser to specific oxygen absorption features for airborne Differential Absorption Lidar (DIAL) measurements of atmospheric pressure and temperature. The DIAL system used contains two narrowband tunable Alexandrite lasers: one is electronically scanned to tune to oxygen absorption features for on-line signals while the second is used to obtain off-line (nonabsorbed) atmospheric return signals. The lidar operator may select the number of shots to be averaged, the altitude, and altitude interval over which the signals are averaged using single key stroke commands. The operator also determines exactly which oxygen absorption lines are scanned by comparing the line spacings and relative strengths with known line parameters, thus calibrating the laser wavelength readout. The system was used successfully to measure the atmospheric pressure profile on the first flights of this lidar, November 20, and December 9, 1985, aboard the NASA Wallops Electra aircraft.

Dombrowski, M.↗

CO2 DIAL measurements of water vapor

CO2 lidars have heretofore been used to measure water vapor concentrations primarily using the 10R(20) line at 10.247 microns, which has a strong overlap with a water vapor absorption line. This paper discusses the use of that line as well as other CO2 laser lines for which the absorption coefficients are weaker. The literature on measurement of water vapor absorption coefficients using CO2 lasers is reviewed, and the results from four laboratories are shown to be generally consistent with each other after they are normalized to the same partial pressure, temperature, and ethylene absorption coefficent for the 10P(14) CO2 laser line; however, the agreement with the Air Force Geophysics Laboratory's HITRAN and FASCOD 2 spectral data tapes is not good either for the water vapor absorption lines or for the water vapor continuum. Demonstration measurements of atmospheric water vapor have been conducted using the Mobile Atmospheric Pollutant Mapping System, a dual CO2 lidar system using heterodyne detection. Results are discussed for measurements using three sets of laser line pairs covering a wide range of water vapor partial pressures.

Grant, William B.↗

DACOM - A rapid, high sensitivity airborne carbon monoxide monitor

A rapid, high sensitivity differential absorption carbon monoxide monitor (DACOM) has been developed to measure CO from an aircraft. The differential absorption measurement is accomplished by rapidly current tuning the wavelength of a PbSSe diode laser across a single 4.7 micron CO absorption line. As the laser wavelength sweeps periodically across the absorption line, the laser beam is amplitude modulated and is then synchronously detected. With this technique a minimum detectable differential transmission of 0.02% is obtained for a 1 second integration time. This performance is equivalent to a CO sensitivity of 5 ppb for a 10 meter absorption path. The techniques used to achieve this high sensitivity will be discussed. In the aircraft installation a 10 meter absorption path is located in the airstream along the fuselage of a C-54 aircraft. During flight tests of DACOM, a sensitivity of 20 ppb for a 1-second integration time has been achieved.

Sachse, G. W.↗

Ellipsometric study of YBa2Cu3O(7-x) laser ablated and co-evaporated films

High temperature superconducting films of YBa2Cu3O(7-x) (YBCO were grown on SrTiO3, LaA1O3, and YSZ substrates using two techniques: excimer laser ablation with in situ annealing and co-evaporation of Y, Cu, and BaF2 with ex-situ annealing. Film thicknesses were typically 5000 A, with predominant c-axis alignment perpendicular to the substrate. Critical temperatures up to Tc(R=O)=90 K were achieved by both techniques. Ellipsometric measurements were taken in the range 1.6 to 4.3 eV using a variable angle spectroscopic ellipsometer. The complex dielectric function of the laser ablated films was reproducible from run to run, and was found to be within 10 percent of that previously reported for (001) oriented single crystals. A dielectric overlayer was observed in these films, with an index of refraction of approximately 1.55 and nearly zero absorption. For the laser ablated films the optical properties were essentially independent of substrate material. The magnitude of the dielectric function obtained for the co-evaported films was much lower than the value reported for single crystals, and was sample dependent.

Alterovitz, S. A.↗

Ellipsometric study of YBa2Cu3O(7-x) laser ablated and co-evaporated films

High temperature superconducting films of YBa2Cu3O(7-x) (YBCO) were grown on SrTiO3, LaAl03, and YSZ substrates using two techniques: excimer laser ablation with in situ annealing and co-evaporation of Y, Cu, and BaF2 with ex-situ annealing. Film thicknesses were typically 5000 A, with predominant c-axis alignment perpendicular to the substrate. Critical temperatures up to Tc(R = 0) = 90 K were achieved by both techniques. Ellipsometric measurements were taken in the range 1.6 to 4.3 eV using a variable angle spectroscopic ellipsometer. The complex dielectric function of the laser ablated films was reproducible from run to run, and was found to be within 10 percent of that previously reported for (001) oriented single crystals. A dielectric overlayer was observed in these films, with an index of refraction of approximately 1.55 and nearly zero absorption. For the laser ablated films the optical properties were essentially independent of substrate material. The magnitude of the dielectric function obtained for the co-evaporated films was much lower than the value reported for single crystals, and was sample dependent.

Alterovitz, S. A.↗

A tunable dual frequency dye laser - dual frequency oscillator design

The pulsed dye laser offers a tunable oscillator, followed by three amplifiers. It is pumped by a dual frequency Nd:YAG laser. Tuning and spectral width are controlled by a holographic network connected to a high power telescope. The modified two wavelength dye laser allows for absorption lidar techniques for remote sensing of the atmosphere. Line switching is achieved by electrooptical commutation. A feasibility experiment was performed with the original oscillator. A model was then built, and tested with different dyes. After a few modifications were made to improve the conversion efficiency, this oscillator was inserted in the laser to check whether the amplifier stages were correctly adjusted.

Abury, Y.↗

Stationary Bragg reflection of laser light in inhomogeneous absorbing plasmas inside inertial confinement fusion Hohlraums

Laser-produced plasma in inertial confinement fusion (ICF) Hohlraums are marked with density non-uniformity whose length scale can go down to micrometers. This scale is of the order of the laser wavelength. The WKB approximation, which is classically used in radiation-hydrodynamic codes to compute the laser trajectory, cannot correctly take into account such small-scale inhomogeneity of the plasma. Going beyond this approximation, we predict a novel mechanism for the laser reflection. Here we show that an electromagnetic plane wave with wave number k resonates with the k B =2 k Fourier component of a multimode perturbation of the background density and generates a reflected wave. It is the first time that this reflection is considered for stationary inhomogeneous ICF plasmas, and the energy absorption is taken into account. This mechanism, which is a form of Bragg reflection, can occur away from the critical surface and generate a drift of the location of the laser absorption. Furthermore, this absorption will be periodically modulated with a k B wave number. The stationary Bragg reflection can explain ongoing discrepancies between experimental and numerical data about laser trajectory and absorption in ICF Hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Saturation Phenomena in LIF Measurements, Appendix B

Optical saturation is the phenomenon in which the laser-induced rates of absorption and spontaneous emission between two levels, induced by a laser, become comparable to or greater than the spontaneous emission and collision rates connecting these levels. This results in the excited state population N(u) acquiring a value of similar magnitude to that of the ground state, N(e). Under these conditions the observed fluorescence signal, which is proportional to N(u), is no longer linearly dependent on laser intensity I, but increases at a slower rate, and in principle ultimately becomes independent of I. A conceptual picture of optical saturation using a two-level picture is described. This is, however, inadequate for the description of a real experiment involving a molecule, such as OH, for several reasons, which will be explained briefly; these are the multi-level nature of the electronic states and energy transfer among them and effects due to spatial, spectral, and temporal fluctuations in the laser pulse.

Source record↗

A Compact Ti:Sapphire Laser With its Third Harmonic Generation (THG) for an Airborne Ozone Differential Absorption Lidar (DIAL) Transmitter

A compact and high-pulse-energy Ti:Sapphire laser with its Third Harmonic Generation (THG) has been developed for an airborne ozone differential absorption lidar (DIAL) to study the distributions and concentrations of the ozone throughout the troposphere. The Ti:Sapphire laser, pumped by a frequency-doubled Nd:YAG laser and seeded by a single mode diode laser, is operated either at 867 nm or at 900 nm with a pulse repetition frequency of 20 Hz. High energy laser pulses (more than 110 mJ/pulse) at 867 nm or 900 nm with a desired beam quality have been achieved and utilized to generate its third harmonic at 289nm or 300nm, which are on-line and off-line wavelengths of an airborne ozone DIAL. After being experimentally compared with Beta-Barium Borate (beta - BaB2O4 or BBO) nonlinear crystals, two Lithium Triborate (LBO) crystals (5 x 5 x 20 cu mm) are selected for the Third Harmonic Generation (THG). In this paper, we report the Ti:Sapphire laser at 900 nm and its third harmonic at 300 nm. The desired high ultraviolet (UV) output pulse energy is more than 30 mJ at 300 nm and the energy conversion efficiency from 900 nm to 300 nm is 30%.

Chen, Songsheng↗

Atmospheric transmission of CO2 laser radiation with application to laser Doppler systems

The molecular absorption coefficients of carbon dioxide, water vapor, and nitrous oxide are calculated at the P16, P18, P20, P22, and P24 lines of the CO2 laser for temperatures from 200 to 300 K and for pressures from 100 to 1100 mb. The temperature variation of the continuum absorption coefficient of water vapor is taken into account semi-empirically from Burch's data. The total absorption coefficient from the present calculations falls within + or - 20 percent of the results of McClatchey and Selby. The transmission loss which the CO2 pulsed laser Doppler system experiences was calculated for flight test conditions for the five P-lines. The total transmission loss is approximately 7 percent higher at the P16 line and 10 percent lower at the P24 line compared to the P20 line. Comparison of the CO2 laser with HF and DF laser transmission reveals the P2(8) line at 3.8 micrometers of the DF laser is much better from the transmission point of view for altitudes below 10 km.

Murty, S. S. R.↗

Residual infrared absorption in Ti:Al2O3 crystals

The performance of Ti:Al2O3 lasers is impaired generally by an infrared absorption that occurs in the laser output wavelength region. On the basis of data for as-grown and annealed samples cut from Ti:Al2O3 crystals grown by the vertical-gradient-freeze (VGF) technique, we previously proposed that the residual absorption is due to Ti(3+) to Ti(4+) pairs. In this report, we present additional data that confirm this ion-pair model for the residual absorption, which can be attributed to excitation of the 3d electron of the Ti(3+) ion perturbed by the Coulomb field of the neighboring Ti(4+) ion and/or an associated Al vacancy.

Source record↗