Search NASA⌕ Search

SEARCH · Search NASA

Results for “light-emitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Formation of a Fluorous/Organic Biphasic Supramolecular Octopus Assembly for Enhanced Porphyrin Phosphorescence in Air

The trinuclear triangle-shaped system [tris{3,5-bis(heptafluoropropyl)-1,2,4-triazolatosilver(I)}] (1) and the multi-armed square-shaped metalloporphyrin PtOEP or the free porphyrin base H2OEP serve as excellent octopus hosts (OEP=2,3,7,8,12,13,17,18-octaethyl-21H,23H-porphine). Coupling of the fluorous/organic molecular octopi 1 and H2OEP or PtOEP by strong quadrupole-quadrupole and metal- interactions affords the supramolecular assemblies [1PtOEP] or [1H(2)OEP] (2a), which feature nanoscopic cavities surrounding the upper triangular and lower square cores. The fluorous/organic biphasic configuration of [1PtOEP] leads to an increase in the phosphorescence of PtOEP under ambient conditions. Guest molecules can be included in the biphasic double-octopus assembly in three different site-selective modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LED lighting efficacy: Status and directions

A monumental shift from conventional lighting technologies (incandescent, fluorescent, high intensity discharge) to LED lighting is currently transpiring. The primary driver for this shift has been energy and associated cost savings. LED lighting is now more efficacious than any of the conventional lighting technologies with room to still improve. Near term, phosphor converted LED packages have the potential for efficacy improvement from 160 lm/W to 255 lm/W. Longer term, color-mixed LED packages have the potential for efficacy levels conceivably as high as 330 lm/W, though reaching these performance levels requires breakthroughs in green and amber LED efficiency. LED package efficacy sets the upper limit to luminaire efficacy, with the luminaire containing its own efficacy loss channels. In this paper, based on analyses performed through the U.S. Department of Energy Solid State Lighting Program, various LED and luminaire loss channels are elucidated, and critical areas for improvement identified. Beyond massive energy savings, LED technology enables a host of new applications and added value not possible or economical with previous lighting technologies. These include connected lighting, lighting tailored for human physiological responses, horticultural lighting, and ecologically conscious lighting. Finally, none of these new applications would be viable if not for the high efficacies that have been achieved, and are themselves just the beginning of what LED lighting can do.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of the Number and Substitution Pattern of Carbazole Donors on the Singlet and Triplet State Energies in a Series of Carbazole-Oxadiazole Derivatives Exhibiting Thermally Activated Delayed Fluorescence

Substitution of a varying number of 9H-carbazole donors onto 2-(pentafluorophenyl)-5-phenyl-1,3,4-oxadiazole yields a series of donor–acceptor compounds with similar electrochemical band gaps, but dissimilar optical properties. Each substitution of a carbazole onto the 2- and 4-positions results in a 150–200 meV stabilization of the first singlet excited state, evident in the fluorescent emission. Here, the first triplet excited state is less sensitive to these substitutions, leading to a reduced energy separation between the singlet and triplet states, ΔE ST , with increasing carbazole content. OLED devices made using the donor–acceptor compounds exhibiting the lowest ΔE ST were fabricated and exhibit sky blue emission with an external quantum efficiency of up to 24.4% at a luminance of 10 cd m –2 , and 9.2% at 1000 cd m –2 .

36 MATERIALS SCIENCE↗

Over What Length Scale Does an Inorganic Substrate Perturb the Structure of a Glassy Organic Semiconductor?

While the bulk structure of vapor-deposited glasses has been extensively studied, structure at buried interfaces has received little attention, despite being important for organic electronic applications. To learn about glass structure at buried interfaces, we study the structure of vapor-deposited glasses of the organic semiconductor DSA-Ph (1,4-di-[4-(N,N-diphenyl)amino]styrylbenzene) as a function of film thickness; the structure is probed with grazing incidence X-ray scattering. Here, we deposit on silicon and gold substrates and span a film thickness range of 10–600 nm. Our experiments demonstrate that interfacial molecular packing in vapor-deposited glasses of DSA-Ph is more disordered compared to the bulk. At a deposition temperature near room temperature, we estimate ~8 nm near the substrate can have modified molecular packing. Molecular dynamics simulations of a coarse-grained representation of DSA-Ph reveal a similar length scale. In both the simulations and the experiments, deposition temperature controls glass structure beyond this interfacial layer of a few nanometers.

36 MATERIALS SCIENCE↗

Symmetry and diffusivity of the interstitial hydrogen shallow-donor center in In 2 O 3

Uniaxial stress experiments performed for the 3306 cm -1 vibrational line assigned to the interstitial-hydrogen, shallow-donor center in In 2 O 3 reveal its symmetry and transition- moment direction. The defect alignment that can be produced by a [001] stress applied at 165 K is due to a process that is also a hydrogen- diffusion jump, providing a microscopic determination of the diffusion constant for H in In 2 O 3 and its mechanism. Lastly, our experimental results strongly complement theoretical predictions for the structure and diffusion of the interstitial hydrogen donor center in In 2 O 3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The crystal structure of bis{3,5-difluoro-2-[4-(2,4,6-trimethylphenyl)pyridin-2-yl]phenyl}(picolinato)iridium(III) and its 4- tert -butylpyridin-2-yl analogue

The crystal structures of bis{3,5-difluoro-2-[4-(2,4,6-trimethylphenyl)pyridin-2-yl]phenyl-κ 2 N , C 1 }(picolinato-κ 2 N , O )iridium(III), [Ir(C 20 H 16 F 2 N) 2 C 6 H 4 NO 2 )], 1 , and bis[2-(4- tert -butylpyridin-2-yl)-3,5-difluorophenyl-κ 2 N , C 1 ](picolinato-κ 2 N , O )iridium(III), [Ir(C 15 H 14 F 2 N) 2 (C 6 H 4 NO 2 )], 2 , are presented herein. These phosphorescent cyclometallated iridium(III) compounds have been structurally investigated in order to better understand the nature of their blue-shifted emssions while maintaining high quantum yields. Compound 1 exhibits substantial twisting of the mesitylene rings out of the plane of the attached pyridine ring, with dihedral angles of 67.0 (1) and 78.7 (1)° between the best mean planes. For both compounds, the contribution of disordered solvent molecule(s) was removed using the SQUEEZE [Spek (2015). Acta Cryst. C 71 , 9–18] routine in PLATON [Spek (2015). Acta Cryst. C 71 , 9–18]. These solvent molecules are not considered in the given chemical formula and other crystal data.

: crystal structure↗

Feature issue introduction: light, energy and the environment, 2017

The editors introduce the feature issue on 'Energy, Light and the Environment (LEE) 2017', which is based on the topics presented at a congress of the same name held in Boulder, CO, US, from November 6 to November 9. This feature issue presents 13 papers selected from the voluntary submissions by attendees who presented at the progress and have extended their work into complete research articles. Furthermore, the feature issue highlights contributions from authors who presented their research at this congress.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chapter 6: Residential Lighting Evaluation Protocol

In recent years, residential lighting has represented a significant share of ratepayer-funded energy-efficiency electricity savings. Utilities have achieved the majority of these savings by promoting the purchase and installation of compact fluorescent lamps (CFLs), both standard 'twister' bulbs and specialty CFLs such as reflectors, A-Lamps, globes, and dimmable lights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2019 Lighting R&D Opportunities

BTO’s Lighting R&D Opportunities is updated annually and covers foundational R&D needs for lighting technology and lighting application understanding that will result in maximum energy savings while also optimizing for building occupant well-being and productivity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Benchmarks of UV LEDs and Comparisons with White LEDs

The primary goal of this report is to benchmark the initial level of performance of a selection of commercial UV LEDs across all three bands (i.e., UV-A, UV-B, UV-C). To provide the initial performance benchmarks, a test matrix containing 13 different UV LED products was created in association with the LED Systems Reliability Consortium (LSRC). The products in this test matrix were all commercially available as of June 2021, and at least 22 samples of each product were tested. In addition, two common, commercial white LEDs were tested to provide a benchmark against blue-pumped white LEDs. Testing of the samples included electrical performance testing (e.g., current-voltage measurements) and photometric testing in a calibrated integrating sphere capable of measuring devices in the UV-A, UV-B, and UV-C bands. The electrical testing provided insights into the performance of the semiconductor layers in the LEDs, allowing parameters such as the threshold voltage (V th ) and serial resistance (R serial ) of each sample to be determined. The photometric testing provided insights into emission wavelengths, peak shapes, and radiant efficiencies for each sample. Combined, the information from these tests permits the overall device efficiencies to be compared and provides insights into the electrical and optical performance of the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 U.S. Lighting Market Characterization

The Lighting Market Characterization report details how many lighting products (lamps and luminaires) were installed in the U.S. as of 2020, where they were installed, and how much energy they consumed. It also highlights key changes in U.S. lighting market characteristics between 2015 and 2020. This is the fourth edition of the LMC report; previous versions were released in 2002, 2012 and 2017. By publishing summary estimates of installed stock and energy use of various general illumination lighting products, these reports help DOE and others plan effective lighting research and development programs based on changing needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 U.S. Lighting Market Characterization

The Lighting Market Characterization report details how many lighting products (lamps and luminaires) were installed in the U.S. as of 2020, where they were installed, and how much energy they consumed. It also highlights key changes in U.S. lighting market characteristics between 2015 and 2020. This is the fourth edition of the LMC report; previous versions were released in 2002, 2012 and 2017. By publishing summary estimates of installed stock and energy use of various general illumination lighting products, these reports help DOE and others plan effective lighting research and development programs based on changing needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 U.S. Lighting Market Characterization

The Lighting Market Characterization report details how many lighting products (lamps and luminaires) were installed in the U.S. as of 2020, where they were installed, and how much energy they consumed. It also highlights key changes in U.S. lighting market characteristics between 2015 and 2020. This is the fourth edition of the LMC report; previous versions were released in 2002, 2012 and 2017. By publishing summary estimates of installed stock and energy use of various general illumination lighting products, these reports help DOE and others plan effective lighting research and development programs based on changing needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗