Search NASA⌕ Search

SEARCH · Search NASA

Results for “multimode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗

Revealing the Bacterial Quorum-Sensing Effect on the Biofilm Formation of Diatom Cylindrotheca sp. Using Multimodal Imaging

Diatoms contribute to carbon fixation in the oceans by photosynthesis and always form biofouling organized by extracellular polymeric substances (EPS) in the marine environment. Bacteria-produced quorum-sensing signal molecules N-acyl homoserine lactones (AHLs) were found to play an important role in the development of Cylindrotheca sp. in previous studies, but the EPS composition change was unclear. This study used the technology of alcian blue staining and scanning electron microscopy (SEM), confocal laser scanning microscopy (CLSM), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly observe the biofilm formation process. The results showed that AHLs promote the growth rates of diatoms and the EPS secretion of biofilm components. AHLs facilitated the diatom-biofilm formation by a forming process dependent on the length of carbon chains. AHLs increased the biofilm thickness and the fluorescence intensity and then altered the three-dimensional (3D) structures of the diatom-biofilm. In addition, the enhanced EPS content in the diatom-biofilm testified that AHLs aided biofilm formation. This study provides a collection of new experimental evidence of the interaction between bacteria and microalgae in fouling biofilms.

59 BASIC BIOLOGICAL SCIENCES↗

Multimodal Imaging of Alzheimer Pathophysiology in the Brain's Default Mode Network

The spatial correlations between the brain's default mode network (DMN) and the brain regions known to develop pathophysiology in Alzheimer's disease (AD) have recently attracted much attention. In this paper, we compare results of different functional and structural imaging modalities, including MRI and PET, and highlight different patterns of anomalies observed within the DMN. Multitracer PET imaging in subjects with and without dementia has demonstrated that [C-11]PIB- and [F-18]FDDNP-binding patterns in patients with AD overlap within nodes of the brain's default network including the prefrontal, lateral parietal, lateral temporal, and posterior cingulate cortices, with the exception of the medial temporal cortex (especially, the hippocampus) where significant discrepancy between increased [F-18]FDDNP binding and negligible [C-11]PIB-binding was observed. [F-18]FDDNP binding in the medial temporal cortex—a key constituent of the DMN—coincides with both the presence of amyloid and tau pathology, and also with cortical areas with maximal atrophy as demonstrated by T1-weighted MR imaging of AD patients.

Shin, Jonghan↗

AI-multimodal/XAS-NNE

Neural network ensembles for X-ray absorption spectroscopy of molecules and materials. Companion code for preprint https://arxiv.org/abs/2210.00336.

Carbone, Matthew↗

A Multi-Sample Standoff Multimodal Biometric System

Abstract The data captured by existing standoff biometric systems typically has lower biometric recognition performance than their close range counterparts due to imaging challenges, pose challenges, and other factors. To assist in overcoming these limitations systems typically perform in a multi-modal capacity such as Honeywell s Combined Face and Iris (CFAIRS) [21] system. While this improves the systems performance, standoff systems have yet to be proven as accurate as their close range equivalents. We will present a standoff system capable of operating up to 7 meters in range. Unlike many systems such as the CFAIRS our system captures high quality 12 MP video allowing for a multi-sample as well as multi-modal comparison. We found that for standoff systems multi-sample improved performance more than multi-modal. For a small test group of 50 subjects we were able to achieve 100% rank one recognition performance with our system.

Barstow, Del R↗

Hadamard multimode optical imaging transceiver

Disclosed is a method and system for simultaneously acquiring and producing results for multiple image modes using a common sensor without optical filtering, scanning, or other moving parts. The system and method utilize the Walsh-Hadamard correlation detection process (e.g., functions/matrix) to provide an all-binary structure that permits seamless bridging between analog and digital domains. An embodiment may capture an incoming optical signal at an optical aperture, convert the optical signal to an electrical signal, pass the electrical signal through a Low-Noise Amplifier (LNA) to create an LNA signal, pass the LNA signal through one or more correlators where each correlator has a corresponding Walsh-Hadamard (WH) binary basis function, calculate a correlation output coefficient for each correlator as a function of the corresponding WH binary basis function in accordance with Walsh-Hadamard mathematical principles, digitize each of the correlation output coefficient by passing each correlation output coefficient through an Analog-to-Digital Converter (ADC), and performing image mode processing on the digitized correlation output coefficients as desired to produce one or more image modes. Some, but not all, potential image modes include: multi-channel access, temporal, range, three-dimensional, and synthetic aperture.

47 OTHER INSTRUMENTATION↗

LOSS ESTIMATE FOR ITER ECH TRANSMISSION LINE INCLUDING MULTIMODE PROPAGATION

The ITER electron cyclotron heating (ECH) transmission lines (TLs) are 63.5-mm-diam corrugated waveguides that will each carry 1 MW of power at 170 GHz. The TL is defined here as the corrugated wave guide system connecting the gyrotron mirror optics unit (MO U) to the entrance of the ECH launcher and includes miter bends and other corrugated wave guide components. The losses on the ITER TL have been calculated for four possible cases corresponding to having HE(11) mode purity at the input of the TL of 100, 97, 90, and 80%. The losses due to coupling, ohmic, and mode conversion loss are evaluated in detail using a numerical code and analytical approaches. Estimates of the calorimetric loss on the line show that the output power is reduced by about 5, +/- 1% because of ohmic loss in each of the four cases. Estimates of the mode conversion loss show that the fraction of output power in the HE(11) mode is similar to 3% smaller than the fraction of input power in the HE(11) mode. High output mode purity therefore can be achieved only with significantly higher input mode purity. Combining both ohmic and mode conversion loss, the efficiency of the TL from the gyrotron MOU to the ECH launcher can be roughly estimated in theory as 92% times the fraction of input power in the HE(11) mode.

Shapiro, Michael↗

Multimode imaging device

Apparatus for detecting and locating a source of gamma rays of energies ranging from 10-20 keV to several MeV's includes plural gamma ray detectors arranged in a generally closed extended array so as to provide Compton scattering imaging and coded aperture imaging simultaneously. First detectors are arranged in a spaced manner about a surface defining the closed extended array which may be in the form a circle, a sphere, a square, a pentagon or higher order polygon. Some of the gamma rays are absorbed by the first detectors closest to the gamma source in Compton scattering, while the photons that go unabsorbed by passing through gaps disposed between adjacent first detectors are incident upon second detectors disposed on the side farthest from the gamma ray source, where the first spaced detectors form a coded aperture array for two or three dimensional gamma ray source detection.

47 OTHER INSTRUMENTATION↗

Multimodality Plant Imaging of Small Molecules

Positron emission tomography (PET) is a non-invasive imaging technique used to diagnose disease and monitor therapy. PET imaging has had tremendous impact in healthcare delivery resulting in improved outcomes and reduced costs. The discovery and development of PET is one of the achievements of the Department of Energy’s (DOE) support of the peaceful uses of the atom. This project is a logical extension of the use of the PET technique to live plant imaging to advance DOE’s biological and environmental initiatives.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗