Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Magnetically-Switched, Long-Pulse XeCl Laser

Careful shaping of input pulses helps XeCl excimer laser produce lowdivergence, narrow-band light beam. Long-pulse laser achieves narrow-band output by multiple passes of beam through precisely adjusted Fabry-Perot etalons. Pulse-forming network and saturable-inductor switch enable fast pulse rise to peak voltage, followed by long residence at peak.

Pacala, T. J.↗

Study of the energy dependence of the underlying event in proton-antiproton collisions

We study charged particle production (p(T) > 0.5 GeV/c, vertical bar eta vertical bar < 0.8) in proton-antiproton collisions at total center-of-mass energies root s = 300 GeV, 900 GeV, and 1.96 TeV. We use the direction of the charged particle with the largest transverse momentum in each event to define three regions of eta - phi space: "toward", "away", and "transverse." The average number and the average scalar pT sum of charged particles in the transverse region are sensitive to the modeling of the "underlying event." The transverse region is divided into a MAX and MIN transverse region, which helps separate the "hard component" (initial and final-state radiation) from the "beam-beam remnant" and multiple parton interaction components of the scattering. The center-of-mass energy dependence of the various components of the event is studied in detail. The data presented here can be used to constrain and improve QCD Monte Carlo models, resulting in more precise predictions at the LHC energies of 13 and 14 TeV.

Aaltonen, T.↗

SU-E-T-296: Dosimetric Analysis of Small Animal Image-Guided Irradiator Using High Resolution Optical CT Imaging of 3D Dosimeters

Purpose: To verify the dosimetric characteristics of a small animal image-guided irradiator using a high-resolution of optical CT imaging of 3D dosimeters. Methods: PRESAEGE 3D dosimeters were used to determine dosimetric characteristics of a small animal image-guided irradiator and compared with EBT2 films. Cylindrical PRESAGE dosimeters with 7cm height and 6cm diameter were placed along the central axis of the beam. The films were positioned between 6×6cm{sup 2} cubed plastic water phantoms perpendicular to the beam direction with multiple depths. PRESAGE dosimeters and EBT2 films were then irradiated with the irradiator beams at 220kVp and 13mA. Each of irradiated PRESAGE dosimeters named PA1, PA2, PB1, and PB2, was independently scanned using a high-resolution single laser beam optical CT scanner. The transverse images were reconstructed with a 0.1mm high-resolution pixel. A commercial Epson Expression 10000XL flatbed scanner was used for readout of irradiated EBT2 films at a 0.4mm pixel resolution. PDD curves and beam profiles were measured for the irradiated PRESAGE dosimeters and EBT2 films. Results: The PDD agreements between the irradiated PRESAGE dosimeter PA1, PA2, PB1, PB2 and the EB2 films were 1.7, 2.3, 1.9, and 1.9% for the multiple depths at 1, 5, 10, 15, 20, 30, 40 and 50mm, respectively. The FWHM measurements for each PRESAEGE dosimeter and film agreed with 0.5, 1.1, 0.4, and 1.7%, respectively, at 30mm depth. Both PDD and FWHM measurements for the PRESAGE dosimeters and the films agreed overall within 2%. The 20%–80% penumbral widths of each PRESAGE dosimeter and the film at a given depth were respectively found to be 0.97, 0.91, 0.79, 0.88, and 0.37mm. Conclusion: Dosimetric characteristics of a small animal image-guided irradiator have been demonstrated with the measurements of PRESAGE dosimeter and EB2 film. With the high resolution and accuracy obtained from this 3D dosimetry system, precise targeting small animal irradiation can be achieved.

60 APPLIED LIFE SCIENCES↗

Note: Rigid holder to host and bend a crystal for multiple volume reflection of a particle beam

A holder to lodge and bend a silicon crystal to excite multivolume reflection of a high-energy particle beam has been designed and fabricated. A mechanically robust and stable structure fastens a crystal at best condition for experiments. The holder has allowed the observation of 12-time repeated volume reflection with very high efficiency. We detail the most important features behind the construction of the holder together with the characterization of the crystal being bent by the holder.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Accelerator Merges Several Beams

Intense ion beam formed by merging multiple ion beamlets into one concentrated beam. Beamlet holes in graphite screen and focusing grids arranged in hexagonal pattern. Merged beam passes through single hole in each of aluminum accelerator and decelerator grids. Ion extraction efficiency, beam intensity, and focusing improved.

Aston, G.↗

Expanded beam deflection method for simultaneous measurement of displacement and vibrations of multiple microcantilevers

Here we present an extension of optical beam deflection (OBD) method for measuring displacement and vibrations of an array of microcantilevers. Instead of focusing on the cantilever, the optical beam is either focused above or below the cantilever array, or focused only in the axis parallel to the cantilevers length, allowing a wide optical line to span multiple cantilevers in the array. Each cantilever reflects a part of the incident beam, which is then directed onto a photodiode array detector in a manner allowing distinguishing between individual beams. Each part of reflected beam behaves like a single beam of roughly the same divergence angle in the bending sensing axis as the incident beam. Since sensitivity of the OBD method depends on the divergence angle of deflected beam, high sensitivity is preserved in proposed expanded beam deflection (EBD) method. At the detector, each spot's position is measured at the same time, without time multiplexing of light sources. This provides real simultaneous readout of entire array, unavailable in most of competitive methods, and thus increases time resolution of the measurement. Expanded beam can also span another line of cantilevers allowing monitoring of specially designed two-dimensional arrays. In this paper, we present first results of application of EBD method to cantilever sensors. We show how thermal noise resolution can be easily achieved and combined with thermal noise based resonance frequency measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian inference of electron density and ion temperature profiles from neutral beam and halo Balmer- α emission at Wendelstein 7-X

By employing Bayesian inference techniques, the full electron density profile from the plasma core to the edge of Wendelstein 7-X (W7-X) is inferred solely from neutral hydrogen beam and halo Balmer- α (H α ) emission data. The halo is a cloud of neutrals forming in the vicinity of the injected neutral beam due to multiple charge exchange reactions. W7-X is equipped with several neutral hydrogen beam heating sources and an H α spectroscopy system that views these sources from different angles and penetration depths in the plasma. As the beam and halo emission form complex spectra for each spatial point that are non-linearly dependent on the plasma density profile and other parameters, a complete model from the neutral beam injection and halo formation through to the spectroscopic measurements is required. The model is used here to infer electron density profiles for a range of common W7-X plasma scenarios. The inferred profiles show good agreement with profiles determined by the Thomson scattering and interferometry diagnostics across a broad range of absolute densities without any changes to the input or fitting parameters. The time evolution of the density profile in a discharge with continuous core density peaking is successfully reconstructed, demonstrating sufficient spatial resolution to infer strongly shaped profiles. Furthermore, it is shown as a proof of concept that the model is also able to infer the main ion temperature profile using the same data set.

forward modeling↗

Nonperturbative Algorithm for the Resistive Wall Impedance of General Cross-Section Beam Pipes.

Nonperturbative algorithm for the resistive wall impedance of general cross-section beam pipes; ABSTRACT = We present an algorithm for calculating the impedance of infinitely long beam pipes with arbitrary cross section. The method is not restricted to ultrarelativistic beams or perturbative approximations with respect to the wall surface impedance or skin penetration depth. We exemplify our algorithm with a calculation of the impedance for rectangular metallic beam pipes. Unlike the situation in the perturbative regime, where the beam pipe geometry modifies the metallic resistive-wall impedances by only a multiplicative factor, the beam pipe geometry has a more complex influence on the impedance when nonultrarelativistic effects are significant and in the ultrarelativistic regime at both small and large frequencies. Since our algorithm requires the boundary conditions at the beam pipe wall to be provided as linear relations between the transverse components of the electromagnetic field, we discuss a general algorithm to calculate these boundary conditions for multilayer beam pipes with arbitrary cross section.

Macridin, Alexandru↗

SU-E-T-73: Commissioning of a Treatment Planning System for Proton Spot Scanning

Purpose: A treatment planning system (TPS) was commissioned for clinical use with a fixed beam line proton delivery system. An outline of the data collection, modeling, and verification is provided. Methods: Beam data modeling for proton spot scanning in CMS Xio TPS requires the following measurements: (i) integral depth dose curves (IDDCs); (ii) absolute dose calibration; and (iii) beam spot characteristics. The IDDCs for 18 proton energies were measured using an integrating detector in a single spot field in a water phantom. Absolute scaling of the IDDCs were performed based on ion chamber measurements in mono-energetic 10×10 cm{sup 2} fields in water. Beam spot shapes were measured in air using a flat panel scintillator detector at multiple planes. For beam model verification, more than 45 uniform dose phantom and patient plans were generated. These plans were used to measure range, point dose, and longitudinal and lateral profiles. Tolerances employed for verification are: point dose and longitudinal profiles, ±2%; range, ±1 mm; FWHM for lateral profiles, ±2 mm; and patient plan dose distribution, gamma index of >90% at 3%/3 mm criteria. Results: More than 97% of the point dose measurements out of 115 were within +/-2% with maximum deviation of 3%. 98% of the ranges measured were within 1 mm with maximum deviation of 1.4mm. The normalized depth doses were within 2% at all depths. The maximum error in FWHM of lateral profiles was found to be less than 2mm. For 5 patient plans representing different anatomic sites, a total of 38 planes for 12 beams were analyzed for gamma index with average value of 99% and minimum of 94%. Conclusions: The planning system is successfully commissioned and can be safely deployed for clinical use. Measurements of IDDCs on user beam are highly recommended instead of using standard beam IDDCs.

60 APPLIED LIFE SCIENCES↗

Beamline Insertions Manager at Jefferson Lab

The beam viewer system at Jefferson Lab provides operators and beam physicists with qualitative and quantitative information on the transverse electron beam properties. There are over 140 beam viewers installed on the 12 GeV CEBAF accelerator. This paper describes an upgrade consisting of replacing the EPICS-based system tasked with managing all viewers with a mixed system utilizing EPICS and high-level software. Most devices, particularly the beam viewers, cannot be safely inserted into the beam line during high-current beam operations. Software is partly responsible for protecting the machine from untimely insertions. The multiplicity of beam-blocking and beam-vulnerable devices motivates us to try a data-driven approach. The beamline insertions application components are centrally managed and configured through an object-oriented software framework created for this purpose. A rules-based engine tracks the configuration and status of every device, along with the beam status of the machine segment containing the device. The application uses this information to decide on which device actions are allowed at any given time.

43 PARTICLE ACCELERATORS↗

InN/InGaN multiple quantum wells emitting at 1.5 {mu}m grown by molecular beam epitaxy

This work reports on the growth by molecular beam epitaxy and characterization of InN/InGaN multiple quantum wells (MQWs) emitting at 1.5 {mu}m. X-ray diffraction (XRD) spectra show satellite peaks up to the second order. Estimated values of well (3 nm) and barrier (9 nm) thicknesses were derived from transmission electron microscopy and the fit between experimental data and simulated XRD spectra. Transmission electron microscopy and XRD simulations also confirmed that the InGaN barriers are relaxed with respect to the GaN template, while the InN MQWs grew under biaxial compression on the InGaN barriers. Low temperature (14 K) photoluminescence measurements reveal an emission from the InN MQWs at 1.5 {mu}m. Measurements as a function of temperature indicate the existence of localized states, probably due to InN quantum wells' thickness fluctuations as observed by transmission electron microscopy.

36 MATERIALS SCIENCE↗

Parametric study of high-energy ring-shaped electron beams from a laser wakefield accelerator

Abstract Laser wakefield accelerators commonly produce on-axis, low-divergence, high-energy electron beams. However, a high charge, annular shaped beam can be trapped outside the bubble and accelerated to high energies. Here we present a parametric study on the production of low-energy-spread, ultra-relativistic electron ring beams in a two-stage gas cell. Ring-shaped beams with energies higher than 750 MeV are observed simultaneously with on axis, continuously injected electrons. Often multiple ring shaped beams with different energies are produced and parametric studies to control the generation and properties of these structures were conducted. Particle tracking and particle-in-cell simulations are used to determine properties of these beams and investigate how they are formed and trapped outside the bubble by the wake produced by on-axis injected electrons. These unusual femtosecond duration, high-charge, high-energy, ring electron beams may find use in beam driven plasma wakefield accelerators and radiation sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emittance Measurements at FAST Facility

The FAST facility at Fermilab recently been commissioned has demonstrated the generation of electron beam within a wide range of parameter (energy, charge) suitable for accelerator-science and beam-physics experiments. This accelerator consists of a photo-electron gun, injector, ILC-type cryomodules, and multiple downstream beam-lines. It will mainly serve as injector for the upcoming Integrable Optical Test Accelerator (IOTA). At the same time we will also carry out a LINAC based intense gamma ray experiment based on the Inverse Compton scattering. It is essential to understand the beam emittance for both experiments. A number of techniques are used to characaterizing the beam emittance including slit based method and quad scan method. An on-line emittance measurement based on multi-slit method is developed so the emittance measured will be immediately available to support further beam optimization. In this report we will present the results from the emittance studies using this tool. We will also present the emittance measurement based on quads scan technique for the high energy beam line.

43 PARTICLE ACCELERATORS↗

Radial modes of laterally stiffened piezoelectric disc transducers for ultrasonic collimated beam generation

Here, we numerically investigate the resonance and vibration characteristics of radial modes of laterally stiffened piezoelectric disc transducers. Lateral stiffening is modeled using a spring and vibration characteristics of the piezo-disc are investigated with increasing lateral stiffness. It is found that the resonant frequency response of the radial modes follows an asymptotic behavior approaching that of a clamped disc with increasing lateral stiffness. The radial mode vibration pattern of the discs is also found to be affected by lateral stiffness. While the vibration pattern of a free disc corresponds to a Bessel function, laterally stiffened discs show edge-effects where they depart from the Bessel-like behavior. In addition, a fully clamped piezo-disc is found to have an extra side-lobe when compared to a free disc. Ultrasonic beam profiles generated from radial modes of laterally stiffened discs are numerically investigated. It is found that the free piezo-disc generates a Bessel beam that has multiple side-lobes. Increasing the lateral stiffness results in a significant reduction of side-lobes in the beam profile. This technique of generating a collimated beam with side-lobe reduction finds significant applications in imaging through concrete, drilling mud, and other highly attenuating materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

43 PARTICLE ACCELERATORS↗

Cold Atom Source Containing Multiple Magneto-Optical Traps

An apparatus that serves as a source of a cold beam of atoms contains multiple two-dimensional (2D) magneto-optical traps (MOTs). (Cold beams of atoms are used in atomic clocks and in diverse scientific experiments and applications.) The multiple-2D-MOT design of this cold atom source stands in contrast to single-2D-MOT designs of prior cold atom sources of the same type. The advantages afforded by the present design are that this apparatus is smaller than prior designs.

Ramirez-Serrano, Jaime↗