Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Evaluating Global Aerosol Models and Aerosol and Water Vapor Properties Near Clouds

Project goals: (1) Use the routine surface and airborne measurements at the ARM SGP site, and the routine surface measurements at the NSA site, to continue our evaluations of model aerosol simulations; (2) Determine the degree to which the Raman lidar measurements of water vapor and aerosol scattering and extinction can be used to remotely characterize the aerosol humidification factor; (3) Use the high temporal resolution CARL data to examine how aerosol properties vary near clouds; and (4) Use the high temporal resolution CARL and Atmospheric Emitted Radiance Interferometer (AERI) data to quantify entrainment in optically thin continental cumulus clouds.

54 ENVIRONMENTAL SCIENCES↗

Spherical lamellar grating interferometer for airborne astronomical observations of far infrared objects

A lamellar-grating interferometer designed for airborne IR astronomy is described, and its response to a laboratory far-IR source and to Jupiter as viewed from NASA's Kuiper Airborne Observatory is discussed. The theory of lamellar-grating interferometers is reviewed, advantages over Michelson interferometers are noted, and the optical arrangement for the lamellar-grating instrument is indicated. The response of the instrument is illustrated using purged and unpurged spectra of a 1000-K blackbody source as well as a raw spectrum of Jupiter containing many absorption features (probably telluric) identified with rotation bands of H2O. It is noted that the interferometer's self-collimation allows for efficient operation with a minimum of auxiliary optics.

Pipher, J. L.↗

Study of optical techniques for the Ames unitary wind tunnels. Part 3: Angle of attack

A review of optical sensors that are capable of accurate angle of attack measurements in wind tunnels was conducted. These include sensors being used or being developed at NASA Ames and Langley Research Centers, Boeing Airplane Company, McDonald Aircraft Company, Arnold Engineering Development Center, National Aerospace Laboratory of the Netherlands, National Research Council of Canada, and the Royal Aircraft Establishment of England. Some commercial sensors that may be applicable to accurate angle measurements were also reviewed. It was found that the optical sensor systems were based on interferometers, polarized light detector, linear or area photodiode cameras, position sensing photodetectors, and laser scanners. Several of the optical sensors can meet the requirements of the Ames Unitary Plan Wind Tunnel. Two of these, the Boeing interferometer and the Complere lateral effect photodiode sensors are being developed for the Ames Unitary Plan Wind Tunnel.

Lee, George↗

Polarization Considerations for the Laser Interferometer Space Antenna (LISA)

A polarization ray trace model of the Laser Interferometer Space Antenna's (LISA) optical path is being created. The model will be able to assess the effects of various polarizing elements and the optical coatings on the required picometer level interferometry. All of the computational steps are described in detail. This should eliminate any ambiguities associated with polarization ray trace modeling of interferometers and provide a basis for determining its limitations and serve as a clearly defined starting point for future improvements.

Waluschka, Eugene↗

Polarization Considerations for the Laser Interferometer Space Antenna

A polarization ray trace model of the Laser Interferometer Space Antenna s (LISA) optical path is being created. The model will be able to assess the effects of various polarizing elements and the optical coatings on the required, very long path length, picometer level dynamic interferometry. The computational steps are described. This should eliminate any ambiguities associated with polarization ray tracing of interferometers and provide a basis for determining the computer model s limitations and serve as a clearly defined starting point for future work.

Waluschka, Eugene↗

CGH Figure Testing of Aspherical Mirrors in Cold Vacuums

An established method of room-temperature interferometric null testing of mirrors having simple shapes (e.g., flat, spherical, or spheroidal) has been augmented to enable measurement of errors in the surface figures of off-axis, non-axisymmetric, aspherical mirrors when the mirrors are located inside cryogenic vacuum chambers. The established method involves the use of a computer-generated hologram (CGH), functionally equivalent to a traditional null lens, to modify the laser beam of an imaging interferometer to obtain a reference wavefront that matches the ideal surface figure of a mirror under test. The CGH is inserted at the appropriate position and orientation in the optical path of the imaging interferometer, which, in turn, is appropriately positioned and oriented with respect to the mirror under test. Deviations of the surface figure of the mirror from the ideal surface figure manifest themselves as interference fringes. Interferograms are recorded and analyzed to deduce figure errors.

Chambers, Victor John↗

Multiple spacecraft Michelson stellar interferometer

Results of an orbital analysis and performance assessment of SAMSI (Spacecraft Array for Michelson Spatial Interferometry) are presented. The device considered includes two one-meter telescopes in orbits which are identical except for slightly different inclinations; the telescopes achieve separations as large as 10 km and relay starlight to a central station which has a one-meter optical delay line in one interferometer arm. It is shown that a 1000-km altitude, zero mean inclination orbit affords natural scanning of the 10-km baseline with departures from optical pathlength equality which are well within the corrective capacity of the optical delay line. Electric propulsion is completely adequate to provide the required spacecraft motions, principally those needed for repointing. Resolution of 0.00001 arcsec and magnitude limits of 15 to 20 are achievable.

Stachnik, R. V.↗

Balloon borne optical disk mass storage system

An on-board data recording system for balloon-borne interferometer using a vacuum operable, ruggedized WORM optical drive is presented. This system, as presently under development, provides 320 Mbytes of data storage (or approximately 11 hrs at the 64 kbits/sec telemetry rate of the experiment). It has the capability of recording the unmodified telemetry bit system as transmitted or doing some preprocessing of the data onboard. The system is compact and requires less than 28 watts of battery power to operate.

Vanek, M. D.↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

Two-color method for optical astrometry - Theory and preliminary measurements with the Mark III stellar interferometer

The two-color method for interferometric astrometry provides a means of reducing the error in a stellar position measurement attributable to atmospheric turbulence. The primary limitation of the method is shown to be turbulent water vapor fluctuations. Secondary atmospheric effects caused by diffraction from small refractive-index inhomogeneities and differential refraction for the observation of stars away from zenith are shown to introduce errors that behave as white noise and which should not be significant. Other potential error sources due to photon noise, systematic instrumental effects, and imperfect data reduction are also considered. The improvement in accuracy possible with the two-color method is estimated as a factor of 5-10 over the corresponding one-color measurement. Some preliminary two-color measurements with the Mark III stellar interferometer at Mt. Wilson are presented, which demonstrate a factor of about 5 reduction in the amplitude of the atmospheric fluctuations in a stellar position measurement.

Colavita, M. Mark↗

Long-term stability of a Fabry-Perot interferometer used for measurement of stellar Doppler shift

The use of a fiber-optic-link CCD-detector Fabry-Perot interferometer (McMillan et al., 1985, 1986, and 1988) to obtain high-accuracy measurements of stellar Doppler shifts at KPNO is described in detail and illustrated with sample data. Particular attention is given to accuracy requirements and techniques for reducing errors, resolution (orders of 50 mA at wavelength 4300 A are separated by 640 mA), CCD sensitivity, observing and data-processing operations, and the control of environmental conditions. Standard-deviation data and statistics on seven solar-type stars are presented in tables, and the time evolution of the radial velocity of Beta Com is shown in a graph.

Mcmillan, R. S.↗

Diagnostics for ion beam driven high energy density physics experiments

Intense beams of heavy ions are capable of heating volumetric samples of matter to high energy density. Experiments are performed on the resulting warm dense matter (WDM) at the NDCX-I ion beam accelerator. The 0.3 MeV, 30 mA K{sup +} beam from NDCX-I heats foil targets by combined longitudinal and transverse neutralized drift compression of the ion beam. Both the compressed and uncompressed parts of the NDCX-I beam heat targets. The exotic state of matter (WDM) in these experiments requires specialized diagnostic techniques. We have developed a target chamber and fielded target diagnostics including a fast multichannel optical pyrometer, optical streak camera, laser Doppler-shift interferometer (Velocity Interferometer System for Any Reflector), beam transmission diagnostics, and high-speed gated cameras. We also present plans and opportunities for diagnostic development and a new target chamber for NDCX-II.

43 PARTICLE ACCELERATORS↗

GAIA and beyond: The perspective from the milliarcseconds of Hubble and Hipparcos

Astrometry with the Hubble space telescope and Hipparcos satellite advanced the optical astrometric accuracies to the milliarcsec level. The global astrometric interferometer for astrophysics (GAIA) satellite and other proposed optical interferometry space missions would advance the optical astrometric accuracy to better than 10 microarcsec. A catalog figure of merit is defined which allows a quantitative comparison to be carried out for astrometric catalogs. Using two specific astrophysical problems, the level of the expected scientific contribution from a GAIA-type mission is assessed. The two problems are: the age of the globular clusters in relation to the age of the Universe, and the initial mass function compared with fluctuations in the star formation rate with time.

Hemenway, Paul D.↗

Interferometers Sharpen Measurements for Better Telescopes

Over the last decade, there have been a number of innovations that have made possible the largest and most powerful telescope of its time: the James Webb Space Telescope (JWST). Scheduled to launch in 2018, JWST will provide insight into what the oldest, most distant galaxies look like. When engineers build a first-of-its-kind instrument like the JWST, they often must make new tools to construct the new technology. Throughout the decades of planning, development, and construction of the JWST, NASA has worked with numerous partners to spur innovations that have enabled the telescope s creation. Though the JWST s launch date is still several years away, a number of these innovations are spinning off to provide benefits here on Earth. One of these spinoffs has emerged from the extensive testing the JWST must undergo to ensure it will function in the extreme environment of space. In order to test the JWST instruments in conditions that closely resemble those in space, NASA uses a cryogenic vacuum chamber. By dropping the temperatures down to -400 F and employing powerful pumps to remove air from the chamber, engineers can test whether the JWST instruments will function once the spacecraft leaves Earth. Traditionally, a phase-shifting interferometer is used to measure optics like the JWST s mirrors to verify their precise shape, down to tens of nanometers, during manufacturing. However, the large size of the mirrors, coupled with vibration induced by the cryo-pumps, prohibits the use of traditional phase-shifting interferometers to measure the mirrors within the chamber environment. Because the JWST will be located in deep space, far from any possible manned service mission, it was essential to find a robust solution to guarantee the performance of the mirrors.

Source record↗

Detection of Terahertz Pulses Using a Modified Sagnac Interferometer

We describe a time resolved, interferometric method to detect terahertz (THz) pulses based on Sagnac geometry. A ZnTe electro-optic crystal is placed in one arm of the interferometer, and the THz-induced optical phase shift is demodulated by allowing the two arms to optically interfere. The theorital principle behind this new method is illustrated and a detailed comparison with the traditional electro-optic (EO) sampling technique used in THz time domain spectroscopy is performed. Key features of this new method are highlighted, serving as an aid to identify where this method may be useful in future applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamical quantum phase transitions in interacting atomic interferometers

Particle-wave duality has allowed physicists to establish atomic interferometers as celebrated complements to their optical counterparts in a broad range of quantum devices. In particular, interactions give rise to multiparticle correlations unavailable in linear interferometers. Here, we show that interactions lead to dynamical quantum phase transitions (DQPTs) between NOON states in an atomic interferometer. These transition points result from zeros of the Loschmidt echo, which approach the real axis of the complex time plane in the large-particle-number limit, and signify pair condensates, another type of exotic quantum states featured with prevailing two-body correlations. Such DQPTs thus provide us with a new angle to understand many-body states emergent from quantum nonequilibrium dynamics. Further, our work also suggests interacting atomic interferometers as a new tool for creating highly entangled states to beat the standard quantum limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ calibration of a light source in a sensor device

A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

58 GEOSCIENCES↗

System and Method for Scan Range Gating

A system for scanning light to define a range gated signal includes a pulsed coherent light source that directs light into the atmosphere, a light gathering instrument that receives the light modified by atmospheric backscatter and transfers the light onto an image plane, a scanner that scans collimated light from the image plane to form a range gated signal from the light modified by atmospheric backscatter, a control circuit that coordinates timing of a scan rate of the scanner and a pulse rate of the pulsed coherent light source so that the range gated signal is formed according to a desired range gate, an optical device onto which an image of the range gated signal is scanned, and an interferometer to which the image of the range gated signal is directed by the optical device. The interferometer is configured to modify the image according to a desired analysis.

Zuk, David M.↗