Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Effect of Reactor Radiation on the Thermal Conductivity of Graphite-based Dispersion Fuel

The Fukushima Daiichi nuclear accident in 2011 stimulated materials development efforts to improve the current fuel design for Light Water Reactors (LWRs). From fuel element to fuel cladding, new concepts in advanced nuclear fuel development have been proposed, studied, and tested. The new fuel systems are expected to have better resistance to damage, melting, and chemical reaction during accident scenarios. To test the performance and accident tolerance of the advanced fuel, it is highly preferable to simulate off-normal transients in addition to standard in-core fuel performance tests (available at High Flux Isotope Reactor at Oak Ridge National Laboratory and Advanced Test Reactor at Idaho National Laboratory). The Transient Reactor Test Facility (TREAT) is now being prepared to restart its operation, performing transient testing to assist advanced fuel development. TREAT was operated from 1959 to 1994, and was extensively used to generate thousands of reactor transients for different programs. The reactor has not operated since 1994. The original fuel used at TREAT was graphite-based dispersion fuel with highly-enriched uranium (HEU, 93.1% enriched uranium). For nonproliferation purposes, a fuel conversion program, supported by U.S. Department of Energy, National Nuclear Safety Administration (NNSA), Office of Material Management and Minimization (NA-23) Reactor Conversion Program, is underway to develop a replacement core in which the UO{sub 2} contains only low-enriched uranium (LEU). The preliminary LEU core design has shown a much lower carbon/uranium atomic ratio and enrichment than in the HEU core design. To achieve performance similar to the HEU core, the prospective LEU core will contain a much higher density of UO{sub 2} particles. As a result, a higher level of radiation damage, particularly from fission fragments emerging from the UO{sub 2} particles, can be expected dependent on the UO{sub 2} particle size within the fuel. To support LEU fuel design, the present study investigates the effect of reactor radiations on the thermal conductivity of graphite-based dispersion fuel. Both neutron- and fission-radiation induced degradations of the fuel are modeled, and validated based on the available experimental data. In this study, the reactor-radiation induced thermal conductivity degradation of graphite-based dispersion fuel was analyzed. A semi-empirical method to model the relative thermal conductivity with reactor radiations was proposed and validated. The proposed method can be further applied to predict the changes in the thermal conductivity of the prospective LEU TREAT fuel during long-term operation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Underwater Laser Cutting Technology - 16491

Underwater dismantling is advantageous for the highly radioactive apparatuses such as nuclear reactor internals. The most advantageous point of underwater dismantling is a radiation exposure reduction for workers. Underwater dismantling can take advantage of the water shielding. Then it can make the exposure reduction for workers and contamination reduction for work area be realized. And, underwater laser cutting technology has major three advantages. First advantage is lower action force. Therefore it can be possible that we can use a simple remote device for underwater dismantling operation. Second advantage is to reduce secondary waste. The cutting kerf size of underwater laser cutting is very narrow, so the amount of cutting dross is very small. Third advantage is very simple methods for dismantling. This advantage can reduce process time for cutting. On the other hand, the contaminated off-gas which generates during cutting should be taken care. IHl Corporation (IHI) developed the underwater laser cutting devices. The characteristic of IHI's laser cutting torch is that there is no air habitat. Therefore, the positions of the torch and the access to the narrow space have little limitation. Using the device the series of performance tests were performed in order to verify the ability of it. In the first Laboratory test at 0.2 meter depth of water, we evaluated the optimum cutting parameters. The next underwater demonstration test at 6 meters depth of water was performed. In the test the cutting performance, which the mild steel plate of the thickness of 12 mm can be cut at the speed of 300 mm/min with the horizontal and downward position of torch was verified. Then the hot bubble test using real radioactive test coupons was performed to evaluate the radioactivity carried as air borne and the decontamination factor (DF) of off-gas passing through water. This document provides an overview of the underwater laser cutting device that has been developed by IHI, and the advantage of these devices for the dismantling work of underwater apparatus. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modified Thermoresponsive Hyperbranched Polymers for Improved Viscosity and Enhanced Lubricity of Engine Oils

The manuscript captures the chronological succession of the molecular design progression through multiple architectures and topologies of the polymeric viscosity index improvers and their rheology bench test performance. Tribology testing was also performed on selected analogs and their friction and wear was evaluated. Finally, a top performing polymer was selected for engine testing, scaled-up, and its rheological performance in a complete formulation was assessed. The engine performance of the viscosity index improver was examined against an industry-established baseline.

02 PETROLEUM↗

Fluid infusion system

Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

Source record↗

Procedure for Performing Security Camera Optical Performance Analysis Tests

Digital security camera technologies proliferate the security marketplace with manufacturers extoling the functions, features, specifications and virtues of their cameras. A process to comparatively analyze security camera technologies using international camera analysis standards and methods provides a defensible means to assess camera image quality on a technically comparable basis. The procedures in this document use ISO standard camera test charts and camera image analysis software to perform test chart image analysis for comparative camera assessment. Step-by-step procedures for acquiring test chart images in the laboratory and producing analysis data using analysis software GUI controls and interfaces for comparative analysis of security camera image quality are detailed in this document. The procedures have been validated through the test and analysis of fixed box and 180 degree field of view multi-imager cameras as well as, fixed and varifocal lenses and analog-to-digital video encoder image quality performance attributes.

42 ENGINEERING↗

Preliminary characterization of active MEMS valves.

Partial characterization of a series of electrostatically actuated active microfluidic valves is to be performed. Tests are performed on a series of 24 valves from two different MEMS sets. Focus is on the physical deformation of the structures under variable pressure loadings, as well as voltage levels. Other issues that inhibit proper performance of the valves are observed, addressed and documented as well. Many microfluidic applications have need for the distribution of gases at finely specified pressures and times. To this end a series of electrostatically actuated active valves have been fabricated. Eight separate silicon die are discussed, each with a series of four active valves present. The devices are designed such that the valve boss is held at a ground, with a voltage applied to lower contacts. Resulting electrostatic forces pull the boss down against a series of stops, intended to create a seal as well as prevent accidental shorting of the device. They have been uniquely packaged atop a stack of material layers, which have inlaid channels for application of fluid flow to the backside of the valve. Electrical contact is supplied from the underlying printed circuit board, attached to external supplies and along traces on the silicon. Pressure is supplied from a reservoir of house compressed air, up to 100 Psig. This is routed through a Norgren R07-200-RGKA pressure regulator, rated to 150 Psig. From there flow passes a manually operated ball valve, and to a flow meter. Two flow meters were utilized; initially an Omega FMA1802 rated at 10 sccm, and followed by a Flocat model for higher flow rates up to 100 sccm. An Omega DPG4000-500 pressure gauge produced pressure measurements. Optical measurements were returned via a WYKO Interferometry probe station. This would allow for determination of physical deformations of the device under a variety of voltage and pressure loads. This knowledge could lead to insight as to the failure mechanisms of the device, yielding improvements for subsequent fabrications.

47 OTHER INSTRUMENTATION↗

Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J). Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

Utility-Scale Power Tower Solar Systems: Performance Acceptance Test Guidelines

The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.

14 SOLAR ENERGY↗

Novel Application of Carbonate Fuel Cell for Capturing Carbon Dioxide from Flue Gas Streams

To address concerns about climate change resulting from emission of CO2 by coal-fueled power plants, FuelCell Energy, Inc. has developed the Combined Electric Power and Carbon-dioxide Separation (CEPACS) system concept. The CEPACS system utilizes Electrochemical Membrane (ECM) technology derived from the Company’s Direct FuelCell® products. The system separates the CO2 from the flue gas of other plants and produces electric power using a supplementary fuel. FCE is currently evaluating the use of ECM to cost effectively separate CO2 from the flue gas of Pulverized Coal (PC) power plants under a U.S. Department of Energy contract. The overarching objective of the project is to verify that the ECM can achieve at least 90% CO2 capture from the flue gas with no more than 35% increase in the cost of electricity. The project activities include: 1) laboratory scale operational and performance tests of a membrane assembly, 2) performance tests of the membrane to evaluate the effects of impurities present in the coal plant flue gas, in collaboration with Pacific Northwest National Laboratory, 3) techno-economic analysis for an ECM-based CO2 capture system applied to a 550 MW existing PC plant, in partnership with URS Corporation, and 4) bench scale (11.7 m2 area) testing of an ECM-based CO2 separation and purification system.

CO2 separation, Carbon capture, electrochemical me↗

Test Data Analysis of a Spray Bar Zero-Gravity Liquid Hydrogen Vent System for Upper Stages

To support development of a zero-gravity pressure control capability for liquid hydrogen (LH2), a series of thermodynamic venting system (TVS) tests was conducted in 1996 and 1998 using the Marshall Space Flight Center (MSFC) multipurpose hydrogen test bed (MHTB). These tests were performed with ambient heat leaks =20 and 50 W for tank fill levels of 90%, 50%, and 25%. TVS performance testing revealed that the spray bar was highly effective in providing tank pressure control within a 7-kPa band (131-138 Wa), and complete destratification of the liquid and the ullage was achieved with all test conditions. Seven of the MHTB tests were correlated with the TVS performance analytical model. The tests were selected to encompass the range of tank fill levels, ambient heat leaks, operational modes, and ullage pressurants. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature obtained from the TVS model were compared with the test data. During extended self-pressurization periods, following tank lockup, the model predicted faster pressure rise rates than were measured. However, once the system entered the cyclic mixing/venting operational mode, the modeled and measured data were quite similar.

Hedayat, A.↗

Infrared suppressor effect on T63 turboshaft engine performance

Tests were conducted to determine if there are performance penalties associated with the installation of infrared (IR) suppressors on the T63-A-700 turboshaft engine. The testing was done in a sea-level, static test cell. The same engine (A-E402808 B) was run with the standard OH-58 aircraft exhaust stacks and with the ejector-type IR suppressors in order to make a valid comparison. Repeatability of the test results for the two configurations was verified by rerunning the conditions over a period of days. Test results showed no measurable difference in performance between the standard exhaust stacks and the IR suppressors.

Bailey, E. E.↗

NEXIS Reservoir Cathode 2000 Hour Life Test

The current design of the Nuclear Electric Xenon Ion System (NEXIS) employs a reservoir cathode as both the discharge and neutralizer cathode to meet the 10 yr thruster design life. The main difference between a reservoir cathode and a conventional discharge cathode is the source material (barium-containing compound) is contained within a reservoir instead of in an impregnated insert in the hollow tube. However, reservoir cathodes do not have much life test history associated with them. In order to demonstrate the feasibility of using a reservoir cathode as an integral part of the NEXIS ion thruster, a 2000 hr life test was performed. Several proof-of-concept (POC) reservoir cathodes were built early in the NEXIS program to conduct performance testing as well as life tests. One of the POC cathodes was sent to Marshall Space Flight Center (MSFC) where it was tested for 2000 hrs in a vacuum chamber. The cathode was operated at the NEXIS design point of 25 A discharge current and a xenon flow rate of 5.5 sccm during the 2000 hr test. The cathode performance parameters, including discharge current, discharge voltage, keeper current; keeper voltage, and flow rate were monitored throughout test. Also, the temperature upstream of cathode heater, the temperature downstream of the cathode heater, and the temperature of the orifice plate were monitored throughout the life of the test. The results of the 2000 hr test will be described in this paper. Included in the results will be time history of discharge current, discharge voltage, and flow rate. Also, a time history of the cathode temperature will be provided.

Vaughn, Jason↗

SWI 1.10 Testing Process

This procedure establishes a system for performing testing in the Six-Degree-Of-Freedom Dynamic Test System (SDTS). Testing includes development and verification testing of customer supplied Test Articles (TAs) and other testing requirements, as requested. This procedure applies to all SDTS testing operations and equipment. The procedure provides an overview of testing performed in the SDTS including test identification requirements, test planning and procedure development, test and performance inspection, test data analysis, and test report generation.

Stokes, LeBarian↗

Direct-field acoustic testing of a flight system : logistics, challenges, and results.

Before a spacecraft can be considered for launch, it must first survive environmental testing that simulates the launch environment. Typically, these simulations include vibration testing performed using an electro-dynamic shaker. For some spacecraft however, acoustic excitation may provide a more severe loading environment than base shaker excitation. Because this was the case for a Sandia Flight System, it was necessary to perform an acoustic test prior to launch in order to verify survival due to an acoustic environment. Typically, acoustic tests are performed in acoustic chambers, but because of scheduling, transportation, and cleanliness concerns, this was not possible. Instead, the test was performed as a direct field acoustic test (DFAT). This type of test consists of surrounding a test article with a wall of speakers and controlling the acoustic input using control microphones placed around the test item, with a closed-loop control system. Obtaining the desired acoustic input environment - proto-flight random noise input with an overall sound pressure level (OASPL) of 146.7 dB-with this technique presented a challenge due to several factors. An acoustic profile with this high OASPL had not knowingly been obtained using the DFAT technique prior to this test. In addition, the test was performed in a high-bay, where floor space and existing equipment constrained the speaker circle diameter. And finally, the Flight System had to be tested without contamination of the unit, which required a contamination bag enclosure of the test unit. This paper describes in detail the logistics, challenges, and results encountered while performing a high-OASPL, direct-field acoustic test on a contamination-sensitive Flight System in a high-bay environment.

33 ADVANCED PROPULSION SYSTEMS↗

The GlueX central drift chamber: Design and performance

Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Glenn SmallSat/CubeSat Activities and Capabilities

This presentation provides an overview of recent activities at NASA Glenn Research Center (GRC) in the development and performance test characterization of electric propulsion subsystems intended for small satellite (SmallSat) and cubesat missions. The status and recent progress of several on-going development activities related to smallsat/cubesat missions at GRC will be discussed. These projects and activities include Sub-Kilowatt Electric Propulsion (SKEP), iodine compatibility testing of Hall thruster components, performance testing of a cold gas propulsion system for BioSentinel, and performance testing of the Massachusetts Institute of Technology electrospray propulsion units. The functions and capabilities of GRC's Electric Propulsion Systems Branch will be covered. These capabilities are available to provide propulsion subsystem manufacturers independent, third-party assessments of their technologies for use on future NASA missions. A plan to generate standards for the development of smallsat/cubesat propulsion systems for Class D missions has been initiated and will be outlined in this presentation.

Pencil, Eric↗

DETERMINATION OF THE CREEP–FATIGUE INTERACTION DIAGRAM FOR ALLOY 617

Alloy 617 is the leading candidate material for an intermediate heat exchanger for the very high temperature reactor. To evaluate the behavior of this material in the expected service conditions, creep-fatigue testing was performed. Testing has been performed primarily on a single heat of material at 850 and 950°C for total strain ranges of 0.3 to 1% and tensile hold times as long as 240 minutes. At 850°C, increases in the tensile hold duration degraded the creep fatigue resistance, at least to the investigated strain-controlled hold time of up to 60 minutes at the 0.3% strain range and 240 minutes at the 1.0% strain range. At 950°C, the creep-fatigue cycles to failure becomes constant with increasing hold times, indicating saturation occurs at relatively short hold times. The creep and fatigue damage fractions have been calculated and plotted on a creep-fatigue interaction D-diagram. Results from earlier creep-fatigue tests at 800 and 1000°C on an additional heat of Alloy 617 are also plotted on the D-diagram. The methodology for calculating the damage fractions will be presented, and the effects of strain rate, strain range, temperature, hold time, and strain profile (i.e. holds in tension, compression or both) on the creep-fatigue damage will be explored.

36 MATERIALS SCIENCE↗

Performance evaluations of a liquid solar collector

Report presents procedures and results of thermal performance tests on single-covered liquid solar collector under simulated comditions. Test conditions and data are given in tables and graphs for stagnation tests and thermal performance test. In addition, time-constant test and incident-angle modifier test were conducted to determine transient effect and incident-angle effect. Results of collector load tests are also given.

Shih, K.↗