Search NASA⌕ Search

SEARCH · Search NASA

Results for “position”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Topographical Controls on Hillslope-Scale Hydrology Drive Shrub Distributions on the Seward Peninsula, Alaska

Observations indicate shrubs are expanding across the Arctic tundra, mainly on hillslopes and primarily in response to climate warming. However, the impact topography exerts on hydrology, nutrient dynamics, and plant growth can make untangling the mechanisms behind shrub expansion difficult. We examined the role topography plays in determining shrub expansion by applying a coupled transect version of a mechanistic ecosystem model (ecosys) in a tundra hillslope site in the Seward Peninsula, Alaska. Modeled biomass of the dominant plant functional types agreed well with field measurements (R 2 = 0.89) and accurately represented shrub expansion over the past 30 years inferred from satellite observations. In the well-drained crest position, canopy water potential and plant nitrogen (N) uptake was modeled to be low from plant and microbial water stress. Intermediate soil water content in the mid-slope position enhanced mineralization and plant N uptake, increasing shrub biomass. The deciduous shrub growth in the mid-slope position was further enhanced by symbiotic N 2 fixation primed by increased root carbon allocation. The gentle slope in the poorly drained lower-slope position resulted in saturated soil conditions that reduced soil O 2 concentrations, leading to lower root O 2 uptake and lower nutrient uptake and plant biomass. Additionally, a simulation that removed topographical interconnectivity between grid cells resulted in (1) a 28% underestimate of mean shrub biomass and (2) over or underestimated shrub productivity at the various hillslope positions. Our results indicate that land models need to account for hillslope-scale coupled surface and subsurface hydrology to accurately predict current plant distributions and future trajectories in Arctic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Tunable, Bacterio-Instructive Scaffolds Made from Functional Graphenic Materials

The balance of bacterial populations in the human body is critical for human health. Researchers have aimed to control bacterial populations using antibiotic substrates. However, antibiotic materials that non-selectively kill bacteria can compromise health by eliminating beneficial bacteria, which leaves the body vulnerable to colonization by harmful pathogens. Due to their chemical tunablity and unique surface properties, graphene oxide (GO)-based materials – termed “functional graphenic materials” (FGMs) – have been previously designed to be antibacterial but have the capacity to actively adhere and instruct probiotics to maintain human health. Numerous studies have demonstrated that negatively and positively charged surfaces influence bacterial adhesion through electrostatic interactions with the negatively charged bacterial surface. We found that tuning the surface charge of FGMs provides an avenue to control bacterial attachment without compromising vitality. Using E. coli as a model organism for gram-negative bacteria, we demonstrate that negatively charged Claisen graphene (CG), a reduced and carboxylated FGM, is bacterio-repellent through electrostatic repulsion with the bacterial surface. Though positively charged poly-L-lysine (PLL) is antibacterial when free in solution by inserting into the bacterial cell wall, here, we found that covalent conjugation of PLL to CG (giving PLLn-G) masks the antimicrobial activity of PLL by restricting polypeptide mobility. This allows the immobilized positive charge of the PLLn-Gs to be leveraged for E. coli adhesion through electrostatic attraction. We identified the magnitude of positive charge of the PLLn-G conjugates, which is modulated by the length of the PLL peptide, as an important parameter to tune the balance between the opposing forces of bacterial adhesion and proliferation. We also tested adhesion of gram-positive B. subtilis to these FGMs and found that the effect of FGM charge is less pronounced. B. subtilis adheres nondiscriminatory to all FGMs, regardless of charge, but adhesion is scarce and localized. Overall, this work demonstrates that FGMs can be tuned to selectively control bacterial response, paving the way for future development of FGM-based biomaterials as bacterio-instructive scaffolds through careful design of FGM surface chemistry.

Eckhart, Karoline E.↗

Search for active and inactive ion insertion sites in organic crystalline materials

The position of mobile active and inactive ions, specifically ion insertion sites, within organic crystals, significantly affects the properties of organic materials used for energy storage and ionic transport. Identifying the positions of these atomic (and ionic) sites in an organic crystal is challenging, especially when the element has low X-ray scattering power, such as lithium (Li) and hydrogen, which are difficult to detect by powder X-ray diffraction. First-principles calculations, exemplified by density functional theory (DFT), are very practical for confirming the relative stability of ion positions in materials. However, the lack of effective strategies to identify ion sites in these organic crystalline frameworks renders this task extremely challenging. This work presents two algorithms: the (i) efficient location of ion insertion sites from extrema in electrostatic local potential and charge density (ELIISE), and the (ii) ElectRostatic InsertioN (ERIN), which leverage charge density and electrostatic potential fields accessed from first-principles calculations, combined with the Simultaneous Ion Insertion and Evaluation (SIIE) workflow. SIIE inserts all ions simultaneously—to determine ion positions in organic crystals. We demonstrate that these methods accurately reproduce known ion positions in 16 organic materials and identify previously overlooked low-energy sites in tetralithium 2,6-naphthalenedicarboxylate (Li4NDC), an organic electrode material, highlighting the importance of inserting all ions simultaneously, as in the SIIE workflow. These algorithms are also integrated with off-the-shelf machine learning potentials, yielding promising results comparable to first-principles findings.

Gopidi, Harshan Reddy [Argonne National Laboratory↗

Effect of Accurate Modeling of Converter Interfaced Generation (CIG) on a Practical Bulk Power System

With increased penetration of converter interfaced generation (CIG) in power systems, it becomes imperative to adequately model them in both steady-state and dynamic simulations. There are several modeling approaches and simulation platforms for CIG. In addition, it is noted that suitability of modeling approaches and models is also dependent on the system conditions. However, their suitability has yet to be systematically analyzed, and this becomes a challenge in the industry without a systemic method. To tackle these challenges, in this paper, we first develop a methodology for identifying the maximum penetration of aggregated rooftop sources that can be represented as negative loads in both the steady state and dynamic analysis. Then we verify the suitability of positive-sequence performance-based model and detailed electromagnetic transient (EMT) model for utility-scale PV plants under different fault conditions. Based on the results, we perform dynamic simulations on a large practical system with both positive-sequence transient stability(TS) and EMT-TS hybrid simulation. Our study shows that positive-sequence performance based PV plant model is more suitable for study cases with faults relatively far away from the point of connection, and that positive-sequence models and TS simulation approach can produce comparable results with reference to EMT-TS hybrid simulation for normally-cleared single-line-to-ground faults, but the inadequacy of positive-sequence based model and simulation approach becomes obvious for prolonged-tripping of unbalanced faults in proximity of the PV plants.

Huang, Qiuhua↗

Effect of triangularity on ion-temperature-gradient-driven turbulence

The linear and nonlinear properties of ion-temperature-gradient-driven turbulence with adiabatic electrons are modeled for axisymmetric configurations for a broad range of triangularities δ, both negative and positive. Peak linear growth rates decrease with negative δ but increase and shift toward a finite radial wavenumber kx with positive δ. The growth-rate spectrum broadens as a function of kx with negative δ and significantly narrows with positive δ. Here, the effect of triangularity on linear instability properties can be explained through its impact on magnetic polarization and curvature. Nonlinear heat flux is weakly dependent on triangularity for |δ|≤0.5, decreasing significantly with extreme δ, regardless of sign. Zonal modes play an important role in nonlinear saturation in the configurations studied, and artificially suppressing zonal modes increased nonlinear heat flux by a factor of about four for negative δ, increasing with positive δ by almost a factor of 20. Proxies for zonal-flow damping and drive suggest that zonal flows are enhanced with increasing positive δ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Contribution of Lobe Power to Experiment Heating in the Advanced Test Reactor

In order to ease the computational burden associated with designing irradiation experiments in the Advanced Test Reactor (ATR), scaling factors are often used to estimate design parameters at different lobe powers. Here, this paper examines the validity of long-standing assumptions about the contribution of lobe power to total experiment heating in the ATR. For each of the ATR’s 77 different experiment positions, the fractional contribution of each of the ATR’s five lobes to the total heating in that position is calculated and compared to traditional assumptions. The updated fractional contributions are then used to scale heating rates in a sample problem, and the results are compared to traditional scaling methods as well as explicit MC21 heating calculations. It is concluded that for experiment locations in close proximity to the ATR driver fuel (i.e. flux traps and the A, H, and B positions), heating rates scaled with the updated fractional contributions generally agree better with explicit MC21 calculations than do heating rates scaled using the traditionally assumed contributions. For the I positions, which are located on the very periphery of the ATR core, both scaling methods led to poor results when compared against explicit calculations due to the effect that movement of the outer shim control cylinders has on the experiment heating in those positions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved electron energy distribution functions at the substrate during a HiPIMS discharge with cathode voltage reversal

Abstract The time-dependent plasma properties of a high-power impulse magnetron sputtering plasma are investigated which include a positive ‘kick’ pulse on the sputtering target 2 μ s after the main negative pulse, this reversing the voltage on the cathode. At a substrate 15 cm distant from the magnetron, the time-dependent electron energy distribution function (EEDF), plasma potential, potential commute time and plasma diffusion properties are measured using a single Langmuir probe. Results show that the positive pulse on the target expels plasma and raises the plasma potential across the chamber on the order of 1 to 2 μ s, which is the time scale of the electron diffusion. The EEDF at the substrate fits a Druyvesteyn distribution during the main negative pulse rising slightly in average energy over time. The distribution is still Druyvesteyn and at the very start of the positive pulse, but then loses the higher energy electrons and drops in average electron energy as the positive pulse progresses. A Boltzmann equation solver, BOLSIG+, was used to predict the EEDF at the substrate during the positive pulse and it agrees best with the measurements assuming a value of 0.2 Td for the E / N (electric field/gas number density).

Physics↗

Zonal flow screening in negative triangularity tokamaks

Here, this paper presents a comparative study of zonal flow screening in positive and negative triangularity tokamaks. Neoclassical screening sets the strength of zonal flow shear for fixed drive and damping. Orbit calculations show that the radial excursions of trapped particles are reduced in negative triangularity tokamaks, as compared to positive triangularity. Yet surprisingly, the neoclassical dielectric susceptibility actually increases with decreasing triangularity, such that the susceptibility is higher for negative triangularity than for positive triangularity. This is because the reduction in neoclassical polarization by shrinking the banana width is offset by the increase in neoclassical polarization by the enhancement of trapped fraction for negative triangularity. As a result, the zonal flow screening length is actually enhanced for negative triangularity, as compared to positive triangularity. Hence, the zonal flow residual is smaller for negative triangularity than for positive triangularity. Results from gyrokinetic simulations support the analytic calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive sampling for accelerating neutron diffraction-based strain mapping *

Abstract Neutron diffraction is a useful technique for mapping residual strains in dense metal objects. The technique works by placing an object in the path of a neutron beam, measuring the diffracted signals and inferring the local lattice strain values from the measurement. In order to map the strains across the entire object, the object is stepped one position at a time in the path of the neutron beam, typically in raster order, and at each position a strain value is estimated. Typical dwell times at neutron diffraction instruments result in an overall measurement that can take several hours to map an object that is several tens of centimeters in each dimension at a resolution of a few millimeters, during which the end users do not have an estimate of the global strain features and are at risk of incomplete information in case of instruments outages. In this paper, we propose an object adaptive sampling strategy to measure the significant points first. We start with a small initial uniform set of measurement points across the object to be mapped, compute the strain in those positions and use a machine learning technique to predict the next position to measure in the object. Specifically, we use a Bayesian optimization based on a Gaussian process regression method to infer the underlying strain field from a sparse set of measurements and predict the next most informative positions to measure based on estimates of the mean and variance in the strain fields estimated from the previously measured points. We demonstrate our real-time measure-infer-predict workflow on additively manufactured steel parts—demonstrating that we can get an accurate strain estimate even with 30%–40% of the typical number of measurements—leading the path to faster strain mapping with useful real-time feedback. We emphasize that the proposed method is general and can be used for fast mapping of other material properties such as phase fractions from time-consuming point-wise neutron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology↗

On negative induced polarization in frequency domain measurements

SUMMARY Induced polarization (IP) has been widely used to non-invasively characterize electrical conduction and polarization in the subsurface resulting from an applied electric field. Earth materials exhibit a lossy capacitance defined by a negative intrinsic phase in frequency-domain IP (FDIP) or a positive intrinsic chargeability in time-domain IP (TDIP). However, error-free positive apparent phase or negative apparent chargeability (i.e. negative IP effects) can occur in IP measurements over heterogeneous media. While negative IP effects in TDIP data sets have been discussed, no studies have addressed this topic in detail for FDIP measurements. We describe theory and numerical modelling to explain the origin of negative IP effects in FDIP measurements. A positive apparent phase may occur when a relatively high polarizability feature falls into negative sensitivity zones of complex resistivity measurements. The polarity of the apparent phase is determined by the distribution of subsurface intrinsic phase and resistivity, with the resistivity impacting the apparent phase polarity via its control on the sensitivity distribution. A physical explanation for the occurrence of positive apparent phase data is provided by an electric circuit model representing a four-electrode measurement. We also show that the apparent phase polarity will be frequency dependent when resistivity changes significantly with frequency (i.e. in the presence of significant IP effects). Consequently, negative IP effects manifest themselves in the shape of apparent phase spectra recorded with multifrequency (spectral IP) data sets. Our results imply that positive apparent phase measurements should be anticipated and should be retained during inversion and interpretation of single frequency and spectral IP data sets.

Geochemistry & Geophysics↗

Implementation of rapid diagnostics assays for detection of histoplasmosis and cryptococcosis in central american people living with HIV

Abstract Objectives Histoplasmosis and cryptococcosis are important public health problems in people living with HIV (PLHIV) in Central America. Conventional laboratory assays, based on microscopy and culture, are not optimal for the diagnosis of either disease. However, antigen (Ag) assays are rapid and highly accurate for the diagnosis of these infections. Methods Laboratory surveillance of PLHIV was carried out in four hospitals in Panama, Honduras and Nicaragua, between 2015 and 2019. Detection of Histoplasma antigens in urine was performed by enzyme immunoassay (EIA), and Cryptococcus antigen detection in sera and cerebrospinal fluid specimens was performed by lateral flow assay (LFA). Results A total of 4,453 PLHIV with clinical suspicion of histoplasmosis ( n = 1,343) or cryptococcosis ( n = 3,110; 2,721 sera and 389 CSF) were tested. Of 1,343 patients suspected of having histoplasmosis, 269 (20%) were Histoplasma Ag positive. Of 3,110 patients tested using the Cryptococcus Ag assay, 329 (11%) were positive. Honduras reported the highest positivity rates (32% for Histoplasma Ag, and 16% for Cryptococcus Ag); Panama reported the largest number of patients testing positive using the Histoplasma Ag assay ( n = 201); and Nicaragua reported the largest number of patients testing positive using the Cryptococcus Ag assay ( n = 170). Conclusion Here, we show how the implementation of rapid diagnostics assays impacted case detection and was useful for the care of people with advanced HIV. Rapid and accurate diagnosis could reduce mortality associated with histoplasmosis and cryptococcosis in PLHIV.

Caceres, Diego H.↗

Examining Cloud Feedback Components in the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM)

Cloud feedback remains the main source of uncertainty in climate sensitivity estimated by global climate models (GCMs), largely because subgrid cloud responses are parameterized in GCMs due to their coarse resolution. Here, this study examines cloud feedback in the global 3.25-km Simple Cloud-Resolving Energy Exascale Earth System Model (E3SM) Atmosphere Model (SCREAM 3 km) through a pair of 1-yr atmosphere-only simulations with control and +4-K sea surface temperature perturbations. SCREAM 3 km produces a positive cloud feedback that falls within but at the upper end of the range of Coupled Model Intercomparison Project phase 5 (CMIP5) and CMIP phase 6 (CMIP6) models and expert judgment. The positive cloud feedback arises from positive contributions from both high- and low-level clouds, with increases in high-cloud altitude and decreases in low-cloud amount and optical depth playing key roles. The stronger-than-CMIP-average feedback is mainly attributable to the high-cloud altitude feedback, owing to cloud tops rising nearly isothermally in SCREAM 3 km. The positive low-cloud amount feedback is weaker in SCREAM than in GCMs because estimated inversion strength (EIS) increases more dramatically with warming. A coarser 12-km resolution version of SCREAM exhibits a weaker positive cloud feedback than SCREAM 3 km, mainly because its low-cloud-radiative flux is more sensitive to EIS, leading to a stronger negative low-cloud amount feedback. With this process-level assessment of cloud feedback, this study reveals where SCREAM aligns with and diverges from conventional GCMs and expert assessment, providing insights to inform further model improvement and future expert assessment.

Cloud radiative effects↗

Mongooses ( Urva auropunctata ) as reservoir hosts of Leptospira species in the United States Virgin Islands, 2019–2020

During 2019–2020, the Virgin Islands Department of Health investigated potential animal reservoirs of Leptospira spp., the bacteria that cause leptospirosis. In this cross-sectional study, we investigated Leptospira spp. exposure and carriage in the small Indian mongoose (Urva auropunctata, syn: Herpestes auropunctatus), an invasive animal species. This study was conducted across the three main islands of the U.S. Virgin Islands (USVI), which are St. Croix, St. Thomas, and St. John. We used the microscopic agglutination test (MAT), fluorescent antibody test (FAT), real-time polymerase chain reaction (lipl32 rt-PCR), and bacterial culture to evaluate serum and kidney specimens and compared the sensitivity, specificity, positive predictive value, and negative predictive value of these laboratory methods. Mongooses (n = 274) were live-trapped at 31 field sites in ten regions across USVI and humanely euthanized for Leptospira spp. testing. Bacterial isolates were sequenced and evaluated for species and phylogenetic analysis using the ppkgene. Anti-Leptospira spp. antibodies were detected in 34% (87/256) of mongooses. Reactions were observed with the following serogroups: Sejroe, Icterohaemorrhagiae, Pyrogenes, Mini, Cynopteri, Australis, Hebdomadis, Autumnalis, Mankarso, Pomona, and Ballum. Of the kidney specimens examined, 5.8% (16/270) were FAT-positive, 10% (27/274) were culture-positive, and 12.4% (34/274) were positive by rt-PCR. Of the Leptospira spp. isolated from mongooses, 25 were L. borgpetersenii, one was L. interrogans, and one was L. kirschneri. Positive predictive values of FAT and rt-PCR testing for predicting successful isolation of Leptospira by culture were 88% and 65%, respectively. The isolation and identification of Leptospira spp. in mongooses highlights the potential role of mongooses as a wildlife reservoir of leptospirosis; mongooses could be a source of Leptospira spp. infections for other wildlife, domestic animals, and humans.

59 BASIC BIOLOGICAL SCIENCES↗

Soil Water Percolation Flux, April 2017 to March 2019, BR-Ma2, Manaus

Soil water percolation flux measurements derived from six passive wick flux meters across three topographic positions (valley, slope and plateau). Data has been processed to compute the mean for each topographic position where two flux meters were installed at each topographic position. Missing data represented a few percent of the total data set and were filled using two approaches. In the event one of the flux meters malfunctioned, we used data from the other sensor from the same topographic position without averaging. When both sensors were not working, such as during the period from September to October 2017 for the slope and valley and July 2018 for the plateau, data was filled using a nonlinear regression model that was based on local precipitation data and coefficients that were empirically derived for each topographic position. The metadata tab included in the .csv has additional information on locations where the sensors were installed, and other installation/maintenance details. Contact ksolander@lanl.gov if you need to use this dataset for additional information.

54 ENVIRONMENTAL SCIENCES↗

Analysis of the Trusted Inertial Terrain-Aided Navigation Measurement Function

The trusted inertial terrain-aided navigation (TITAN) algorithm leverages an airborne vertical synthetic aperture radar to measure the range to the closest ground points along several prescribed iso-Doppler contours. These TITAN minimum-range, prescribed-Doppler measurements are the result of a constrained nonlinear optimization problem whose optimization function and constraints both depend on the radar position and velocity. Owing to the complexity of this measurement definition, analysis of the TITAN algorithm is lacking in prior work. This publication offers such an analysis, making the following three contributions: (1) an analytical solution to the TITAN constrained optimization measurement problem, (2) a derivation of the TITAN measurement function Jacobian, and (3) a derivation of the Cramér-Rao lower bound on the estimated position and velocity error covariance. These three contributions are verified via Monte Carlo simulations over synthetic terrain, which further reveal two remarkable properties of the TITAN algorithm: (1) the along-track positioning errors tend to be smaller than the cross-track positioning errors, and (2) the cross-track positioning errors are independent of the terrain roughness.

TITAN↗

Climatology Perspective of Sensitive Regimes and Active Regions of Aerosol Indirect Effect for Cirrus Clouds over the Global Oceans

Long-term satellite climate data records (CDRs) of clouds and aerosols are used to investigate the aerosol indirect effect (AIE) of cirrus clouds over the global oceans from a climatology perspective. Our study focuses on identifying the sensitive regimes and active regions where AIE signatures easily manifest themselves in the sense of the long-term average of cloud and aerosol variables. The aerosol index (AIX) regimes of AIX < 0.18 and 0.18 < AIX < 0.46 are respectively identified as the sensitive regimes for negative and positive aerosol albedos and lifetime effects of cirrus clouds. Relative humidity first decreases (along with upward motions) and then reverses to increase (along with downward motions) in the first regime of negative aerosol albedo and lifetime effects. Relatively wet and strong upward motions are the favorable meteorological conditions for the second regime of positive aerosol albedo and lifetime effects. Two swath regions extending from 15°N to 30°N over the east coastal oceans of China and the USA are the active regions of positive aerosol albedo effects. Positive aerosol lifetime effects are only active or easy to manifest in the regions where a positive aerosol albedo effect is active. The results based on the long-term averaged satellite observations are valuable for the evaluation and improvement of aerosol-cloud interactions for cirrus clouds in global climate models.

54 ENVIRONMENTAL SCIENCES↗

Liquid Core Detection and Strand Condition Monitoring in a Continuous Caster Using Optical Fiber

Real-time monitoring of the liquid core position during the continuous casting of steel has been demonstrated using low-cost distributed optical-fiber-based strain sensors. These sensors were installed on the containment roll support structures in the segments of a production continuous caster to detect the position of the solid–liquid interface and monitor the strand condition during the continuous casting. Distributed Fiber Bragg Grating sensors (FBGs) were used in this work to monitor strain at six roll positions in the caster. The sensor performance was first validated by comparing optical strain measurements with conventional strain gauge measurements in the lab. Next, optical strain measurements were performed on an isolated caster segment in a segment maintenance facility using hydraulic jacks to simulate the presence of a liquid core under the roll. Finally, the sensors were evaluated during caster operation. The sensors successfully detected the load increase associated with the presence of a liquid core under each instrumented roll location. Incidents of bulging and roll eccentricity were also detected using frequency analysis of the optical strain signal. The liquid core position measurements were compared using predictions from computer models (digital twins) in use at the production site. The measurements were in good agreement with the model predictions, with a few exceptions. Under certain transient caster operating conditions, such as spraying practice changes and SEN exchanges, the model predictions deviated slightly from the liquid core position determined from strain measurements.

47 OTHER INSTRUMENTATION↗