Search NASA⌕ Search

SEARCH · Search NASA

Results for “predictive control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Economic Optimal Control for Minimizing Fuel Consumption of Heavy-Duty Trucks in a Highway Environment

This paper provides a comparative assessment of three economic optimal control strategies, aimed at minimizing the fuel consumption of heavy-duty trucks in a highway environment, under a representative lead vehicle model informed by traffic data. These strategies fuse a global, offline dynamic programming (DP) optimization with online model predictive control (MPC). We then show how two of the three strategies can be adapted to accommodate the presence of traffic and optimally navigate signalized intersections using infrastructure-to-vehicular (I2V) communication. The MPC optimization, which is local in nature, makes refinements to a coarsely (but globally, subject to grid resolution) optimized target velocity profile from the DP optimization. The three candidate economic MPC formulations that are evaluated include: a nonlinear time-based formulation that directly penalizes predicted fuel consumption, a nonlinear time-based formulation that penalizes braking effort as a surrogate for fuel consumption, and a linear distance-based convex formulation that maintains a tradeoff between energy expenditure and tracking of the coarsely optimized velocity profile obtained from DP. Using a medium-fidelity Simulink model, based on a Volvo truck's longitudinal and engine dynamics, we analyze the optimization's performance on four highway routes under various traffic scenarios. Results demonstrate 3.7-8.3% fuel economy improvement on highway routes without traffic and 6.5-10% on the same routes with traffic included. Furthermore, we present a detailed analysis of energy usage by "type" (aerodynamic losses, braking losses, and comparison of brake-specific fuel consumption), under each candidate control strategy.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization of Backscatter and Symmetry for Laser Fusion Experiments Using Multiple Tunable Wavelengths

A new additional wavelength-tuning capability has been implemented on the National Ignition Facility (NIF) laser allowing for unprecedented control of crossed-beam energy transfer (CBET) between all groups of beams for better performance of indirect-drive inertial confinement fusion (ICF) ignition experiments. In particular, this advance allows for negation and reversal of flow-induced CBET and the rebalancing of the intensity of different groups of beams within an indirect-drive (ICF) hohlraum. The experiments conducted at the NIF using a 1.1 MJ laser pulse with peak power of 390 TW demonstrate this high level of control through measurements of the precise changes to stimulated Brillouin scattering, typically driven by flow-induced CBET at the end of the pulse. Additionally, this new capability is shown to be able to predictably control gold-wall plasma expansion in the target driven by early-time flow-induced CBET. Estimates of early-time CBET from the wall expansion are shown to be consistent with simulation expectations. This new additional capability to control symmetry and backscatter expands the design space of current experiments and provides extra margin for increased laser energy in near-future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Time-Varying Output Delay Compensation-A Model-Free Approach and its Application on Cooperative On-Ramp Merging

This paper presents a model-free approach to compensate for time-varying output delay in networked control systems. The proposed architecture combines a model-free observer and the Smith predictor. The model-free observer estimates the current state while handling modeling errors and uncertainties of the system. The Smith predictor moves the effect of time delay outside the control closed-loop using the estimated delayed output and the actual output of the plant. The proposed method is applied to a cooperative on-ramp merging problem. First, an ultra-local model predictive control is implemented to provide a computationally efficient online speed planner agnostic to the vehicle dynamics. After that, a model-free observer is designed to estimate the current state. Finally, the proposed architecture is tested against a time-varying output delay with an upper bound of 200 milliseconds. The results demonstrate the effectiveness of the proposed method with improved tracking of intervehicle distance.

Waleed khan, Muhammad [The University of Texas at ↗

EASY-SHIFT v Alpha

The software is a generic, price- and load-responsive control algorithm integrating heat pumps with thermal energy storage. The algorithm leverages simple models of the system and easily accessible data to schedule operation of heat pumps and thermal energy storage in ways that minimize the cost of operating the heating/cooling system. This tool is specifically designed to be easy to interact with, and something that industry partners are able to adopt. There are two current state of the art approaches. Industry tends to develop very simple algorithms, with predetermined schedules that are not capable of changing operation in response to changes in operating environment. For example, a control designed to avoid high-price electricity from 5-8 PM will not be able to adapt if the high-price period changes to 4-9 PM. Academia commonly develops algorithms called Model predictive control (MPC). MPC requires extensive data and highly trained staff to develop a specific type of simulation model of the building, connect the building to optimization algorithms, and leverage powerful computers. Industry, with limited time/finance budgets for any project, is resistant to adopting MPC due to the associated high complexity and cost.

Grant, Peter [Lawrence Berkeley National Laborator↗

Automated Vehicles in Hazardous Merging Traffic: A Chance-Constrained Approach

To realize the energy efficiency and productivity benefits of automated driving, control algorithms must function safely among conventional vehicles. Prototype tests on public roads have revealed a trend of human-driven vehicles rear-ending automated ones. A popular belief holds that unusually conservative control algorithms play a role in such collisions. In August 2018, an automated vehicle was rear-ended while waiting to merge. Inspired by that incident, this paper examines a resemblant scenario in simulation using model predictive control for the automated vehicle. Constraint setup alternatives to avoid collisions with inattentive following vehicles are proposed and assessed in this simulation environment. In one variant, imminent rear-end collisions are detected and constraints are modified to promote more aggressive merging during such an event. Results show that higher-performing chance constraint designs can reduce collision probability, but may have other adverse effects depending on the particular algorithm.

Dollar, R. Austin↗

Alfalfa [SWR 18-17]

Alfalfa is a web based software service that implements a virtual building control system using the EnergyPlus simulation as a backend. Conventional building energy simulation is non interactive, meaning that a simulation is started and run to completion without any user input during the simulation. Alfalfa allows a client to start a building simulation, then interactively read sensor locations and dynamically command actuators in realtime. The Alfalfa web service conforms to the Project Haystack standard, which is a specification adopted by many building control system vendors. The service enables Haystack compliant control system vendors to test their control modules and algorithms without the need for a physical building or modifying their hardware and software, enabling faster and cheaper development cycles. Alfalfa has use cases beyond control system testing. One example is building fault detection, where physical building performance can be compared to simulated values in realtime, indicating where there may be a problem in the building. Another use case is informing predictive control systems, where near future events are simulated to premptively guide control decisions in the real building. This software is web based and designed to be self service. Users of Alfalfa can upload an OpenStudio building model and begin communicating with the simulated building without any advanced setup or configuration, as if they were communicating a real building control system. Behind the scenes, Alfalfa makes extensive use of Amazon Web Services, in order to scale from a very small number of users and buildings, to extremely large numbers in a cost effective way.

Benne, Kyle↗

Optimal Voltage Control in Low-Observable Unbalanced Distribution Systems

The increased integration of distributed energy resources (DERs) in distribution systems brings both advantages and technical challenges. High levels of DERs can often cause over/under voltage problems. Classical voltage control algorithms are based on full knowledge of voltage states across all nodes in the system. However, this may not be a practical assumption since many locations in distribution systems are unobservable. Therefore, this paper proposes a new model predictive control (MPC) based control algorithm that accounts for system unobservability to efficiently eliminate voltage violations with as low as 50% fraction of observable nodes. Additionally, an analytical voltage sensitivity framework is employed to quickly determine the change in voltage states due to PV injections. The effectiveness of the proposed method is validated via simulations on the unbalanced IEEE 37 node test system.

Abujubbeh, Mohammad↗

Real-Time On-Ramp Merging Control of Connected and Automated Vehicles using Pseudospectral Convex Optimization

Highway on-ramp merging can be a challenging task for human drivers due to the complex vehicle negotiations and interactions in limited time and space. Connected and automated vehicles (CAVs) have great potential to address the problem and offer many benefits in terms of safety, traffic efficiency, and fuel economy. However, real-time optimal control of CAVs still faces many challenges, including nonlinear dynamics, complex inter-vehicle interactions, and a highly dynamic and uncertain traffic environment. To address these challenges, we develop a novel control approach that balances the solution optimality and computational efficiency to determine optimal merging speed profiles in real time. Specifically, by employing a pseudospectral method and a sequential convex programming approach, two algorithms are proposed and implemented within the model predictive control (MPC) framework to enable real-time generation of optimal solutions for potential on-vehicle applications. The convergence and optimality of the proposed algorithms are validated by comparing with a general-purpose solver under different traffic scenarios.

Shi, Yang↗

Neural Network Model Of The PXIE RFQ Cooling System and Resonant Frequency Response

As part of the PIP-II Injector Experiment (PXIE) accel-erator, a four-vane radio frequency quadrupole (RFQ) accelerates a 30-keV, 1-mA to 10-mA H' ion beam to 2.1 MeV. It is designed to operate at a frequency of 162.5 MHz with arbitrary duty factor, including continuous wave (CW) mode. The resonant frequency is controlled solely by a water-cooling system. We present an initial neural network model of the RFQ frequency response to changes in the cooling system and RF power conditions during pulsed operation. A neural network model will be used in a model predictive control scheme to regulate the resonant frequency of the RFQ.

43 PARTICLE ACCELERATORS↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual blockade of IL-10 and PD-1 leads to control of SIV viral rebound following analytical treatment interruption

Human immunodeficiency virus (HIV) persistence during antiretroviral therapy (ART) is associated with heightened plasma interleukin-10 (IL-10) levels and PD-1 expression. We hypothesized that IL-10 and PD-1 blockade would lead to control of viral rebound following analytical treatment interruption (ATI). Twenty-eight ART-treated, simian immunodeficiency virus (SIV)mac 239 -infected rhesus macaques (RMs) were treated with anti-IL-10, anti-IL-10 plus anti-PD-1 (combo) or vehicle. ART was interrupted 12 weeks after introduction of immunotherapy. Durable control of viral rebound was observed in nine out of ten combo-treated RMs for >24 weeks post-ATI. Induction of inflammatory cytokines, proliferation of effector CD8 + T cells in lymph nodes and reduced expression of BCL-2 in CD4 + T cells pre-ATI predicted control of viral rebound. Twenty-four weeks post-ATI, lower viral load was associated with higher frequencies of memory T cells expressing TCF-1 and of SIV-specific CD4 + and CD8 + T cells in blood and lymph nodes of combo-treated RMs. These results map a path to achieve long-lasting control of HIV and/or SIV following discontinuation of ART.

60 APPLIED LIFE SCIENCES↗

Enhancing SRF cavity stability and minimizing detuning with data-driven resonance control based on dynamic mode decomposition

Effective resonance control of superconducting radio frequency (SRF) cavities is critical for large machines like LCLS-II, as failure to achieve proper control can result in increased RF power consumption, higher cryogenic heat loads, and increased costs. To address this challenge, we have developed a machine learning (ML) model based on the dynamic mode decomposition method to represent the forced cavity dynamics. Using this model, we designed a model predictive controller (MPC) and demonstrated through simulation that the MPC can effectively stabilize the amplitude and phase of SRF cavities using only a frequency actuator, even in the presence of multiple mechanical modes. The lightweight and explicit ML model makes the controller suitable for direct implementation on field-programmable gate arrays, unlocking the full potential of SRF linacs like LCLS-II, enabling higher beam power and energy, and also serving as an advanced motion controller for various applications, such as photon beamlines and storage rings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Sensing and Controls for Coal Gasification - Development of Model-Based Controls for GE's Gasifier and Syngas Cooler (Final Technical Report)

This report summarizes the achievements and final results of this program. The objective of this program is to develop a comprehensive systems approach to integrated design of sensing and control systems for an Integrated Gasification Combined Cycle (IGCC) plant, using advanced model-based techniques. In particular, this program is focused on the model-based sensing and control system design for the core gasification section of an IGCC plant. The overall approach consists of (i) developing a first-principles physics-based dynamic model of the gasification section, (ii) performing model-reduction where needed to derive low-order models suitable for controls analysis and design, (iii) developing a sensing system solution combining online sensors with model-based estimation for important process variables not measured directly, and (iv) optimizing the steady-state and transient operation of the plant for normal operation as well as for startup using model predictive controls (MPC). Initially, available process unit models were implemented in a common platform using Matlab/Simulink{reg_sign}, and appropriate model reduction and model updates were performed to obtain the overall gasification section dynamic model. Also, a set of sensor packages were developed through extensive lab testing and implemented in the Tampa Electric Company IGCC plant at Polk power station in 2009, to measure temperature and strain in the radiant syngas cooler (RSC). Plant operation data was also used to validate the overall gasification section model. The overall dynamic model was then used to develop a sensing solution including a set of online sensors coupled with model-based estimation using nonlinear extended Kalman filter (EKF). Its performance in terms of estimating key unmeasured variables like gasifier temperature, carbon conversion, etc., was studied through extensive simulations in the presence sensing errors (noise and bias) and modeling errors (e.g. unknown gasifier kinetics, RSC fouling). In parallel, an MPC solution was initially developed using ideal sensing to optimize the plant operation during startup pre-heating as well as steady state and transient operation under normal high-pressure conditions, e.g. part-load, base-load, load transition and fuel changes. The MPC simulation studies showed significant improvements both for startup pre-heating and for normal operation. Finally, the EKF and MPC solutions were coupled to achieve the integrated sensing and control solution and its performance was studied through extensive steady state and transient simulations in the presence of sensor and modeling errors. The results of each task in the program and overall conclusions are summarized in this final report.

01 COAL, LIGNITE, AND PEAT↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Building Automation

In this chapter, we focus on both need-based and vision-based control innovation for building automation for HVAC systems. After providing a brief background that describes different HVAC architectures and products, we describe the control challenges and opportunities from a needs-based point of view, at the equipment level, the systems level, and the building level. At the equipment level, increased use of continuously variable actuation such as variable speed compressors and fans, requires application of robust multivariable control that must consider various types of nonlinear behavior across increasingly larger operating envelopes. The objective at this level is to achieve robust and energy efficient operation. At the system level, coupled and interactive dynamics among subsystems are increasingly important to consider, and functional integration of these subsystems, along with set points and operating schedules are designed to minimize energy consumption and improve occupant comfort. At the building level, issues such as integration among other building systems, such as the building envelope and the electric grid, offer opportunities to develop new types of demand response and grid-interactive behaviors and technologies. At the higher levels, system dynamics and robust stability are less of an issue, similar to process control applications, while optimization and integration are more important, although dynamic stability is increasing an issue at the higher levels too. From a vision-driven innovation point of view, we describe three areas that will require sustained research efforts and will eventually impact building automation: Digital Twins, Model Predictive Control, and Grid Interactive Buildings.

Bortoff, Scott↗