Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Video Diagnostic for W7-X Stellarator

The video diagnostics for W7-X--which is under development--is devoted to observe plasma and frrst wall elements during operation, to warn in case of hot spots and dangerous heat load and to give information about the plasma size, position, edge structure, the geometry and location of magnetic islands and distribution of impurities. The video diagnostics will be mounted on the tangential AEQ-ports of the torus that are not straight and have about 2m length and a typical diameter of 0.1m which makes its realization more difficult. The geometry of the 10 tangential views of the AEQ-ports allows giving an almost complete overview of the vessel interior making this diagnostic indispensable for the machine operation. Different concepts of the diagnostics were investigated and finally the following design was selected. As a large heat load is expected on the optical window located at the plasma-facing end of the AEQ-port, the port window is protected by a cooled pinhole. An uncooled shutter located behind the pinhole can be closed to prevent window contamination during vessel conditioning discharges (glow discharge cleaning) and from inter-pulse deposition of soft a-C:H layers. The imaging optics and the detection sensor are located behind the port window in the port tube, which will be under atmospheric pressure. To detect the visible radiation distribution a new camera system called Event Detection Intelligent Camera (EDICAM) is under development. The system is divided into three major separated components. The Sensor Module contains only the selected CMOS sensor, the analog digital converters and the minimal electronics necessary for the communication with the subsequent camera system module called Image Processing and Control Unit (IPCU). Its simple structure makes the Sensor Module suitable to operate despite being exposed to ionizing (neutron, {gamma}-) radiation. The IPCU, which can be located far from the Sensor Module and therefore far from the plasma, is designed to perform real time evaluation of the images detecting predefined events, managing the sensor read-out and the input triggers and producing the output triggers generated by the detected events. The IPCU can also be used to reduce the amount of the stored data. A Standard 10 Gigabit Ethernet fiber optics connection connects the IPCU module to the PC with GigEVision communication protocol.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stochastic Waveform Estimation at the Fundamental Quantum Limit

Although measuring the deterministic waveform of a weak classical force is a well-studied problem, estimating a random waveform, such as the spectral density of a stochastic signal field, is much less well understood despite it being a widespread task at the frontier of experimental physics. State-of-the-art precision sensors of random forces must account for the underlying quantum nature of the measurement but the optimal quantum protocol for interrogating such linear sensors is not known. We derive the fundamental precision limit: the extended-channel quantum Cramér-Rao bound. In the experimentally relevant regime in which losses dominate, we prove that non-Gaussian-state preparation and measurement are required to achieve this fundamental limit and we determine numerically the optimal non-Gaussian protocol. We discuss how this scheme could accelerate searches for signatures of quantum gravity, stochastic gravitational waves, and axionic dark matter.

Axions↗

SU-E-I-85: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner

Purpose: To quantify the simulated absorbed dose delivered for a typical scan from a commercially available microCT scanner in order to aid in the dose estimation. Methods: The simulations were conducted using the Geant4 Monte Carlo Toolkit (version 10) with the standard electromagnetic classes. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating the energy fluence and angular distributions of generated photons, spatial dimensions of nominal source-to-object and source-to-detector distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) with a 300 angular spread from the source for the 90 kVp X-ray beams with no additional filtration. The nominal distances from the source to object consisted of three setups: 154.0 mm, 104.0 mm, and 51.96 mm. Our simulations recorded the dose absorbed in a cylindrical phantom of PMMA with a fixed length of 2 cm and varying radii (10, 20, 30 and 40 mm) using 100 million incident photons. The averaged absorbed dose in the object was then quantified for all setups. An exposure measurement of 417 mR was taken using a Radcal 9095 system utilizing 10×9–180 ion chamber with the given technique of 90 kVp, 63 μA, and 12 s. The exposure rate was also simulated with same setup to calculate the conversion factor of the beam current and the number of incident photons. Results: For a typical cone-beam scan with non-filtered 90kVp, the dose coefficients (the absorbed dose per mAs) were 2.614, 2.549 and 2.467 μGy/mAs under source to object distance of 104 mm for the object diameters of 10 mm, 20 mm and 30 mm, respectively. Conclusion: A look-up table was developed where an investigator can estimate the delivered dose using this particular microCT given the scanning protocol (kVp and mAs) as well as the size of the scanned object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-AB-207A-11: Anatomical and Functional Assessment of Coronary Artery Disease Using Low-Dose Whole-Organ Dynamic Computed Tomography

Purpose: To evaluate the accuracy of a low-dose, first-pass-analysis (FPA) dynamic computed tomography angiography and perfusion (CTAP) technique, for whole-organ anatomical and functional assessment of coronary artery disease (CAD). Methods: An angioplasty balloon was advanced into the left anterior descending (LAD) coronary artery of five swine (35–45 kg) to induce several levels of stenosis at maximal hyperemia (intracoronary adenosine, 240 µg/min). Reference fluorescence microspheres and intravenous contrast (370 mg/mL iodine, 25 mL, 7 mL/s) were injected centrally and dynamic imaging was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Twenty volume scans were acquired per stenosis level to capture complete aortic and myocardial enhancement curves, but only two volume scans were used for whole-organ dynamic FPA CTAP measurement. All CTAP measurements in the LAD were compared to the reference microsphere perfusion measurements using linear regression, concordance correlation, and Bland-Altman analysis. Results: The result of dynamic FPA CTAP measurement in the LAD was in good agreement with the reference microsphere perfusion measurement (P-CTAP = 1.01 P-MICRO + 0.16, R{sup 2} = 0.95). The root mean square error (RMSE) and difference (RMSD) of measurement were 0.51 mL/min/g and 0.47 mL/min/g, respectively. Bland-Altman analysis demonstrated negligible systematic measurement bias. Additionally, the concordance correlation coefficient (CCC) was found to be ρ = 0.97, indicating excellent agreement between dynamic FPA CTAP measurement and the reference microsphere perfusion measurement. Lastly, the effective dose of the proposed technique using the “simulated” two-volume scan CTAP acquisition protocol was 2.6 mSv; much lower than the ∼10 mSv effective dose of current dynamic CTP techniques alone. Conclusion: The results indicate the potential for significant improvements in CAD assessment through low-dose, quantitative dynamic FPA CTAP. Such improvements are afforded through whole-organ CT scanning technology, and have the potential to improve patient outcomes and lead to healthier patient lives. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

A 20 Gbps Data Transmitting ASIC with PAM4 for Particle Physics Experiments

We present the design principle and test results of a data transmitting ASIC, GBS20, for particle physics experiments. The goal of GBS20 will be an ASIC that employs two serializers each from the 10.24 Gbps lpGBT SerDes, sharing the PLL also from lpGBT. A PAM4 encoder plus a VCSEL driver will be implemented in the same die to use the same clock system, eliminating the need of CDRs in the PAM4 encoder. This way the transmitter module, GBT20, developed using the GBS20 ASIC, will have the exact lpGBT data interface and transmission protocol, with an output up to 20.48 Gbps over one fiber. With PAM4 embedded FPGAs at the receiving end, GBT20 will halve the fibers needed in a system and better use the input bandwidth of the FPGA. A prototype, GBS20v0 is fabricated using a commercial 65 nm CMOS technology. This prototype has two serializers and a PAM4 encoder sharing the lpGBT PLL, but no user data input. An internal PRBS generator provides data to the serializers. GBS20v0 is tested barely up to 20.48 Gbps. With lessons learned from this prototype, we are designing the second prototype, GBS20v1, that will have 16 user data input channels each at 1.28 Gbps. We present the design concept of the GBS20 ASIC and the GBT20 module, the preliminary test results, and lessons learned from GBS20v0 and the design of GBS20v1 which will be not only a test chip but also a user chip with 16 input data channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of Tape Casting for Fabrication of Li 6.25 Al 0.25 La 3 Zr 2 O 12 Sheets

Tape casting is an attractive technology for the scalable manufacturing of thin lithium garnet electrolyte (LLZO) layers for solid state battery applications. Processing of LLZO is complicated by many factors including lithium volatilization, abnormal grain growth, and phase instability, which are exacerbated by high surface area to volume ratios. In this work a sintering protocol for commercially available Li 6.25 Al 0.25 La 3 Zr 2 O 12 Sheets (Al-LLZO) powder was developed that requires no mother-powder covering or externally applied pressure. MgO was investigated as a sintering additive to improve density and ionic conductivity of the Al-LLZO sheets and produce a fine-grained microstructure. Al-LLZO sheets with 5 wt % MgO had densities of > 90% and ionic conductivity > 2 × 10 -4 S/cm. The optimized ceramic composition and sintering protocol were used to compare several tape casting binder systems. A "green"water-based system using methylcellulose as a binder was developed with green and final properties comparable to those obtained with solvent-based systems.

25 ENERGY STORAGE↗

Novel data analysis method for obtaining better performance from a complex 3D-printed collimator

Additively manufactured scattered beam collimators are increasingly being employed to boost the sample to cell peak signal ratio in high pressure neutron diffraction studies because of manufacturing versatility and performance improvements. We study how the measured diffraction pattern is affected by the presence of a collimator downstream of the sample, and develop a novel protocol that provides more effective background rejection. This protocol takes into account critical performance-determinants that were identified in this study, namely: (i) effectively identifying the collimator pattern on the detector; (ii) understanding the dependence of this pattern on sample and cell composition; and (iii) accurately identifying and differentiating the different regions of the pattern on the detector based on the dependency of the cell or sample and finally (iv) resolving the intensities at regions of the detector where neutrons scattered from the sample are preferentially represented, in order to boost the sample to cell peak signal ratio. Application of this novel analysis protocol is shown to increase the collimator performance over the traditional method.

3D printing↗

FPGA remote update for nuclear environments

The Instituto de Plasmas e Fusao Nuclear (IPFN) has developed dedicated re-configurable modules based on field programmable gate array (FPGA) devices for several nuclear fusion machines worldwide. Moreover, new Advanced Telecommunication Computing Architecture (ATCA) based modules developed by IPFN are already included in the ITER catalogue. One of the requirements for re-configurable modules operating in future nuclear environments including ITER is the remote update capability. Accordingly, this work presents an alternative method for FPGA remote programing to be implemented in new ATCA based re-configurable modules. FPGAs are volatile devices and their programming code is usually stored in dedicated flash memories for properly configuration during module power-on. The presented method is capable to store new FPGA codes in Serial Peripheral Interface (SPI) flash memories using the PCIexpress (PCIe) network established on the ATCA back-plane, linking data acquisition endpoints and the data switch blades. The method is based on the Xilinx Quick Boot application note, adapted to PCIe protocol and ATCA based modules. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

Preoperative Single-Fraction Partial Breast Radiation Therapy: A Novel Phase 1, Dose-Escalation Protocol With Radiation Response Biomarkers

Purpose: Women with biologically favorable early-stage breast cancer are increasingly treated with accelerated partial breast radiation (PBI). However, treatment-related morbidities have been linked to the large postoperative treatment volumes required for external beam PBI. Relative to external beam delivery, alternative PBI techniques require equipment that is not universally available. To address these issues, we designed a phase 1 trial utilizing widely available technology to 1) evaluate the safety of a single radiation treatment delivered preoperatively to the small-volume, intact breast tumor and 2) identify imaging and genomic markers of radiation response. Methods and Materials: Women aged ≥55 years with clinically node-negative, estrogen receptor–positive, and/or progesterone receptor–positive HER2−, T1 invasive carcinomas, or low- to intermediate-grade in situ disease ≤2 cm were enrolled (n=32). Intensity modulated radiation therapy was used to deliver 15 Gy (n=8), 18 Gy (n=8), or 21 Gy (n=16) to the tumor with a 1.5-cm margin. Lumpectomy was performed within 10 days. Paired pre- and postradiation magnetic resonance images and patient tumor samples were analyzed. Results: No dose-limiting toxicity was observed. At a median follow-up of 23 months, there have been no recurrences. Physician-rated cosmetic outcomes were good/excellent, and chronic toxicities were grade 1 to 2 (fibrosis, hyperpigmentation) in patients receiving preoperative radiation only. Evidence of dose-dependent changes in vascular permeability, cell density, and expression of genes regulating immunity and cell death were seen in response to radiation. Conclusions: Preoperative single-dose radiation therapy to intact breast tumors is well tolerated. Radiation response is marked by early indicators of cell death in this biologically favorable patient cohort. This study represents a first step toward a novel partial breast radiation approach. Preoperative radiation should be tested in future clinical trials because it has the potential to challenge the current treatment paradigm and provide a path forward to identify radiation response biomarkers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interface Specifications for RAdiation Portal Technology Enhancement & Replacement (RAPTER) Modules

Radiation Portal Monitors (RPMs) were deployed throughout the port and border infrastructure of the United States (U.S.) beginning in 2003 to monitor for the possible presence of uncontrolled radiological and nuclear materials. Since that time, the U.S. Government (USG) has learned much about the operational challenges faced in the field. Principal among the shortcomings has been the lack of flexibility afforded the USG when all Internet Protocol (IP) rights and interfaces of the system are owned by the Original Equipment Manufacturer (OEM).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology

The integration of adaptive radiation therapy (ART), or modifying the treatment plan during the treatment course, is becoming more widely available in clinical practice. ART offers strong potential for minimizing treatment-related toxicity while escalating or de-escalating target doses based on the dose to organs at risk. Yet, ART workflows add complexity into the radiation therapy planning and delivery process that may introduce additional uncertainties. This work sought to review presently available ART workflows and technological considerations such as image quality, deformable image registration, and dose accumulation. Quality assurance considerations for ART components and minimum recommendations are described. Personnel and workflow efficiency recommendations are provided, as is a summary of currently available clinical evidence supporting the implementation of ART. Finally, to guide future clinical trial protocols, an example ART physician directive and a physics template following standard NRG Oncology protocol is provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fungus mediated synthesis of biomedically important cerium oxide nanoparticles

Graphical abstract: - Highlights: • First time biological synthesis of cerium oxide oxide nanoparticles using fungus Humicola sp. • Complete characterization of cerium oxide nanoparticles. • Biosynthesis of naturally protein capped, luminescent and water dispersible CeO{sub 2} nanoparticles. • Biosynthesized CeO{sub 2} nanoparticles can be used for many biomedical applications. - Abstract: Nanomaterials can be synthesized by chemical, physical and the more recently discovered biological routes. The biological routes are advantageous over the chemical and physical ones as unlike these, the biological synthesis protocols occur at ambient conditions, are cheap, non-toxic and eco-friendly. Although purely biological and bioinspired methods for the synthesis of nanomaterials are environmentally benign and energy conserving processes, their true potential has not been explored yet and attempts are being made to extend the formation of technologically important nanoparticles using microorganisms like fungi. Though there have been reports on the biosynthesis of oxide nanoparticles by our group in the past, no attempts have been made to employ fungi for the synthesis of nanoparticles of rare earth metals or lanthanides. Here we report for the first time, the bio-inspired synthesis of biomedically important cerium oxide (CeO{sub 2}) nanoparticles using the thermophilic fungus Humicola sp. The fungus Humicola sp. when exposed to aqueous solutions of oxide precursor cerium (III) nitrate hexahydrate (CeN{sub 3}O{sub 9}·6H{sub 2}O) results in the extracellular formation of CeO{sub 2} nanoparticles containing Ce (III) and Ce (IV) mixed oxidation states, confirmed by X-ray Photoemission Spectroscopy (XPS). The formed nanoparticles are naturally capped by proteins secreted by the fungus and thus do not agglomerate, are highly stable, water dispersible and are highly fluorescent as well. The biosynthesized nanoparticles were characterized by UV–vis spectroscopy, Photoluminescence spectroscopy (PL), Transmission Electron Microscopy (TEM), Fourier Transform Infrared Spectroscopy (FTIR), X-Ray Diffraction (XRD) and X-ray Photoemission Spectroscopy (XPS)

36 MATERIALS SCIENCE↗

MetaPoL: Immersive VR based Indoor Patterns of Life (PoL) and Anomalies Data Generation for Insider Threat Modeling in Nuclear Security

Insider threats are perhaps the most serious challenges that nuclear and radiological security systems face. Insiders pose such a great threat due to their access, authority, and knowledge, granting them opportunities to bypass dedicated nuclear and radiological security elements. For example, in one of the latest major insider threat incidents to nuclear security, the Doel-4 nuclear powerplant in Belgium suffered a shutdown, the threat of nuclear materials diversion, and long-term loss of tens of millions of dollars. Seven years of investigation concluded that it was an inside job and attempted sabotage. In this regard, there is an immediate need for R&D and technology integration in the domain of modeling indoor Patterns-of-Life (PoL) and anomaly detection. This can be achieved by using datasets of facility users’ mobility and activity, which can support the design of algorithms for insider threat modeling and detection. However, due to classification, privacy, sensitivity, and safety protocols, such datasets from real physical nuclear reactor facilities are not only hard to share, but also not always feasible to deploy and collect. Aiming to find an alternate solution, our proposed demonstration work - MetaPoL, is the first-ever (for the application space) immersive VR (virtual reality) environment of a real-world secure facility and allows users to move-and-stay through the designed indoor physical layout and also encounter NPCs (non-player characters) that emulate other facility users. In the MetaPoL an interactive user performs realistic spatio-temporal movement, dwelling and activities using a Meta Quest Pro VR headset, and that generates high-frequency (in time) high-resolution (in space) indoor spatial-temporal datasets that are valuable for PoL modeling and anomaly detection research specifically for insider threat modeling and detection mission. Such generated realistic, rich in context, and mission specific datasets can boost AI/Machine Learning based research for modeling and detecting insider threats in nuclear security and nonproliferation.

Gunaratne, Chathika↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Protocols for Optimized Fuel Assembly Tags

This report describes the measurement protocols for optimized tags that can be applied to standard fuel assemblies used in light water reactors. This report describes work performed by the authors at Pacific Northwest National Laboratory for NA-22 as part of research to identify specific signatures that can be developed to support counter-proliferation technologies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ANSI and IEC standards for, and evaluation of, radiation detection instrumentation

During the last quarter of 2002, an effort was started to develop performance requirements for radiation instrumentation used for the detection of illicit trafficking of radioactive material. Coordinated by the US National Institute of Science and Technology (NIST), a team was formed to establish writing committees for the development of these requirements as American National Standards Institute (ANSI) standards. The core of the new area was developed as ANSI N42, Homeland Security Instruments. A series of standards were developed followed by testing and evaluation (T&E) protocols that would be used for specific testing. Four US National Laboratories provided T&E support and work commenced to test instruments provided by manufacturers at no cost. During this time, discussions began regarding the formation of a new work group within the International Electrotechnical Commission (IEC). This new work group would be located within technical committee (TC) 45 which addresses nuclear instrumentation. This new work group, 15B, also began developing international standards to address the same instrument types. Following development of ANSI standards, the testing and evaluation process began, running for two distinct rounds. The results of the work was consolidated by NIST and released back to individual companies as well as the user community in a controlled manner. This document will provide details regarding the standards and their basis and status, as well as some information regarding the T&E process used in the USA.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Non-Equilibrium Effects in Quantum Magnets

While most often the state of a material will tend toward an equilibrium determined by its environment, there are many cases of scientific and technological interest where materials are manipulated to be or are found in non-equilibrium configurations. For example, data can be stored in hard drives by deliberately altering the magnetic orientation in a material to store information in non-equilibrium pattern. In this project, the main goals were studies of non-equilibrium properties of quantum magnets using neutron scattering as the primary experimental method. Neutron scattering allows characterization of magnetic correlation lengths sensitive to the presence of defects. It can also be used to distinguish equilibrium from non-equilibrium states via energy transfer rates. Typical bulk state magnetization relaxation times are too short to perform many neutron scattering measurements of interest. To enable the study of non-equilibrium conditions, materials with longer magnetic relaxation times were targeted. CoNb 2 O 6 was used in two experiments related to non-equilibrium physics. In the first, evidence for defects created via the Kibble-Zurek mechanism (KZM) was sought by quenching across a magnetic field-dependent phase transition. Somewhat unexpectedly, clear evidence for KZM-induced defects was absent. Additional measurements of CoNb 2 O 6 were made to better characterize its crystal field and other properties to provide a better theoretical understanding to enable more effective non-equilibrium physics measurements. In another project, LiHo 0.45 Y 0.55 F 4 was used to compare a quantum annealing protocol to a thermal annealing one since magnetic fields can be used to control the thermal fluctuations in LiHo 0.45 Y 0.55 F 4 . In addition, a new pulsed magnet power supply and new techniques were developed suitable for neutron scattering experimental environments to enable faster magnetic field changes for producing non-equilibrium conditions. The power supply developed for this project has wider technological applications in addition to faster magnetic field ramps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗