Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

HIDRA-MAT liquid metal droplet injector for liquid metal applications in HIDRA

A liquid metal droplet injector was explicitly designed for the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT) at the University of Illinois Urbana-Champaign to prepare liquid metal plasma-facing components (PFCs) for plasma exposure. The design goals were to create a compact, reliable, and robust design that could apply liquid metal droplets in-vacuo to a variety of samples. The injector was designed for liquid metal use, and results discussed pertain to lithium. The injector can produce lithium droplets of consistent size by utilizing programmable piston movement. Here, droplet formation data is presented for four different piston step sizes (0.125 mm, 0.25 mm, 0.5 mm, and 1 mm) at three different nozzle temperatures (185 °C, 230 °C, and 270 °C). Droplets are formed on the injector nozzle tip and a linear shift mechanism vertically translates the droplet to the substrate for application. This design prevents the droplet from inadvertently detaching off the nozzle and falling to the sample. Application of the liquid metal droplet ensures placement consistency on the substrate and helps avoid damage to components in HIDRA-MAT that should not interact with liquid metals. A description of the liquid lithium droplet creation and application results is given and provides additional insight into the cooling and oxidation of lithium droplets under vacuum conditions. A second nozzle was fabricated and demonstrated repeatability in droplet diameter creation having a variance of ±0.14 mm for droplets created from the same number of piston steps. The end-use for the injector on HIDRA-MAT is to apply liquid metals to PFCs and expose them to HIDRA's plasma with subsequent intershot in-vacuo surface analysis in HIDRA-MAT for plasma-material interaction studies.

42 ENGINEERING↗

Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis

Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of a Tunable Electromechanical Acoustic Liner for Engine Nacelles

This report describes the development of a tunable electromechanical Helmholtz resonator (EMHR) for engine nacelles using smart materials technology. This effort addresses both near-term and long-term goals for tunable electromechanical acoustic liner technology for the Quiet Aircraft Technology (QAT) Program. Analytical models, i.e. lumped element model (LEM) and transfer matrix (TM) representation of the EMHR, have been developed to predict the acoustic behavior of the EMHR. The models have been implemented in a MATLAB program and used to compare with measurement results. Moreover, the prediction performance of models is further improved with the aid of parameter extraction of the piezoelectric backplate. The EMHR has been experimentally investigated using standard two-microphone method (TMM). The measurement results validated both the LEM and TM models of the EMHR. Good agreement between predicted and measured impedance is obtained. Short- and open circuit loads define the limits of the tuning range using resistive and capacitive loads. There is approximately a 9% tuning limit under these conditions for the non-optimized resonator configuration studied. Inductive shunt loads result in a 3 degree-of-freedom DOF) system and an enhanced tuning range of over 20% that is not restricted by the short- and open-circuit limits. Damping coefficient ' measurements for piezoelectric backplates in a vacuum chamber are also performed and indicate that the damping is dominated by the structural damping losses, such as compliant boundaries, and other intrinsic loss mechanisms. Based on models of the EMHR, a Pareto optimization design of the EMHR has been performed for the EMHR with non-inductive loads. The EMHR with non-inductive loads is a 2DOF system with two resonant fiequencies. The tuning ranges of the two resonant frequencies of the EMHR with non-inductive loads cannot be optimized simultaneously; a trade-off (i.e., a Pareto solution) must be reached. The Pareto solution provides the information for a designer that shows how design trade-offs can be used to satisfy specific design requirements. The optimization design of the EMHR with inductive loads aims at optimal tuning of these three resonant fiequencies. The results indicate that it is possible to keep the acoustic reactance of the resonator close to a constant over a given frequency range. An effort to mimic the second layer of the NASA 2DOF liner using a piezoelectric composite diaphragm has been made. The optimal acoustic reactance of the second layer of the NASA 2DOF liner is achieved using a thin PVDF composite diaphragm, but matching the acoustic resistance requires further investigation. Acoustic energy harvesting is achieved by connecting the EMHR to an energy reclamation circuit that converts the ac voltage signal across the piezoceramic to a conditioned dc signal. Energy harvesting experiment yields 16 m W continuous power for an incident SPL of 153 dB. Such a level is sufficient to power a variety of low power electronic devices. Finally, technology transfer has been achieved by converting the original NASA ZKTL FORTRAN code to a MATLAB code while incorporating the models of the EMHR. Initial studies indicate that the EMHR is a promising technology that may enable lowpower, light weight, tunable engine nacelle liners. This technology, however, is very immature, and additional developments are required. Recommendations for future work include testing of sample EMHR liner designs in NASA Langley s normal incidence dual-waveguide and the grazing-incidence flow facility to evaluating both the impedance characteristics as well as the energy reclamation abilities. Additional design work is required for more complex tuning circuits with greater performance. Poor electromechanical coupling limited the electromechanical tuning capabilities of the proof of concept EMHR. Different materials than those studies and perhaps novel composite material systems may dramatically improvehe electromechanical coupling. Such improvements are essential to improved mimicking of existing double layer liners.

Liu, Fei↗

Investigation of the Impedance Characteristics of Perforate Sheet Hole Clustering Over an Array of Uniform Depth Chambers

A series of normal incidence impedance tube tests are conducted to characterize the facesheet impedance differences between uniformly distributed and nonuniformly tightly packed hole layout patterns, defined here as "hole clustering." These hole clustered samples contain the same number of holes as their uniformly distributed counterparts but target edge to edge distances between holes down to 0.01". Resonant frequency shifts between uniformly distributed and hole clustered samples are presented to demonstrate potential design benefits. Mass end correction differences between samples are also shown to better quantify differences in designs, including the effect of acoustic particle velocity. It is found that hole clustered facesheets over an array of uniform depth chambers can provide significant reactance increases at minimal expense to resistance, thereby lowering resonant frequencies. Additionally, moving these hole clustered layouts toward common chamber corners provides additional resonance shifts to lower frequencies.

acoustic liner impedance hole clustering perforate↗

Multispectral Quantitative Phase Imaging Using a Diffractive Optical Network

As a label‐free imaging technique, quantitative phase imaging (QPI) provides optical path length information of transparent specimens for various applications in biology, materials science, and engineering. Multispectral QPI measures quantitative phase information across multiple spectral bands, permitting the examination of wavelength‐specific phase and dispersion characteristics of samples. Herein, the design of a diffractive processor is presented that can all‐optically perform multispectral quantitative phase imaging of transparent phase‐only objects within a snapshot. The design utilizes spatially engineered diffractive layers, optimized through deep learning, to encode the phase profile of the input object at a predetermined set of wavelengths into spatial intensity variations at the output plane, allowing multispectral QPI using a monochrome focal plane array. Through numerical simulations, diffractive multispectral processors are demonstrated to simultaneously perform quantitative phase imaging at 9 and 16 target spectral bands in the visible spectrum. The generalization of these diffractive processor designs is validated through numerical tests on unseen objects, including thin Pap smear images. Due to its all‐optical processing capability using passive dielectric diffractive materials, this diffractive multispectral QPI processor offers a compact and power‐efficient solution for high‐throughput quantitative phase microscopy and spectroscopy.

36 MATERIALS SCIENCE↗

Novel imaging techniques of rectal cancer: what do radiomics and radiogenomics have to offer? A literature review

Introduction: As computational capabilities have advanced, radiologists and their collaborators have looked for novel ways to analyze diagnostic images. This has resulted in the development of radiomics and radiogenomics as new fields in medical imaging. Radiomics and radiogenomics may change the practice of medicine, particularly for patients with colorectal cancer. Radiomics corresponds to the extraction and analysis of numerous quantitative imaging features from conventional imaging modalities in correlation with several endpoints, including the prediction of pathology, genomics, therapeutic response, and clinical outcome. In radiogenomics, qualitative and/or quantitative imaging features are extracted and correlated with genetic profiles of the imaged tissue. Thus far, several studies have evaluated the use of radiomics and radiogenomics in patients with colorectal cancer; however, there are challenges to be overcome before its routine implementation including challenges related to sample size, model design and interpretability, and the lack of robust multicenter validation set. Material and methods: In this article, we will review the concepts of radiomics and radiogenomics and their potential applications in rectal cancer. Conclusion: Radiologists should be aware of the basic concepts, benefits, pitfalls, and limitations of new radiomic and radiogenomics techniques to achieve a balanced interpretation of the results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photoluminescence of Gallium Phosphide-Based Nanostructures with Germanium Quantum Dots, Grown by Liquid-Phase Epitaxy

We have used liquid-phase epitaxy with pulsed substrate cooling using two structural designs to grow samples of nanoheteroepitaxial structures with Ge quantum dots in a GaP matrix on Si substrates. We have measured the photoluminescence spectra of the samples at temperatures of 77 K and 300 K with excitation by laser emission at λ = 4880 Å and 5145 Å. We draw conclusions concerning the factors influencing the spectrum and intensity of emission for nanostructures with quantum dots. It was found that in order to reduce nonradiative recombination in multilayer p–n structures, we need to create quantum dot arrays inside p and n regions rather than in the central portion of the depletion layer of the p–n junction. We show that the theoretical energies for Ge quantum dots of the calculated sizes are comparable with the energies of their photoluminescence maxima.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characteristics of Non-metallic Inclusions in Steel Obtained from Different-Sized Samplers

To determine the effect of sampler size on the detection of inclusions in liquid steel, four different-sized samplers were designed for industrial sampling from a continuous casting tundish. The samples were evaluated via scanning electron microscopy and energy-dispersive spectroscopy. With increasing sample size, the cooling rate of the sample and velocity for particle engulfment decreased. The extent of encapsulation of complex inclusions increased from 0 pct with the smallest sampler to 48.2 pct with the largest sampler. In the samplers that cooled at 41.2 and 26.7 K s{sup −1}, the major inclusions were calcium aluminates; in the larger samplers, which cooled more slowly at 8.2 and 1.0 K s{sup −1}, the complex inclusions predominately comprised Al{sub 2}O{sub 3} + (Ca, Mn)S and Al{sub 2}O{sub 3} + CaS, respectively. The sizes of the sulfides gradually increased with increasing sampler size; for example, the sulfide average diameter increased from 2.5 to 3.5 μm when the sampler inner diameter increased from 50 to 70 mm. The main direction of movement of the inclusions during the sampling process was upward.

36 MATERIALS SCIENCE↗

TOUGH–RBSN simulator for hydraulic fracture propagation within fractured media: Model validations against laboratory experiments

This study presents coupled hydro-mechanical modeling of hydraulic fracturing processes in complex fractured media using a discrete fracture network (DFN) approach. The individual physical processes in the fracture propagation are represented by separate program modules: the TOUGH2 code for multiphase flow and mass transport based on the finite volume approach; and the rigid-body-spring network (RBSN) model for mechanical and fracture-damage behavior, which are coupled with each other. Fractures are modeled as discrete features, of which the hydrological properties are evaluated from the fracture deformation and aperture change. The verification of the TOUGH–RBSN code is performed against a 2D analytical model for single hydraulic fracture propagation. Subsequently, modeling capabilities for hydraulic fracturing are demonstrated through simulations of laboratory experiments conducted on rock-analogue (soda-lime glass) samples containing a designed network of pre-existing fractures. Sensitivity analyses are also conducted by changing the modeling parameters, such as viscosity of injected fluid, strength of pre-existing fractures, and confining stress conditions. The hydraulic fracturing characteristics attributed to the modeling parameters are investigated through comparisons of the simulation results.

58 GEOSCIENCES↗

Three-dimensional electronic resistivity mapping of solid electrolyte interphase on Si anode materials

Silicon is a promising candidate for the lithium ion battery (LIB) anode because of the order-of-magnitude improvement in capacity over current state-of-the-art graphite anodes. In systems featuring both C and Si anodes, electronic resistivity of the solid-electrolyte interphase (SEI) layer is a critical factor for preventing continuous electrolyte-decomposition reactions at the electrode/electrolyte interface. However, the in-situ measurement of SEI electronic resistance has been complicated by ion transport and electronic contributions from other parts of the battery circuit. Ex-situ measurements of SEI resistivity at microscopic scales are also lacking. We report on a nanometer-resolution three-dimensional technique that enables ex-situ mapping of electronic resistivity of SEI formed on a model single-crystalline wafer Si anode. Our novel experimental approach uses scanning spreading-resistance microscopy resistance imaging and mechanical depth profiling. In addition to resistance mapping, this method also provides an alternative technique for locating buried interfaces, where mechanical or electronic properties differ sufficiently between layers. Further validation of this method was obtained by resistance mapping of a reference sample with a designed a-Si:H layer stack of different doping concentrations. The results show relatively uniform lateral resistivity distribution of the SEIs but steep decreases in resistivity in the vertical direction. Resistivity vs. depth profiles are highly dependent on cycling conditions, but they generally show a resistivity decrease from the most superficial levels of SEI and a thickness increase with continued cycling prior to SEI stabilization. The most prominent resistivity increase was observed on SEI formed in Gen2 electrolyte (EC:EMC [3:7 by wt.] + 1.2 M LiPF6) with 10 wt% fluoroethylene carbonate additive; this result may partially explain the significant improvements of sustained electrochemical cycling and coulombic efficiency observed with this electrolyte additive. Our approach provides a novel and unparalleled three-dimensional approach in characterizing electronic resistivity, which contributes significantly to understanding SEI formation and the intrinsic properties critical to battery performance.

25 ENERGY STORAGE↗

Pressure-Induced Enhancement of Thermoelectric Figure of Merit and Structural Phase Transition in TiNiSn

Half-Heusler thermoelectric materials are potential candidates for high thermoelectric efficiency. Here, we report high-pressure thermoelectric and structural property measurements, density functional theory calculations on the half-Heusler material TiNiSn, and an increase of 15% in the relative dimensionless figure of merit, ZT, around 3 GPa. Thermal and electrical properties were measured utilizing a specialized sample cell assembly designed for the Paris–Edinburgh large-volume press to a maximum pressure of 3.5 GPa. High-pressure structural measurements performed up to 50 GPa in a diamond-anvil cell indicated the emergence of a new high-pressure phase around 20 GPa. A first-principles structure search performed using an ab initio random structure search approach identified the high-pressure phase as an orthorhombic type, in good agreement with the experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Measurement of Li-Ion Concentration and Diffusivity in Solid-State Electrolyte

Here, we present a quantitative method to measure the concentration and diffusivity of Li ion in a solid-state electrolyte with nanoscale depth resolution. We designed a standard sample with different depths of trenches and used time-of-flight secondary ion mass spectroscopy, inductively coupled plasma optical emission spectroscopy, three-dimensional (3D) optical microscopy, and electrochemical strain microscopy to obtain effective Li-ion concentration and the corresponding diffusivity as a function of depth. As a result, we verified the dependence of electromechanical strain induced by ionic oscillation on mobile-ion concentration. We also showed the diffusivity change as a function of effective concentration and discussed the difference in diffusivity near the surface and inside the bulk. Our method can be widely used for electromechanical strain in various ionic conductors, rendering our technique universal for quantitative analysis of ionic dynamics at a multiscale.

36 MATERIALS SCIENCE↗

Structure and thermodynamics of water adsorption in NU-1500-Cr

Abstract Metal-organic frameworks (MOFs) are a class of materials with diverse chemical and structural properties, and have been shown to effectively adsorb various types of guest molecules. The mechanism of water adsorption in NU-1500-Cr, a high-performance atmospheric water harvesting MOF, is investigated using a combination of molecular dynamics simulations and infrared spectroscopy. Calculations of thermodynamic and dynamical properties of water as a function of relative humidity allow for following the adsorption process from the initial hydration stage to complete filling of the MOF pores. Initial hydration begins at the water molecules that saturate the open Cr 3+ sites of the framework, which is then followed by the formation of water chains that extend along the channels connecting the hexagonal pores of the framework. Water present in these channels gradually coalesces and fills the hexagonal pores sequentially after the channels are completely hydrated. The development of hydrogen-bond networks inside the MOF pores as a function of relative humidity is characterized at the molecular level using experimental and computational infrared spectroscopy. A detailed analysis of the OH-stretch vibrational band indicates that the low-frequency tail stems from strongly polarized hydrogen-bonded water molecules, suggesting the presence of some structural disorder in the experimental samples. Strategies for designing efficient water harvesting MOFs are also proposed based on the mechanism of water adsorption in NU-1500-Cr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Composite pressure cell for pulsed magnets

We report that extreme pressures and high magnetic fields can affect materials in profound and fascinating ways. However, large pressures and fields are often mutually incompatible; the rapidly changing fields provided by pulsed magnets induce eddy currents in the metallic components used in conventional pressure cells, causing serious heating, forces, and vibration. Here, we report a diamond-anvil-cell made mainly out of insulating composites that minimizes inductive heating while retaining sufficient strength to apply pressures of up to 8 GPa. Any residual metallic component is made of low-conductivity metals and patterned to reduce eddy currents. The simple design enables rapid sample or pressure changes, desired by pulsed-magnetic-field-facility users. The pressure cell has been used in pulsed magnetic fields of up to 65 T with no noticeable heating at cryogenic temperatures. Several measurement techniques are possible inside the cell at temperatures as low as 500 mK.

47 OTHER INSTRUMENTATION↗

Development of low temperature fuel cell holders for Operando x-ray micro and nano computed tomography to visualize water distribution

Abstract Synchrotron x-ray imaging techniques, like x-ray computed tomography (CT) and radiography have proven instrumental in expanding the communities knowledge of complex transport and reaction kinetics in electrochemical devices such as fuel cells and electrolyzers. This work presents the development of novel x-ray CT imaging techniques for operando visualization of water within low temperature fuel cells at spatial resolutions spanning the micro and nano scales. The design of operando sample holders, for both micro x-ray CT and nano CT experiments is described in depth, and prototypes of these sample holders were evaluated across a set of requirements, the most important of which are x-ray transmissibility, electrical conductivity and mechanical stability. Water segmentation from micro x-ray CT data was enabled by an image subtraction method, where the image without water is subtracted from the one with water. Through iterative experimentations, the operando nano CT cell was developed to optimize mechanical compression, electric conductivity and gas flow. While three-dimensional fuel cell reconstructions were shown possible, there remain challenges to overcome at typical lower energies (8 keV) due to beam damage, whereas it is not as significant for higher energies (>17.5 keV).

Kulkarni, Devashish↗

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of free 25(OH)D concentrations and their relationships to total 25(OH)D in multiple clinical populations

Context The optimal measure of vitamin D status is unknown. Objective To directly measure circulating free 25-hydroxyvitamin D [25(OH)D] concentrations and relationships to total 25(OH)D in a clinically diverse sample of humans. Design Cross-sectional analysis. Setting Seven academic sites. Patients A total of 1661 adults: healthy (n = 279), prediabetic (n = 479), outpatients (n = 714), cirrhotic (n = 90), pregnant (n = 20), nursing home resident (n = 79). Interventions Merge research data on circulating free 25(OH)D (directly-measured immunoassay), total 25(OH)D (liquid chromatography/tandem mass spectrometry), D-binding protein [DBP; by radial (polyclonal) immunodiffusion assay], albumin, creatinine, intact parathyroid hormone, and DBP haplotype. Main outcome measures Distribution of free 25(OH)D (ANOVA with Bonferroni correction for post hoc comparisons) and relationships between free and total 25(OH)D (mixed-effects modeling incorporating clinical condition, DBP haplotype with sex, race, estimated glomerular filtration rate (eGFR), body mass index (BMI), and other covariates). Results Free 25(OH)D was 4.7 ± 1.8 pg/mL (mean ± SD) in healthy persons and 4.3 ± 1.9 pg/mL in outpatients, with levels of 0.5 to 8.1 pg/mL and 0.9 to 8.1 pg/mL encompassing 95% of healthy persons and outpatients, respectively. Free 25(OH)D was higher in patients with cirrhosis (7.1 ± 3.0 pg/mL; P < 0.0033) and nursing home residents (7.9 ± 2.1 pg/mL; P < 0.0033) than in other groups and differed between whites and blacks (P < 0.0033) and between DBP haplotypes (P < 0.0001). Mixed-effects modeling of relationships between free and total 25(OH)D identified clinical conditions (patients with cirrhosis > nursing home residents > patients with prediabetes > outpatients > pregnant women) and BMI (lesser effect) as covariates affecting relationships but not eGFR, sex, race, or DBP haplotype. Conclusions Total 25(OH)D, health condition, race, and DBP haplotype affected free 25(OH)D, but only health conditions and BMI affected relationships between total and free 25(OH)D. Clinical importance of free 25(OH)D needs to be established in studies assessing outcomes.

Schwartz, Janice B.↗