Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Benchmarking sensor fusion capabilities of an integrated instrumentation package

Quantifying and mitigating environmental risks introduced by marine energy conversion systems requires a variety of sensors (active acoustic, passive acoustic, and optical). The operation of these sensors must satisfy three directives to be effective: (1) do not alter the environment through operation of sensors; (2) capture rare events; and (3) do not accrue unmanageable volumes of low-value data. This requires integrating sensors into a single package, rather than operating them independently. The Adaptable Monitoring Package is an integrated instrumentation package that combines a multibeam sonar, acoustic camera, current profiler, optical cameras, and an array of hydrophones. The capabilities and limitations of the AMP sensors were benchmarked using cooperative targets, and real-time target tracking and detection was used to detect opportunistic targets (e.g., diving birds, seals). During an initial deployment, automatic detection of opportunistic targets achieved a 58% true positive rate and a 99% true negative rate (100% corresponding to an ideal system in both cases). In post-processing, target tracking data were used to evaluate automatic target classification capabilities using a k-nearest neighbor algorithm. Findings suggest that real-time target classification should be possible and enable integrated instrumentation systems to meet the monitoring needs of marine energy deployments.

16 TIDAL AND WAVE POWER↗

Thermal dissipation sensors enter a new age: Navigating frontiers in transpiration and hydrologic function

Thermal dissipation (TD) sensors have been used extensively for a wide array of sap flow applications, and yet recently several limitations of this approach have been identified, including a tendency to underestimate absolute flows, especially in small stems with very high flows. However, when used properly, the TD method remains the most cost effective and reliable approach for determining relative flows in comparison studies. Major advantages of this method include the ability to replicate maximally within trees, across trees of different sizes, and across multiple species to capture the full range of natural variation in the study system. From early studies, such variation has been deemed a major challenge for representing stand-level dynamics. In a series of recent comparison studies, we determined mean sap flux density dynamics within and among groups of trees. These studies were conducted within temperate coniferous forest (n=46), temperate oak savanna (n=36), temperate pine forest (n=49), temperate bottomland hardwood forest (n=23), tropical premontane rainforest (n=43), semiarid subtropical shrubland (n=25), and tropical dry forest (n=15), with a total of 237 sensors. Two study sites were also equipped with eddy covariance systems for determination of stand-level evapotranspiration. Sites subject to high background thermal gradients used the transient thermal dissipation method. Comparisons varied between studies but tended to focus on relative flow differences between species, between wetter and drier microsites, between understory and overstory components, or between wetter and drier periods of the growing season. Except for the shrubland sites, study trees tended to be at least 15-cm diameter and frequently exceeded 50-cm diameter. Results of this cross-site comparison highlight the inherent variation in natural stands and the importance of using large sample sizes. The TD approach remains a valuable and preferred method for the future determination of water use in trees. However, sensor replication can fundamentally impact a study's outcomes and should be more carefully considered in study design. Customized error mitigation strategies are best to address the sources of variation most problematic for a particular study. In conclusion, the development of “smart” calibration approaches that correct for fundamental effects of radial variation inherent in thermal dissipation studies is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

AUTHENTICATED SENSOR INTERFACE DEVICE FOR JOINT USE SAFEGUARDS APPLICATIONS - CONCEPTS AND CHALLENGES

This paper will discuss the key features of the Authenticated Sensor Interface Device that collectively provide the ability to share data among a number of parties while ensuring the authentication of data and protecting both the operator’s and the IAEA’s interests. The paper will also discuss the development of the prototype, the initial testing with an accountancy scale, and future plans and challenges to implementation into the joint use and remote monitoring applications. As nuclear fuel cycle technology becomes more prevalent throughout the world and the capacity of plants increases, limited resources of the IAEA are being stretched near a breaking point. A strategy is to increase efficiency in safeguards monitoring using “joint use” equipment that will provide the facility operator process data while also providing the IAEA key safeguards data. The data, however, must be authenticated and validated to ensure the data have not been tampered with. The Authenticated Sensor Interface Device provides the capability to share data and can be a valuable component in the IAEA’s ability to collect accountancy data from scales in Uranium conversion and enrichment plants, as well as nuclear fuel fabrication plants. Likewise, the Authenticated Sensor Interface Device can be configured to accept a diverse array of input signals, ranging from analog voltage, to current, to digital interfaces and more. These modular capabilities provide the ability to collect authenticated, joint-use, data streams from various process monitoring sensors.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Extreme Carrier Depletion and Superlinear Photoconductivity in Ultrathin Parallel-Aligned ZnO Nanowire Array Photodetectors Fabricated by Infiltration Synthesis

Ultrathin semiconductor nanowires enable high-performance chemical sensors and photodetectors, but their synthesis and device integration by standard complementary metal-oxide-semiconductor (CMOS)-compatible processes remain persistent challenges. This work demonstrates fully CMOS-compatible synthesis and integration of parallel-aligned polycrystalline ZnO nanowire arrays into ultraviolet photodetectors via infiltration synthesis, material hybridization technique derived from atomic layer deposition. The nanowire photodetector features unique, high device performances originating from extreme charge carrier depletion, achieving photoconductive on–off ratios of >6 decades, blindness to visible light, and ultralow dark currents as low as 1 fA, the lowest reported for nanostructure-based photoconductive photodetectors. Surprisingly, the low dark current is invariant with increasing number of nanowires and the photodetector shows unusual superlinear photoconductivity, observed for the first time in nanowires, leading to increasing detector responsivity and other parameters for higher incident light powers. Temperature-dependent carrier concentration and mobility reveal the photoelectrochemical-thermionic emission process at grain boundaries, responsible for the observed unique photodetector performances and superlinear photoconductivity. Here, the results elucidate fundamental processes responsible for photogain in polycrystalline nanostructures, providing useful guidelines for developing nanostructure-based detectors and sensors. Lastly, the developed fully CMOS-compatible nanowire synthesis and device fabrication methods also have potentials for scalable integration of nanowire sensor devices and circuitries.

36 MATERIALS SCIENCE↗

Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Physical Protection Systems Test Bed for International Counter-Trafficking System Development

Physical protection systems have a widespread impact on the nuclear industry in areas such as nuclear safeguards, arms control, and trafficking of illicit goods (e.g., nuclear materials) across international borders around the world. Many challenges must be overcome in design and deployment of foreign border security systems such as lack of infrastructure, extreme environmental conditions, limited knowledge of terrain, insider threats, and occasional cultural resistance. Successful security systems, whether it be a system designed to secure a single facility or a whole border security system, rely on the entire integrated system composed of multiple subsystems. This test bed is composed of many unique sensors and subsystems, including wireless unattended ground sensors, a buried fiber-optic acoustic sensor, a lossy coaxial distributed sensor, wireless links, pan-tilt-zoom cameras, mobile power generation systems, unmanned aerial vehicles, and fiber-optic-fence intrusion detection systems. A Common Operating Picture software architecture is utilized to integrate a number of these subsystems. We are currently performance testing each system for border security and perimeter security applications by examining metrics such as probability of sense and a qualitative understanding of the sensor s vulnerability of defeat. The testing process includes different soil conditions for buried sensors (e.g., dry, wet, and frozen) and an array of different tests including walking, running, stealth detection, and vehicle detection. Also, long term sustainability of systems is tested including performance differences due to seasonal variations (e.g. summer versus winter, while raining, in foggy conditions). The capabilities of the test bed are discussed. Performance testing results, both at the individual component level and integrated into a larger system for a specific deployment (in situ), help illustrate the usefulness and need for integrated testing facilities to carry out this mission. The test bed provides access to grassy fields, wooded areas, and a large waterway three distinct testing environments. The infrastructure supporting deployment of systems at the test bed includes grid power, renewable power systems, climate controlled enclosures, high bandwidth wireless links, and a fiber optic communications backbone. With over 10 acres of dedicated area and direct waterway access, the test bed is well suited for long term test and evaluation of physical protection and security systems targeting a wide range of applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thickness dependent self limiting 1-D tin oxide nanowire arrays by nanosecond pulsed laser irradiation

Fast, sensitive and discriminating detection of hydrogen at room temperature is crucial for storage, transportation, and distribution of hydrogen as an energy source. One dimensional nanowires of SnO2 are potential candidates for improved H2 sensor performance. The single directional conducting continuous nanowires can decrease electrical noise, and their large active surface area could improve the response and recovery time of the sensor. In this work we discuss synthesis and characterization of nanowire arrays made using nanosecond ultraviolet wavelength (266 nm) laser interference processing of ultrathin SnO2 films on SiO2 substrates. The laser energy was chosen to be above the melting point of the films. The results show that the final nanowire formation is dominated by preferential evaporation as compared to thermocapillary flow. The nanowire height (and hence wire aspect ratio) increased with increasing initial film thickness ho and with increasing laser energy density Eo. Furthermore, a self-limiting effect was observed where-in the wire formation ceased at a specific final remaining thickness of SnO2 that was almost independent of ho for a given Eo. To understand these effects, finite element modeling of the nanoscale laser heating was performed. This showed that the temperature rise under laser heating was a strong non-monotonic function of film thickness. As a result, the preferential evaporation rate varies as wire formation occurs, eventually leading to a shut-off of evaporation at a characteristic thickness. This results in the stoppage of wire formation. This combination of nanosecond pulsed laser experiments and thermal modeling shows that several unique synthesis approaches can be utilized to control the nanowire characteristics.

08 HYDROGEN↗

Design Optimization for Printed Melt Wire Arrays Encapsulation

As part of the Nuclear Energy Enabling Technology (NEET) Advanced Sensor and Instrumentation (ASI) Program, Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced-manufactured sensors for measuring peak irradiation temperature within a nuclear test reactor. Although methods of real-time temperature monitoring, such as thermocouples, may be used, the complexity of feedthroughs and attachments to collect real-time measurements greatly increases the cost of the experiment. Instead, passive monitoring techniques may be used for peak- temperature measurement that exploit the melting point of well-characterized materials (standard melt wires) to infer peak reactor temperatures. However, limited available space for instrumentation during experiments introduces an additional challenge. To accommodate this, INL has expanded its temperature- detection instrumentation capabilities to include advanced manufactured (AM) melt wires for peak irradiation temperature measurements. These melt wires can determine peak temperatures while also accommodate space limitations in irradiation experiments. In an effort to improve performance reliability of AM meltwire capabilities, a process was developed and tested to identify the significance of entrapping a high purity inert atmosphere within the packaging of printed melt wire arrays. The materials used in this study were aluminum, zinc, and tin encapsulated in high purity helium within a stainless steel (SS) 316 container. Tin, with a low melting point of approximately 230°C, Zn with a mid-melting point of approximately 420°C, and Al with a high melting point of approximately 660°C. This report describes the design, fabrication process, furnace testing and X-ray Computed Tomography (XCT) evaluation. Results show a successful outcome in creating an inert gas encapsulation and high-resolution evaluation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal design of microseismic monitoring network: Synthetic study for the Kimberlina CO2 storage demonstration site

Microseismic monitoring can play a crucial role to ensure safe long-term geological carbon storage. For reliable long-term monitoring for CO2-injection-induced microseismic events, a surface seismic array is desirable in addition to borehole geophone sensors. Optimal design of surface seismic network is of great interest to achieve cost-effective monitoring. We develop a methodology to determine the optimal number of surface seismic stations with a geometrically satisfactory distribution for given monitoring regions. We design an optimal microseismic monitoring network based on widely-accepted guiding principles, and the relationship between the location accuracy of microseismic events and the total number of seismic stations. We determine the optimal number of seismic stations based on the trade-off curve of the event location accuracy vs. the total number of seismic stations. We apply our optimal design method to the Kimberlina carbon storage site in California. We use a synthetic Kimberlina model to show that approximately 20 surface seismic stations with a geometrically satisfactory distribution are preferred for the best trade-off between the cost and the event location accuracy.

58 GEOSCIENCES↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Designing Piezoelectric Films for Micro Electromechanical Systems

Piezoelectric thin films are of increasing interest in low-voltage micro electromechanical systems for sensing, actuation, and energy harvesting. They also serve as model systems to study fundamental behavior in piezoelectrics. Next-generation technologies such as ultrasound pill cameras, flexible ultrasound arrays, and energy harvesting systems for unattended wireless sensors will all benefit from improvements in the piezoelectric properties of the films. This paper describes tailoring the composition, microstructure, orientation of thin films, and substrate choice to optimize the response. It is shown that increases in the grain size of lead-based perovskite films from 75 to 300 nm results in 40 and 20% increases in the permittivity and piezoelectric coefficients, respectively. This is accompanied by an increase in the nonlinearity in the response. Band excitation piezoresponse force microscopy was used to interrogate the nonlinearity locally. It was found that chemical solution-derived PbZr(0.52)Ti(0.48)O(3) thin films show clusters of larger nonlinear response embedded in a more weakly nonlinear matrix. The scale of the clusters significantly exceeds that of the grain size, suggesting that collective motion of many domain walls contributes to the observed Rayleigh behavior in these films. Finally, it is shown that it is possible to increase the energy-harvesting figure of merit through appropriate materials choice, strong imprint, and composite connectivity patterns.

Trolier-McKinstry, Susan↗

Microscale, printed LEDs for unusual lighting and display systems

Current technology development in light emitting diodes has enabled high efficiency operation, low energy consumption and lifetimes, thereby creating new possibilities in conventional display and lighting industry. Recent work is also creating more unusual uses in biomedicine and in sensing applications, where conformal contact over curvilinear surfaces is required. Here, ultrathin device geometries and optimized mechanical designs, including neutral mechanical plane layouts and serpentine interconnects, provide indicators and lighting modules with arbitrary shapes capable of integrated on nearly any type of substrates. Furthermore, biomedical devices such as light emitting suture threads, and glove-mounted optical proximity sensors demonstrate the versatility of this strategy and create great new opportunities.

42 ENGINEERING↗

Sci—Fri PM: Dosimetry—06: Commissioning of a 3D patient specific QA system for hypofractionated prostate treatments

The objective of this work is to commission the 6MV-SRS beam model in COMPASS (v2.1, IBA-Dosimetry) and validate its use for patient specific QA of hypofractionated prostate treatments. The COMPASS system consists of a 2D ion chamber array (MatriXX{sup Evolution}), an independent gantry angle sensor and associated software. The system can either directly calculate or reconstruct (using measured detector responses) a 3D dose distribution on the patient CT dataset for plan verification. Beam models are developed and commissioned in the same manner as a beam model is commissioned in a standard treatment planning system. Model validation was initially performed by comparing both COMPASS calculations and reconstructions to measured open field beam data. Next, 10 hypofractionated prostate RapidArc plans were delivered to both the COMPASS system and a phantom with ion chamber and film inserted. COMPASS dose distributions calculated and reconstructed on the phantom CT dataset were compared to the chamber and film measurements. The mean (± standard deviation) difference between COMPASS reconstructed dose and ion chamber measurement was 1.4 ± 1.0%. The maximum discrepancy was 2.6%. Corresponding values for COMPASS calculation were 0.9 ± 0.9% and 2.6%, respectively. The average gamma agreement index (3%/3mm) for COMPAS reconstruction and film was 96.7% and 95.3% when using 70% and 20% dose thresholds, respectively. The corresponding values for COMPASS calculation were 97.1% and 97.1%, respectively. Based on our results, COMPASS can be used for the patient specific QA of hypofractionated prostate treatments delivered with the 6MV-SRS beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atmosphere-Biosphere Interaction Study (Field Campaign Report)

The objective of this campaign was to collect hyperspectral reflectance measurements and complementary optical and infrared data of land surface (i.e., vegetation and soil) throughout the growing season (i.e., from March to September) at high temporal frequency (e.g., < 30 minutes). To collect the measurements, the EcoSpec system, a tower-based sensor system housing seven optical and infrared sensors that was developed at Argonne National Laboratory, was deployed to the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) atmospheric observatory (within the crop, south of the eddy correlation flux measurement system [ECOR] tower). The EcoSpec system consists of a spectroradiometer having 2,151 channels (350–2,500 nm), red-greenblue (RGB) camera, diffuse radiometer, thermal infrared (TIR) sensors, albedometers, Photochemical Reflectance Index (PRI) sensors, Normalized Difference Vegetation Index (NDVI) sensors, and wetness sensor. The system is designed to collect an array of land surface measurements, including hyperspectral reflectance of plants and soils, RGB photos capturing contextual information of land surface, radiant temperature of sky and land surface, incoming and reflected shortwave radiation, and incoming radiation components (direct and diffuse) as frequent as every minute from up to 12 discrete positions around the tower. This would allow us to capture inherent heterogeneity of the terrestrial ecosystem and to obtain representative spectral signatures of the plant and soil surfaces via averaging those measurements. The SGP site provides advanced atmospheric and other physical measurements that are essential for our investigation of ecosystem functions using hyperspectral reflectance measurements of land surfaces. Located in the mid-latitudes, the SGP site exhibits dynamic seasonality and a wide range of meteorological variability and flux properties that make it ideal for studying interactions between near-surface atmosphere and biosphere across a range of environmental conditions. The atmosphere, plants, and soil control terrestrial carbon and water cycles. To make more accurate climate forecasts, researchers need to understand ecosystem dynamics at the biosphere–atmosphere interface. Even though our ability to forecast ecosystem dynamics and climate at both the regional and global scales has advanced significantly, we still do not know how local phenomena affecting water and carbon fluxes—such as diurnal variations—interrelate with large-scale atmospheric/climate phenomena, and vice versa. The lack of a more thorough understanding of ecosystem dynamics and climate interactions is a key knowledge gap for the improvement of earth system models (ESMs).

54 ENVIRONMENTAL SCIENCES↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoporous framework materials interfaced with mechanical sensors for highly-sensitive chemical sensing.

We will describe how novel nanoporous framework materials (NFM) such as metal-organic frameworks (MOFs) can be interfaced with common mechanical sensors, such as surface acoustic wave (SAW), microcantilever array, and quartz crystal microbalance (QCM) devices, and subsequently be used to provide selectivity and sensitivity to a broad range of analytes including explosives, nerve agents, and volatile organic compounds (VOCs). NFM are highly ordered, crystalline materials with considerable synthetic flexibility resulting from the presence of both organic and inorganic components within their structure. Chemical detection using micro-electro-mechanical-systems (MEMS) devices (i.e. SAWs, microcantilevers) requires the use of recognition layers to impart selectivity. Unlike traditional organic polymers, which are dense, the nanoporosity and ultrahigh surface areas of NFM allow for greater analyte uptake and enhance transport into and out of the sensing layer. This enhancement over traditional coatings leads to improved response times and greater sensitivity, while their ordered structure allows chemical tuning to impart selectivity. We describe here experiments and modeling aimed at creating NFM layers tailored to the detection of water vapor, explosives, CWMD, and volatile organic compound (VOCs), and their integration with the surfaces of MEMS devices. Molecular simulation shows that a high degree of chemical selectivity is feasible. For example, a suite of MOFs can select for strongly interacting organics (explosives, CWMD) vs. lighter volatile organics at trace concentrations. At higher gas pressures, the CWMD are deselected in favor of the volatile organics. We will also demonstrate the integration of various NFM on the surface of microcantiliver arrays, QCM crystals, and SAW devices, and describe new synthetic methods developed to improve the quality of NFM coatings. Finally, MOF-coated MEMS devices show how temperature changes can be tuned to improve response times, selectivity, and sensitivity.

36 MATERIALS SCIENCE↗