Search NASA⌕ Search

SEARCH · Search NASA

Results for “signal analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Analysis and testing of a new method for drop size and velocity measurements using laser light scatter interferometry

Drop size and velocity can be measured simultaneously using an optical system which is the same as a laser Doppler velocimeter except that three detectors are located at selected spacings behind the receiver aperture. Drops passing through the intersection of the two beams scatter light which produces an interferrence fringe pattern. The temporal frequency of the fringe pattern is the Doppler difference frequency which is linearly proportional to the drop velocity while the spatial frequency is linearly related to the drop diameter. The spacing of the fringes is also dependent upon the light wavelength, beam intersection angle, drop refractive index (unless reflected light is measured), and the location of the receiver. The theoretical analysis was verified, signal phase processing methods were evaluated, and the effects of signal quality upon the measurements were investigated.

Bachalo, W. D.↗

Pulsar timing and general relativity

Techniques are described for accounting for relativistic effects in the analysis of pulsar signals. Design features of instrumentation used to achieve millisecond accuracy in the signal measurements are discussed. The accuracy of the data permits modeling the pulsar physical characteristics from the natural glitches in the emissions. Relativistic corrections are defined for adjusting for differences between the pulsar motion in its spacetime coordinate system relative to the terrestrial coordinate system, the earth's motion, and the gravitational potentials of solar system bodies. Modifications of the model to allow for a binary pulsar system are outlined, including treatment of the system as a point mass. Finally, a quadrupole model is presented for gravitational radiation and techniques are defined for using pulsars in the search for gravitational waves.

Backer, D. C.↗

Automatic Frequency Control For DMSK Receiver

Report discusses performance of automatic frequency-control (AFC) subsystem of differential minimum-shift-keying receiver described in "DMSK Receiver for Moblile/Satellite Service," NPO-16659. Describes efforts to quantify behavior of system during acquisition of carrier signal; including theoretical analysis leading to numerical simulation, and measurements of performance of receiving equipment.

Davarian, Faramaz↗

Applicability of mathematical modeling to problems of environmental physiology

The paper traces the evolution of mathematical modeling and systems analysis from terrestrial research to research related to space biomedicine and back again to terrestrial research. Topics covered include: power spectral analysis of physiological signals; pattern recognition models for detection of disease processes; and, computer-aided diagnosis programs used in conjunction with a special on-line biomedical computer library.

White, Ronald J.↗

Terrestrial implications of mathematical modeling developed for space biomedical research

This paper summarizes several related research projects supported by NASA which seek to apply computer models to space medicine and physiology. These efforts span a wide range of activities, including mathematical models used for computer simulations of physiological control systems; power spectral analysis of physiological signals; pattern recognition models for detection of disease processes; and computer-aided diagnosis programs.

Lujan, Barbara F.↗

Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

Hall, David G.↗

Development of a Rayleigh scattering system for temperature measurements in combustor flows

A dual line laser induced Rayleigh scattering system has been developed to be used in high temperature gas flows such as in combustors, and preliminary tests have been performed in a hot air jet. The qualification measurements included the collection and analysis of Rayleigh signal for time-resolved gas temperature over the two lines of a copper-vapor laser. The dual line signal collection technique is a feature to be used in detecting and discriminating the surface scattered laser light in the Rayleigh signal. Optical fibers are used to transmit the laser beam to the optical probe bench and to carry the collected signal from the bench to the housing of the signal sensors. Incident laser intensity at the probe volume is measured for both lines at each pulse of the laser. This information is used to normalize the signal. Good agreement has been obtained between the two line Rayleigh scattering and thermocouple results in the particle free co-flowing air jet.

Otugen, M. V.↗

Frequency-dependent FDTD methods using Z transforms

While the frequency-dependent finite-difference time-domain, or (FD)2TD, method can correctly calculate EM propagation through media whose dielectric properties are frequency-dependent, more elaborate applications lead to greater (FD)2TD complexity. Z-transform theory is presently used to develop the mathematical bases of the (FD)2TD method, simultaneously obtaining a clearer formulation and allowing researchers to draw on the existing literature of systems analysis and signal-processing.

Sullivan, Dennis M.↗

Dual-Use Space Technology Transfer Conference and Exhibition, Volume 1

This document contains papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; new ways of doing business; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; ans robotics technologies. More than 77 papers, 20 presentations, and 20 exhibits covering various disciplines were presented b experts from NASA, universities, and industry.

Kumar Krishen↗

Dual-Use Space Technology Transfer Conference and Exhibition

This is the second volume of papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools; systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development; perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; and robotics technologies.

Krishen, Kumar↗

Flight Control System Design with Rate Saturating Actuators

Actuator rate saturation is an important factor adversely affecting the stability and performance of aircraft flight control systems. It has been identified as a catalyst in pilot-induced oscillations, some of which have been catastrophic. A simple design technique is described that utilizes software rate limiters to improve the performance of control systems operating in the presence of actuator rate saturation. As described, the technique requires control effectors to be ganged such that any effector is driven by only a single compensated error signal. Using an analysis of the steady-state behavior of the system, requirements are placed upon the type of the loop transmissions and compensators in the proposed technique. Application of the technique to the design of a multi-input/multi-output, lateral-directional control system for a simple model of a high-performance fighter is demonstrated as are the stability and performance improvements that can accrue with the technique.

Hess, R. A.↗

Noncontact Acousto-Ultrasonics for Material Characterization

A NdYAG 1064 nm, laser pulse was employed to produce ultrasonic waves in specimens of SiC/SiC and SiC/Ti 6-4 composites which are high temperature materials of interest for aerospace applications. Air coupled transducers were used to detect and collect the signals used for acousto-ultrasonic analysis. Conditions for detecting ultrasonic decay signals were examined. The results were compared to those determined on the same specimens with contact coupling. Some non-contact measurements were made employing conventional air focused detectors. Others were performed with a more novel micromachined capacitance transducer. Concerns of the laser-in technology include potential destructiveness of the laser pulse. Repeated laser pulsing at the same location does lead to deterioration of the ultrasonic signal in some materials, but seems to recover with time. Also, unlike contact AU, the frequency regime employed is a function of laser-material interaction rather than the choice of transducers. Concerns of the air coupled-out technology include the effect of air attenuation. This imposes a practical upper limit to frequency of detection. In the case of the experimental specimens studied ultrasonic decay signals could be imaged satisfactorily.

Kautz, Harold E.↗

Measurement of Trailing Edge Noise Using Directional Array and Coherent Output Power Methods

The use of a directional (or phased) array of microphones for the measurement of trailing edge (TE) noise is described and tested. The capabilities of this method arc evaluated via measurements of TE noise from a NACA 63-215 airfoil model and from a cylindrical rod. This TE noise measurement approach is compared to one that is based on thc cross spectral analysis of output signals from a pair of microphones placed on opposite sides of an airframe model (COP method). Advantages and limitations of both methods arc examined. It is shown that the microphone array can accurately measures TE noise and captures its two-dimensional characteristic over a large frequency range for any TE configuration as long as noise contamination from extraneous sources is within bounds. The COP method is shown to also accurately measure TE noise but over a more limited frequency range that narrows for increased TE thickness. Finally, the applicability and generality of an airfoil self-noise prediction method was evaluated via comparison to the experimental data obtained using the COP and array measurement methods. The predicted and experimental results are shown to agree over large frequency ranges.

Hutcheson, Florence V.↗

Measurement Of Trailing Edge Noise using Directional Array and Coherent Output Power Methods

The use of a directional array of microphones for the measurement of trailing edge (TE) noise is described. The capabilities of this method are evaluated via measurements of TE noise from a NACA 63-215 airfoil model and from a cylindrical rod. This TE noise measurement approach is compared to one that is based on the cross spectral analysis of output signals from a pair of microphones (COP method). Advantages and limitations of both methods are examined. It is shown that the microphone array can accurately measures TE noise and captures its two-dimensional characteristic over a large frequency range for any TE configuration as long as noise contamination from extraneous sources is within bounds. The COP method is shown to also accurately measure TE noise but over a more limited frequency range that narrows for increased TE thickness. Finally, the applicability and generality of an airfoil self-noise prediction method was evaluated via comparison to the experimental data obtained using the COP and array measurement methods. The predicted and experimental results are shown to agree over large frequency ranges.

Hutcheson, Florence V.↗

Up-regulation of phosphoinositide metabolism in tobacco cells constitutively expressing the human type I inositol polyphosphate 5-phosphatase

To evaluate the impact of suppressing inositol 1,4,5-trisphosphate (InsP(3)) in plants, tobacco (Nicotiana tabacum) cells were transformed with the human type I inositol polyphosphate 5-phosphatase (InsP 5-ptase), an enzyme which specifically hydrolyzes InsP(3). The transgenic cell lines showed a 12- to 25-fold increase in InsP 5-ptase activity in vitro and a 60% to 80% reduction in basal InsP(3) compared with wild-type cells. Stimulation with Mas-7, a synthetic analog of the wasp venom peptide mastoparan, resulted in an approximately 2-fold increase in InsP(3) in both wild-type and transgenic cells. However, even with stimulation, InsP(3) levels in the transgenic cells did not reach wild-type basal values, suggesting that InsP(3) signaling is compromised. Analysis of whole-cell lipids indicated that phosphatidylinositol 4,5-bisphosphate (PtdInsP(2)), the lipid precursor of InsP(3), was greatly reduced in the transgenic cells. In vitro assays of enzymes involved in PtdInsP(2) metabolism showed that the activity of the PtdInsP(2)-hydrolyzing enzyme phospholipase C was not significantly altered in the transgenic cells. In contrast, the activity of the plasma membrane PtdInsP 5 kinase was increased by approximately 3-fold in the transgenic cells. In vivo labeling studies revealed a greater incorporation of (32)P into PtdInsP(2) in the transgenic cells compared with the wild type, indicating that the rate of PtdInsP(2) synthesis was increased. These studies show that the constitutive expression of the human type I InsP 5-ptase in tobacco cells leads to an up-regulation of the phosphoinositide pathway and highlight the importance of PtdInsP(2) synthesis as a regulatory step in this system.

NASA Discipline Cell Biology↗

Waveform Based Acoustic Emission Detection and Location of Matrix Cracking in Composites

The operation of damage mechanisms in a material or structure under load produces transient acoustic waves. These acoustic waves are known as acoustic emission (AE). In composites they can be caused by a variety of sources including matrix cracking, fiber breakage, and delamination. AE signals can be detected and analyzed to determine the location of the acoustic source by triangulation. Attempts are also made to analyze the signals to determine the type and severity of the damage mechanism. AE monitoring has been widely used for both laboratory studies of materials, and for testing the integrity of structures in the field. In this work, an advanced, waveform based AE system was used in a study of transverse matrix cracking in cross-ply graphite/epoxy laminates. This AE system featured broad band, high fidelity sensors, and high capture rate digital acquisition and storage of acoustic signals. In addition, analysis techniques based on plate wave propagation models were employed. These features provided superior source location and noise rejection capabilities.

Prosser, W. H.↗

T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

Non-NASA Center↗