Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial correlations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Holographic Quantum States

We show how continuous matrix product states of quantum fields can be described in terms of the dissipative nonequilibrium dynamics of a lower-dimensional auxiliary boundary field by demonstrating that the spatial correlation functions of the bulk field correspond to the temporal statistics of the boundary field. This equivalence (1) illustrates an intimate connection between the theory of continuous quantum measurement and quantum field theory, (2) gives an explicit construction of the boundary field allowing the extension of real-space renormalization group methods to arbitrary dimensional quantum field theories without the introduction of a lattice parameter, and (3) yields a novel interpretation of recent cavity QED experiments in terms of quantum field theory, and hence paves the way toward observing genuine quantum phase transitions in such zero-dimensional driven quantum systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Denaturation of DNA Studied with Neutron Scattering

The melting transition of DNA, whereby the strands of the double-helix structure completely separate at a certain temperature, has been characterized using neutron scattering. A Bragg peak from B-form fiber DNA has been measured as a function of temperature, and its widths and integrated intensities have been interpreted using the Peyrard-Bishop-Dauxois model with only one free parameter. The experiment is unique, as it gives spatial correlation along the molecule through the melting transition where other techniques cannot.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Subdiffusion in a Disordered Interacting System

We study the transport dynamics of matter-waves in the presence of disorder and nonlinearity. An atomic Bose-Einstein condensate that is localized in a quasiperiodic lattice in the absence of atom-atom interaction shows instead a slow expansion with a subdiffusive behavior when a controlled repulsive interaction is added. The measured features of the subdiffusion are compared to numerical simulations and a heuristic model. The observations confirm the nature of subdiffusion as interaction-assisted hopping between localized states and highlight a role of the spatial correlation of the disorder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Size-Tuned Plastic Flow Localization in Irradiated Materials at the Submicron Scale

Three-dimensional discrete dislocation dynamics (3D-DDD) simulations reveal that, with reduction of sample size in the submicron regime, the mechanism of plastic flow localization in irradiated materials transitions from irradiation-controlled to an intrinsic dislocation source controlled. Furthermore, the spatial correlation of plastic deformation decreases due to weaker dislocation interactions and less frequent cross slip as the system size decreases, thus manifesting itself in thinner dislocation channels. A simple model of discrete dislocation source activation coupled with cross slip channel widening is developed to reproduce and physically explain this transition. In order to quantify the phenomenon of plastic flow localization, we introduce a “deformation localization index,” with implications to the design of radiation-resistant materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interferometric Constraints on Spacelike Coherent Rotational Fluctuations

Precision measurements are reported of the cross-spectrum of rotationally induced differential position displacements in a pair of colocated 39 m long, high-power Michelson interferometers. One arm of each interferometer is bent 90° near its midpoint to obtain sensitivity to rotations about an axis normal to the plane of the instrument. The instrument achieves quantum-limited sensing of spatially correlated signals in a broad frequency band extending beyond the 3.9-MHz inverse light travel time of the apparatus. For stationary signals with bandwidth Δf>10 kHz, the sensitivity to rotation-induced strain h of classical or exotic origin surpasses CSDδh

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transitions in the morphology and critical stresses of gliding dislocations in multiprincipal element alloys

Refractory multiprincipal element alloys (MPEAs) are promising material candidates for high-temperature, high-strength applications. However, their deformation mechanisms, particularly at the dislocation scale, are unusual compared to those of conventional alloys, making it challenging to understand the origin of their high strength. Here, using an atomistically informed phase-field dislocation dynamics model, we study transitions in the morphology and critical stresses of long gliding screw dislocations over extended distances in a refractory MPEA. The model MPEA crystal accounts for the atomic-scale fluctuations in chemical composition across the glide planes via spatially correlated lattice energies and for the differences in glide resistances between screw and edge dislocations of unit length. Here, we show that the dislocation moves in a stop-start motion, alternating between wavy morphology in free flight and nearly recovered straight screw orientation in full arrest. The periods of wavy glide are due to variable kink-pair formation and migration rates along the length, where portions with higher rates glide more quickly. The critical stress to initiate motion corresponds to the stress required to form and migrate a kink pair at the weakest region along the length of the dislocation. Heterogeneity in lattice energy leads to variability in the local stress-strain response and to a strain hardening-like response, in which the critical stress to reactivate glide increases with glide distance. Statistical assessment of hundreds of realizations of dislocations indicates that the amount of hardening directly scales with the dispersion in underlying lattice energy.

3-dimensional systems↗

Tensor network simulations of quasi-GPDs in the massive Schwinger model

Generalized parton distribution functions (GPDs) are off-diagonal light-cone matrix elements that encode the internal structure of hadrons in terms of quark and gluon degrees of freedom. In this work, we present the first nonperturbative study of quasi-GPDs in the massive Schwinger model, quantum electrodynamics in 1+1 dimensions (QED 2 ), within the Hamiltonian formulation of lattice field theory. Quasidistributions are spatial correlation functions of boosted states, which approach the relevant light-cone distributions in the luminal limit. Using tensor networks, we prepare the first excited state in the strongly coupled regime and boost it to close to the light-cone on lattices of up to 400 lattice sites. We compute both quasiparton distribution functions and, for the first time, quasi-GPDs, and study their convergence for increasingly boosted states. In addition, we perform analytic calculations of GPDs in the two-particle Fock-space approximation and in the Reggeized limit, providing qualitative benchmarks for the tensor network results. Our analysis establishes computational benchmarks for accessing partonic observables in low-dimensional gauge theories, offering a starting point for future extensions to higher dimensions, non-Abelian theories, and quantum simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

A Framework for Compressing Unstructured Scientific Data via Serialization

We present a general framework for compressing unstructured scientific data with known local connectivity. A common application is simulation data defined on arbitrary finite element meshes. The framework employs a greedy topology preserving reordering of original nodes which allows for seamless integration into existing data processing pipelines. This reordering process depends solely on mesh connectivity and can be performed offline for optimal efficiency. However, the algorithm’s greedy nature also supports on-the-fly implementation. The proposed method is compatible with any compression algorithm that leverages spatial correlations within the data. The effectiveness of this approach is demonstrated on a large-scale real dataset using several compression methods, including MGARD, SZ, and ZFP.

Reshniak, Viktor [ORNL] (ORCID:0000000315454462)↗

DeepGraphONet: A Deep Graph Operator Network to Learn and Zero-Shot Transfer the Dynamic Response of Networked Systems

This article develops a deep graph operator network (DeepGraphONet) framework that learns to approximate the dynamics of a complex system (e.g., the power grid or traffic) with an underlying subgraph structure. Here, we build our DeepGraphONet by fusing the ability of graph neural networks to exploit spatially correlated graph information and deep operator networks to approximate the solution operator of dynamical systems. The resulting DeepGraphONet can then predict the dynamics within a given short/medium-term time horizon by observing a finite history of the graph state information. Furthermore, we design our DeepGraphONet to be resolution independent. That is, we do not require the finite history to be collected at the exact/same resolution. In addition, to disseminate the results from a trained DeepGraphONet, we design a zero-shot learning strategy that enables using it on a different subgraph. Finally, empirical results on the transient stability prediction problem of power grids and traffic flow forecasting problem of a vehicular system illustrate the effectiveness of the proposed DeepGraphONet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role of Water on the Interfacial Adhesion in Si Solar Modules

Delamination of solar module interfaces often occurs in field-tested solar modules after decades of service due to environmental stressors such as humidity. As water diffuses into the module, failure mechanisms like corrosion and delamination are significantly affected. In the presence of water, the interfaces between EVA and the cell, glass, and backsheet all experience losses of adhesion exposing the module to accelerated degradation. Understanding the relation between interfacial adhesion and water content inside PV modules can help mitigate detrimental power losses. Water content measurements via short wave infrared reflectometry combined with 180 degrees peel tests were used to study and quantify the effect of water ingress and egress on adhesion. Changes in adhesion strength for different module interfaces are quantified, correlating spatial distribution of water content to adhesion for damp heat and dry heat exposed samples. After 1000 hours of damp heat exposure, decreases in adhesion strength of approximately 1 N/mm were noted for all interfaces.

adhesion↗

First application of dynamic infrared imaging in boron neutron capture therapy for cutaneous malignant melanoma

Purpose: The purpose of this study is to assess the potential of dynamic infrared imaging (DIRI) as a functional, noninvasive technique for evaluating the skin acute toxicity and tumor control within the framework of the Argentine boron neutron capture therapy (BNCT) program for cutaneous malignant melanoma. Methods: Two patients enrolled in the Argentine phase I/II BNCT clinical trial for cutaneous malignant melanoma were studied with DIRI. An uncooled infrared camera, providing a video output signal, was employed to register the temperature evolution of the normal skin and tumor regions in patients subjected to a mild local cooling (cold stimulus). In order to study the spatial correlation between dose and acute skin reactions, three-dimensional representations of the superficial dose delivered to skin were constructed and cameralike projections of the dose distribution were coregistered with visible and infrared images. Results: The main erythematous reaction was observed clinically between the second and fifth week post-BNCT. Concurrently, with its clinical onset, a reactive increase above the basal skin temperature was observed with DIRI in the third week post-BNCT within regions that received therapeutic doses. Melanoma nodules appeared as highly localized hyperthermic regions. 2 min after stimulus, these regions reached a temperature plateau and increased in size. Temperature differences with respect to normal skin up to 10 deg. C were observed in the larger nodules. Conclusions: Preliminary results suggest that DIRI, enhanced by the application of cold stimuli, may provide useful functional information associated with the metabolism and vasculature of tumors and inflammatory processes related to radiation-induced changes in the skin as well. These capabilities are aimed at complementing the clinical observations and standard imaging techniques, such as CT and Doppler ultrasound.

61 RADIATION PROTECTION AND DOSIMETRY↗

A semiempirical linear model of indirect, flat-panel x-ray detectors

Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r{sup 2} of signal mean to kV: 0.91, 0.93, 0.86, and 0.99 for 0.1-mm Sn, 0.2-mm Cu, 1.5-mm Al, and 0.05-mm Ag, respectively; r{sup 2} of signal variance to kV: 0.99 for all four filters). The comparison of the signal and noise (mean, variance, and NPS) between the simulated and measured air scan images suggested that this model was reasonable in predicting accurate signal statistics of air scan images using absolute percent error. Overall, the model was found to be accurate in estimating signal statistics and spatial correlation between the detector elements of the images acquired with indirect, flat-panel x-ray detectors. Conclusions: The semiempirical linear model of the indirect, flat-panel x-ray detectors was described and validated with images of air scans. The model was found to be a useful tool in understanding the signal and noise transfer within indirect, flat-panel x-ray detector systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-91: Biomechanical Deformable Image Registration of Longitudinal Lung CT Images

Purpose: Spatial correlation of lung tissue across longitudinal images, as the patient responds to treatment, is a critical step in adaptive radiotherapy. The goal of this work is to expand a biomechanical model-based deformable registration algorithm (Morfeus) to achieve accurate registration in the presence of significant anatomical changes. Methods: Four lung cancer patients previously treated with conventionally fractionated radiotherapy that exhibited notable tumor shrinkage during treatment were retrospectively evaluated. Exhale breathhold CT scans were obtained at treatment planning (PCT) and following three weeks (W3CT) of treatment. For each patient, the PCT was registered to the W3CT using Morfeus, a biomechanical model-based deformable registration algorithm, consisting of boundary conditions on the lungs and incorporating a sliding interface between the lung and chest wall. To model the complex response of the lung, an extension to Morfeus has been developed: (i) The vessel tree was segmented by thresholding a vesselness image based on the Hessian matrix’s eigenvalues and the centerline was extracted; (ii) A 3D shape context method was used to find correspondences between the trees of the two images; (ii) Correspondences were used as additional boundary conditions (Morfeus+vBC). An expert independently identified corresponding landmarks well distributed in the lung to compute Target Registration Errors (TRE). Results: The TRE within 15mm of the tumor boundaries (on average 11 landmarks) is: 6.1±1.8, 4.6±1.1 and 3.8±2.3 mm after rigid registration, Morfeus and Morfeus+vBC, respectively. The TRE in the rest of the lung (on average 13 landmarks) is: 6.4±3.9, 4.7±2.2 and 3.6±1.9 mm, which is on the order of the 2mm isotropic dose grid vector (3.5mm). Conclusion: The addition of boundary conditions on the vessels improved the accuracy in modeling the response of the lung and tumor over the course of radiotherapy. Minimizing and modeling these geometrical uncertainties will enable future plan adaptation strategies. This work was funded in part by NIH 2P01CA059827-16.

60 APPLIED LIFE SCIENCES↗

SU-E-J-124: 18F-FDG PET Imaging to Improve RT Treatment Outcome for Locally Advanced Lung Cancer

Purpose: To investigate spatial correlation between high uptake regions of pre- and 10-days-post therapy{sup 1} {sup 8}F-FDG PET in recurrent lung cancer and to evaluate the feasibility of dose escalation boosting only regions with high FDG uptake identified on baseline PET. Methods: Nineteen patients with stages II– IV inoperable lung cancer were selected. Volumes of interest (VOI) on pre-therapy FDG-PET were defined using an isocontour at ≥50% of SUVmax. VOI of pre- and post-therapy PET images were correlated for the extent of overlap. A highly optimized IMRT plan to 60 Gy prescribed to PTV defined on the planning CT was designed using clinical dose constraints for the organs at risk. A boost of 18 Gy was prescribed to the VOI defined on baseline PET. A composite plan of the total 78 Gy was compared with the base 60 Gy plan. Increases in dose to the lungs, spinal cord and heart were evaluated. IMRT boost plan was compared with proton RT and SBRT boost plans. Results: Overlap fraction of baseline PET VOI with the VOI on 10 days-post therapy PET was 0.8 (95% CI: 0.7 – 0.9). Using baseline VOI as a boosting volume, dose could be escalated to 78 Gy for 15 patients without compromising the dose constraints. For 4 patients, the dose limiting factors were V20Gy and Dmean for the total lung, and Dmax for the spinal cord. An increase of the dose to OARs correlated significantly with the relative size of the boost volume. Conclusion: VOI defined on baseline 18F-FDG PET by the SUVmax-≥50% isocontour may be a biological target volume for escalated radiation dose. Dose escalation to this volume may provide improved tumor control without breaching predefined dose constraints for OARs. The best treatment outcome may be achieved with proton RT for large targets and with SBRT for small targets.

60 APPLIED LIFE SCIENCES↗

SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Field Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing reliable bio-markers for treatment response evaluation. The Department of Radiation Oncology at Henry Ford Health System has research agreement with Varian Medical System and Philips Health Care.

60 APPLIED LIFE SCIENCES↗

SU-E-T-476: Improving KCl:Eu2+ Dosimeter Sensitivity: The Role of Oxygen

Purpose: Recent research has shown that KCl:Eu2+ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. The purpose of this work is to determine if increased signal could be realized in KCl:Eu2+ by incorporating oxygen in the material fabrication process. Methods: The prototype KCl:Eu2+ dosimeters have a physical makeup similar to thermoluminescent dosimeter chips. The photostimulation light source consists of either a He-Ne laser or a UV enhanced Xe arc lamp with wavelength selection provided by a motorized monochromator. X-ray diffraction is used to determine the phase composition of the dosimeters. Photoluminescence (PL) and photostimulated luminescence (PSL) emission spectra are obtained using a Nanolog Spectrofluoremeter. Results: Europium activator is completely incorporated into the KCl parent-matrix without the formation of a noticeable secondary phase. Regardless of synthesis atmosphere, air or pure nitrogen, PSL amplitude shows a maximum at 1.0 mol % Eu. Depending on europium concentration, dosimeters fabricated in air exhibit stronger PSL by a factor of 2 to 4 compared to those made in N2. There is no change in PSL stimulation spectrum while noticeable shifts in both PL and PSL emission spectra are observed for air versus nitrogen. Almost all charge-storage centers are spatially correlated, suggesting oxygen’s stabilization role in the PSL process. KCl:Eu2+ made in oxygen-rich air is capable of measuring a dose-to-water as low as 0.01 cGy from a 6MV photon beam with a signal-to-noise ratio greater than 6. Conclusions: Synthesis in a reduction atmosphere, for example, nitrogen, was thought to be mandatory in order to retain europium activator’s divalent status to be PSL active. Fortunately, divalent europium can be well preserved in an oxygen-rich atmosphere. More importantly, oxygen can enhance PSL by a factor of 2 to 4. HL is the founder of DoseImaging, LLC that is exclusively dedicated to commercializing this technology.

36 MATERIALS SCIENCE↗

WE-FG-202-09: Voxel-Level Analysis of Adverse Treatment Response in Pediatric Patients Treated for Ependymoma with Passive Scattering Proton Therapy

Purpose: We identified patients treated for ependymoma with passive scattering proton therapy who subsequently developed treatment-related imaging changes on MRI. We sought to determine if there is any spatial correlation between imaged response, dose, and LET. Methods: A group of 14 patients treated for ependymoma were identified as having post-treatment MR imaging changes observable as T2-FLAIR hyperintensity with or without enhancement on T1 post-contrast sequences. MR images were registered with treatment planning CT images and regions of treatment-related change contoured by a practicing radiation oncologist. The contoured regions were identified as response with voxels represented as 1 while voxels within the brain outside of the response region were represented as 0. An in-house Monte Carlo system was used to recalculate treatment plans to obtain dose and LET information. Voxels were binned according to LET values in 0.3 keV µm{sup −1} bins. Dose and corresponding response value (0 or 1) for each voxel for a given LET bin were then plotted and fit with the Lyman-Kutcher-Burman dose response model to determine TD{sub 50} and m parameters for each LET value. Response parameters from all patients were then collated, and linear fits of the data were performed. Results: The response parameters TD50 and m both show trends with LET. Outliers were observed due to low numbers of response voxels in some cases. TD{sub 50} values decreased with LET while m increased with LET. The former result would indicate that for higher LET values, the dose is more effective, which is consistent with relative biological effectiveness (RBE) models for proton therapy. Conclusion: A novel method of voxel-level analysis of image biomarker-based adverse patient treatment response in proton therapy according to dose and LET has been presented. Fitted TD{sub 50} values show a decreasing trend with LET supporting the typical models of proton RBE. Funding provided by NIH Program Project Grant 2U19CA021239-35.

60 APPLIED LIFE SCIENCES↗