Impact of Electric Industry Structure on High Wind Penetration Potential
This paper attempts to evaluate which balancing area (BA) characteristics best accommodate wind energy.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This paper attempts to evaluate which balancing area (BA) characteristics best accommodate wind energy.
Information security continues to evolve in response to disruptive changes with a persistent focus on information-centric controls and a healthy debate about balancing endpoint and network protection, with a goal of improved enterprise/business risk management. Economic uncertainty, intensively collaborative styles of work, virtualization, increased outsourcing and ongoing compliance pressures require careful consideration and adaptation. This paper proposes a Cyberspace Security Econometrics System (CSES) that provides a measure (i.e., a quantitative indication) of reliability, performance and/or safety of a system that accounts for the criticality of each requirement as a function of one or more stakeholders interests in that requirement. For a given stakeholder, CSES reflects the variance that may exist among the stakes she/he attaches to meeting each requirement. This paper introduces the basis, objectives and capabilities for the CSES including inputs/outputs as well as the structural and mathematical underpinnings.
Part Two expands upon Part One in an attempt to translate the methodology for ground system personnel. The goal is to build upon the methodology presented in Part One by showing examples and details on how to implement the methodology. Section 1: Ground Systems Overview; Section 2: Secure Software Development; Section 3: Defense in Depth for Ground Systems; Section 4: What Now?
A Sentry Remote Monitoring System (Sentry-RMS) is a stand-alone security system that provides detection, assessment, and communication of priority alarms as an additional means of thwarting internal and external threats to sites that maintain radiological material. The SEntry-RMS CommUnications and REsponse (Sentry-SECURE) platform is an optional feature of the Sentry-RMS that relays priority alarm information to the identified response stakeholders. Sentry-SECURE is hosted in a cloud environment that abstracts the data owner’s and data consumer’s platforms to allow for greater information sharing. This promotes situational awareness amongst authorized users and enables future innovation among modern response platforms. When securely architecting a cloud solution such as this, the use of design paradigms can be an effective tool to increase the accuracy and reliability of cyber- and information-security-related decisions made throughout the development process. This approach also supports the categorization of design considerations into three levels: industry concepts, project approaches, and data protections for digital processes. Industry concepts consist of the notional underpinnings that guide or motivate a security process, system, or design but often lack any tangible attributes. Project approaches represent decisions made during the design and development process to prioritize a solution, method, or practice above another that may provide a comparable functional output but lacks a desired security benefit. Data protections for digital processes represent the selection, integration, and implementation of specific controls for a given asset. This paper will explore specific examples of how Sentry-SECURE has been designed to account for considerations at each of these three levels, while balancing the operational intent of the platform with the security enhancements necessary to maintain data integrity, availability, and confidentiality.
A mini split cooling system will be used to maintain temperature requirements in a mobile secure transport system. While the split cooling system was designed to be used in static residential or commercial applications, it was selected for this transportation application due to a unique set of security requirements. However, the system’s ability maintain reliability and survive prolonged long-term shock and vibration is a significant concern. The mitigation strategy is to select vibration isolation mounts and perform lifetime shock and vibration testing to demonstrate survivability. The goal of this study is to generate a finite element model of the system and perform modal analysis to inform selection of vibration mounts to minimize the amount of vibrational energy transferred to the split cooling system. The scope of this report is limited to study of the condensing unit only, and geometric variation of the assembly will not be allowed.
Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.
The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.
Extensive deployment of interoperable distributed energy resources (DER) is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid‐support functions, which can drastically influence power quality, voltage, and bulk system frequency. Here, the authors investigate the impact to the cyber‐physical power system in scenarios where communications and operations of DER are controlled by an adversary. The findings show that each grid‐support function exposes the power system to distinct types and magnitudes of risk. The physical impact from cyber actions was analysed in cases of DER providing distribution system voltage regulation and transmission system support. Finally, recommendations are presented for minimising the risk using engineered parameter limits and segmenting the control network to minimise common‐mode vulnerabilities.
In this work, dynamic analysis techniques help programmers find the root cause of bugs in large-scale parallel applications.
Transport of high-consequence shipments requires a resilient and robust systems of systems to guarantee cargo arrival. Furthermore, rising adoption of technologies such as connected and automated vehicles (CAVs), intelligent infrastructure, and vehicle-to-everything (V2X) communication presents unique challenges for securing transportation systems. Within these Intelligent Transportation Systems (ITS), several additional vulnerabilities exist that create pathways for adversarial attacks and cargo interception. For example, connectivity provides cyber pathways directly into vehicle systems and infrastructure for malicious actors. Furthermore, advanced vehicle automation exposes additional vehicle control necessary for shipment interception otherwise unavailable to adversaries. Within this paper, we will discuss the specific threats introduced by ITS-enabled technologies currently deployed and in development. These include those mentioned related to connectivity and automation, but will be expanded into grid, infrastructure, and vehicle specific threats. In addition, we will discuss how to potentially mitigate these emerging challenges as well as how to safeguard transportation systems from next generation attacks.
No abstract prepared.
Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.
“Source ID Mix” has emerged as a new type of highly deceiving attack which can alter the source information of synchrophasor data measured by multiple phasor measurement units, thereby paralyzing many wide-area measurement systems applications. To address such sophisticated cyber attacks, we have exploited the spatio-temporal characteristics of synchrophasor data for authenticating measurements’ source information. Specifically, the source authentication is performed when the measurements are subjected to three types of spoofing attacks. Some practical difficulties in applying the proposed method on real-time authentication caused by insufficient measurement data have also been solved. Experimental results with real synchrophasor measurements have validated the effectiveness of the proposed method in detecting such complicated data spoofing and improving power systems’ cyber security.
Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.
Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.
Climate change influences on the major pillars of food security. Each of the four elements of food security (availability,access,utilization,andstability) is vulnerable to changes in climate. For example,reductions in production related to regional drought influence food availability at multiple scales. Changes in price influences the ability of certain populations to purchase food (access). Utilization maybe affected when production zones shift, reducing the availability of preferred or culturally appropriate types of food within a region. Stability of the food supply may be highly uncertain given an increased incidence of extreme climatic events and their influence on production patterns.
The National Aeronautics and Space Administration (NASA) has tens of thousands of networked computer systems and applications. Software Security vulnerabilities present risks such as lost or corrupted data, information theft, and unavailability of critical systems. These risks represent potentially enormous costs to NASA. The NASA Code Q research initiative 'Reducing Software Security Risk (RSSR) Trough an Integrated Approach' offers formal verification of information technology (IT), through the creation of a Software Security Assessment Instrument (SSAI), to address software security risks.
Methods and systems for secured control of circuit breakers in an electric power substation against undesired direct operation. Consequences of a malicious action are prevented or mitigated using a validation approach that either blocks the command or ensures a negligible effect on system operation. An example method, suitable for implementation in a monitoring device in an electric power substation, includes receiving a command to open or close a circuit breaker. In response, one or more state parameters for the electric power network that comprises the substation are then predicted, the predicted state parameters reflecting an operating state for the network under the assumption that the received command is executed. The method further comprises comparing the predicted one or more state parameters to corresponding operational limits. Execution of the command is then blocked, in response to determining that one or more of the predicted state parameters violate the corresponding operational limits.