Search NASA⌕ Search

SEARCH · Search NASA

Results for “temporal resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Interstellar Mapping And Acceleration Probe High Energy (IMAP-Hi) Neutral Atom Imager

The IMAP-Hi Energetic Neutral Atom (ENA) Imager on NASA’s Interstellar Mapping and Acceleration Probe (IMAP) mission (McComas et al. 2018a, 2025) is designed to measure ENAs from the global interaction between the heliosphere and the local interstellar medium (LISM). These ENAs are initially plasma ions of solar wind origin that are neutralized by charge exchange with the cold neutral atoms of LISM that freely flow through the heliosphere-LISM interaction region. IMAP-Hi consists of two identical single-pixel sensors, each covering the ENA spectral range from 0.44 keV to 15.6 keV over nine contiguous energy passbands and having an approximately conical field-of-view (FOV) of 4.1o full width at half maximum (FWHM). The Hi-45 sensor points 45o relative to the spacecraft spin axis from the antisunward direction; each spacecraft spin, it measures ENA intensity over a circular swath with half-cone angle 45o centered on the ecliptic plane. The Hi-90 sensor points 90o relative to the spin axis; each spacecraft spin, it measures ENA intensity over a great circle in the sky, sampling both the north and south ecliptic poles. As the IMAP spin vector is re-pointed daily toward the Sun, the ecliptic longitude of the swaths moves daily by ∼1o such that a full sky map is acquired by Hi-90 every six months and a complete low latitude (−45o to +45o) map is acquired by Hi-45 annually. The IMAP-Hi sensor design has direct heritage from the IBEX-Hi imager on the Interstellar Boundary Explorer (IBEX) mission, with substantial improvements in energy range, energy resolution, angular resolution, signal-to-noise ratio, and, for ecliptic latitudes within ±45o, temporal resolution and exposure time. The global ENA maps acquired by IMAP-Hi partially overlap in energy and viewing with the ENA maps acquired by the IMAP-Lo and IMAP-Ultra ENA imagers, which we combine to answer fundamental questions about the structure and dynamics of the interaction of the heliosphere and the LISM.

79 ASTRONOMY AND ASTROPHYSICS↗

A simple electron time-of-flight spectrometer for ultrafast vacuum ultraviolet photoelectron spectroscopy of liquid solutions

We present a simple electron time of flight spectrometer for time resolved photoelectron spectroscopy of liquid samples using a vacuum ultraviolet (VUV) source produced by high-harmonic generation. The field free spectrometer coupled with the time-preserving monochromator for the VUV at the Artemis facility of the Rutherford Appleton Laboratory achieves an energy resolution of 0.65 eV at 40 eV with a sub 100 fs temporal resolution. A key feature of the design is a differentially pumped drift tube allowing a microliquid jet to be aligned and started at ambient atmosphere while preserving a pressure of 10⁻¹ mbar at the micro channel plate detector. The pumping requirements for photoelectron (PE) spectroscopy in vacuum are presented, while the instrument performance is demonstrated with PE spectra of salt solutions in water. The capability of the instrument for time resolved measurements is demonstrated by observing the ultrafast (50 fs) vibrational excitation of water leading to temporary proton transfer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Laser Megajoule’s x-ray streak camera

A prototype of a picosecond x-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to provide plasma-diagnostic support for the Laser Megajoule. We report on the measured performance of this streak camera, which almost fulfills the requirements: 50-μm spatial resolution over a 15-mm field in the photocathode plane, 17-ps temporal resolution in a 2-ns timebase, a detection threshold lower than 625 nJ/cm{sup 2} in the 0.05–15 keV spectral range, and a dynamic range greater than 100.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 2D velocity estimation method for large transient events in plasmas

Dynamics of fast transient events are challenging to be analyzed with high time resolution. Such events can occur in fusion plasmas such as the filaments during edge-localized modes (ELMs). Here, we present a robust method—the spatial displacement estimation—for estimating the displacements of structures with fast dynamics from high spatial and time resolution imaging diagnostics [e.g., gas-puff imaging (GPI)] with sampling time temporal resolution. First, a background suppression method is shown, which suppresses the slowly time-evolving and spatially non-uniform background in the signal. In the second step, a two-dimensional polynomial trend subtraction method is presented to tackle the remaining polynomial order trend in the signal. After performing these pre-processing steps, the spatial displacement of the propagating structure is estimated from the two-dimensional spatial cross-correlation coefficient function calculated between consecutive frames. The method is tested for its robustness and accuracy by simulated Gaussian events and spatially displaced random noise. An example application of the method is presented on propagating ELM filaments measured by the GPI system on the National Spherical Torus Experiment spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sparkling extreme-ultraviolet bright dots observed with Hi-C

Observing the Sun at high time and spatial scales is a step toward understanding the finest and fundamental scales of heating events in the solar corona. The high-resolution coronal (Hi-C) instrument has provided the highest spatial and temporal resolution images of the solar corona in the EUV wavelength range to date. Hi-C observed an active region on 2012 July 11 that exhibits several interesting features in the EUV line at 193 Å. One of them is the existence of short, small brightenings 'sparkling' at the edge of the active region; we call these EUV bright dots (EBDs). Individual EBDs have a characteristic duration of 25 s with a characteristic length of 680 km. These brightenings are not fully resolved by the SDO/AIA instrument at the same wavelength; however, they can be identified with respect to the Hi-C location of the EBDs. In addition, EBDs are seen in other chromospheric/coronal channels of SDO/AIA, which suggests a temperature between 0.5 and 1.5 MK. Based on their frequency in the Hi-C time series, we define four different categories of EBDs: single peak, double peak, long duration, and bursty. Based on a potential field extrapolation from an SDO/HMI magnetogram, the EBDs appear at the footpoints of large-scale, trans-equatorial coronal loops. The Hi-C observations provide the first evidence of small-scale EUV heating events at the base of these coronal loops, which have a free magnetic energy of the order of 10{sup 26} erg.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray

Purpose: Carbon nanotube (CNT) based field emission x-ray source technology has recently been investigated for diagnostic imaging applications because of its attractive characteristics including electronic programmability, fast switching, distributed source, and multiplexing. The purpose of this article is to demonstrate the potential of this technology for high-resolution prospective-gated cardiac micro-CT imaging. Methods: A dynamic cone-beam micro-CT scanner was constructed using a rotating gantry, a stationary mouse bed, a flat-panel detector, and a sealed CNT based microfocus x-ray source. The compact single-beam CNT x-ray source was operated at 50 KVp and 2 mA anode current with 100 {mu}mx100 {mu}m effective focal spot size. Using an intravenously administered iodinated blood-pool contrast agent, prospective cardiac and respiratory-gated micro-CT images of beating mouse hearts were obtained from ten anesthetized free-breathing mice in their natural position. Four-dimensional cardiac images were also obtained by gating the image acquisition to different phases in the cardiac cycle. Results: High-resolution CT images of beating mouse hearts were obtained at 15 ms temporal resolution and 6.2 lp/mm spatial resolution at 10% of system MTF. The images were reconstructed at 76 {mu}m isotropic voxel size. The data acquisition time for two cardiac phases was 44{+-}9 min. The CT values observed within the ventricles and the ventricle wall were 455{+-}49 and 120{+-}48 HU, respectively. The entrance dose for the acquisition of a single phase of the cardiac cycle was 0.10 Gy. Conclusions: A high-resolution dynamic micro-CT scanner was developed from a compact CNT microfocus x-ray source and its feasibility for prospective-gated cardiac micro-CT imaging of free-breathing mice under their natural position was demonstrated.

60 APPLIED LIFE SCIENCES↗

Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system

Purpose: To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. Methods: The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm{sup 3} spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identified around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. Results: For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. Conclusions: The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.

60 APPLIED LIFE SCIENCES↗

Absolute calibration method for fast-streaked, fiber optic light collection, spectroscopy systems.

This report outlines a convenient method to calibrate fast (<1ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such a system is used to collect spectral data on plasmas generated in the A-K gap of electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA). On RITS, light is collected through a small diameter (200 micron) optical fiber and recorded on a fast streak camera at the output of 1 meter Czerny-Turner monochromator (F/7 optics). To calibrate such a system, it is necessary to efficiently couple light from a spectral lamp into a 200 micron diameter fiber, split it into its spectral components, with 10 Angstroms or less resolution, and record it on a streak camera with 1ns or less temporal resolution.

43 PARTICLE ACCELERATORS↗

Measurement and modeling of moist processes

The keynote talk summarized five years of work simulating observed mesoscale convective systems with the RAMS (Regional Atmospheric Modeling System) model. Excellent results are obtained when simulating squall line or other convective systems that are strongly forced by fronts or other lifting mechanisms. Less highly forced systems are difficult to model. The next topic in this colloquium was measurement of water vapor and other constituents of the hydrologic cycle. Impressive accuracy was shown measuring water vapor with both the airborne DIAL (Differential Absorption Lidar) system and the the ground-based Raman Lidar. NMC's plans for initializing land water hydrology in mesoscale models was presented before water vapor measurement concepts for GCIP were discussed. The subject of using satellite data to provide mesoscale moisture and wind analyses was next. Recent activities in modeling of moist processes in mesoscale systems was reported on. These modeling activities at the Canadian Atmospheric Environment Service (AES) used a hydrostatic, variable-resolution grid model. Next the spatial resolution effects of moisture budgets was discussed; in particular, the effects of temporal resolution on heat and moisture budgets for cumulus parameterization. The conclusion of this colloquium was on modeling scale interaction processes.

Cotton, William↗

Version 2 Goddard Satellite-Based Surface Turbulent Fluxes (GSSTF2)

Information on the turbulent fluxes of momentum, moisture, and heat at the air-sea interface is essential in improving model simulations of climate variations and in climate studies. We have derived a 13.5-year (July 1987-December 2000) dataset of daily surface turbulent fluxes over global oceans from the Special Sensor Mcrowave/Imager (SSM/I) radiance measurements. This dataset, version 2 Goddard Satellite-based Surface Turbulent Fluxes (GSSTF2), has a spatial resolution of 1 degree x 1 degree latitude-longitude and a temporal resolution of 1 day. Turbulent fluxes are derived from the SSM/I surface winds and surface air humidity, as well as the 2-m air and sea surface temperatures (SST) of the NCEP/NCAR reanalysis, using a bulk aerodynamic algorithm based on the surface layer similarity theory.

Chou, Shu-Hsien↗

Intercomparison of Latent Heat Fluxes Over Global Oceans

Turbulent fluxes of momentum, moisture, and heat at the air-sea interface are essential for climate studies. Version 2 Goddard Satellite-based Surface Turbulent Fluxes (GSSTF2) has been derived from the Special Sensor Microwave/Imager (SSM/I) radiance measurements. This dataset, covering the period July 1987-December 2000 over global oceans, has a spatial resolution of 1 deg x 1 deg lat-long and a temporal resolution of 1 day. Turbulent fluxes are derived from the SSM/I surface winds and surface air humidity, as well as the 2-m air and sea surface temperatures (SST) of the NCEP/NCAR reanalysis, using a bulk aerodynamic algorithm based on the surface layer similarity theory. The GSSTF2 bulk flux model, and retrieved daily wind stress, latent heat flux, wind speed, and surface air humidity validate well with ship observations of ten field experiments over the tropical and midlatitude oceans during 1991-99. The global distributions of 1988-2000 annual- and seasonal-mean turbulent fluxes show reasonable patterns related to the atmospheric general circulation and seasonal variations. Latent heat fluxes and related input parameters over global oceans during 1992-93 have been compared among GSSTF1 (version 1), GSSTF2, HOAPS (Hamburg Ocean Atmosphere Parameters and Fluxes from Satellite Data), NCEP/NCAR reanalysis, and one based on COADS (Comprehensive Ocean-Atmosphere Data Set). Our analyses suggest that the GSSTF2 latent heat flux, surface air humidity, surface wind, and SST are quite realistic compared to the other four flux datasets examined. However, significant differences are found among these five flux datasets. The GSSTF2, available at http://daac.gsfc.nasa.gov/CAMPAIGN_DOCS/hydrology/hd_gsstf2.O.html, is useful for climate studies.

Chou, Shu-Hsien↗

The Advanced Pair Telescope (APT) Mission Concept

We present a mission concept for the Advanced Pair Telescope (APT), a high-energy gamma-ray instrument with an order of magnitude improvement in sensitivity, 6 sr field of view, and angular resolution a factor of 3-10 times that of GLAST. With its very wide instantaneous field-of-view and large effective area, this instrument would be capable of detecting GRBs at very large redshifts, would enable a very high resolution study of SNRs and PWN, and could provide hour-scale temporal resolution of transients from many AGN and galactic sources. The APT instrument will consist of a Xe time-projection-chamber tracker that bridges the energy regime between Compton scattering and pair production and will provide an unprecedented improvement in angular resolution; a thick scintillating-fiber trackerlcalorimeter that will provide sensitivity and energy resolution to higher energies and will possess a factor of 10 improvement in geometric factor over GLAST; and an anticoincidence detector using scintillator-tiles to reject charged particles. After the anticipated 10-years of GLAST operation , the APT instrument would provide continued coverage of the critial high-energy gamma-ray band (between 30 MeV to 100 GeV), providing an essential component of broad-band multiwavelength studies of the high-energy universe.

Hunter, Stanley↗

Future of Big Earth Data Analytics

The state of the art of Big Earth Data Analytics can be expected to evolve rapidly in the coming years. The forces driving evolution come from both growth in the data and advancement in the field of data analytics. In the data area, advances in sensor instrumentation and platform miniaturization are increasing both data resolution and coverage, resulting in enormous growth in data Volume. Increases in temporal resolution in particular also generate demands for higher data Velocity. At the same time, the proliferation of instruments and the platforms on which they reside is increasing the Variety of datasets. The Variety increase in turn leads to questions about the Veracity of the data. In the algorithm area, powerful machine learning methods are coming to the fore, particularly Deep Neural Networks. These are powerful at detecting interesting features in the data, integrating many different measurements (i.e., data fusion), and classification problems. However, they are still challenging when seeking explanations of how natural or socio-economic phenomena work using Earth Observations. Thus, classical analysis techniques will remain relevant when the emphasis is on forming or testing explanations, as well as to support interactive data exploration.

Lynnes, Christopher↗

A Hybrid Electrostatic Retarding Potential Analyzer for the Measurement of Plasmas at Extremely High Energy Resolution

Many space plasmas (especially electrons generated in planetary ionospheres) exhibit fine-detailed structures that are challenging to fully resolve with the energy resolution of typical space plasma analyzers (10% → 20%). While analyzers with higher resolution have flown, generally this comes at the expense of sensitivity and temporal resolution. We present a new technique for measuring plasmas with extremely high energy resolution through the combination of a top-hat Electrostatic Analyzer (ESA) followed by an internally mounted Retarding Potential Analyzer (RPA). When high resolutions are not required, the RPA is grounded, and the instrument may operate as a typical general-purpose plasma analyzer using its ESA alone. We also describe how such an instrument may use its RPA to remotely vary the geometric factor (sensitivity) of a top hat analyzer, as was performed on the New Horizons Solar Wind at Pluto and MAVEN SupraThermal and Thermal Ion Composition instruments. Finally, we present results from laboratory testing of our prototype, showing that this technique may be used to construct an instrument with 1.6% energy resolution, constant over all energies and angles.

Collinson, Glyn A.↗

Imaging the behavior of molecules in biological systems: Breaking the 3D speed barrier with 3D multi-resolution microscopy

Here, the overwhelming effort in the development of new microscopy methods has been focused on increasing the spatial and temporal resolution in all three dimensions to enable the measurement of the molecular scale phenomena at the heart of biological processes. However, there exists a significant speed barrier to existing 3D imaging methods, which is associated with the overhead required to image large volumes. This overhead can be overcome to provide nearly unlimited temporal precision by simply focusing on a single molecule or particle via real-time 3D single-particle tracking and the newly developed 3D Multi-resolution Microscopy (3D-MM). Here, we investigate the optical and mechanical limits of real-time 3D single-particle tracking in the context of other methods. In particular, we investigate the use of an optical cantilever for position sensitive detection, finding that this method yields system magnifications of over 3000×. We also investigate the ideal PID control parameters and their effect on the power spectrum of simulated trajectories. Taken together, these data suggest that the speed limit in real-time 3D single particle-tracking is a result of slow piezoelectric stage response as opposed to optical sensitivity or PID control.

3D Multi-resolution microscopy↗

Single-shot optical recording with sub-picosecond resolution spans record nanosecond lengths

With the advent of electronics, oscilloscopes and photodiodes are now routinely capable of measuring events well below nanosecond resolution. However, these electronic instruments do not currently measure events below 10 ps resolution. From Walden’s observation that there is an engineering tradeoff between electronic bit depth and temporal resolution in analog-to-digital converters, this technique is projected to have extremely poor fidelity if it is extended to record single events with picosecond resolution. While this constraint may be circumvented with extensive signal averaging or other multiple measurements approaches, rare events and nonrepetitive events cannot be observed with this technique. Techniques capable of measuring information in a single shot are often required. There is a general lack of available technologies that are easily scalable to long records with sub-picosecond resolution, and are simultaneously versatile in wavelength of operation. Since it is difficult to scale electronic methods to shorter resolutions, we instead aim to scale optical methods to longer records. Demonstrated optical recording methods that have achieved 1 ps resolution and long recording lengths rely on either time scaling to slow down the temporal information or, like Wien, perform time-to-space mapping so that fast events may be captured with a conventional camera.

47 OTHER INSTRUMENTATION↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRACER UAS CopterSonde Profiles

This dataset comes from a rotary-wing, weather-sensing uncrewed aerial system called the CopterSonde. Temperature, pressure, humidity, wind speed, and direction are gathered during vertical profiles. The vertical resolution is 5 m up to 609 m above ground level and the temporal resolution is on average 30 minutes.

54 ENVIRONMENTAL SCIENCES↗