Search NASA⌕ Search

SEARCH · Search NASA

Results for “throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Management of metadata and automation for mail-in measurements with the APS 11-BM high throughput, high-resolution synchrotron powder diffractometer.

A high-resolution and high-throughput synchrotron powder diffractometer has been automated for use with samples that are mailed in by Advanced Photon Source users. Implementation of a relational database with web interfaces for both outside users and beamline staff, which is integrated into the facility-wide proposal and safety system, allows all aspects of beamline management to be integrated. This system permits users to request kits for mounting samples, to provide sample safety information, to obtain their collected data and to provide usage information upon project completion in a quick and simple manner. Beamline staff use a separate interface to note receipt of samples, schedule and collect diffraction data, post-process and quality-check data, and dispose of samples. The design of the software and database are discussed in detail.

43 PARTICLE ACCELERATORS↗

BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1

The general-purpose powder diffractometer beamline (BL2-1) at the Stanford Synchrotron Radiation Lightsource (SSRL) is described. The evolution of design and performance of BL2-1 are presented, in addition to current operating specifications, applications and measurement capabilities. Recent developments involve a robotic sample changer enabling high-throughput X-ray diffraction measurements, applicable to mail-in and remote operations. In situ and operando capabilities to measure samples with different form factors ( e.g. capillary, flat plate or thin film, and transmission) and under variable experimental conditions are discussed. Several example datasets and accompanying Rietveld refinements are presented.

43 PARTICLE ACCELERATORS↗

A high-throughput energy-dispersive tender X-ray spectrometer for shot-to-shot sulfur measurements

An X-ray emission spectrometer that can detect the sulfur K α emission lines with large throughput and a high energy resolution is presented. The instrument is based on a large d -spacing perfect Bragg analyzer that diffracts the sulfur K α emission at close to backscattering angles. This facilitates the application of efficient concepts routinely employed in hard X-ray spectrometers towards the tender X-ray regime. The instrument described in this work is based on an energy-dispersive von Hamos geometry that is well suited for photon-in photon-out spectroscopy at X-ray free-electron laser and synchrotron sources. Comparison of its performance with previously used instrumentation is presented through measurements using sulfur-containing species performed at the LCLS. It is shown that the overall signal intensity is increased by a factor of ∼15. Implementation of this approach in the design of a tender X-ray spectroscopy endstation for LCLS-II is also discussed.

36 MATERIALS SCIENCE↗

Sagittal collimating diaboloid: a new grazing-incidence mirror surface for higher-throughput resonant inelastic X-ray scattering spectrometers

A major challenge in soft X-ray spectroscopy is the efficient collection of the emitted X-rays by grazing-incidence mirrors. In this energy range, grazing-incidence mirrors are widely used as optics for the collection of light. The small angle of incidence necessarily limits the collection solid angle of soft X-ray spectrometers. We present a new mirror surface, a sagittal collimating diaboloid, that can both collect and focus light from a point source in an aberration-free manner. The usefulness of this optic in increasing throughput is demonstrated with a realistic example design of a moderate-sized (3 m) medium-resolution resonant inelastic X-ray scattering spectrometer.

36 MATERIALS SCIENCE↗

High-Throughput Computing on High-Performance Platforms: A Case Study

The computing systems used by LHC experiments has historically consisted of the federation of hundreds to thousands of distributed resources, ranging from small to mid-size resource. In spite of the impressive scale of the existing distributed computing solutions, the federation of small to mid-size resources will be insufficient to meet projected future demands. This paper is a case study of how the ATLAS experiment has embraced Titan -- a DOE leadership facility in conjunction with traditional distributed high- throughput computing to reach sustained production scales of approximately 52M core-hours a years. The three main contributions of this paper are: (i) a critical evaluation of design and operational considerations to support the sustained, scalable and production usage of Titan; (ii) a preliminary characterization of a next generation executor for PanDA to support new workloads and advanced execution modes; and (iii) early lessons for how current and future experimental and observational systems can be integrated with production supercomputers and other platforms in a general and extensible manner.

Oleynik, D↗

ISOBAR Preconditioner for Effective and High-throughput Lossless Data Compression

Efficient handling of large volumes of data is a necessity for exascale scientific applications and database systems. To address the growing imbalance between the amount of available storage and the amount of data being produced by high speed (FLOPS) processors on the system, data must be compressed to reduce the total amount of data placed on the file systems. General-purpose loss less compression frameworks, such as zlib and bzlib2, are commonly used on datasets requiring loss less compression. Quite often, however, many scientific data sets compress poorly, referred to as hard-to-compress datasets, due to the negative impact of highly entropic content represented within the data. An important problem in better loss less data compression is to identify the hard-to-compress information and subsequently optimize the compression techniques at the byte-level. To address this challenge, we introduce the In-Situ Orthogonal Byte Aggregate Reduction Compression (ISOBAR-compress) methodology as a preconditioner of loss less compression to identify and optimize the compression efficiency and throughput of hard-to-compress datasets.

Computer Science↗

A Custom High-Throughput Optical Mapping Instrument for Accelerated Stress Testing of PV Module Materials

The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.

14 SOLAR ENERGY↗

Entanglement Throughput Measurements and Capacity Estimates for Aerial-Inground Fiber

The throughput of entangled qubit pairs per second (eqps) is a basic performance metric of quantum networks that provide the entanglement distribution capability. Over fiber connections, it is measured using specialized instruments, including photonic entanglement sources and single-photon detectors. Extensive theory has been developed to estimate the capacity of a generic quantum channel, which in turn is applied to estimate the maximum achievable eqps over a fiber connection. However, there is a gap in relating these two performance metrics, in part due to their disparate nature, namely, mathematical formulae of the channel capacity and specialized instrumentation for eqps measurements. We describe eqps measurements collected over testbed connections composed of aerial and inground fiber of lengths up to 45 km. We estimate the normalized capacity using the transmissivity parameter derived from single photon detector measurements. These estimates are then converted to capacity bounds on the connection's eqps using the source eqps rate derived from co-located detector measurements. The results indicate a consistency between eqps measurements and their capacity estimates, and provide insights into relating the parameters of analytic capacity estimates to physical measurements.

Rao, Nageswara [ORNL] (ORCID:0000000234085941)↗

Dissecting Tensor Cores via Microbenchmarks: Latency, Throughput and Numeric Behaviors

Tensor Cores have been an important unit to accelerate Fused Matrix Multiplication Accumulation (MMA) in all NVIDIA GPUs since Volta Architecture. To program Tensor Cores, users have to use either legacy wmma APIs or current mma APIs. Legacy wmma APIs are more easy-to-use but can only exploit limited features and power of Tensor Cores. Specifically, wmma APIs support fewer operand shapes and can not leverage the new sparse matrix multiplication feature of the newest Ampere Tensor Cores. However, the performance of current programming interface has not been well explored. Furthermore, the computation numeric behaviors of low-precision floating points (TF32, BF16, and FP16) supported by the newest Ampere Tensor Cores are also mysterious. In this paper, we explore the throughput and latency of current programming APIs. Further, we intuitively study the numeric behaviors of Tensor Cores MMA and profile the intermediate operations including multiplication, addition of inner product, and accumulation. All codes used in this work can be found in https://github.com/sunlex0717/DissectingTensorCores.

97 MATHEMATICS AND COMPUTING↗

PacBio high‐throughput multi‐locus sequencing reveals high genetic diversity in mushroom‐forming fungi

Abstract Multi‐locus sequence data are widely used in fungal systematic and taxonomic studies to delimit species and infer evolutionary relationships. We developed and assessed the efficacy of a multi‐locus pooled sequencing method using PacBio long‐read high‐throughput sequencing. Samples included fresh and dried voucher specimens, cultures and archival DNA extracts of Agaricomycetes with an emphasis on the order Cantharellales. Of the 283 specimens sequenced, 93.6% successfully amplified at one or more loci with a mean of 3.3 loci amplified. Our method recovered multiple sequence variants representing alleles of rDNA loci and single copy protein‐coding genesrpb1,rpb2 andtef1. Within‐sample genetic variation differed by locus and taxonomic group, with the greatest genetic divergence observed among sequence variants ofrpb2 andtef1 from corticioid Cantharellales. Our method is a cost‐effective approach for generating accurate multi‐locus sequence data coupled with recovery of alleles from polymorphic samples and multi‐organism specimens. These results have important implications for understanding intra‐individual genomic variation among genetic loci commonly used in species delimitation of fungi.

Biochemistry & Molecular Biology↗

High-throughput serum proteomics for the identification of protein biomarkers of mortality in older men

The biological perturbations associated with incident mortality are not well elucidated, and there are limited biomarkers for the prediction of mortality. In this work we used a novel high throughput proteomics approach to identify serum peptides and proteins associated with 5 year mortality in community dwelling men age >65 years who participated in a longitudinal observational study of musculoskeletal aging (Osteoporotic Fractures in Men: MrOS). In a discovery phase, serum specimens collected at baseline in 2473 men were analyzed using liquid chromatography-ion mobility-mass spectrometry, and incident mortality in the subsequent 5 years was ascertained by tri-annual questionnaire. Rigorous statistical methods were utilized to identify 56 peptides (31 proteins) that were associated with 5-year mortality. In an independent replication phase, selected reaction monitoring was used to examine 21 of those peptides in baseline serum from 750 additional men; 81% of those peptides remained significantly associated with mortality. Mortality-associated proteins included a variety involved in inflammation or complement activation; several have been previously linked to mortality (e.g. C reactive protein, alpha 1-antichymotrypsin) and others are not previously known to be associated with mortality. Other novel proteins of interest included pregnancy-associated plasma protein, VE cadherin, leucine-rich α-2 glycoprotein 1, vinculin, vitronectin, mast/stem cell growth factor receptor and Saa4. A panel of peptides improved the predictive value of a commonly used clinical predictor of mortality. Overall, these results suggest that complex inflammatory pathways, and proteins in other pathways, are linked to 5-year mortality risk. This work may serve to identify novel biomarkers for near term mortality.

60 APPLIED LIFE SCIENCES↗

Estimating Protistan Diversity Using High‐Throughput Sequencing

Abstract Sequencing hypervariable regions from the 18S rRNA gene is commonly employed to characterize protistan biodiversity, yet there are concerns that short reads do not provide the same taxonomic resolution as full‐length sequences. A total of 7,432 full‐length sequences were used to perform an in silico analysis of how sequences of various lengths and target regions impact downstream ecological interpretations. Sequences that were longer than 400 nucleotides and included the V4 hypervariable region generated results similar to those derived from full‐length 18S rRNA gene sequences. Present high‐throughput sequencing capabilities are approaching protistan diversity estimation comparable to whole gene sequences.

Hu, Sarah K.↗

Using In Vitro High‐Throughput Screening Data for Predicting Benzo[k]Fluoranthene Human Health Hazards

Today there are more than 80,000 chemicals in commerce and the environment. The potential human health risks are unknown for the vast majority of these chemicals as they lack human health risk assessments, toxicity reference values, and risk screening values. We aim to use computational toxicology and quantitative high‐throughput screening (qHTS) technologies to fill these data gaps, and begin to prioritize these chemicals for additional assessment. In this pilot, we demonstrate how we were able to identify that benzo[k]fluoranthene may induce DNA damage and steatosis using qHTS data and two separate adverse outcome pathways (AOPs). We also demonstrate how bootstrap natural spline‐based meta‐regression can be used to integrate data across multiple assay replicates to generate a concentration–response curve. We used this analysis to calculate an in vitro point of departure of 0.751 μM and risk‐specific in vitro concentrations of 0.29 μM and 0.28 μM for 1:1,000 and 1:10,000 risk, respectively, for DNA damage. Based on the available evidence, and considering that only a single HSD17B4 assay is available, we have low overall confidence in the steatosis hazard identification. This case study suggests that coupling qHTS assays with AOPs and ontologies will facilitate hazard identification. Combining this with quantitative evidence integration methods, such as bootstrap meta‐regression, may allow risk assessors to identify points of departure and risk‐specific internal/ in vitro concentrations. These results are sufficient to prioritize the chemicals; however, in the longer term we will need to estimate external doses for risk screening purposes, such as through margin of exposure methods.

Burgoon, Lyle D.↗

High-sensitivity high-throughput chip based biosensor array for multiplexed detection of heavy metals

Heavy metal ions released into the environment from industrial processes lead to various health hazards. We propose an on-chip label-free detection approach that allows high-sensitivity and high-throughput detection of heavy metals. The sensing device consists of 2-dimensional photonic crystal microcavities that are combined by multimode interferometer to form a sensor array. Here, we experimentally demonstrate the detection of cadmium-chelate conjugate with concentration as low as 5 parts-per-billion (ppb).

42 ENGINEERING↗

WE-E-BRE-07: High-Throughput Mapping of Proton Biologic Effect

Purpose: To systematically relate the relative biological effectives (RBE) of proton therapy to beam linear energy transfer (LET) and dose. Methods: Using a custom irradiation apparatus previously characterized by our group, H460 NSCLCs were irradiated using a clinical 80MeV spot scanning proton beam. Utilizing this system allowed for high-throughput clonogenic assays performed in 96-well tissue culture plates as opposed to the traditional 6-well technique. Each column in the 96-well plate received a set LET-dose combination. By altering the total number of dose repaintings, numerous dose-LET configurations were examined to effectively generate surviving fraction (SF) data over the entire Bragg peak. The clonogenic assay was performed post-irradiation using an INCell Analyzer for colony quantification. SF data were fit to the linear-quadratic model for analysis. Results: Irradiation with increasing LETs resulted in decreased cell survival largely independent of dose. A significant correlation between LET and SF was identified by two-way ANOVA and the extra sum-of-squares F test. This trend was obscured at the lower LET values in the plateau region of the Bragg peak; however, it was clear for LET values at and beyond the Bragg peak. Data fits revealed the SF at a dose of 2Gy (SF2) to be 0.48 for the lowest tested LET (1.55keV/um), 0.47 at the end of the plateau region (4.74keV/um) and 0.33 for protons at the Bragg peak (10.35keV/um). Beyond the Bragg peak we measured SF2s of 0.16 for 15.01keV/um, 0.02 for 16.79keV/um, and 0.004 for 18.06keV/um. Conclusion: We have shown that our methodology enables high-content automated screening for proton irradiations over a range of LETs. The observed decrease in cellular SF in high LET regions confirms an increased RBE of the radiation and suggests further evaluation of proton RBE values is necessary to optimize clinical outcomes. Rosalie B. Hite Graduate Fellowship in Cancer Research, NIH Program Project Grant P01CA021239.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-12: Spatial Mapping of Scanned Proton Biologic Effect Using the High-Throughput Technique, Continued

Purpose: To investigate the biologic effects of scanned protons by evenly sampling dose-averaged LET (LETd) values. Methods: Our previous high-throughput clonogenic study demonstrated a distinct relationship between RBE and LETd. However, our initial experimental design resulted in over-sampling the low LETd values in the plateau region of the Bragg curve while under-sampling in the region proximal to the Bragg peak as well as the high LETd values in the distal edge of the Bragg curve. To further examine the relationship between RBE and LETd, we refined the experimental design to more evenly sample proton LETd values from 1 to 20 keV/µm by optimizing the thicknesses of the irradiation jig steps. We used the clonogenic survival as the biological endpoint for the H460 lung cancer cell line cultured in 96-well plates (12 columns by 8 rows). In the irradiation, the 8 wells in each column received a uniform dose-LETd pair. The dose-LETd pairs of the 12 different columns were sampled along the Bragg curve of 81.4 MeV scanned protons. Five peak dose levels from 1.5 Gy to 7.5 Gy were delivered with an increment of 1.5 Gy in the preliminary test. Two 96-well plates were irradiated simultaneously to decrease the statistical uncertainties. Results: In the proximal region, for LETd = 5 keV/µm and 8 keV/µm, we did not observe any distinct differential biologic effects between the survival curves. At the Bragg peak (LETd = 9.5 keV/µm) and in the distal edge, irradiation with increasing LET values resulted in decreasing cell survival. Conclusion: The survival curves from the new experimental design support our previous findings that below 10 keV/µm, the LET effect in cell kill is obscured, but above 10 keV/µm, the biologic effects increase with LETd. Funding Support: U19 CA021239-35 and R21 CA187484-01.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated discovery of metallic glasses through iteration of machine learning and high-throughput experiments

With more than a hundred elements in the periodic table, a large number of potential new materials exist to address the technological and societal challenges we face today; however, without some guidance, searching through this vast combinatorial space is frustratingly slow and expensive, especially for materials strongly influenced by processing. We train a machine learning (ML) model on previously reported observations, parameters from physiochemical theories, and make it synthesis method–dependent to guide high-throughput (HiTp) experiments to find a new system of metallic glasses in the Co-V-Zr ternary. Experimental observations are in good agreement with the predictions of the model, but there are quantitative discrepancies in the precise compositions predicted. We use these discrepancies to retrain the ML model. The refined model has significantly improved accuracy not only for the Co-V-Zr system but also across all other available validation data. We then use the refined model to guide the discovery of metallic glasses in two additional previously unreported ternaries. Although our approach of iterative use of ML and HiTp experiments has guided us to rapid discovery of three new glass-forming systems, it has also provided us with a quantitatively accurate, synthesis method–sensitive predictor for metallic glasses that improves performance with use and thus promises to greatly accelerate discovery of many new metallic glasses. We believe that this discovery paradigm is applicable to a wider range of materials and should prove equally powerful for other materials and properties that are synthesis path–dependent and that current physiochemical theories find challenging to predict.

36 MATERIALS SCIENCE↗