Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Experimental and theoretical evidence for hydrogen doping in polymer solution-processed indium gallium oxide

The field-effect electron mobility of aqueous solution-processed indium gallium oxide (IGO) thin-film transistors (TFTs) is significantly enhanced by polyvinyl alcohol (PVA) addition to the precursor solution, a >70-fold increase to 7.9 cm 2 /Vs. To understand the origin of this remarkable phenomenon, microstructure, electronic structure, and charge transport of IGO:PVA film are investigated by a battery of experimental and theoretical techniques, including In K-edge and Ga K-edge extended X-ray absorption fine structure (EXAFS); resonant soft X-ray scattering (R-SoXS); ultraviolet photoelectron spectroscopy (UPS); Fourier transform-infrared (FT-IR) spectroscopy; time-of-flight secondary-ion mass spectrometry (ToF-SIMS); composition-/processing-dependent TFT properties; high-resolution solid-state 1 H, 71 Ga, and 115 In NMR spectroscopy; and discrete Fourier transform (DFT) analysis with ab initio molecular dynamics (MD) liquid-quench simulations. The 71 Ga{ 1 H} rotational-echo double-resonance (REDOR) NMR and other data indicate that PVA achieves optimal H doping with a Ga···H distance of ~3.4 Å and conversion from six- to four-coordinate Ga, which together suppress deep trap defect localization. This reduces metal-oxide polyhedral distortion, thereby increasing the electron mobility. Finally, hydroxyl polymer doping thus offers a pathway for efficient H doping in green solvent-processed metal oxide films and the promise of high-performance, ultra-stable metal oxide semiconductor electronics with simple binary compositions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fixed Source Sensitivity Calculations for Inertial Confinement Fusion Applications

A numerical code library was developed for the radiation transport code MCNP6.3 to calculate generalized response sensitivity coefficients for fixed source neutron transport problems with applications to inertial confinement fusion (ICF) experiments. The new MCNP6.3 dependency is used to generate a novel time convolution response that represents a neutron time-of-flight (nToF) signal. The traditional suite of macroscopic cross-section sensitivities and constrained fixed source probability distribution sensitivities are available for both the standard and the new response tallies in this library. However, novel sensitivity coefficients for the constrained hyperparameters of analytic fixed source probability distributions are emphasized in this work for their connection to ICF neutron transport models. Particularly, advanced Monte Carlo methods are developed for calculating the sensitivity of a nToF signal to perturbations in an ICF plasma’s ion temperature and burn history as well as perturbations in the target liner mass density and the shape parameters of the nToF detector’s impulse response function. Together, these capabilities form an advanced suite of computational tools that can be used to analyze and extract information from any ICF experimental platform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single photon simultaneous K-shell ionization/excitation in C 6 H 6 : experiment and theory

Single photon simultaneous core ionization/core excitation (K -2 V) of the Benzene molecule has been observed experimentally, using synchrotron radiation, by electron coincidence spectroscopy with a magnetic bottle time-of-flight electron spectrometer and reveals a rich spectrum. DFT and Post–Hartree–Fock calculations provide detailed assignments of K -2 V states. The specific Auger decay of these states has also been determined experimentally with a new technique to improve the energy resolution.

Optics↗

Quantitative investigation of surface structure and interatomic potential with impact-collision ion scattering spectroscopy

Helium ion beam interactions with materials have important implications for magnetic confinement fusion, material modification, and helium ion microscopy. These interactions depend on the precise physics of how helium ions channel into the materials, which can vary greatly based on the local crystalline orientation. Here, we performed a dedicated experiment to investigate helium ion channeling in a well-characterized tungsten single crystal. Time-of-flight impact-collision ion scattering spectroscopy was used to obtain multi-angle maps of the backscattering intensity for 3 keV He + → W(111). We found that the backscattering intensity profile arising from helium ion channeling could be well described by a shadow cone analysis. This analysis revealed that subsurface W atoms as deep as the ninth monolayer contributed to the backscattering intensity profile. Binary collision approximation simulations were performed with MARLOWE to model the experimental maps with sufficient accuracy to allow for quantitative comparisons using reliability factors. These quantitative comparisons were applied to investigate how the W lattice structure and He–W interatomic potential affect the multi-angle maps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin fluctuations in the 112-type iron-based superconductor Ca 0.82 La 0.18 Fe 0.96 Ni 0.04 As 2

Abstract We report time-of-flight inelastic neutron scattering (INS) investigations on the spin fluctuation spectrum in the 112-type iron-based superconductor (FeSC) Ca 0.82 La 0.18 Fe 0.96 Ni 0.04 As 2 (CaLa-112). In comparison to the 122-type FeSCs with a centrosymmetric tetragonal lattice structure (space group I 4 / m m m ) at room temperature and an in-plane stripe-type antiferromagnetic (AF) order at low temperature, the 112 system has a noncentrosymmetric structure (space group P 2 1 ) with additional zigzag arsenic chains between Ca/La layers and a magnetic ground state with similar wavevector Q A F but different orientations of ordered moments in the parent compounds. Our INS study clearly reveals that the in-plane dispersions and the bandwidth of spin excitations in the superconducting CaLa-112 closely resemble to those in 122 systems. While the total fluctuating moments ⟨ m 2 ⟩ ≈ 4.6 ± 0.2 μ B 2 /Fe are larger than 122 system, the dynamic correlation lengths are similar ( ξ ≈ 10 Å). These results suggest that superconductivity in iron arsenides may have a common magnetic origin under similar magnetic exchange couplings with a dual nature from local moments and itinerant electrons, despite their different magnetic patterns and lattice symmetries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impurity gas detection for SNF canisters using probabilistic deep learning and acoustic sensing *

Abstract Monitoring impurity gases in spent nuclear fuel (SNF) canisters is a novel structural health monitoring approach for SNF in dry storage. The SNF canisters are sealed containers that do not facilitate visual access to the inside. Acoustic sensing can be deployed by taking advantage of the pathways unobstructed by internal hardware. Although the ultrasonic time-of-flight measurement can provide valuable information, it is limited in its ability to discern the concentration of only one impurity gas. As such, deep learning algorithms, particularly convolutional neural networks (CNNs), offer a promising solution. In this study, CNN-based probabilistic deep learning models were implemented to detect and quantify multiple impurity gases in helium. An experimental platform was established to simulate canister conditions, and ultrasonic test data were collected. The presence of argon and air in helium at concentrations ranging from 0% to 1.2% at increments of 0.05% was considered. The multi-layer perceptron, decision tree, and logistic regression classifiers achieved high accuracies when distinguishing pure helium from helium with impurities. CNN with dropout layers and CNN using maximum likelihood estimation showed a similar performance, indicating their ability to capture uncertainties. The ensemble CNN model exhibited improved predictions and the ability to balance individual gas concentration by integrating 1D- and 2D-CNN models. These findings contribute probabilistic deep learning solutions for impurity gas detection and analysis within SNF canisters, thus ensuring safe storage and management of SNFs.

47 OTHER INSTRUMENTATION↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The inertial confinement fusion experimental platform and diagnostics for studies of nuclear reactions relevant to nuclear astrophysics

High energy density plasmas generated in laser-driven inertial confinement fusion implosions provide unparalleled laboratory conditions for studying stellar-relevant nuclear reactions: plasma environment; hot and dense; uniquely high achievable neutron flux. These experiments have the potential to address long-standing questions about plasma effects on nuclear reactions hitherto experimentally inaccessible, including nuclear rates with thermally distributed reactants, plasma screening, and reactions involving nuclei in excited states. The National Ignition Facility (NIF) and OMEGA lasers are two primary facilities for executing experiments of this type. Existing and future nuclear diagnostics, along with supporting diagnostics to characterize the platform, enable exploitation of these plasmas for such nuclear astrophysics-relevant experiments. Here, this review describes the nuclear diagnostic capabilities currently available for these types of experiments at the NIF and OMEGA, including neutron time-of-flight spectrometers, charged-particle detectors, gamma detectors and radiochemistry diagnostics, and briefly summarizes other available diagnostic capabilities used for platform characterization. Enabling tools not yet available are also identified, including a rapid radioactive sample retrieval system, a low-energy neutron spectrometer and a high-efficiency gamma spectrometer.

National Ignition Facility↗

Understanding atom probe’s analytical performance for iron oxides using correlation histograms and ab initio calculations

Abstract Field evaporation from ionic or covalently bonded materials often leads to the emission of molecular ions. The metastability of these molecular ions, particularly under the influence of the intense electrostatic field (10 10 Vm −1 ), makes them prone to dissociation with or without an exchange of energy amongst them. These processes can affect the analytical performance of atom probe tomography (APT). For instance, neutral molecules formed through dissociation may not be detected at all or with a time of flight no longer related to their mass, causing their loss from the analysis. Here, we evaluated the changes in the measured composition of FeO, Fe 2 O 3 and Fe 3 O 4 across a wide range of analysis conditions. Possible dissociation reactions are predicted by density-functional theory calculations considering the spin states of the molecules. The energetically favoured reactions are traced on to the multi-hit ion correlation histograms, to confirm their existence within experiments, using an automated Python-based routine. The detected reactions are carefully analyzed to reflect upon the influence of these neutrals from dissociation reactions on the performance of APT for analysing iron oxides.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Experimental validation of an integrated modelling approach to neutron emission studies at JET

An integrated modelling methodology for the calculation of realistic plasma neutron sources for the JET tokamak has been developed. The computational chain comprises TRANSP plasma transport and DRESS neutron spectrum calculations, and their coupling to the MCNP neutron transport code, bridging plasma physics and neutronics. Here, we apply the developed methodology to the analysis of neutron emission properties of deuterium and helium plasmas at JET, and validate individual modelling steps against neutron diagnostic measurements. Two types of JET discharges are modelled—baseline-like and three-ion radio-frequency scenarios—due to their diversity in plasma heating, characteristics of the induced fast ion population, and the imprint of these on neutron emission properties. The neutron emission modelling results are quantitatively compared to the total neutron yield from fission chambers, neutron emissivity profiles from the neutron camera, neutron spectra from the time-of-flight spectrometer, and neutron activation measurements. The agreement between measured and calculated quantities is found to be satisfactory for all four diagnostic systems within the estimated experimental and computational uncertainties. Additionally, the effect of neutrons not originating from the dominating D(D, n) 3 He reactions is studied through modelling of triton burnup DT neutrons, and, in mixed D- 3 He plasmas, neutrons produced in the 9 Be(D, nγ) 10 B reaction on impurities. It is found that these reactions can contribute up to several percent to the total neutron yield and dominate the neutron activation of samples. Finally, the effect of MeV-range fast ions on the neutron activation of 115 In and 27 Al samples is measured and computationally validated.

integrated modelling↗

The impact of helium on plasma-driven hydrogen permeation and implications for direct internal recycling in the fusion fuel cycle

Abstract Metal foil pumps (MFPs) are the leading technology for direct internal recycling (DIR) of hydrogen isotopes from the plasma exhaust in future fusion plants. MFPs rely on the concept of superpermeation, where superthermal H atoms directly absorb into the metal foil, rapidly diffuse, and desorb downstream. To date, studies of superpermeation have predominantly employed either pure hydrogen or in some cases trace levels of impurities. The plasma exhaust is expected to contain just ∼1% helium, but in DIR the source gas would be enriched in helium as hydrogen isotopes are extracted. In this work, we explore the impact of helium on hydrogen superpermeation at low temperature (75 °C–200 °C) using Pd-based foils. To first order, the flux scaled linearly with the hydrogen mole fraction. Stable permeation was observed until the helium fraction reached ∼80%, where the flux began to decline slowly with time. In addition, short term (1–5 min) exposure to pure helium plasma significantly attenuated subsequent hydrogen plasma permeation, and the degree was more dramatic at elevated temperature. This attenuation was correlated with He retention in the foils, which was detected by time-of-flight secondary ion mass spectrometry at low levels (<0.1 at. %) and limited to the near surface (<10 nm). Similar trends were observed among all alloys (Pd, PdAg, PdCu), and the foils were restored to full performance with an Ar + sputter clean. The potential for helium plasma exposure to impact MFP performance under these conditions has not been previously reported, and these findings have significant implications to the design and implementation of practical DIR systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping the frontiers of the nuclear mass surface

Nuclear masses play a central role in nuclear astrophysics, significantly impacting the origin of the elements and observables used to constrain ultradense matter. A variety of techniques are available to meet this need, varying in their emphasis on precision and reach from stability. Here I briefly summarize the status of and near-future for the time-of-flight magnetic-rigidity (TOF-Bρ) mass measurement technique, emphasizing the complementary and interconnectedness with higher-precision mass measurement methods. This includes of recent examples from TOF-Bρ mass measurements that map the evolution of nuclear structure across the nuclear landscape and significantly impact the results and interpretation of astrophysical model calculations. I also forecast expected expansion in the known nuclear mass surface from future measurement at the Facility for Rare Isotope Beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Calorimetric Energy Reconstruction of Beam Events with ARAPUCA Light Detector in ProtoDUNE-SP

ProtoDUNE Single Phase at CERN is the large scale prototype for the far detector of the future DUNE experiment. ProtoDUNE is in stable operation since Oct. 2018 at the CERN Neutrino Platform. Test beam data in the energy range of sub-GeV to a few GeV were collected in fall 2018 providing a set of key measurements. Particles (electrons, protons, pions, muons and kaons) are identified combining information from a set of beam-line detectors (Time of Flight, Cherenkov) and TPC reconstruction. Three different technologies are implemented in the protoDUNE photon detector system (PDS). Results from the ARAPUCA response, one of the PDS components, are presented providing first calorimetric energy measurements and particle ID of beam events from LAr scintillation light signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Eos: conceptual design for a demonstrator of hybrid optical detector technology

Eos is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With a fiducial mass of four tons, Eos is designed to operate in a high-precision regime, with sufficient size to utilize time-of-flight information for full event reconstruction, flexibility to demonstrate a range of cutting edge technologies, and simplicity of design to facilitate potential future deployment at alternative sites. Results from Eos can inform the design of future neutrino detectors for both fundamental physics and nonproliferation applications. This paper describes the conceptual design and potential applications of the Eos

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exhaled breath biomarkers of influenza infection and influenza vaccination

Respiratory viral infections are considered a major public health threat, and breath metabolomics can provide new ways to detect and understand how specific viruses affect the human pulmonary system. In this pilot study, we characterized the metabolic composition of human breath for an early diagnosis and differentiation of influenza viral infection, as well as other types of upper respiratory viral infections. We first studied the non-specific effects of planned seasonal influenza vaccines on breath metabolites in healthy subjects after receiving the immunization. We then investigated changes in breath content from hospitalized patients with flu-like symptoms and confirmed upper respiratory viral infection. The exhaled breath was sampled using a custom-made breath condenser, and exhaled breath condensate (EBC) samples were analysed using liquid chromatography coupled to quadruplole-time-of-flight mass spectrometer (LC-qTOF). All metabolomic data was analysed using both targeted and untargeted approaches to detect specific known biomarkers from inflammatory and oxidative stress biomarkers, as well as new molecules associated with specific infections. We were able to find clear differences between breath samples collected before and after flu vaccine administration, together with potential biomarkers that are related to inflammatory processes and oxidative stress. Moreover, we were also able to discriminate samples from patients with flu-related symptoms that were diagnosed with confirmatory respiratory viral panels (RVPs). RVP positive and negative differences were identified, as well as differences between specific viruses defined. These results provide very promising information for the further study of the effect of influenza A and other viruses in human systems by using a simple and non-invasive specimen like breath.

60 APPLIED LIFE SCIENCES↗

CFM-ID 4.0 – a web server for accurate MS-based metabolite identification

The CFM-ID 4.0 web server (https://cfmid.wishartlab.com) is an online tool for predicting, annotating and interpreting tandem mass (MS/MS) spectra of small molecules. It is specifically designed to assist researchers pursuing studies in metabolomics, exposomics and analytical chemistry. More specifically, CFM-ID 4.0 supports the: 1) prediction of electrospray ionization quadrupole time-of-flight tandem mass spectra (ESI-QTOF-MS/MS) for small molecules over multiple collision energies (10 eV, 20 eV, and 40 eV); 2) annotation of ESI-QTOF-MS/MS spectra given the structure of the compound; and 3) identification of a small molecule that generated a given ESI-QTOF-MS/MS spectrum at one or more collision energies. The CFM-ID 4.0 web server makes use of a substantially improved MS fragmentation algorithm, a much larger database of experimental and in silico predicted MS/MS spectra and improved scoring methods to offer more accurate MS/MS spectral prediction and MS/MS-based compound identification. Compared to earlier versions of CFM-ID, this new version has an MS/MS spectral prediction performance that is ~22% better and a compound identification accuracy that is ~35% better on a standard (CASMI 2016) testing dataset. CFM-ID 4.0 also features a neutral loss function that allows users to identify similar or substituent compounds where no match can be found using CFM-ID’s regular MS/MS-to-compound identification utility. Finally, the CFM-ID 4.0 web server now offers a much more refined user interface that is easier to use, supports molecular formula identification (from MS/MS data), provides more interactively viewable data (including proposed fragment ion structures) and displays MS mirror plots for comparing predicted with observed MS/MS spectra. These improvements should make CFM-ID 4.0 much more useful to the community and should make small molecule identification much easier, faster, and more accurate.

59 BASIC BIOLOGICAL SCIENCES↗