Search NASA⌕ Search

SEARCH · Search NASA

Results for “time segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

On-the-fly segmentation approaches for x-ray diffraction datasets for metallic glasses

Investment in brighter sources and larger detectors has resulted in an explosive rise in the data collected at synchrotron facilities. Currently, human experts extract scientific information from these data, but they cannot keep pace with the rate of data collection. Here, we present three on-the-fly approaches—attribute extraction, nearest-neighbor distance, and cluster analysis—to quickly segment x-ray diffraction (XRD) data into groups with similar XRD profiles. An expert can then analyze representative spectra from each group in detail with much reduced time, but without loss of scientific insights. As a result, on-the-fly segmentation would, therefore, result in accelerated scientific productivity.

36 MATERIALS SCIENCE↗

Creation of high-quality long-distance entanglement with flexible resources

We present a quantum repeater protocol that generates the elementary segments of entangled photons through the communication of qubus in coherent states. The input photons at the repeater stations can be in arbitrary states to save the local state preparation time for the operations. The flexibility of the scheme accelerates the generation of the elementary segments (close to the exact Bell states) to a high rate for practical quantum communications. The entanglement connection to long distances is simplified and sped up, possibly realizing an entangled pair of high quality within the time in the order of that for classical communication between two far-away locations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searching for Neutrino Tridents in the NOvA Near Detector

This dissertation presents a search for neutrino trident production in the NOvA near detector through the coherent ``dimuon" channel: $\nu_\mu +\hspace{1pt}\text{X} \rightarrow \nu_\mu + \mu^- + \mu^+ +\hspace{1pt}\text{X}$. Trident production is a rare, purely electroweak process with sensitivity to physics beyond the Standard Model. The theoretical background, motivation for studying the process, and previous experimental measurements are reviewed. The analysis uses data collected by the NOvA near detector (ND) from Fermilab's Neutrinos at the Main Injector (NuMI) beam between November 2014 and February 2024, corresponding to an exposure of $25.5\times 10^{20}$ protons on target. The ND is a segmented tracking calorimeter located 800~m from the beam target, receiving neutrinos with a mean energy of 2~GeV. A multi-pass background reduction strategy is implemented, including the development of a novel dimuon-specific tracking technique. Trident candidates are identified using a boost ed decision tree classifier trained on simulated signal and background events. Limited background Monte Carlo statistics necessitate the use of functional fits to sideband data, which are extrapolated to estimate backgrounds in the signal region. The unblinded data contain 9 trident-like events, with an estimated background of 5.66 $\pm$ 5.15 events. This yields a best fit estimate of 3.34 tridents compared to the Standard Model prediction of 4.66. A profiled Feldman-Cousins method is used to determine a 90\% confidence interval of [0,9.1] on the number of signal events, corresponding to an upper limit of 1.95$\times$ the Standard Model prediction. This result represents the lowest energy search for trident events to date, and the first experimental contribution to the process in 27 years.

Bowles, Reed Scott [Indiana U.]↗

Simulator study of a pictorial display for general aviation instrument flight

A simulation study of a computer drawn pictorial display involved a flight task that included an en route segment, terminal area maneuvering, a final approach, a missed approach, and a hold. The pictorial display consists of the drawing of boxes which either move along the desired path or are fixed at designated way points. Two boxes may be shown at all times, one related to the active way point and the other related to the standby way point. Ground tracks and vertical profiles of the flights, time histories of the final approach, and comments were obtained from time pilots. The results demonstrate the accuracy and consistency with which the segments of the flight are executed. The pilots found that the display is easy to learn and to use; that it provides good situation awareness, and that it could improve the safety of flight. The small size of the display, the lack of numerical information on pitch, roll, and heading angles, and the lack of definition of the boundaries of the conventional glide slope and localizer areas were criticized.

Adams, J. J.↗

Hestia SW-IFL Onroad Fossil Fuel Carbon Dioxide (FFCO2) product: Road segment-level annual FFCO2 emissions across Arizona (2017-2022), version 1.1

The SW-IFL onroad fossil fuel carbon dioxide (FFCO2) emissions data product represents CO2 emissions from the combustion of fossil fuels by motor vehicles (e.g., passenger cars, trucks, buses, motorcycles) traveling on designated roadways. The emissions are represented geographically on each road segment within the state of Arizona spanning the 2017 to 2022 time period. This data product was developed as part of the Southwest Urban Corridor Integrated Field Laboratory (SW-IFL) project, which aims to provide new knowledge and tools that address urban environmental issues by integrating high-resolution observations, modeling, and civic engagement. The emissions data are provided in CSV (input data, ONR_FFCO2_AZ_county.csv) and GeoPackage form (output polyline objects - about 786,000 road segments, XXXX_AZ_v1.1.gpkg) designated by road class (interstates, arterials, collectors, local). The metadata file (Metadata_SW-IFL_Onroad_annualFFCO2_v1.1.docx) provides details about attributes and data formats. The GeoPackage emissions data are provided separately for local roads and nonlocal roads (interstates, arterials, collectors). The method file (Methods_SW-IFL_Onroad_annualFFCO2_v1.1.docx) describes the data processing flow and data sources. Update on 2024-04-17: Updates were made to both the input emission data file (.csv) and output segment-level emission file (.gpkg). There was an update in county-level emission input data (ONR_FFCO2_AZ_county.csv) and the entire road segments were reprocessed to reflect this update.Update on 2024-04-29: Update was made to one output segment-level emission file (Nonlocal_AZ_v1.0.gpkg). There was an error in the AADT values and the data were reprocessed to reflect this update.Update on 2024-10-22: Temporal coverage was extended to include 2022. VMT values were recalculated using new AADT data and the entire road segments were reprocessed to reflect these updates.

54 ENVIRONMENTAL SCIENCES↗

Effects of modeling errors on trajectory predictions in air traffic control automation

Air traffic control automation synthesizes aircraft trajectories for the generation of advisories. Trajectory computation employs models of aircraft performances and weather conditions. In contrast, actual trajectories are flown in real aircraft under actual conditions. Since synthetic trajectories are used in landing scheduling and conflict probing, it is very important to understand the differences between computed trajectories and actual trajectories. This paper examines the effects of aircraft modeling errors on the accuracy of trajectory predictions in air traffic control automation. Three-dimensional point-mass aircraft equations of motion are assumed to be able to generate actual aircraft flight paths. Modeling errors are described as uncertain parameters or uncertain input functions. Pilot or autopilot feedback actions are expressed as equality constraints to satisfy control objectives. A typical trajectory is defined by a series of flight segments with different control objectives for each flight segment and conditions that define segment transitions. A constrained linearization approach is used to analyze trajectory differences caused by various modeling errors by developing a linear time varying system that describes the trajectory errors, with expressions to transfer the trajectory errors across moving segment transitions. A numerical example is presented for a complete commercial aircraft descent trajectory consisting of several flight segments.

Jackson, Michael R. C.↗

SU-F-303-17: Real Time Dose Calculation of MRI Guided Co-60 Radiotherapy Treatments On Free Breathing Patients, Using a Motion Model and Fast Monte Carlo Dose Calculation

Purpose: To demonstrate real-time dose calculation of free-breathing MRI guided Co−60 treatments, using a motion model and Monte-Carlo dose calculation to accurately account for the interplay between irregular breathing motion and an IMRT delivery. Methods: ViewRay Co-60 dose distributions were optimized on ITVs contoured from free-breathing CT images of lung cancer patients. Each treatment plan was separated into 0.25s segments, accounting for the MLC positions and beam angles at each time point. A voxel-specific motion model derived from multiple fast-helical free-breathing CTs and deformable registration was calculated for each patient. 3D images for every 0.25s of a simulated treatment were generated in real time, here using a bellows signal as a surrogate to accurately account for breathing irregularities. Monte-Carlo dose calculation was performed every 0.25s of the treatment, with the number of histories in each calculation scaled to give an overall 1% statistical uncertainty. Each dose calculation was deformed back to the reference image using the motion model and accumulated. The static and real-time dose calculations were compared. Results: Image generation was performed in real time at 4 frames per second (GPU). Monte-Carlo dose calculation was performed at approximately 1frame per second (CPU), giving a total calculation time of approximately 30 minutes per treatment. Results show both cold- and hot-spots in and around the ITV, and increased dose to contralateral lung as the tumor moves in and out of the beam during treatment. Conclusion: An accurate motion model combined with a fast Monte-Carlo dose calculation allows almost real-time dose calculation of a free-breathing treatment. When combined with sagittal 2D-cine-mode MRI during treatment to update the motion model in real time, this will allow the true delivered dose of a treatment to be calculated, providing a useful tool for adaptive planning and assessing the effectiveness of gated treatments.

60 APPLIED LIFE SCIENCES↗

Early Expansion of the Intracranial CSF Volume After Palliative Whole-Brain Radiotherapy: Results of a Longitudinal CT Segmentation Analysis

Purpose: To assess cerebral atrophy after radiotherapy, we measured intracranial cerebrospinal fluid volume (ICSFV) over time after whole-brain radiotherapy (WBRT) and compared it with published normal-population data. Methods and Materials: We identified 9 patients receiving a single course of WBRT (30 Gy in 10 fractions over 2 weeks) for ipsilateral brain metastases with at least 3 years of computed tomography follow-up. Segmentation analysis was confined to the tumor-free hemi-cranium. The technique was semiautomated by use of thresholds based on scanned image intensity. The ICSFV percentage (ratio of ICSFV to brain volume) was used for modeling purposes. Published normal-population ICSFV percentages as a function of age were used as a control. A repeated-measures model with cross-sectional (between individuals) and longitudinal (within individuals) quadratic components was fitted to the collected data. The influence of clinical factors including the use of subependymal plate shielding was studied. Results: The median imaging follow-up was 6.25 years. There was an immediate increase (p < 0.0001) in ICSFV percentage, which decelerated over time. The clinical factors studied had no significant effect on the model. Conclusions: WBRT immediately accelerates the rate of brain atrophy. This longitudinal study in patients with brain metastases provides a baseline against which the potential benefits of more localized radiotherapeutic techniques such as radiosurgery may be compared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure and thermomechanical properties relationship of segmented thermoplastic polyurethane (TPU)

Thermoplastic polyurethanes (TPU) are important polymeric materials for seals. In competition with Acrylonitrile butadiene rubbers (NBR), TPU exhibits higher strength and a considerable better abrasion resistance. The advantage of NBR over TPU is a smaller compression set but however TPU excels in its much shorter processing cycle times. Generally a TPU is a block copolymer composed of hard and soft segments, which plays an important role in determining the material properties. TPU can be processed either to ready moulded parts or can be incorporated by multi component moulding, in both cases it shows decent mechanical properties. In the present work, the relationship between melt-process induced TPU morphology and resultant thermo mechanical properties were examined and determined by means of quasi-static tensile test, creep experiment, tension test and dynamical mechanical analysis (DMA). Scanning electron beam microscope (SEM) and differential scanning calorimeter (DSC) were used to study the morphology of the samples. A significant mathematical description of the stress-strain behaviour of TPU was found using a 3 term approach. Moreover it became evident that processing conditions such as processing temperature have crucial influence on morphology as well as short and long-term performance. To be more precise, samples processed at higher temperatures showed a lack of large hard segment agglomerates, a smaller strength for strains up to 250% and higher creep compliance.

36 MATERIALS SCIENCE↗

Petascale system management experiences.

Petascale High-Performance Computing (HPC) systems are among the largest systems in the world. Intrepid, one such system, is a 40,000 node, 556 teraflop Blue Gene/P system that has been deployed at Argonne National Laboratory. In this paper, we provide some background about the system and our administration experiences. In particular, due to the scale of the system, we have faced a variety of issues, some surprising to us, that are not common in the commodity world. We discuss our expectations, these issues, and approaches we have used to address them. HPC systems are a bellwether for computing systems at large, in multiple regards. HPC users are motivated by the need for absolute performance; this results in two important pushes. HPC users are frequently early adopters of new technologies and techniques. Successful technologies, like Infiniband, prove their value in HPC before gaining wider adoption. Unfortunately, this early adoption alone is not sufficient to achieve the levels of performance required by HPC users; parallelism must also be harnessed. Over the last 15 years, beowulf clustering has provided amazing accessibility to non-HPC-savvy and even non-technical audiences. During this time, substantial adoption of clustering has occurred in many market segments unrelated to computational science. A simple trend has emerged: the scale and performance of high-end HPC systems are uncommon at first, but become commonplace over the course of 3-5 years. For example, in early 2003, several systems on the Top500 list consisted of either 1024 nodes or 4096-8192 cores. In 2008, such systems are commonplace. The most recent generation of high-end HPC systems, so called petascale systems, are the culmination of years of research and development in research and academia. Three such systems have been deployed thus far. In addition to the 556 TF Intrepid system at Argonne National Laboratory, a 596 TF Blue Gene/L-based system has been deployed at Lawrence Livermore National Laboratory, and a 504 TF Opteron-based system has been deployed at Texas Advanced Computing Center (TACC). Intrepid is comprised of 40,960 nodes with a total of 163,840 cores. While systems like these are uncommon now, we expect them to become more widespread in the coming years. The scale of these large systems impose several requirements upon system architecture. The need for scalability is obvious, however, power efficiency and density constraints have become increasingly important in recent years. At the same time, because the size of administrative staff cannot grow linearly with the system size, more efficient system management techniques are needed. In this paper we will describe our experiences administering Intrepid. Over the last year, we have experienced a number of interesting challenges in this endeavor. Our initial expectation was for scalability to be the dominant system issue. This expectation was not accurate. Several issues expected to have minor impact have played a much greater role in system operations. Debugging, due to the large numbers of components used in scalable system operations, has become a much more difficult endeavor. The system has a sophisticated monitoring system, however, the analysis of this data has been problematic. These issues are not specific to HPC workloads in any way, so we expect them to be of general interest. This paper consists of three major parts. First, we will provide a detailed overview of several important aspects of Intrepid's hardware and software. In this, we will highlight aspects that have featured prominently in our system management experiences. Next, we will describe our administration experiences in detail. Finally, we will draw some conclusions based on these experiences. In particular, we will discuss the implications for the non-HPC world, system managers, and system software developers.

99 GENERAL AND MISCELLANEOUS↗

Particle tracking during Ostwald ripening using time-resolved laboratory X-ray microtomography

Laboratory X-ray microtomography is investigated as a method for obtaining time-resolved images of microstructural coarsening of the semisolid state of Al–5 wt.% Cu samples during Ostwald ripening. Owing to the 3D imaging capability of tomography, this technique uniquely provides access to the growth rates of individual particles, thereby not only allowing a statistical characterization of coarsening—as has long been possible by conventional metallography—but also enabling quantification of the influence of local environment on particle boundary migration. The latter information is crucial to understanding growth kinetics during Ostwald ripening at high volume fractions of the coarsening phase. Automated image processing and segmentation routines were developed to close gaps in the network of particle boundaries and to track individual particles from one annealing step to the next. The particle tracking success rate places an upper bound of only a few percent on the likelihood of segmentation errors for any given particle. The accuracy of particle size trajectories extracted from the time-resolved tomographic reconstructions is correspondingly high. Statistically averaged coarsening data and individual particle growth rates are in excellent agreement with the results of prior experimental studies and with computer simulations of Ostwald ripening. - Highlights: • Ostwald ripening in Al–5 wt.% Cu measured by laboratory X-ray microtomography • Time-resolved measurement of individual particle growth • Automated segmentation routines developed to close gaps in particle boundary network • Particle growth/shrinkage rates deviate from LSW model prediction.

36 MATERIALS SCIENCE↗

A Multiphase Validation of Atlas-Based Automatic and Semiautomatic Segmentation Strategies for Prostate MRI

Purpose: To perform a rigorous technological assessment and statistical validation of a software technology for anatomic delineations of the prostate on MRI datasets. Methods and Materials: A 3-phase validation strategy was used. Phase I consisted of anatomic atlas building using 100 prostate cancer MRI data sets to provide training data sets for the segmentation algorithms. In phase II, 2 experts contoured 15 new MRI prostate cancer cases using 3 approaches (manual, N points, and region of interest). In phase III, 5 new physicians with variable MRI prostate contouring experience segmented the same 15 phase II datasets using 3 approaches: manual, N points with no editing, and full autosegmentation with user editing allowed. Statistical analyses for time and accuracy (using Dice similarity coefficient) endpoints used traditional descriptive statistics, analysis of variance, analysis of covariance, and pooled Student t test. Results: In phase I, average (SD) total and per slice contouring time for the 2 physicians was 228 (75), 17 (3.5), 209 (65), and 15 seconds (3.9), respectively. In phase II, statistically significant differences in physician contouring time were observed based on physician, type of contouring, and case sequence. The N points strategy resulted in superior segmentation accuracy when initial autosegmented contours were compared with final contours. In phase III, statistically significant differences in contouring time were observed based on physician, type of contouring, and case sequence again. The average relative timesaving for N points and autosegmentation were 49% and 27%, respectively, compared with manual contouring. The N points and autosegmentation strategies resulted in average Dice values of 0.89 and 0.88, respectively. Pre- and postedited autosegmented contours demonstrated a higher average Dice similarity coefficient of 0.94. Conclusion: The software provided robust contours with minimal editing required. Observed time savings were seen for all physicians irrespective of experience level and baseline manual contouring speed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Friction Stir Spot Welding of DP780 Carbon Steel

Friction stir spot welds were made in uncoated and galvannealed DP780 sheets using polycrystalline boron nitride stir tools. The tools were plunged at either a single continuous rate or in two segments consisting of a relatively high rate followed by a slower rate of shorter depth. Welding times ranged from 1 to 10 s. Increasing tool rotation speed from 800 to 1600 rev min{sup -1} increased strength values. The 2-segment welding procedures also produced higher strength joints. Average lap shear strengths exceeding 10 {center_dot} 3 kN were consistently obtained in 4 s on both the uncoated and the galvannealed DP780. The likelihood of diffusion and mechanical interlocking contributing to bond formation was supported by metallographic examinations. A cost analysis based on spot welding in automobile assembly showed that for friction stir spot welding to be economically competitive with resistance spot welding the cost of stir tools must approach that of resistance spot welding electrode tips.

36 MATERIALS SCIENCE↗

Hyperspectral Detection of the Fluorescence Shift between Chirality-Sorted Empty and Water-Filled Single-Wall Carbon Nanotube Enantiomers

Single-wall carbon nanotubes (SWCNTs) have extraordinary electronic and optical properties that depend strongly on their exact chiral structure and their interaction with their inner and outer environment. The fluorescence (PL) of semiconducting SWCNTs, for instance, will shift depending on the molecules with which the SWCNT’s hollow core is filled. These interaction-induced shifts are challenging to resolve on the ensemble level in samples containing a mixture of different filling contents due to the relatively large inhomogeneous line width of the ensemble SWCNT PL compared to the size of these shifts. To circumvent this inhomogeneous broadening, single-tube spectroscopy and hyperspectral imaging are often applied, which until now required time-consuming statistical studies. Here, we present hyperspectral PL microscopy combined with automated SWCNT segmenting based on either principal component analysis or a convolutional neural network, capable of both spatially and spectrally resolving the PL along the length of many individual SWCNTs at the same time and automatically fitting peak positions and line widths of individual SWCNTs. The methodology is demonstrated by accurately determining the emission shifts and line widths of thousands of left- and right-handed empty and water-filled SWCNTs coated with a chiral surfactant, resulting in four statistical distributions which cannot be resolved in ensemble spectroscopy of unsorted samples. The results demonstrate a robust method to quickly probe ensemble properties with single-enantiomer spectral resolution. Moreover, it promises to be an absolute quantitative method to characterize the relative abundances of SWCNTs with different handedness or filling content in macroscopic samples, simply by counting individual species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Progress Update on Segmentation of Neutron Tomographic Images, 2018

The present report documents the techniques developed to segment fast-neutron tomographic images of objects consisting of assemblies of machined parts with distinct boundaries. This report satisfies the fiscal year 2018 technical deliverable for project OR16-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons,” to report on the extension of geometric shape-finding algorithms to three dimensions. The project has two overall goals. The first of these goals is to extend associated-particle fast-neutron transmission and, particularly, induced-reaction tomographic imaging algorithms to three dimensions. This aspect of the project is beyond the scope of this report. The second goal is to automatically segment the resultant tomographic images into constituent parts and then extract information about the parts, such as the class of shape and potentially the shape parameters. This report describes progress for the image segmentation part of the project. Imaging techniques have been developed as high-confidence methods for confirming the presence and configuration of special nuclear materials (SNM). This high confidence is achieved at the cost of revealing considerable information that may be undesirable to share with the operator of the equipment. One potential way to make use of the high-confidence of imaging methods without revealing imaging data is to employ automated analysis that can extract meaningful attributes of the SNM without showing imaging data to the operator. An essential step of this automated analysis is the segmentation of the image into its constituent parts. For example, a three-dimensional (3D) fast-neutron tomographic image of an assembly containing uranium could be reconstructed and then segmented into discrete parts. The properties of a constituent part identified as uranium would be of interest and could be extracted. For instance, the volume and density of the part would together determine its mass. Moreover, its shape might be expected to fall into a particular geometric class, such as a cube, cylinder, or sphere, and the parameters of the shape (such as side length, height, or diameter) would be expected to fall in a given range. In such an analysis, automated identification of the boundaries and properties of the uranium part is an essential step. A key goal of the present work is to infer the boundaries of objects in fast-neutron tomographic images via the general method of image segmentation. Development of this capability can be broken into more manageable steps, including 1. operator-guided segmentation of two-dimensional (2D) fast-neutron tomographic images, 2. operator-guided segmentation of 3D fast-neutron tomographic images, 3. development of automated segmentation algorithms, and 4. extraction of shape parameters from constituent volumes in 3D. In the first year, the project team reported progress on the first step. Last year, progress on the second step, the extension into 3D, was reported with application to simulated data. The present report describes additional progress on the second step, and progress toward the third step, automated segmentation algorithms. In particular, a multiphase level set approach for image segmentation in three dimensions has been applied to measured 3D data for the first time. Activities related to the fourth step will also be reported, but it will focus on estimation of 3D volumes rather than shape parameters. In this report, the steps before image segmentation will be described, and the multiphase level sets approach to image segmentation will be briefly reviewed. This will be followed by a discussion of the issues encountered when applying the level set technique to measured 3D transmission images, and then a description of the inclusion of induced-reaction data will be provided. Finally, segmentation results for various measured target assemblies will be presented and the image segmentation portion of this project will be summarized and future directions will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗