Search NASA⌕ Search

SEARCH · Search NASA

Results for “value analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Analysis of the theoretical bias in dark matter direct detection

Fitting the model ''A'' to dark matter direct detection data, when the model that underlies the data is ''B'', introduces a theoretical bias in the fit. We perform a quantitative study of the theoretical bias in dark matter direct detection, with a focus on assumptions regarding the dark matter interactions, and velocity distribution. We address this problem within the effective theory of isoscalar dark matter-nucleon interactions mediated by a heavy spin-1 or spin-0 particle. We analyze 24 benchmark points in the parameter space of the theory, using frequentist and Bayesian statistical methods. First, we simulate the data of future direct detection experiments assuming a momentum/velocity dependent dark matter-nucleon interaction, and an anisotropic dark matter velocity distribution. Then, we fit a constant scattering cross section, and an isotropic Maxwell-Boltzmann velocity distribution to the simulated data, thereby introducing a bias in the analysis. The best fit values of the dark matter particle mass differ from their benchmark values up to 2 standard deviations. The best fit values of the dark matter-nucleon coupling constant differ from their benchmark values up to several standard deviations. We conclude that common assumptions in dark matter direct detection are a source of potentially significant bias.

79 ASTRONOMY AND ASTROPHYSICS↗

What can the CMB tell about the microphysics of cosmic reheating?

In inflationary cosmology, cosmic reheating after inflation sets the initial conditions for the hot big bang. We investigate how CMB data can be used to study the effective potential and couplings of the inflaton during reheating to constrain the underlying microphysics. If there is a phase of preheating that is driven by a parametric resonance or other instability, then the thermal history and expansion history during the reheating era depend on a large number of microphysical parameters in a complicated way. In this case the connection between CMB observables and microphysical parameters can only established with intense numerical studies. Such studies can help to improve CMB constraints on the effective inflaton potential in specific models, but parameter degeneracies usually make it impossible to extract meaningful best-fit values for individual microphysical parameters. If, on the other hand, reheating is driven by perturbative processes, then it can be possible to constrain the inflaton couplings and the reheating temperature from CMB data. This provides an indirect probe of fundamental microphysical parameters that most likely can never be measured directly in the laboratory, but have an immense impact on the evolution of the cosmos by setting the stage for the hot big bang.

79 ASTRONOMY AND ASTROPHYSICS↗

"BAAE" instabilities observed without fast ion drive

The instability that was previously identified as a fast-ion driven beta-induced Alfv´en-acoustic eigenmode (BAAE) in DIII-D was misidentified. In a dedicated experiment, low frequency modes (LFM) with characteristic “Christmas light” patterns of brief instability linked to the safety factor evolution occur in plasmas with electron temperature T e ≳ 2.1 keV but modest beta. To isolate the importance of different driving gradients on these modes, the electron cyclotron heating power and 80 keV, sub-Alfv´enic neutral beams are altered for 50-100 ms durations in reproducible discharges. Although beta-induced Alfv´en eigenmodes and reversed-shear Alfv´en eigenmodes stabilize when beam injection ceases (as expected for a fast-ion driven instability), the low frequency modes that were called BAAEs persist. Data mining reveals that characteristic LFM instabilities can occur in discharges with no beam heating but strong electron cyclotron heating. A large database of over 1000 discharges shows that LFMs are only unstable in plasmas with hot electrons but modest overall beta. The experimental LFMs have low frequencies (comparable to diamagnetic drift frequencies) in the plasma frame, occur near the minimum of the safety factor q min , and appear when q min is close to rational values. In conclusion, theoretical analysis suggests that the LFMs are a low frequency reactive instability of predominately Alfv´enic polarization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3XMM J185246.6+003317: ANOTHER LOW MAGNETIC FIELD MAGNETAR

We study the outburst of the newly discovered X-ray transient 3XMM J185246.6+003317, re-analyzing all available XMM-Newton observations of the source to perform a phase-coherent timing analysis, and derive updated values of the period and period derivative. We find the source rotating at P = 11.55871346(6) s (90% confidence level; at epoch MJD 54728.7) but no evidence for a period derivative in the seven months of outburst decay spanned by the observations. This translates to a 3σ upper limit for the period derivative of P-dot <1.4×10{sup −13} s s{sup –1}, which, assuming the classical magneto-dipolar braking model, gives a limit on the dipolar magnetic field of B {sub dip} < 4.1 × 10{sup 13} G. The X-ray outburst and spectral characteristics of 3XMM J185246.6+003317 confirm its identification as a magnetar, but the magnetic field upper limit we derive defines it as the third ''low-B'' magnetar discovered in the past 3 yr, after SGR 0418+5729 and Swift J1822.3–1606. We have also obtained an upper limit to the quiescent luminosity (<4 × 10{sup 33} erg s{sup –1}), in line with the expectations for an old magnetar. The discovery of this new low field magnetar reaffirms the prediction of about one outburst per year from the hidden population of aged magnetars.

79 ASTRONOMY AND ASTROPHYSICS↗

Isotope shifts in francium isotopes 206-213 Fr and 221 Fr

We present the isotope shifts of the 7 s 1/2 to 7 p 1/2 transition for francium isotopes ²⁰⁶⁻²¹³Fr with reference to ²²¹Fr collected from two experimental periods. The shifts are measured on a sample of atoms prepared within a magneto-optical trap by a fast sweep of radio-frequency sidebands applied to a carrier laser. King plot analysis, which includes literature values for 7 s 1/2 to 7 p 3/2 isotope shifts, provides a field shift constant ratio of 1.0520(10) and a difference between the specific mass shift constants of 170(100) GHz amu between the D₁ and D₂ transitions, of sufficient precision to differentiate between ab initio calculations.

Collister, R.↗

Orbital angular momentum in the nucleon

Analysis of the measured value of the integrated d-bar-u-bar asymmetry (I{sub fas} = 0.147 +- 0.027) in the nucleon show it to arise from nucleon fluctuations into baryon plus pion. Requiring angular momentum conservation in these fluctuations shows the associated orbital angular momentum is equal to the value of the flavor asymmetry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theoretical study of positive-parity doublet bands in {sup 124}Cs

Positive-parity doublet bands in the odd-odd nucleus {sup 124}Cs have been studied by using the two quasiparticles plus a triaxial rotor model. The energy spectra and electromagnetic properties are calculated and compared with the available experimental results. Good agreement is obtained in the present calculation. The chiral geometry and its evolution with angular momentum for doublet bands in {sup 124}Cs is also exhibited and discussed based on the analysis of the expectation values and the probability distributions of the angular momentum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Violation of quark-hadron duality and spectral chiral moments in QCD

We analyze the spectral moments of the V-A two-point correlation function. Using all known short-distance constraints and the most recent experimental data from tau decays, we determine the lowest spectral moments, trying to assess the uncertainties associated with the so-called violations of quark-hadron duality. We have generated a large number of acceptable spectral functions, satisfying all conditions, and have used them to extract the wanted hadronic parameters through a careful statistical analysis. We obtain accurate values for the {chi}PT couplings L{sub 10} and C{sub 87}, and a realistic determination of the dimension six and eight contributions in the operator product expansion, O{sub 6}=(-5.4{sub -1.6}{sup +3.6}){center_dot}10{sup -3} GeV{sup 6} and O{sub 8}=(-8.9{sub -7.4}{sup +12.6}){center_dot}10{sup -3} GeV{sup 8}, showing that the duality-violation effects have been underestimated in previous literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BICEP/Keck XXI: Constraints on early-Universe parity violation from multipole-dependent birefringence

We present the first constraints on multipole-dependent cosmic birefringence using CMB polarization data from the BK18 dataset, which combines observations from BICEP2, Array, and BICEP3 at frequencies of 95, 150, and 220 GHz. Photon coupling to an axionlike field leads to the rotation of CMB polarization, inducing nonzero cross-correlations. We show that a multipole-dependent rotation imprints a distinct signature in the polarization spectra that can be constrained. Specifically, we consider an early dark energy (EDE) scenario in which a pseudoscalar field couples to photons through a Chern-Simons interaction, generating a polarization rotation with multipole dependence. We introduce a phenomenological as a step function, obtaining constraints on the step function size consistent with zero, with uncertainties less than (68% CL). In addition, using multi-frequency , , and cross spectra, along with robust BICEP/ foreground treatment and likelihood framework, we derive constraints on the axion-photon coupling amplitude for several choices of EDE parameters. For the baseline best-fit value from the 2018 analysis, we obtain (68% CL), consistent with previous limits.

Ade, P A R↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-05: Fast Volumetric MRI On An MRI-Linac Enables On-Line QA On Dose Deposition in the Patient

Purpose: The introduction of the MRI-linac in radiotherapy brings MRI-guided treatment with daily plan adaptions within reach. This paradigm demands on-line QA. With its ability to perform continuous volumetric imaging in an outstanding soft-tissue contrast, the MRI- linac promises to elucidate the dose deposition process during a treatment session. Here we study for a prostate case how dynamic MRI combined with linac machine parameters and a fast dose-engine can be used for on-line dose accumulation. Methods: Prostate imaging was performed in healthy volunteer on a 1.5T MR-scanner (Philips, Best, NL) according to a clinical MR-sim protocol, followed by 10min of dynamic imaging (FLASH, 4s/volume, FOV 40×40×12cm{sup 3}, voxels 3×3×3mm{sup 3}, TR/TE/α=3.5ms/1.7ms/5°). An experienced radiation oncologist made delineations, considering the prostate CTV. Planning was performed on a two-compartment pseudoCT (air/water density) according to clinical constraints (77Gy in PTV) using a Monte-Carlo (MC) based TPS that accounts for magnetic fields. Delivery of one fraction (2.2Gy) was simulated on an emulator for the Axesse linac (Elekta, Stockholm, SE). Machine parameters (MLC settings, gantry angle, dose rate, etc.) were recorded at 25Hz. These were re-grouped per dynamic volume and fed into the MC-engine to calculate a dose delivered for each of the dynamics. Deformations derived from non-rigid registration of each dynamic against the first allowed dose accumulation on a common reference grid. Results: The DVH parameters on the PTV compared to the optimized plan showed little changes. Local deformations however resulted in local deviations, primarily around the air/rectum interface. This clearly indicates the potential of intra-fraction adaptations based on the accumulated dose. Application in each fraction helps to track the influence of plan adaptations to the eventual dose distribution. Calculation times were about twice the delivery time. Conclusion: The current Result paves the way to perform on-line treatment delivery QA on the MRI-linac in the near future.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-04: A Preliminary Investigation of Indicators for Treatment Outcomes of CT Guided Cervical Cancer Brachytherapy

Purpose: To identify indicators for recurrence in cervical cancer patients treated with high-dose-rate brachytherapy (HDR-BT). Methods: A total of 37 biopsy proven uterine cervical cancer patients of stage IB-IVA treated between 2011 and 2015 were included in this study. All patients were treated with 37.8–52.2Gy of external beam radiotherapy (EBRT) plus 5 × 5.0–6.5Gy of HDR-BT. Patient age, standard deviation of high-risk clinical tumor volume (HR-CTVSD) collected throughout HDR-BT, and D90 (EQD2, α/β=10Gy) of the HR-CTV were investigated as potential indicators for local/distant recurrence using ROC analysis. The optimal cutoff value was identified through the Youden index and was subsequently used to obtain a group assignment for all patients. Another two comparing groups were defined per evidence of post-EBRT tumor shrinkage based on the pre-HDR MR scan. Kaplan-Meier curves were generated for recurrence-free proportions for comparing groups where time was measured from the final HDR treatment date to the date of the final follow-up exam and compared through Cox regression. Results: Patients had a median follow-up of 12 months, where 16% had local pelvic recurrence and 16% had distant recurrence. HR-CTVSD was identified as a statistically significant indicator for recurrence (AUC=0.802, p=0.007) compared to D90 (AUC=0.655, p=0.167) and patient age (AUC=0.683, p=0.103). HR-CTVSD of 6.26cc was chosen as the optimal cutoff value, which was used as the basis for patient group assignment. Patients with HR-CTVSD>6.26cc had a hazard ratio of 3.92 (95% CI-1.37, 11.24; p=0.011) for recurrence compared to HRCTVSD≤ 6.26cc. Patients without evidence of post-EBRT tumor shrinkage compared to those with had a hazard ratio of 4.28 (95% CI-1.14, 16.15; p=0.032) for recurrence. Conclusion: HR-CTVSD was identified as an indicator for recurrence and an optimal value of 6.26cc was established in our study. In addition, patients without evidence of post-EBRT tumor shrinkage demonstrated an increased recurrence rate.

60 APPLIED LIFE SCIENCES↗

Ionic conductivity of binary fluorides of potassium and rare earth elements

The ionic conductivity s of KYF{sub 4} and K{sub 2}RF{sub 5} single crystals (R = Gd, Ho, Er) and KNdF{sub 4} and K{sub 2}RF{sub 5} ceramic samples (R = Dy, Er) has been studied in the temperature range of 340–500°C. A comparative analysis of the σ values for these objects has been performed. Binary fluorides of potassium and rare earth elements were synthesized by the hydrothermal method (temperature 480°C, pressure 100–150 MPa) in the R{sub 2}O{sub 3}–KF–H{sub 2}O systems. The σ values of tetraf luorides are 3 × 10{sup –5} S/cm (KYF{sub 4} single crystal) and 3 × 10{sup –6} S/cm (KNdF{sub 4} ceramics) at 435°C. A K{sub 2}ErF{sub 5} single crystal with σ = 1.2 × 10{sup –4} S/cm at 435°C has the maximum value of ionic conductivity among pentafluorides. The anisotropy of ionic transport was found in K{sub 2}HoF{sub 5} single crystals, σ{sub ∥c}/σ{sub ⊥c} = 2.5, where σ{sub ∥c} and σ{sub ⊥c} are, respectively, the conductivities along the crystallographic c axis and in the perpendicular direction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-perturbative effects for the Quark-Gluon Plasma equation of state

The non-perturbative effects for the Quark-Gluon Plasma (QGP) equation of state (EoS) are considered. The modifications of the bag model EoS are constructed to satisfy the main qualitative features observed for the QGP EoS in the lattice QCD calculations. A quantitative comparison with the lattice results is done for the SU(3) gluon plasma and for the QGP with dynamical quarks. Our analysis advocates a negative value of the bag constant B.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simplified parametric scenarios of the Minimal Supersymmetric Standard Model after the discovery of the Higgs boson

Constraints on the parameter space of theMinimal Supersymmetric StandardModel (MSSM) that are imposed by the experimentally observed mass of the Higgs boson (m{sub H} = 125 GeV) upon taking into account radiative corrections within an effective theory for the Higgs sector in the decoupling limit are examined. It is also shown that simplified approximations for radiative corrections in theMSSM Higgs sector could reduce, to a rather high degree of precision, the dimensionality of the multidimensionalMSSM parameter space to two.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for massive long-lived particles decaying semileptonically at ${\sqrt{s}}=13\,\hbox {TeV}$

A search is performed for massive long-lived particles (LLPs) decaying semileptonically into a muon and two quarks. Two kinds of LLP production processes were considered. In the first, a Higgs-like boson with mass from 30 to 200\,GeV\!/c 2 is produced by gluon fusion and decays into two LLPs. The analysis covers LLP mass values from 10\,GeV\!/c 2 up to about one half the Higgs-like boson mass. The second LLP production mode is directly from quark interactions, with LLP masses from 10 to 90\,GeV\!/c 2 . The LLP lifetimes considered range from 5 to 200 ps. This study uses LHCb data collected from proton-proton collisions at $\sqrt{s}$=13\,TeV, corresponding to an integrated luminosity of 5.4\,fb -1 . No evidence of these long-lived states has been observed, and upper limits on the production cross-section times branching ratio have been set for each model considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Membrane Thickness Impact on Chemical Degradation Rates

Abstract A comprehensive investigation of PFSA membrane chemical degradation rates as a function of thickness (8-20 µm) is reported. The two-pronged study was conducted on bare membranes and as components of chemically-mitigated and mechanically-reinforced, state-of-the-art (SOA) membrane electrode assemblies (MEAs). The bare membranes were subjected to H2O2 vapor test and MEAs were degraded under OCV conditions, both at 90°C. Both test types employed fluoride release rates (FRR) to monitor chemical degradation rates. Vapor tests revealed that area-specific degradation rates were positively correlated with membrane thickness, but thickness normalized degradation rates were independent of thickness. Open-circuit voltage (OCV) investigations spanning the membrane thickness series of MEAs was probed via a 27-experiment 3(4-1) fractional factorial experimental design. Statistical analysis of the FRR values revealed that chemical degradation rates were dominated by the relative humidity value and that the area-specific degradation rates of MEAs were independent of membrane thickness. The OCV chemical durability insensitivity to membrane thickness is supported by on-load membrane chemical durability studies at the stack level. The results suggest that ,despite smaller ionomer inventory, SOA thin membranes and MEAs are not greatly disadvantaged relative to thicker membranes from a chemical durability perspective, provided oxidative stress levels are controlled throughout application lifetime.

Coms, Frank D. (ORCID:0000000249160350)↗