Search NASA⌕ Search

SEARCH · Search NASA

Results for “variance estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Quantification of Physical and Numerical Mixing in a Coastal Ocean Model Using Salinity Variance Budgets

Numerical mixing, the spurious mixing primarily generated by the discretization of advection, is often significant in estuarine and coastal models due to sharp, energetic fronts. In this study, we compare on- and offline estimates of numerical mixing in a submesoscale-resolving realistic simulation of the ocean state over the Texas-Louisiana continental shelf. While offline estimates of numerical mixing differ from online estimates, offline methods may be the only analysis available. This study offers insight into the differences between the on- and offline methods. We use two methods to estimate numerical mixing offline, based on salinity squared $s^2$ and volume-mean salinity variance $s^{\prime^2}$. Numerical mixing estimated from the $s^{\prime^2}$ budget is generally within 60\% of the magnitude for the online method but captures the temporal variability well. However, the $s^2$ budget compares poorly due to larger truncation errors associated with the tendency and advection terms, which can be reduced by increasing the model output frequency. We also investigate the effects of horizontal resolution on numerical mixing using a two-way nested grid. The volume-integrated numerical mixing constitutes 57\% of the bulk physical mixing -- the mixing prescribed by the turbulence closure scheme -- in the coarse model and may exceed the physical mixing by half an order of magnitude. We find that numerical mixing is reduced by 35\% on average in the nested model, less than expected based on scaling of the numerical mixing for an upwind advection scheme, likely due to new dynamical processes that emerge in the nested simulation.

54 ENVIRONMENTAL SCIENCES↗

Estimation of the mixing layer height over a high altitude site in Central Himalayan region by using Doppler lidar

A Doppler lidar was installed at Manora Peak, Nainital (29.4 N; 79.2 E, 1958 amsl) to estimate mixing layer height for the first time by using vertical velocity variance as basic measurement parameter for the period September-November 2011. Mixing layer height is found to be located ~0.57 +/- 0.1and 0.45 +/- 0.05km AGL during day and nighttime, respectively. The estimation of mixing layer height shows good correlation (R>0.8) between different instruments and with different methods. Our results show that wavelet co-variance transform is a robust method for mixing layer height estimation.

Shukla, K. K.↗

Vestibular adaptation in man - Effects of increased acceleration during different phases of adaptation.

The purpose of this study was to investigate the course of vestibular adaptation following a temporary increase in angular acceleration (A). Eight normal subjects, who were rotated in a precision rotation device, gave periodic magnitude estimates of their perceived velocity throughout a prolonged 1 deg per sec per sec acceleration, which was briefly increased to either 2 or 3 deg per sec per sec at four points in the adaptation cycle. The data, tested with analysis of variance, showed that the size of the magnitude estimates was influenced by the magnitude and position of the altered A. The duration of subjective response was affected only by the position of the altered A.

Luster, T.↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Comparison Of Hybrid Methods For Global Variance Reduction In Shielding Calculations

For Monte Carlo shielding problems that calculate a mesh tally over the entire problem, the relative uncertainties computed for each voxel can vary widely. This can lead to unacceptably long run times in order to reduce the uncertainties in all areas of the problem to a reasonably low level. Hybrid methods using estimates from deterministic calculations to create importance maps for variance reduction in Monte Carlo calculations have been successfully used to optimize the calculation of specific tallies. For the global problem, several methods have been proposed that create importance maps that distribute Monte Carlo particles in such a way as to achieve a more uniform distribution of relative uncertainty across the problem. The goal is to compute a mesh tally with nearly the same relative uncertainties in the low flux/dose areas as in the high flux/dose areas. Methods based on only forward deterministic estimates and methods using both forward and adjoint deterministic methods have been implemented the SCALE/MAVRIC package and have been compared against each other by computing global mesh tallies on several representative shielding problems. Methods using both forward and adjoint estimates provide better performance for computing more uniform relative uncertainties across a global mesh tally.

FW-CADIS↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 3, Results, Variability, and Uncertainty

This paper is part three of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. The radionuclides of interest are the 238U series (14 nuclides), the actinium series (headed by 235U; 11 nuclides), and the 232Th series (11 nuclides); primordial radionuclides 87Rb and 40K; cosmogenic and fallout radionuclides 14C and 3H; and purely anthropogenic radionuclides 137Cs-137mBa, 129I and 90Sr-90Y. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Part two described the methods used to organize the data collected in part one and segregate it into the ages and genders defined by the study, imputed missing values from the existing data, apportioned activity in bone, and imputed activity in hollow organ contents and the remainder of the body. This paper estimates equivalent doses to target tissues from source regions and maps target tissues to lists of tissues with International Commission on Radiation Protection (ICRP) tissue-weighting factors or to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue-weighting factors recommended in 1977, 1990, and 2007, are then calculated, and an upper bound of variability of the effective dose is estimated by calculating the average coefficients of variation (CV), assuming all variance is due to variability. Most of the data were for adult males, whose average annual effective dose is estimated to be 337 μSv (CV = 0.65, geometric mean = 283 μSv, geometric standard deviation sG = 1.81) using 2007 ICRP tissue-weighting factors. This result is between the National Council on Radiation Protection & Measurements’ 1987 estimate of 390 μSv (using 1977 wTs) and its 2009 estimate of 285 μSv (using 2007 wTs) and is higher than the United Nations Scientific Committee on the Effects of Atomic Radiation’s 2000 estimate of 310 μSv (using 1990 wTs). The methods and software developed for this project are sufficiently detailed and sufficiently general to be usable with autopsy data from any or all countries.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing the mechanisms governing the daytime evolution of marine stratocumulus using large‐eddy simulation

Large‐eddy simulation (LES) output for a case of thin stratocumulus off the coast of California is examined in a mixed‐layer analysis framework to identify the specific mechanisms responsible for governing the evolution of the cloud system. An equation for cloud‐base height tendency isolates the individual cloud‐modulating mechanisms that control the evolution of boundary‐layer liquid‐water static energy ( S l ) and total water mixing ratio ( q T ). With a suitable spin‐up procedure, the control simulation performs admirably compared with observed estimates of liquid water content, vertical velocity variance, and radiative fluxes sampled during an aircraft field campaign. Investigation of the cloud response to various environmental forcing scenarios was addressed through a suite of sensitivity simulations, including variations in subsidence velocity, surface fluxes, wind shear near the inversion, and radiative forcing. In the control simulation, rising cloud‐base tendencies are associated with entrainment warming/drying and short‐wave absorption, whereas lowering cloud‐base tendencies are driven by long‐wave cooling. Even in the presence of substantial afternoon solar heating, entrainment fluxes remained active. The thin cloud demonstrated unexpected resiliency, with mixed‐layer analysis indicating that, as the short‐wave flux decreases later in the afternoon, the relative contribution of long‐wave cooling often becomes large enough to offset entrainment warming/drying and result in a reversal of cloud‐base tendency. The evolution of cloud‐base tendency is found to be insensitive to the net radiative flux divergence for most of the simulations (liquid water path ranging from ~10–50 g/m 2 ). Error analysis in comparison with LES S l and q T budgets suggests that our method of entrainment flux calculation could be improved by a more complete understanding of entrainment‐layer physics.

McMichael, Lucas A.↗

Data-optimized source modeling with the Backwards Liouville Test–Kinetic method

In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution were used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. Our study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty quantification for molecular property predictions with graph neural architecture search

Graph Neural Networks (GNNs) have emerged as a prominent class of data-driven methods for molecular property prediction. However, a key limitation of typical GNN models is their inability to quantify uncertainties in the predictions. This capability is crucial for ensuring the trustworthy use and deployment of models in downstream tasks. To that end, we introduce AutoGNNUQ, an automated uncertainty quantification (UQ) approach for molecular property prediction. AutoGNNUQ leverages architecture search to generate an ensemble of high-performing GNNs, enabling the estimation of predictive uncertainties. Our approach employs variance decomposition to separate data (aleatoric) and model (epistemic) uncertainties, providing valuable insights for reducing them. In our computational experiments, we demonstrate that AutoGNNUQ outperforms existing UQ methods in terms of both prediction accuracy and UQ performance on multiple benchmark datasets, and generalizes well to out-of-distribution datasets. Additionally, we utilize t-SNE visualization to explore correlations between molecular features and uncertainty, offering insight for dataset improvement. AutoGNNUQ has broad applicability in domains such as drug discovery and materials science, where accurate uncertainty quantification is crucial for decision-making.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A low phase noise microwave source for atomic spin squeezing experiments in {sup 87}Rb

We describe and characterize a simple, low cost, low phase noise microwave source that operates near 6.800 GHz for agile, coherent manipulation of ensembles of {sup 87}Rb. Low phase noise is achieved by directly multiplying a low phase noise 100 MHz crystal to 6.8 GHz using a nonlinear transmission line and filtering the output with custom band-pass filters. The fixed frequency signal is single sideband modulated with a direct digital synthesis frequency source to provide the desired phase, amplitude, and frequency control. Before modulation, the source has a single sideband phase noise near -140 dBc/Hz in the range of 10 kHz-1 MHz offset from the carrier frequency and -130 dBc/Hz after modulation. The resulting source is estimated to contribute added spin-noise variance 16 dB below the quantum projection noise level during quantum nondemolition measurements of the clock transition in an ensemble 7 x 10{sup 5} {sup 87}Rb atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam scattering on an inhomogeneous ensemble of elliptical discs modelling red blood cells in an ectacytometer

We have theoretically studied the effect of difference in particle shapes on the appearance of the diffraction pattern, which arises in the scattering of a laser beam on a dilute suspension of erythrocytes in an ectacytometer. We have proposed data processing algorithms allowing one to estimate the red blood cell shape parameter variance under conditions of laser ectacytometry. The conclusions of the theoretical analysis are verified experimentally. (laser methods in biology)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LARGE AREA SURVEY FOR z = 7 GALAXIES IN SDF AND GOODS-N: IMPLICATIONS FOR GALAXY FORMATION AND COSMIC REIONIZATION

We present results of our large area survey for z'-band dropout galaxies at z = 7 in a 1568 arcmin{sup 2} sky area covering the SDF and GOODS-N fields. Combining our ultra-deep Subaru/Suprime-Cam z'- and y-band (lambda{sub eff} = 1 mum) images with legacy data of Subaru and Hubble Space Telescope, we have identified 22 bright z-dropout galaxies down to y = 26, one of which has a spectroscopic redshift of z = 6.96 determined from Lyalpha emission. The z = 7 luminosity function yields the best-fit Schechter parameters of phi* = 0.69{sup +2.62}{sub -0.55} x 10{sup -3} Mpc{sup -3}, M*{sub UV} = -20.10 +- 0.76 mag, and alpha = -1.72 +- 0.65, and indicates a decrease from z = 6 at a >95% confidence level. This decrease is beyond the cosmic variance in our two fields, which is estimated to be a factor of approx<2. We have found that the cosmic star formation rate density drops from the peak at z = 2-3 to z = 7 roughly by a factor of approx10 but not larger than approx100. A comparison with the reionization models suggests either that the universe could not be totally ionized by only galaxies at z = 7, or more likely that properties of galaxies at z = 7 are different from those at low redshifts having, e.g., a larger escape fraction (approx>0.2), a lower metallicity, and/or a flatter initial mass function. Our SDF z-dropout galaxies appear to form 60 Mpc long filamentary structures, and the z = 6.96 galaxy with Lyalpha emission is located at the center of an overdense region consisting of four UV bright dropout candidates, which might suggest an existence of a well-developed ionized bubble at z = 7.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate predictions from small boxes: variance suppression via the Zel'dovich approximation

Simulations have become an indispensable tool for accurate modelling of observables measured in galaxy surveys, but can be expensive if very large dynamic range in scale is required. We describe how to combine Lagrangian perturbation theory models with N-body simulations to reduce the effects of finite computational volume in the prediction of ensemble average properties in the simulations within the context of control variates. In particular we use the fact that Zel'dovich displacements, computed during initial condition generation for any simulation, correlate strongly with the final density field. Since all the correlators of biased tracers can be computed with arbitrary precision for these displacements, pairing the Zel'dovich `simulation' with the N-body realization allows hundredfold reductions in sample variance for power spectrum or correlation function estimation. Additionally, Zel'dovich control variates can accurately extend matter or tracer field emulators to larger scales than previously possible, as well as improving measurements of statistics in simulations which are inherently limited to small volumes, such as hydrodynamical simulations of galaxy formation and reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Human activities shape global patterns of decomposition rates in rivers

Rivers and streams contribute to global carbon cycling by decomposing immense quantities of terrestrial plant matter. However, decomposition rates are highly variable and large-scale patterns and drivers of this process remain poorly understood. Using a cellulose-based assay to reflect the primary constituent of plant detritus, we generated a predictive model (81% variance explained) for cellulose decomposition rates across 514 globally distributed streams. A large number of variables were important for predicting decomposition, highlighting the complexity of this process at the global scale. Predicted cellulose decomposition rates, when combined with genus-level litter quality attributes, explain published leaf litter decomposition rates with high accuracy (70% variance explained). Finally, our global map provides estimates of rates across vast understudied areas of Earth and reveals rapid decomposition across continental-scale areas dominated by human activities.

54 ENVIRONMENTAL SCIENCES↗

Analysis of the genetic basis of height in large Jewish nuclear families

Despite intensive study, most of the specific genetic factors that contribute to variation in human height remain undiscovered. We conducted a family-based linkage study of height in a unique cohort of very large nuclear families from a founder (Jewish) population. This design allowed for increased power to detect linkage, compared to previous family-based studies. Loci we identified in discovery families could explain an estimated lower bound of 6% of the variance in height in validation families. We showed that these loci are not tagging known common variants associated with height. Rather, we suggest that the observed signals arise from variants with large effects that are rare globally but elevated in frequency in the Jewish population.

59 BASIC BIOLOGICAL SCIENCES↗

GPU Acceleration of Mean Free Path Based Kernel Density Estimators for Monte Carlo Neutronics Simulations

Kernel Density Estimators (KDEs) are a non-parametric density estimation technique that has recently been applied to Monte Carlo radiation transport simulations. Kernel density estimators are an alternative to histogram tallies for obtaining global solutions in Monte Carlo tallies. With KDEs, a single event, either a collision or particle track, can contribute to the score at multiple tally points with the uncertainty at those points being independent of the desired resolution of the solution. Thus, KDEs show potential for obtaining estimates of a global solution with reduced variance when compared to a histogram. Previously, KDEs have been applied to neutronics for one-group reactor physics problems and fixed source shielding applications. However, little work was done to obtain reaction rates using KDEs. This paper introduces a new form of the MFP KDE that is capable of handling general geometries. Furthermore, extending the MFP KDE to 2-D problems in continuous energy introduces inaccuracies to the solution. An ad-hoc solution to these inaccuracies is introduced that produces errors smaller than 4% at material interfaces.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of SAS4A/SASSYS-1 for Steady-State Single-Phase Natural Circulation

The development of numerical software for engineering applications requires the validation of the code against experimental benchmark datasets. To support the validation of SAS4A/SASSYS-1 in simulating the single-phase natural circulation within nuclear reactor systems, high-precision steady-state experiments are performed to capture single-phase natural circulation phenomena on an existing scaled facility with comprehensive instrumentation. Forced convection tests are designed precisely capturing the facility’s critical thermal-hydraulic parameters required for one-dimensional modeling, and a comprehensive single-phase natural circulation dataset is obtained with well-documented experimental uncertainty and facility description. Analysis and discussion based on the finalized dataset confirm the dataset’s ability in capturing dominant phenomena and address important physical interpretation of parameters. The dataset reported in this project provides a valuable benchmark resource for the validation of system analysis codes under single-phase natural circulation inside nuclear reactors. Validation of SAS4A/SASSYS-1 is then performed against the obtained benchmark dataset to confirm the capability of its physics model in simulating the steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators to quantify and restrict numerical errors from discretization. Numerical uncertainty originating from finite maximum pseudo-transient time is also quantified and restricted. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, directly quantifying the simulation output in a Monte Carlo approach. The composition of the output uncertainty is further determined by the estimators of Sobol’ indices through a variance-based sensitivity analysis. With uncertainty quantified for each individual condition, detailed comparison between the simulation results and experimental data is performed covering the whole dataset, which shows consistent agreement for all important quantities. The validation activity reported in this project demonstrates that SAS4A/SASSYS-1 can predict the primary parameters with satisfactorily accuracy under steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bias Impact Analysis and Calibration of UAV-Based Mobile LiDAR System with Spinning Multi-Beam Laser Scanner

Light Detection and Ranging (LiDAR) is a technology that uses laser beams to measure ranges and generates precise 3D information about the scanned area. It is rapidly gaining popularity due to its contribution to a variety of applications such as Digital Building Model (DBM) generation, telecommunications, infrastructure monitoring, transportation corridor asset management and crash/accident scene reconstruction. To derive point clouds with high positional accuracy, estimation of mounting parameters relating the laser scanners to the onboard Global Navigation Satellite System/Inertial Navigation System (GNSS/INS) unit, i.e., the lever-arm and boresight angles, is the foremost and necessary step. This paper proposes a LiDAR system calibration strategy for a Unmanned Aerial Vehicle (UAV)-based mobile mapping system that can directly estimate the mounting parameters for spinning multi-beam laser scanners through an outdoor calibration procedure. This approach is based on the use of conjugate planar/linear features in overlapping point clouds derived from different flight lines. Designing an optimal configuration for calibration is the first and foremost step in order to ensure the most accurate estimates of mounting parameters. This is achieved by conducting a rigorous theoretical analysis of the potential impact of bias in mounting parameters of a LiDAR unit on the resultant point cloud. The dependency of the impact on the orientation of target primitives and relative flight line configuration would help in deducing the configuration that would maximize as well as decouple the impact of bias in each mounting parameter so as to ensure their accurate estimation. Finally, the proposed analysis and calibration strategy are validated by calibrating a UAV-based LiDAR system using two different datasets—one acquired with flight lines at a single flying height and the other with flight lines at two different flying heights. With this being said, the calibration performance is evaluated by analyzing correlation between the estimated system parameters, the a-posteriori variance factor of the Least Squares Adjustment (LSA) procedure and the quality of fit of the adjusted point cloud to planar/linear features before and after the calibration process.

3D point clouds↗