Development and Applications of a Two-dimensional Tip-Tilting Stage System with Nanoradian-Level Positioning Resolution

In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flocking ferromagnetic colloids

Assemblages of microscopic colloidal particles exhibit fascinating collective motion when energized by electric or magnetic fields. The behaviors range from coherent vortical motion to phase separation and dynamic self-assembly. While colloidal systems are relatively simple, understanding their collective response, especially in out of equilibrium conditions, remains elusive. Here, we report on the emergence of flocking and global rotation in the system of rolling ferromagnetic microparticles energized by a vertical alternating magnetic field. By combing experiments and discrete particle simulations, we have identified primary physical mechanisms leading to the emergence of largescale collective motion: spontaneous symmetry breaking of the clock / counterclockwise particle rotation, collisional alignment of particle velocities, and random particle re-orientations due to shape imperfections. We have also shown that hydrodynamic interactions between the particles do not have a qualitative effect on the collective dynamics. Lastly, our findings shed light on the onset of spatial and temporal coherence in a large class of active systems, both synthetic (colloids, swarms of robots, biopolymers) and living (suspensions of bacteria, cell colonies, bird flocks).

36 MATERIALS SCIENCE↗

H I Clouds in the Lower Halo. I. The Galactic All-Sky Survey Pilot Region

We have detected over 400 H I clouds in the lower halo of the Galaxy within the pilot region of the Galactic All-Sky Survey (GASS), a region of the fourth quadrant that spans 18 deg. in longitude, 40 deg. in latitude, and is centered on the Galactic equator. These clouds have a median peak brightness temperature of 0.6 K, a median velocity width of 12.8 km s{sup -1}, and angular sizes {approx}<1deg . The motion of these clouds is dominated by Galactic rotation with a random cloud-to-cloud velocity dispersion of 18 km s{sup -1}. A sample of clouds likely to be near tangent points was analyzed in detail. These clouds have radii on the order of 30 pc and a median H I mass of 630 M{sub sun}. The population has a vertical scale height of 400 pc and is concentrated in Galactocentric radius, peaking at R = 3.8 kpc. This confined structure suggests that the clouds are linked to spiral features, while morphological evidence that many clouds are aligned with loops and filaments is suggestive of a relationship with star formation. The clouds might result from supernovae and stellar winds in the form of fragmenting shells and gas that has been pushed into the halo rather than from a galactic fountain.

99 GENERAL AND MISCELLANEOUS↗

Urbanization may enhance tornado potential: A single case report

Tornadoes pose a risk of catastrophic economic loss and casualty in the United States. Modification of land use by urbanization alters the meteorological conditions that may impact tornado formation and intensification processes. Here we explored the simulated impact of Kansas City urbanization on the tornado potential of a supercell storm. In this studied case, we found that urbanization might enhance tornado potential by a) strengthening the low-level streamwise vorticity in the storm inflow region, thus forming stronger rotating updrafts; and b) intensifying near-surface horizontal vorticity near the boundary of the forward-flank cold pool which increases the ingestion, tilting, and stretching of streamwise horizontal vorticity into vertical vorticity. The former results from the stronger east-to-west pressure perturbation gradient due to the faster, stronger outflow boundary, and the latter is mainly a result of stronger cold fronts and a better alignment of storm-relative inflow with the horizontal vorticity vector. We emphasize that our conclusions only represent one possibility of how urbanization would affect tornado potential, and a more systematic examination is needed to achieve a more general conclusion.

54 ENVIRONMENTAL SCIENCES↗

Shear-aligned large-area organic semiconductor crystals through extended π–π interaction

Small molecule-based organic semiconductors are of broad interest in organic field-effect transistors (OFETs) due to their potential for high crystallinity and electrical performance. The 2D molecule, TIPS-peri-pentacenopentacene (TIPS-PPP), which is the vertical extension of the 1D TIPS-pentacene (TIPS-PEN) molecule, offers a lower bandgap, higher aromaticity, and an enhanced π–π interaction with neighboring molecules in the solid state when compared to TIPS-PEN. However, an in-depth understanding of the relationship between the molecule structure, solid-state molecular packing, and the electronic properties has not been reported due to poor control over the TIPS-PPP crystallite size. In this work, we successfully engineered highly oriented large-area TIPS-PPP crystals through the solution shear coating technique. Additionally, compared with narrow ribbon-like TIPS-PEN crystals, TIPS-PPP crystals can grow centimeters long and over 500 μm wide. TIPS-PPP molecules are less susceptible to forming metastable polymorphs than TIPS-PEN molecules upon fast evaporation. The crystal structure of TIPS-PPP is also thermally stable at 250 °C. Notably, the anisotropic charge carrier mobility of TIPS-PPP crystals is resolved through fabricating bottom-gate top-contact devices, with a hole mobility of 3.1 cm 2 V -1 s -1 along the preferred packing direction. Further device optimization using top-gate bottom-contact devices improved the mobility up to 6.5 cm 2 V -1 s -1 , which is among the highest for pentacene-derivative-based organic semiconductors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Updraft and Downdraft Core Size and Intensity as Revealed by Radar Wind Profilers: MCS Observations and Idealized Model Comparisons

This study explores the updraft and downdraft properties of mature stage mesoscale convective systems (MCSs) in terms of draft core width, shape, intensity, and mass flux characteristics. The observations use extended radar wind profiler (RWP) and surveillance radar datasets from the U.S. Department of Energy Atmospheric Radiation Measurement program for midlatitude (Oklahoma, USA) and tropical (Amazon, Brazil) sites. MCS drafts behave qualitatively similar to previous aircraft and RWP cloud summaries. The Oklahoma MCSs indicate larger and more intense convective up- and downdraft cores, and greater mass flux than Amazon MCS counterparts. However, similar size-intensity relationships and draft vertical profile behaviors are observed for both regions. Additional similarities include weak positive correlations between core intensity and core width (correlation coefficient r ~ 0.5), and increases in draft intensity with altitude. A model-observational intercomparison for draft properties (core width, intensity, mass flux) is also performed to illustrate the potential usefulness of statistical observed draft characterizations. Idealized simulations with the Weather Research and Forecasting model aligned with midlatitude MCS conditions are performed at model grid spacings (?x) that range from 4 km to 250 m. It is shown that the simulations performed at ?x = 250 m at similar mature MCS lifecycle stages are those that exhibit draft intensity, width, mass flux, and shape parameter performances best matching with observed properties.

radar, arm, wind profiler, goamazon↗

Highly Efficient Layer-by-Layer Processed Quaternary Organic Solar Cells with Improved Charge Transport and Reduced Energy Loss

We report how to improve charge transport properties and reduce energy losses are the two main challenges of organic solar cells (OSCs). Herein, a new device fabrication strategy that combines the layer-by-layer (LBL) method and a quaternary active layer is demonstrated to realize highly efficient photovoltaic performance of the OSCs based on PM6:PM7/Y6:O1-2F. The introduction of the second donor, PM7,forms a cascade energy-level alignment with PM6 that facilitates effective charge transfer. The second acceptor, O1-2F, which is poorly miscible with the donors, helps to reduce the miscibility between the donors and acceptors, and thus delivers a more desirable vertical phase separation of the active layer. Furthermore, the alloy acceptor of O1-2F and Y6 can optimize the horizontal and vertical morphology of the active layer, forming an effective charge separation and continuous charge transport channel. As a result, the PM6:PM7/Y6:O1-2F system shows a distinct increase in charge mobility and a reduced nonradiative lossΔVnrof 0.231 V compared to the PM6/Y6 system, achieving a high-power conversion efficiency of18.23%. The results indicate that the quaternary LBL OSCs are promising for future large-scale and industrial manufacture of the OSCs.

14 SOLAR ENERGY↗

Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy

Purpose: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. Methods and Materials: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle{sup 3}, which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. Results: The maximum registration errors in AlignRT were 0.2 Degree-Sign for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1 Degree-Sign , 0.8 Degree-Sign , and 2.2 Degree-Sign in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9 Degree-Sign , 2.4 Degree-Sign , and 4.5 Degree-Sign and 10.1, 11.9, and 6.9 mm at 90% confidence level. Conclusions: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-165: Dosimetric Impact of Liver Rotations in Stereotactic Body Radiation Therapy

Purpose: Often in liver stereotactic body radiotherapy a single fiducial is implanted near the tumor for image-guided treatment delivery. In such cases, rotational corrections are calculated based on the spine. This study quantifies rotational differences between the spine and liver, and investigates the corresponding dosimetric impact. Methods: Seven patients with 3 intrahepatic fiducials and 4DCT scans were identified. The planning CT was separately co-registered with 4 phases of the 4DCT (0%, 50%, 100% inhale and 50% exhale) by 1) rigid registration of the spine, and 2) point-based registration of the 3 fiducials. Rotation vectors were calculated for each registration. Translational differences in fiducial positions between the 2 registrations methods were investigated. Dosimetric impact due to liver rotations and deformations was assessed using critical structures delineated on the 4DCT phases. For dose comparisons, a single fiducial was translationally aligned following spine alignment to represent what is typically done in the clinic. Results: On average, differences between spine and liver rotations during the 0%, 50%, 100% inhale, and 50% exhale phases were 3.23°, 3.27°, 2.26° and 3.11° (pitch), 3.00°, 2.24°, 3.12° and 1.73° (roll), and 1.57°, 1.98°, 2.09° and 1.36° (yaw), respectively. The maximum difference in rotations was 12°, with differences of >3° seen in 14/28 (pitch), 10/28 (roll), and 6/28 (yaw) cases. Average fiducial displacements of 2.73 (craniocaudal), 1.04 (lateral) and 1.82 mm (vertical) were seen. Evaluating percent dose differences for 5 patients at the peaks of the respiratory cycle, the maximum dose to the duodenum, stomach, bowel and esophagus differed on average by 11.4%, 5.3%, 11.2% and 49.1% between the 2 registration methods. Conclusion: Lack of accounting for liver rotation during treatment might Result in clinically significant dose differences to critical structures. Both rotational and translational deviations should be considered in planning margins when using spine alignment for liver treatments.

60 APPLIED LIFE SCIENCES↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion Traps and Packaging for Heterogenous Integration - Chimera

Microfabricated surface ion traps and silicon-based photonics are critical technologies for scaling quantum systems. Current ion trap architectures face scalability and integration challenges due to limitations in optical access, fabrication techniques, and material compatibility. State-of-the-art quantum computers and atomic clocks are investigating monolithic integration, which necessitates custom traps for each ion species and has not overcome the integration hurdles presented by merging these technologies. The Chimera (Ion Traps and Packaging for Heterogeneous Integration) project proposes a novel approach utilizing heterogeneous integration (HI) of ion traps and photonic circuits. This separation of components allows for flexibility in ion trap design and reduces fabrication compromises. The Chimera project specifically designed an ion trap to interface vertically with a separately fabricated waveguide chip and demonstrates the first steps to integrating them at the packaging level. The ion trap features a large area of removed silicon, allowing the photonics chip outputs closer to the ion trap, improving alignment and packaging processes. The alignment must be accurate to < 1 µm to ensure that the light from the waveguide can overlap with the trapping region. This fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. By combining separate chips, we demonstrate a new path for scaling trapped ion technology that is less reliant on monolithic integration. We successfully fabricated a trap with a large area of oxide removed, resulting in a region thinned to about 40 µm, a key milestone toward successful integration.

42 ENGINEERING↗

Field Quality Study of the LARP Nb3Sn 3.7m-Long Quadrupole Models of LQ Series

After the successful test of the first long Nb{sub 3}Sn quadrupole magnet (LQS01), the US LHC Accelerator Research Program (LARP) has assembled and tested a new 3.7 m-long Nb{sub 3}Sn quadrupole (LQS02). This magnet has four new coils made of the same conductor as LQS01 coils, and it is using the same support structure. LQS02 was tested at the Fermilab Vertical Magnet Test Facility with the main goal to confirm that the long models can achieve field gradient above 200 T/m, LARP target for 90-mm aperture, as well as to measure the field quality. These long models lack some alignment features and it is important to study the field harmonics. Previous field quality measurements of LQS01 showed higher than expected differences between measured and calculated harmonics compared to the short models (TQS) assembled in a similar structure. These differences could be explained by the use of two different impregnation fixtures during coil fabrication. In this paper, we present a comparison of the field quality measurements between LQS01 and LQS02 as well as a comparison with the short TQS models. If the result supports the coil fabrication hypothesis, another LQS assembly with all coils fabricated in the same fixture will be produced for understanding the cause of the discrepancy between short and long models.

43 PARTICLE ACCELERATORS↗

Enclosed, off-axis solar concentrator

A solar concentrator including a housing having receiving wall, a reflecting wall and at least two end walls, the receiving, reflecting and end walls defining a three-dimensional volume having an inlet, wherein a vertical axis of the housing is generally perpendicular to the inlet, a receiver mounted on the receiving wall of the housing, the receiver including at least one photovoltaic cell, wherein a vertical axis of the receiver is disposed at a non-zero angle relative to the vertical axis of the housing, at least one clip disposed on the reflecting wall an optical element received within the three-dimensional volume, the optical element including at least one tab, the tab being engaged by the clip to align the optical element with the receiver, and a window received over the inlet to enclose the housing.

47 OTHER INSTRUMENTATION↗

TOPDAQ Acquisition Utility Beta version 1.0

This TOPDAQ Acquisition Utility uses 5 digital cameras mounted on a vertical pole, maintained in a vertical position using sensors and actuators, to take photographs of an RP-2 or RP-3 module, one camera for each row (4) and one in the center for driving, when the module is at 0 degrees, or facing the eastern horizon. These photographs and other data collected at the same time the pictures are taken are analyzed by the TOPAAP Analysis Utility. The TOPCAT implemented by the TOPDAQ Acquisition Utility and TOPAAP Analysis Utility programs optimizes the alignment of each RP in a module on a parabolic trough solar collector array (SCA) to maximize the amount of solar energy intercepted by the solar receiver. The camera fixture and related hardware are mounted on a pickup truck and driven between rows in a parabolic trough solar power plant. An ultrasonic distance meter is used to maintain the correct distance between the cameras and the RP module. Along with the two leveling actuators, a third actuator is used to maintain a proper relative vertical position between the cameras and the RP module. The TOPDAQ Acquisition Utility facilitates file management by keeping track of which RP module data is being taken and also controls the exposure levels for each camera to maintain a high contract ratio in the photograph even as the available daylight changes throughout the day. The theoretical TOPCAT hardware and software support the current industry standard RP-2 and RP-3 module geometries.

MOreno, Mario↗

Tunable and laser-reconfigurable 2D heterocrystals obtained by epitaxial stacking of crystallographically incommensurate Bi 2 Se 3 and MoS 2 atomic layers

Vertical stacking is widely viewed as a promising approach for designing advanced functionalities using two-dimensional (2D) materials. Combining crystallographically commensurate materials in these 2D stacks has been shown to result in rich new electronic structure, magnetotransport, and optical properties. In this context, vertical stacks of crystallographically incommensurate 2D materials with well-defined crystallographic order are a counterintuitive concept and, hence, fundamentally intriguing. We show that crystallographically dissimilar and incommensurate atomically thin MoS 2 and Bi 2 Se 3 layers can form rotationally aligned stacks with long-range crystallographic order. Our first-principles theoretical modeling predicts heterocrystal electronic band structures, which are quite distinct from those of the parent crystals, characterized with an indirect bandgap. Experiments reveal striking optical changes when Bi 2 Se 3 is stacked layer by layer on monolayer MoS 2 , including 100% photoluminescence (PL) suppression, tunable transmittance edge (1.1→0.75 eV), suppressed Raman, and wide-band evolution of spectral transmittance. Disrupting the interface using a focused laser results in a marked the reversal of PL, Raman, and transmittance, demonstrating for the first time that in situ manipulation of interfaces can enable “reconfigurable” 2D materials. We demonstrate submicrometer resolution, “laser-drawing” and “bit-writing,” and novel laser-induced broadband light emission in these heterocrystal sheets.

36 MATERIALS SCIENCE↗

Structurally induced large changes of the energy level alignment in CuPc on Cu ( 110 ) - ( 2 × 1 ) O

While it is becoming apparent that organic semiconductor/metal interfaces may exhibit a variety of different structural phases, it is at present unclear to what extent these different thin-film structures determine the interfacial electronic structure. Here, we observe large changes in the interfacial electronic structure for the case of copper(II) phthalocyanine (CuPc) on Cu(110)–(2×1)O. This striking evolution of the interfacial electronic structure occurs beyond the first monolayer of CuPc and is particularly evident in the frontier orbital region. Using scanning tunneling microscopy in conjunction with photoemission spectroscopy, we characterize ultrathin films of CuPc grown on oxygen reconstructed Cu(110). We propose that the observed unique changes to the electronic structure result from an abrupt transition in film structure between the first and second layers: An interface layer of ordered, face-on molecules templates a largely vertical, edge-on orientation of molecules in the subsequent layer. The quadrupole moment of the molecule accounts for the sizable and unusual change in ionization energy between molecules in the two layers. Lastly, our results demonstrate that the precise structure of the organic semiconductor film exerts an important role in determining the interfacial electronic structure that must be considered and may be harnessed for tailoring energy level alignment at such interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Slip transmission of high angle grain boundaries in body-centered cubic metals: Micropillar compression of pure Ta single and bi-crystals

In this study, we seek to probe and understand the mechanical behavior of grain boundaries in pure Ta as a model bcc material using micropillar compression experiments. Three high angle grain boundaries are chosen with varying crystal orientations. Multiple bi-crystal pillars are prepared containing a single, nearly vertical grain boundary in the approximate center of the pillar and compared against their single crystalline pillar counterparts. The main phenomenon of interest was slip transmission or strain transfer in the bi-crystals which was considered to occur when slip traces aligned across the grain boundary. This occurred in two of the three bi-crystals.