Atomic-scale mixing between MgO and H2O in the deep interiors of water-rich planets
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.
Direct coupled photovoltaic (PV)-electrolysis is a promising approach for low-cost hydrogen production, avoiding the need for separate electricity generation. Without solar concentration, the operating current densities of a PV-electrolyzer are small, and low capital costs are needed to reach hydrogen production cost targets (<$2/kg). Anion-exchange membrane (AEM) electrolyzers could be well-suited for this application due to their ability to use platinum group metal (PGM)-free catalysts and operate without supporting electrolytes, but a water-fed PV-AEM system has not yet been demonstrated. In this work, the performance of two AEM electrolyzer designs under pure-water, low-temperature, and diurnal-cycling conditions was evaluated. A simple PV-electrolyzer system design with direct electric coupling to a commercial 84 cm2 Si mini module and passive heating and water flow to the electrolyzer was used for on-sun testing in October 2025. The best-performing PV-AEM system achieved an average solar-to-hydrogen (STH) efficiency of 6.6% and a production rate of 15 mg/kWh/m2 of solar irradiance over 11 days. Minimal electrolyzer corrosion was observed, with no loss in efficiency over the diurnal cycles. While highlighting areas for improved electrolyzer and system design, this work is a proof of concept for distributed hydrogen production using inexpensive and abundant materials.
A simultaneous deployment of Doppler, temperature, and water-vapor lidars is able to provide profiles of molecular destruction rates and turbulent kinetic energy (TKE) dissipation in the convective boundary layer (CBL). Horizontal wind profiles and profiles of vertical wind, temperature, and moisture fluctuations are combined, and transversal temporal autocovariance functions (ACFs) are determined for deriving the dissipation and molecular destruction rates. These are fundamental loss terms in the TKE as well as the potential temperature and mixing ratio variance equations. These ACFs are fitted to their theoretical shapes and coefficients in the inertial subrange. Error bars are estimated by a propagation of noise errors. Sophisticated analyses of the ACFs are performed in order to choose the correct range of lags of the fits for fitting their theoretical shapes in the inertial subrange as well as for minimizing systematic errors due to temporal and spatial averaging and micro- and mesoscale circulations. We demonstrate that we achieve very consistent results of the derived profiles of turbulent variables regardless of whether 1 or 10 s time resolutions are used. We also show that the temporal and spatial length scales of the fluctuations in vertical wind, moisture, and potential temperature are similar with a spatial integral scale of ≈160 m at least in the mixed layer (ML). The profiles of the molecular destruction rates show a maximum in the interfacial layer (IL) and reach values of ϵ m ≃ 7 x 10 -4 g 2 kg −2 s −1 for mixing ratio and ϵ θ ≃ 1.6 x 10 -3 K 2 s −1 for potential temperature. In contrast, the maximum of the TKE dissipation is reached in the ML and amounts to ≃ 10 -2 m 2 s −3 . We also demonstrate that the vertical wind ACF coefficient k w ∝ $\overline{w'^{2}}$ and the TKE dissipation ϵ ∝ ($\overline{w'^{2}}$) 3/2 . For the molecular destruction rates, we show that ϵ m ∝ $\overline{m'^{2}}$ ($\overline{w'^{2}}$) 1/2 and ϵ θ ∝ $\overline{θ'^{2}}$ ($\overline{w'^{2}}$) 1/2 . These equations can be used for parameterizations of ϵ, ϵ m , and ϵ θ . All noise error bars are derived by error propagation and are small enough to compare the results with previous observations and large-eddy simulations. The results agree well with previous observations but show more detailed structures in the IL. Consequently, the synergy resulting from this new combination of active remote sensors enables the profiling of turbulent variables such as integral scales, variances, TKE dissipation, and the molecular destruction rates as well as deriving relationships between them. The results can be used for the parameterization of turbulent variables, TKE budget analyses, and the verification of large-eddy simulations.
We present absorption spectra of thin, free-flowing liquid sheets in the vacuum ultraviolet energy range using a gas-squeezed liquid jet. Compared to liquid flow cells, operation without transmission windows eliminates restrictions on the energy range. The temperature of the water sheet is estimated at 0 ± 3 °C, at the verge of the supercooled regime. By adjusting flow conditions in situ, we recorded absorption spectra at water sheet thicknesses ranging from 20 to 50 nm. We show that the absorption spectra of thin jets contain significant contributions from interference effects that need to be deconvoluted from spectral contributions due to the electronic structure. We employ a Fresnel propagation model to model the spectral changes and understand the impact of thickness variations and thin film interference. This opens the door for the investigation of solvation, interface, and similar effects by recording valence band spectra.
This report describes the pre-irradiation characterization and successful assembly of a High Flux Isotope Reactor (HFIR) irradiation experiment designed to assess radiation-induced lateral bowing of silicon carbide fiber–reinforced, silicon carbide matrix composite (SiC/SiC) components under a radial fast neutron flux gradient at representative light-water reactor (LWR) temperatures of approximately 300 °C. The over-arching goal of this work is to validate thermomechanical models of SiC/SiC composite fuel assembly distortion used to predict the extent of lateral bowing and dose at which bowing reaches a maximum value. Ultimately, these models are used to ensure that fuel assembly distortion does not block coolant channels, interfere with control rod/blade movements, and/or impact local reactivity. The experiment contains six cladding tube specimens that are approximately 558.5 mm long with representative pressurized water reactor (PWR) outer and inner diameters of 9.5 mm and 7.5 mm, respectively. The specimens were thoroughly characterized prior to irradiation using traditional dimensional inspection and surface profilometry so that these measurements can later be compared with similar measurements that will be made post-irradiation to determine radiation-induced deformations. Furthermore, fine engraving markers were inscribed along the outer surfaces of the specimen and mapped using analytic photography and a three-dimensional stage. This technique allowed for accurate measurements of the marker spacings, which can be compared with similar measurements that will be made post-irradiation to provide local radiation-induced strain mapping. A light curtain optical micrometer was also employed to measure the pre-irradiation bowing of each specimen. The experiment was successfully assembled and inserted into position VXF-19 for HFIR cycle 516, which began May 12, 2026. The experiment will be removed after cycle 519, which is currently scheduled to end in December 2026.
Climate change and anthropogenic activities can both influence stream temperature, which is a critical indicator of thermoelectric power generation potential. Previous studies emphasized the vulnerability of power-generation systems to climate warming (ref 1, 2). Despite the fact that two-thirds of the global rivers are regulated by dams (ref 3), the relative impacts of water management and climate change on stream temperature and thermoelectric production have not yet been evaluated. Using an integrated modeling system applied to the conterminous United States, simulations confirm the dominant role of climate change in shaping the future trends of stream temperature. However, water management, reservoir regulation in particular, can mitigate the stream temperature warming and reduce the frequency and magnitude of extreme high stream temperatures through redistribution of the seasonal streamflow. Moreover, water management can alleviate the loss of power plant usable capacity from climate change to the level of reduced warming from emission mitigation. By regulating the flow and temperature regimes, water management is a promising adaptation measure to alleviate climate change induced effects in the water-energy nexus.
This dataset contains collected dissolved oxygen (DO) and temperature measurements of the air, surface water, and underlying soil of a wetland at Old Woman Creek Estuarine Research Reserve in Huron, OH. Dissolved oxygen and temperature measurements were made in the first few centimeters of wetland sediment to assess how oxygen profiles changed over time with hydrological events. Measurements taken outside of the sediment were taken as comparison. Measurements were taken by hand with a PreSens Fibox 4 transmitter, paired with an oxygen dipping probe and temperature sensor, at each field outing. Measurements were taken approximately every 2 weeks around 10 AM EST. The PreSens_DO_Temp_Datafile.csv contains the recorded measurements, and the PreSens_InstallationMethods.csv describes the deployment of the sensor.
This report documents the design of a High Flux Isotope Reactor (HFIR) irradiation experiment intended to evaluate irradiation effects on the hermeticity of silicon carbide (SiC) end plug specimens under a radial fast neutron flux gradient at representative light-water reactor (LWR) temperatures of approximately 300 °C. The overarching goal of this work is to statistically evaluate SiC end plug hermeticity and mechanical properties following irradiation using the high-throughput irradiation capability discussed here. Each specimen consists of a short section of SiC fiber–reinforced SiC (SiC/SiC) tube with a single monolithic SiC end plug joined to one end. The experiment allows up to 66 specimens to be irradiated in six different stacks within a dry, sealed irradiation capsule derived from the previously developed high-temperature SiC/SiC cladding bowing experiment. The neutronics basis, thermal analysis, and HFIR readiness of the experiment are discussed in this report for two possible design cases. The first design case is based on existing approval documentation and components that are on hand and approved for use, so the experiment insertion would require only specimen receipt, specimen pre-irradiation characterization, experiment assembly, and final fabrication package approval. The second design case provides improved thermal robustness and the preferred end plug geometry but requires fabrication of a modified holder and revisions to the HFIR approval documentation, in addition to the other activities required for the first design case, before insertion.
The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.
The Hunga Tonga–Hunga Ha'apai Model–Observation Comparison (HTHH–MOC) project aims to comprehensively investigate the evolution of volcanic water vapor and sulfur emissions and their subsequent atmospheric impacts and underlying response mechanisms using state-of-the-art global climate models. This study evaluates multi-model ensemble simulations participating in the HTHH–MOC free-run experiment with climate projections for 10 years (2022–2032). Model results are evaluated against satellite observations to assess their ability to reproduce the observed evolution of stratospheric water vapor, aerosols, temperature, and ozone from 2022 to 2024. The participating models accurately capture the observed distribution patterns and associated upper atmospheric responses, providing confidence for their future projections. Model simulations suggest that the Hunga eruption-induced stratospheric water vapor anomaly lasts 4–7 years, with a water vapor e-folding time of 31–43 months. This prolonged water vapor perturbation leads to significant stratospheric and mesospheric cooling, resulting in significant ozone loss in the upper stratosphere and lower mesosphere for 7–10 years. Comparisons between simulations with both SO 2 and H 2 O emissions and those with H 2 O-only emissions indicate that the pronounced dipole response with upper-stratospheric cooling and lower-stratospheric warming is driven by the combined effects of SO 2 and H 2 O injections. These results highlight the prolonged atmospheric impacts of the Hunga eruption and the potential critical role of stratospheric water vapor in modulating long-term atmospheric chemistry and dynamics.
ABSTRACT Under the United States Clean Water Act, states are required to periodically assess state waters to determine compliance with water quality criteria (including temperature) and then to develop total maximum daily loads (TMDLs) for impaired waters as necessary to bring them into compliance. We compared the performance of mechanistic stream temperature models (HeatSource, QUAL2K, and QUAL2Kw) applied to the mainstem of three TMDL watersheds (Middle Fork John Day, OR; Wind River, WA; South Fork Nooksack, WA) with that of spatial stream network (SSN) models applied to the full watersheds and used these to evaluate the potential effectiveness of restoration strategies. SSN models performed well with slightly lesser accuracy (RMSE = 0.47–0.87) for mainstem predictions than mechanistic models (RMSE = 0.4) but provided additional benefits to inform management, including information on spatial and temporal heterogeneity of restoration effectiveness throughout the watershed. Of the four scenarios considered (restoration of riparian zones to potential natural vegetation, channel narrowing, increasing flow by restricting irrigation withdrawals, and combined applications), riparian zone restoration was consistently the most effective in reducing temperatures at the outlet, mainstem, and throughout the watersheds. Predicted restoration effectiveness for thermal regimes varied significantly both within and among watersheds. A focus on water quality criteria exceedance only at the watershed outlet or along the mainstem reach can obscure knowledge of restoration potential for fish habitat in tributaries and headwaters, potential for creation of thermal refuge areas along the mainstem critical for maintaining migration corridors, and thermal regime heterogeneity across space and time.
Hydrogen is being considered integral to the future energy landscape but there is limited mechanistic understanding and a lack of predictive models to describe the combined effects of alloy and gas composition, temperature, thermal cycling and water vapor contents on the oxidation behavior of high-temperature materials. Experimental evaluations were combined with coupled thermodynamic-kinetic modeling to investigate the oxidation behavior of five representative Ni-based superalloys in two water vapor contents (10%, 60% H 2 O) under thermal cycling (1-h, 100-h cyles) conditions at 800°C and 1000°C. The alloy with the highest Ti content demonstrated the poorest cyclic oxidation behavior while the alloy with highest Cr and Al contents was expected to continue to support protective formation of a compact Al 2 O 3 scale. Finally, accelerated degradation of the chromia-forming alloys was observed in the higher water vapor content but the impact on transient oxidation of the alumina-forming alloys needs further investigations.
Climate change influences many aspects of the electric grid, but prior work and industry practices often ignore the potential effects of changing climate, or they only consider a single effect or individual effects in isolation. Challenges vary with each grid and include adapting to long-term trends such as changing temperature and precipitation or shorter-term events such as drought or storms that could increase in frequency or intensity. Here we present a multi-model framework designed to analyze the effects of long and short-term climate impacts in combination. This framework couples capacity expansion and production cost models with hydrologic models and future climate scenario data to analyze alternative climate and energy futures at high spatial, temporal, and process resolutions. Furthermore, we constructed and evaluated the results of a suite of simulated scenarios exploring climate impacts on capacity investment and stress-tested the resulting future infrastructures using hourly dispatch modeling under alternative drought and load conditions. We demonstrate the approach through a case study of the U.S. Western Interconnection, where climate impacts depend on interactions between temperature-induced load, water availability for hydropower, technology competitiveness, and demand flexibility. Changes in 2038 generating capacity range from -8.5-16.6 GW, and changes in 2038 transmission capacity range from -1-2 GW. Capacity increases are driven by higher load from higher temperatures, while capacity reductions can be achieved in scenarios with higher future hydropower availability and increased demand flexibility. Scenarios requiring additional capacity cost an additional $\$5$-$\$17$ billion (discounted) from 2018 to 2038; however, scenarios with capacity reductions cost $\$1$-$\$18$ billion less. Stress tests on four 2038 infrastructures demonstrated that the identified systems were able to serve at least 99.999% of load and 99.96% of reserves. However, drought and unexpected high-load conditions can result in reduced capacity to respond to contingency events we did not model. Although these results are system and scenario specific, they highlight the importance of considering multiple climate change impacts simultaneously in long-term planning efforts and demonstrate a multi-model, multiscale approach that can be flexibly applied to any system and set of climate change concerns.
Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.
Abstract Organic peat soils occupy relatively little of the global land surface area but store vast amounts of soil carbon in northern latitudes where climate is warming at a rapid pace. Warming may result in strong positive feedbacks of carbon loss and global climate change driven by microbial processes if warming alters the balance between primary productivity and decomposition. To elucidate effects of warming on the microbial communities mediating peat carbon dynamics, we explored the abundance of broad microbial groups and their source of carbon (i.e. old carbon versus more recently fixed photosynthate) using microbial lipid analysis (δ 13 C PLFA) of peat samples under ambient temperatures and before/after initiation of experimental peat warming (+ 2.25, + 4.5, + 6.75, and + 9 °C). This analysis occurred over a profile to 2 m depth in an undrained, ombrotrophic peat bog in northern Minnesota. We found that the total microbial biomass and individual indicator lipid abundances were stratified by depth and strongly correlated to temperature under ambient conditions. However, under experimental warming, statistically significant effects of temperature on the microbial community were sporadic and inconsistent. For example, 3 months after experimental warming the relative abundance of Gram-negative bacterial indicators across depth combined and > 50 cm depth and Gram-positive bacterial indicators at 20–50 cm depth showed significant positive relationships to temperature. At that same timepoint, however, the relative abundance of Actinobacterial indicators across depth showed a significant negative relationship to temperature. After 10 months of experimental warming, the relative abundance of fungal biomarkers was positively related to temperature in all depths combined, and the absolute abundance of anaerobic bacteria declined with increasing temperature in the 20–50 cm depth interval. The lack of observed response in the broader microbial community may suggest that at least initially, microbial community structure with peat depth in these peatlands is driven more by bulk density and soil water content than temperature. Alternatively, the lack of broad microbial community response may simply represent a lag period, with more change to come in the future. The long-term trajectory of microbial response to warming in this ecosystem then could either be direct, after this initial lag time, or indirect through other physical or biogeochemical changes in the peat profile. These initial results provide an important baseline against which to measure long-term microbial community and carbon-cycling responses to warming and elevated CO 2 .
Explore the source record for details and available documents.
Not Available