Search NASA⌕ Search

SEARCH · Search NASA

Results for “weights”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Correlation between tobacco control policies and preterm births and low birth weight in Europe

Highlights: • We describe the association between TCS and preterm births at ecological level. • We describe the association between TCS and low weight births at ecological level. • There was a negative correlation between TCS and the prevalence of preterm births. • Our data support greater implementation of smoke-free policies. To assess the correlation between tobacco control policies— particularly smoking bans in work and public places—and the prevalence of preterm births and low birth weight in the European countries.

54 ENVIRONMENTAL SCIENCES↗

Environmental risk factors associated with low birth weight: The case study of the Haifa Bay Area in Israel

Highlights: • Environmental factors affecting low birth weight (LBW) rate are investigated. • Analysis is conducted by alternative techniques of geo-statistical analysis. • Proximity to petrochemical industries is found to increase LBW rate. • Seashore proximity and elevation above the sea level reduce the LBW rate. • We attribute the latter to climate-moderating effect of elevated seashore locations. Low birth weight (LBW) is known to be associated with infant mortality and postnatal health complications. Previous studies revealed strong relationships between LBW rate and several socio-demographic factors, including ethnicity, maternal age, and family income. However, studies of association between LBW rate and environmental risk factors remain infrequent.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Mesorectal Lymph Nodes in Rectal Cancer Before and After Neoadjuvant Chemoradiation Using Thin-Section T2-Weighted Magnetic Resonance Imaging

Purpose: To apply thin-section T2-weighted magnetic resoance imaging (MRI) to evaluate the number, size, distribution, and morphology of benign and malignant mesorectal lymph nodes before and after chemoradiation treatment compared with histopathologic findings. Methods and Materials: Twenty-five patients with poor-risk adenocarcinoma of the rectum treated with neoadjuvant chemoradiation were evaluated prospectively. Thin-section T2-weighted MR images obtained before and after chemoradiation treatment were independently reviewed in consensus by 2 expert radiologists to determine the tumor stage, nodal size, nodal distribution, and nodal stage. Total mesorectal excision surgery after chemoradiation allowed MR nodal stage to be compared with histopathology using {kappa} statistics. Nodal downstaging was compared using the Chi-square test. Results: Before chemoradiation, 152 mesorectal nodes were visible (mean, 6.2 mm; 100 benign, 52 malignant) and 4 of 52 malignant nodes were in contact with the mesorectal fascia. The nodal staging was 7/25 N0, 10/25 N1, and 7/25 N2. After chemoradiation, only 29 nodes (mean, 4.1 mm; 24 benign, 5 malignant) were visible, and none were in contact with the mesorectal fascia. Nodal downstaging was observed: 20/25 N0 and 5/25 N1 (p < 0.01, Chi-square test). There was good agreement between MRI and pathologic T-staging ({kappa} = 0.64) and N-staging ({kappa} = 0.65) after chemoradiation. Conclusions: Neoadjuvant chemoradiation treatment resulted in a decrease in size and number of malignant- and benign-appearing mesorectal nodes on MRI. Nodal downstaging and nodal regression from the mesorectal fascia were observed after treatment. MRI is a useful tool for assessing nodal response to neoadjuvant treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion-Weighted Magnetic Resonance Imaging to Evaluate Major Salivary Gland Function Before and After Radiotherapy

Purpose: To evaluate diffusion-weighted (DW)-MRI as a noninvasive tool to investigate major salivary gland function before and after radiotherapy (RT) for head and neck cancer (HNC). Methods and Materials: DW-MRI was performed in 8 HNC patients before and after parotid-sparing RT (mean dose to the contralateral parotid gland <26 Gy). A DW sequence was performed once at rest and then repeated continuously during salivary stimulation. Apparent diffusion coefficient (ADC) maps for both parotid and submandibular glands were calculated. Findings were compared with salivary gland scintigraphy. Results: Before RT, the mean ADC value at rest was significantly lower in the parotid than in the submandibular glands. During the first 5 min of stimulation, the ADC value of the salivary glands showed a decrease, followed by a steady increase until a peak ADC, significantly higher than the baseline value, was reached after a median of 17 min. The baseline ADC value at rest was significantly higher after RT than before RT in the nonspared salivary glands but not in the spared parotid glands. In the contralateral parotid glands, the same response was seen as before RT. This pattern was completely lost in the nonspared glands. These results corresponded with remaining or loss of salivary function, respectively, as confirmed by salivary gland scintigraphy. Conclusions: Diffusion-weighted-MRI allows noninvasive evaluation of functional changes in the major salivary glands after RT and is a promising tool for investigating radiation-induced xerostomia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Diffusion-Weighted Imaging in the Localization of Prostate Cancer

Purpose: Advances in high-precision radiation therapy techniques for patients with prostate cancer permit selective escalation of the radiation dose delivered to the dominant intraprostatic lesion and improve the therapeutic ratio. We evaluated the value of diffusion-weighted imaging (DWI) for dominant intraprostatic lesion assessment. Methods and Materials: The study population consisted of 23 patients with early prostate cancer. Before undergoing total prostatectomy, they were evaluated by means of magnetic resonance imaging, including DWI. T2-weighted imaging (T2WI) with and without DWI were retrospectively assessed by six independent observers. Imaging findings were compared with pathologic results from whole prostate specimens on a lesion-by-lesion basis. Results: Pathologic study identified 43 lesions in 23 patients. On magnetic resonance imaging, the six observers correctly identified 11-22 of 43 lesions (sensitivity, 26-51%) on T2WI alone and 20-31 (sensitivity, 47-72%) on T2WI plus DWI. Positive predictive values were 42-73% on T2WI alone and 58-80% on T2WI plus DWI. For all observers, detection was higher on combined T2WI and DWI than on T2WI alone. Conclusion: Because the addition of DWI to T2WI improves the detectability of prostate cancer, DWI may offer a promising new approach for radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of [{sup 11}C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions

Purpose: The purpose of this study was to compare the accuracy of [{sup 11}C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified on prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV{sub 60}) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV{sub 60}; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypercellularity Components of Glioblastoma Identified by High b-Value Diffusion-Weighted Imaging

Purpose: Use of conventional magnetic resonance imaging (MRI) for target definition may expose glioblastomas (GB) to inadequate radiation dose coverage of the nonenhanced hypercellular subvolume. This study aimed to develop a technique to identify the hypercellular components of GB by using high b-value diffusion-weighted imaging (DWI) and to investigate its relationship with the prescribed 95% isodose volume (PDV) and progression-free survival (PFS). Methods and Materials: Twenty-one patients with GB underwent chemoradiation therapy post-resection and biopsy. Radiation therapy (RT) treatment planning was based upon conventional MRI. Pre-RT DWIs were acquired in 3 orthogonal directions with b-values of 0, 1000, and 3000 s/mm{sup 2}. Hypercellularity volume (HCV) was defined on the high b-value (3000 s/mm{sup 2}) DWI by a threshold method. Nonenhanced signified regions not covered by the Gd-enhanced gross tumor volume (GTV-Gd) on T1-weighted images. The PDV was used to evaluate spatial coverage of the HCV by the dose plan. Association between HCV and PFS or other clinical covariates were assessed using univariate proportional hazards regression models. Results: HCVs and nonenhanced HCVs varied from 0.58 to 67 cm{sup 3} (median: 9.8 cm{sup 3}) and 0.15 to 60 cm{sup 3} (median: 2.5 cm{sup 3}), respectively. Fourteen patients had incomplete dose coverage of the HCV, 6 of whom had >1 cm{sup 3} HCV missed by the 95% PDV (range: 1.01-25.4 cm{sup 3}). Of the 15 patients who progressed, 5 progressed earlier, within 6 months post-RT, and 10 patients afterward. Pre-RT HCVs within recurrent GTVs-Gd were 78% (range: 65%-89%) for the 5 earliest progressions but lower, 53% (range: 0%-85%), for the later progressions. HCV and nonenhanced HCV were significant negative prognostic indicators for PFS (P<.002 and P<.01, respectively). The hypercellularity subvolume not covered by the 95% PDV was a significant negative predictor for PFS (P<.05). Conclusions: High b-value DWI identifies the hypercellular components of GB and could aid in RT target volume definition. Future studies will allow us to investigate the role of high b-value DWI in identifying radiation boost volumes and diagnosing progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of stochastic weighted algorithms to a multidimensional silica particle model

Highlights: •Stochastic weighted algorithms (SWAs) are developed for a detailed silica model. •An implementation of SWAs with the transition kernel is presented. •The SWAs’ solutions converge to the direct simulation algorithm’s (DSA) solution. •The efficiency of SWAs is evaluated for this multidimensional particle model. •It is shown that SWAs can be used for coagulation problems in industrial systems. -- Abstract: This paper presents a detailed study of the numerical behaviour of stochastic weighted algorithms (SWAs) using the transition regime coagulation kernel and a multidimensional silica particle model. The implementation in the SWAs of the transition regime coagulation kernel and associated majorant rates is described. The silica particle model of Shekar et al. [S. Shekar, A.J. Smith, W.J. Menz, M. Sander, M. Kraft, A multidimensional population balance model to describe the aerosol synthesis of silica nanoparticles, Journal of Aerosol Science 44 (2012) 83–98] was used in conjunction with this coagulation kernel to study the convergence properties of SWAs with a multidimensional particle model. High precision solutions were calculated with two SWAs and also with the established direct simulation algorithm. These solutions, which were generated using large number of computational particles, showed close agreement. It was thus demonstrated that SWAs can be successfully used with complex coagulation kernels and high dimensional particle models to simulate real-world systems.

97 MATHEMATICS AND COMPUTING↗

A pairwise nuclear fusion algorithm for weighted particle-in-cell plasma simulations

In this work, a pairwise nuclear fusion algorithm for arbitrarily weighted macroparticles in a particle-in-cell simulation is described. The method is benchmarked in situations with like-particles, D(d,n) 3 He, unlike-particles, D(t,n) 4 He, thermonuclear plasmas, beam-target fusion, and for large difference in macroparticle weights. Studies of the required number of macroparticles in thermonuclear plasmas show that 100–1000 macroparticles are required to achieve repeatability of yields around 10%, likewise 10 4 –10 5 for 1%, depending on the fusion interaction and ion temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A weighted Shifted Boundary Method for free surface flow problems

The Shifted Boundary Method (SBM) belongs to the class of unfitted (or immersed, or embedded) finite element methods and was recently introduced for the Poisson, linear advection/diffusion, Stokes, Navier-Stokes, acoustics, and shallow-water equations. By reformulating the original boundary value problem over a surrogate (approximate) computational domain, the SBM avoids integration over cut cells and the associated problematic issues regarding numerical stability and matrix conditioning. Accuracy is maintained by modifying the original boundary conditions using Taylor expansions. Hence the name of the method, that shifts the location and values of the boundary conditions. In this article, we extend the SBM to the simulation of incompressible Navier-Stokes flows with moving free-surfaces, by appropriately weighting its variational form with the elemental volume fraction of active fluid. This approach prevents spurious pressure oscillations in time, which would otherwise be produced if the total active fluid volume were to change abruptly over a time step. In fact, the proposed weighted SBM method induces small mass (i.e., volume) conservation errors, which converge quadratically in the case of piecewise-linear finite element interpolations, as the grid is refined. Finally, we present an extensive set of two- and three-dimensional tests to demonstrate the robustness and accuracy of the method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A weighted shifted boundary method for immersed moving boundary simulations of Stokes' flow

The Shifted Boundary Method (SBM) belongs to the class of unfitted (or immersed, or embedded) finite element methods, and relies on reformulating the original boundary value problem over a surrogate (approximate) computational domain. The surrogate domain is constructed so as to avoid cut cells and the associated problematic implementation and numerical integration issues. Accuracy is maintained by modifying the original boundary conditions using Taylor expansions: hence the name of the method, that shifts the location and values of the boundary conditions. Here, in this article, we extend the SBM to the simulation of incompressible Stokes flow, by appropriately weighting its variational form with the elemental volume fraction of active fluid. This approach allows to drastically reduce spurious pressure oscillations in time, which are produced if the total volume of active fluid were to change abruptly over a time step. The proposed Weighted SBM (W-SBM) exactly preserves states of hydrostatic equilibrium, and induces small mass and momentum conservation errors, which converge as the grid is refined. This is in analogy to cutFEMs and related unfitted approaches, which rely on an affine representation of cut boundaries. We demonstrate the robustness and accuracy of the proposed method with an extensive suite of two-dimensional tests.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Respiratory Triggered Diffusion-Weighted MRI with Three b-Values Compared to ADC Map and Fast Spin Echo Heavily T2W in Differential Diagnosis of Hemangioma from Malignant Liver Lesions

The goal of this study was to evaluate the ability of diffusion-weighted imaging (DWI) with three different b-values compared to apparent diffusion coefficient (ADC) map and fast spin echo heavily T{sub 2} weighted (FSE-HT{sub 2}W) in differential diagnosis of hemangioma from malignant liver lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of silicon-graphite homogeneity as promoted by low molecular weight dispersants

This study explores low molecular weight polymers with the same chemical repeat structure as high molecular weight poly acrylic acid (PAA) and lithium poly acrylic acid (LiPAA) binders which act as a dispersant to improve the silicon-graphite electrode performance. The electrodes which utilize LiPAA as a dispersant perform, on average, the best with respect to the maximum capacity (compared to theoretical), rate performance, and capacity retention with time. These electrodes also have the poorest dispersion of binder, indicating that the poor binder dispersion is essential to electrode performance. In contrast, this study shows that electrodes formulated using PAA had good dispersion and performs the worst in cycling. Finally, this work demonstrates that the binder is not uniformly distributed in the electrode, but rather resides in local regions. Overall, the results indicate these regions accommodate volume expansion during cycling.

25 ENERGY STORAGE↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Multiscale geographically and temporally weighted regression (MGTWR): exploring the spatiotemporal heterogeneity of EV market adoption

As an innovative vehicle technology, electric vehicles are experiencing growing sales and have made significant inroads into the traditional automotive market in the United States and around the world. However, EV adoption rates vary significantly across space and over time, influenced by a complex interplay of socio-economic and infrastructural factors alongside federal and state policies. Here, this paper presents a comprehensive spatial–temporal investigation of EV market adoption within one city in the US, that of Chicago, utilizing Multiscale Geographically and Temporally Weighted Regression (MGTWR) alongside Multiscale Geographically Weighted Regression (MGWR). The aim is to unravel the spatial and temporal dynamics affecting EV adoption and to explore how the influence of various determinants of EV adoption, such as demographic factors and economic conditions, vary spatially. Moreover, by utilizing MGTWR, we provide insights into the evolution of these relationships over time, offering a predictive outlook on future EV market growth. Our findings, with an 86.6% prediction accuracy for EV market adoption, tailored policy measures to support accelerated EV adoption. Methodologically, this work advances MGWR frameworks by integrating temporal dynamics to examine nonstationary processes in spatially disaggregated contexts. These findings offer evidence–based guidance for policymakers, urban planners, and stakeholders in the automotive industry, supporting the transition toward a more sustainable and efficient transportation system.

EV Market Adoption↗

Electrodeposition of Zinc in Aqueous Electrolytes Containing High Molecular Weight Polymers

Strong polarization of the ion distribution in liquid electrolytes subjected to potential differences exceeding the thermal voltage, V T = kT/e, produces a hydrodynamic instability termed electroconvection at ion-selective interfaces. Electroconvection is desirable in some situations (e.g., electrodialysis) because it promotes mixing in a stagnant electrolyte layer, enhancing the ion flux at a fixed potential difference. It is undesirable in others (e.g., electrodeposition of metals) where early experiments show that convective fluid rolls associated with hydrodynamic instability in bounded electrolytes produce preferential metal deposition at localized regions on an electrode. Such localized deposition drives the family of morphological instabilities loosely termed dendritic electrodeposition. We experimentally investigate the effect of ultrahigh molecular weight polymer additives on the onset conditions and physical characteristics of both instabilities. Direct observations of electrodeposit morphology and tracer particle motions used in tandem with indirect electrokinetic measurements reveal that even at moderate concentrations, the polymer additives have a large beneficial effect in extending the range of electric potentials where stable electrodeposition is observed. Additionally, we report that at polymer concentrations above the entanglement threshold, high molecular weight polymers impart elasticity to liquid electrolytes which dampen electroconvective flow at a cation-selective interface but have at most a minimal effect on the bulk ionic conductivity of the liquid.

25 ENERGY STORAGE↗

Ultrahigh Molecular Weight Linear Block Copolymers: Rapid Access by Reversible-Deactivation Radical Polymerization and Self- Assembly into Large Domain Nanostructures

Block copolymer (BCP) derived periodic nanostructures with domain sizes larger than 150 nm present a versatile platform for the fabrication of photonic materials. So far, the access to such materials has been limited to highly synthetically involved protocols. Herein, we report a simple, “user-friendly” method for the preparation of ultrahigh molecular weight linear poly(solketal methacrylate-b-styrene) block copolymers by a combination of Cu-wire-mediated ATRP and RAFT polymerizations. The synthesized copolymers with molecular weights up to 1.6 million g/mol and moderate dispersities readily assemble into highly ordered cylindrical or lamella microstructures with domain sizes as large as 292 nm, as determined by ultra-small-angle x-ray scattering and scanning electron microscopy analyses. Solvent cast films of the synthesized block copolymers exhibit stop bands in the visible spectrum correlated to their domain spacings. The described method opens new avenues for facilitated fabrication and the advancement of fundamental understanding of BCP-derived photonic nanomaterials for a variety of applications.

Mapas, Jose Kenneth D.↗