Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Optimization and evaluation of metal injection molding by using X-ray tomography

6061 aluminum alloy and 316L stainless steel green bodies were obtained by using different injection parameters (injection pressure, speed and temperature). After injection process, the green bodies were scanned by X-ray tomography. The projection and reconstruction images show the different kinds of defects obtained by the improper injection parameters. Then, 3D rendering of the Al alloy green bodies was used to demonstrate the spatial morphology characteristics of the serious defects. Based on the scanned and calculated results, it is convenient to obtain the proper injection parameters for the Al alloy. Then, reasons of the defect formation were discussed. During mold filling, the serious defects mainly formed in the case of low injection temperature and high injection speed. According to the gray value distribution of projection image, a threshold gray value was obtained to evaluate whether the quality of green body can meet the desired standard. The proper injection parameters of 316L stainless steel can be obtained efficiently by using the method of analyzing the Al alloy injection. - Highlights: • Different types of defects in green bodies were scanned by using X-ray tomography. • Reasons of the defect formation were discussed. • Optimization of the injection parameters can be simplified greatly by the way of X-ray tomography. • Evaluation standard of the injection process can be obtained by using the gray value distribution of projection image.

36 MATERIALS SCIENCE↗

Facile synthesis of 3D foam-like CoNiO{sub 2} for high-performance sodium ion batteries

Graphical abstract: 3D foam-like CoNiO{sub 2} on Cu foil was synthesized by a low-temperature hydrothermal method with subsequent annealing treatment. In the following figure, the left is the schematic illustration of sodium ion and electron transportation of the CoNiO{sub 2} film, and the right is the rate performance comparison of the CoNiO{sub 2} film and scraped CoNiO{sub 2} powder. - Highlights: • CoNiO{sub 2} film is designed as the anode for sodium ion batteries. • Unique 3D foam-like structure is synthesized by a hydrothermal method. • The binder-free CoNiO{sub 2} electrode exhibits excellent sodium storage performances. - Abstract: 3D foam-like CoNiO{sub 2} on Cu foil was synthesized by a low-temperature hydrothermal method with subsequent annealing treatment. The structure and composition of the 3D foam-like CoNiO{sub 2} have been analyzed by field-emission scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). When employed as anode electrode for sodium ion batteries, the as-prepared CoNiO{sub 2} film electrode exhibited a high reversible capacity of 323.7 mAh g{sup −1} after 100 cycles at 0.1 A g{sup −1}. Moreover, the CoNiO{sub 2} film electrode delivered an excellent rate capability of 210.3 mAh g{sup −1} at 1.6 A g{sup −1}. It is believed that the remarkable electrochemical performance of the film electrode is attributed to the 3D foam-like structure and binder-free feature, which effectively improve the ionic and electron conductivity of the electrode.

36 MATERIALS SCIENCE↗

Influence of plasticizers on thermal and mechanical properties of biocomposite filaments made from lignin and polylactic acid for 3D printing

Polylactic acid (PLA) and organosolv lignin were mixed at different ratios and extruded to obtain PLA-lignin composite filaments. PLA was replaced with lignin up to 20 wt%. Two plasticizers (polyethylene glycol (PEG) 2000 and struktol TR451) were added in varying concentrations to enhance the properties of PLA_L20 (20% lignin in PLA) composite filaments. Furthermore, the effect of lignin in PLA, and PEG, and struktol in PLA_L20 composites was investigated via tensile test, differential scanning calorimetry, thermogravimetric analysis, scanning electron microscopy, Fourier transform infrared spectroscopy of the filaments, and dynamic mechanical analysis of 3D printed samples. A 2 wt% PEG was able to enhance both tensile stress and elongation at maximum load of PLA_L20 composite by 19% and 35%, respectively, whereas struktol TR451 was able to improve elongation at maximum load by 24%.

3D printing↗

A Novel Markerless Technique to Evaluate Daily Lung Tumor Motion Based on Conventional Cone-Beam CT Projection Data

Purpose: In this study, we present a novel markerless technique, based on cone beam computed tomography (CBCT) raw projection data, to evaluate lung tumor daily motion. Method and Materials: The markerless technique, which uses raw CBCT projection data and locates tumors directly on every projection, consists of three steps. First, the tumor contour on the planning CT is used to create digitally reconstructed radiographs (DRRs) at every projection angle. Two sets of DRRs are created: one showing only the tumor, and another with the complete anatomy without the tumor. Second, a rigid two-dimensional image registration is performed to register the DRR set without the tumor to the CBCT projections. After the registration, the projections are subtracted from the DRRs, resulting in a projection dataset containing primarily tumor. Finally, a second registration is performed between the subtracted projection and tumor-only DRR. The methodology was evaluated using a chest phantom containing a moving tumor, and retrospectively in 4 lung cancer patients treated by stereotactic body radiation therapy. Tumors detected on projection images were compared with those from three-dimensional (3D) and four-dimensional (4D) CBCT reconstruction results. Results: Results in both static and moving phantoms demonstrate that the accuracy is within 1 mm. The subsequent application to 22 sets of CBCT scan raw projection data of 4 lung cancer patients includes about 11,000 projections, with the detected tumor locations consistent with 3D and 4D CBCT reconstruction results. This technique reveals detailed lung tumor motion and provides additional information than conventional 4D images. Conclusion: This technique is capable of accurately characterizing lung tumor motion on a daily basis based on a conventional CBCT scan. It provides daily verification of the tumor motion to ensure that these motions are within prior estimation and covered by the treatment planning volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional structure investigation of Waterborne Paint by Electron Microscopic Imaging

In this paper, the three-dimensional (3D) spatial structure of a TiO 2 coated waterborne paint film has been successfully investigated by serial block-face scanning electron microscopy (SBFSEM). The investigation clearly shows the spatial distribution of the TiO2 particles in the paint film and illustrates the degree of dispersion of the particles in the composite material. More than 58% of the volume of the TiO 2 particles are between 1.0 × 10 6 nm 3 to 1.0 × 10 7 nm 3 and the minimum distance between different particles can be detected is 124 nm. Different types of voids can be found in the 3D image of the cured water-borne paint film: voids that exist in the paint itself, voids produced by particle shedding, water evaporating and particles stacking. Among these voids, the ones produced by particle shedding is a cutting artefact. The research provides a different approach to clearly present the 3D spatial structure of paints and can clearly illustrate different kinds of voids inside the water-borne paint. While the resulting 3D structure of the paint, especially the different voids are important for further systematic research on the relationships between the spatial microstructure and the physical and chemical properties of the water-borne paint.

36 MATERIALS SCIENCE↗

Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery

Purpose: In external-beam radiation therapy, existing on-board x-ray imaging chains orthogonal to the delivery beam cannot recover 3D target trajectories from a single view in real-time. This limits their utility for real-time motion management concurrent with beam delivery. To address this limitation, the authors propose a novel concept for on-board imaging based on the inverse-geometry Scanning-Beam Digital X-ray (SBDX) system and evaluate its feasibility for single-view 3D intradelivery fiducial tracking. Methods: A chest phantom comprising a posterior wall, a central lung volume, and an anterior wall was constructed. Two fiducials were placed along the mediastinal ridge between the lung cavities: a 1.5 mm diameter steel sphere superiorly and a gold cylinder (2.6 mm length x 0.9 mm diameter) inferiorly. The phantom was placed on a linear motion stage that moved sinusoidally. Fiducial motion was along the source-detector (z) axis of the SBDX system with {+-}10 mm amplitude and a programmed period of either 3.5 s or 5 s. The SBDX system was operated at 15 frames per second, 100 kVp, providing good apparent conspicuity of the fiducials. With the stage moving, detector data were acquired and subsequently reconstructed into 15 planes with a 12 mm plane-to-plane spacing using digital tomosynthesis. A tracking algorithm was applied to the image planes for each temporal frame to determine the position of each fiducial in (x,y,z)-space versus time. A 3D time-sinusoidal motion model was fit to the measured 3D coordinates and root mean square (RMS) deviations about the fitted trajectory were calculated. Results: Tracked motion was sinusoidal and primarily along the source-detector (z) axis. The RMS deviation of the tracked z-coordinate ranged from 0.53 to 0.71 mm. The motion amplitude derived from the model fit agreed with the programmed amplitude to within 0.28 mm for the steel sphere and within -0.77 mm for the gold seed. The model fit periods agreed with the programmed periods to within 7%. Conclusions: Three dimensional fiducial tracking with approximately 1 mm or better accuracy and precision appears to be feasible with SBDX, supporting its use to guide radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of SiO{sub 2} on the Formation of Acicular Calcium Ferrite in Sinter

SiO{sub 2} greatly influences the formation of acicular calcium ferrite (ACF), which is the main binder phase in sinter, but the mechanism of its influence is not yet clear. Experiments were carried out under air at 1200 °C with different amounts of SiO{sub 2} mixed with Fe{sub 2}O{sub 3} and Ca(OH){sub 2}. X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and three-dimensional (3D) reconstruction were used to characterize the phase and morphological changes of the sintered samples. The results show that SiO{sub 2} can form silicon-ferrite of calcium (SFC), which is beneficial to the formation of ACF in sinter. The SFC content first increased and then decreased with the increasing SiO{sub 2} content. The sintered sample contained the highest contents of SFC and ACF when w(SiO{sub 2}) was 3 to 4 pct. The morphological changes in calcium ferrite observed with the increasing SiO{sub 2} content followed a sequence of massive → platy → acicular; both platy calcium ferrite and ACF were the longest in one direction in their 3D morphology. The inclusion of Si{sup 4+} in calcium ferrite crystals changes the crystal growth habit from having no obvious orientation to having a preferential orientation along the (040) or (320) surfaces, as determined by the first-principles calculations and XRD analysis of block samples. Viscosity was the main environmental factor influencing the size of ACF in samples with sufficient liquid phase.

36 MATERIALS SCIENCE↗

Temporally Stable Supramolecular Polymeric Salts Enabling High-Performance 3D All-Aromatic Polyimide Lattices

Vat photopolymerization (VP) Additive Manufacturing (AM), in which UV light is selectively applied to cure photo-active polymers into complex geometries with micron-scale resolution, has a limited selection of aliphatic thermoset materials that exhibit relatively poor thermal performance. Ring-opening dianhydrides with acrylate-containing nucleophiles yielded diacrylate ester-dicarboxylic acids that enabled photo-active polyimide (PI) precursors, termed polysalts, upon neutralization with an aromatic diamine in solution. In situ FTIR spectroscopy coupled with a solution and photo-rheological measurements revealed a previously unknown time-dependent instability of 4,4'-oxydianiline (ODA) polysalts due to an aza-Michael addition. Replacement of the electron-donating ether-containing diamine with an electron withdrawing sulfone-containing monomer, e.g., 4,4'-diaminodiphenyl sulfone (DDS), prohibited the aza-Michael addition of the aromatic amine to the activated acrylate double bond. Novel DDS polysalt photocurable solutions are similarly analyzed and validated long-term stability, which enabled reproducible printing of polyimide organogel intermediates. Subsequent VP AM afforded 3-dimensional (3D) structures of intricate complexity and excellent surface finish, as demonstrated with scanning electron microscopy. In addition, the novel PMDA-HEA/DDS solution enabled the production of the first beam latticed architecture comprised of all-aromatic polyimide. Finally, the versatility of a polysalt platform for multi-material printing is further demonstrated by printing parts with alternating polysalt compositions.

36 MATERIALS SCIENCE↗

Polyhydroxyalkanoates/Fibrillated Nanocellulose Composites for Additive Manufacturing

Novel poly(3-hydroxybutyrate-co-3-hydroxyhexanoate)(PHBH)/fibrillated nanocellulose biodegradable composites for additive manufacturing were produced and characterized. Fibrillated nanocellulose (NCF) was isolated with high energy ultrasonication and dispersed via solution mixing in the polymer matrix. Composite filaments having a nanofiller concentration of 0.5 wt%, 1 wt% and 3 wt% were then extruded, characterized and used in fused deposition modeling (FDM). Neat PHBH powder was then manually added to prepare a solid mixture at different fibrillated nanocellulose concentrations (from 0.5 to 3 wt%), to be then used to feed an extruder. SEM observations on filaments and 3D printed samples evidenced the good dispersion of fibrillated nanocellulose inside the matrix with the presence of agglomerates at higher NCF contents. The beneficial effects of the fibrillated nanocellulose in terms of stress at break and of elongation at break showed a maximum at a fibrillated nanocellulose content of 0.5 wt%. Moreover, the presence of fibrillated nanocellulose did not affect the thermal degradation behaviour of the materials, and also the glass transition and the melting temperatures were not influenced by NCF addition.

36 MATERIALS SCIENCE↗

Exploration of Sn 70 Li 30 alloy as possible material for flowing liquid metal plasma facing components

As an advanced alternative to solid materials, Liquid Metals (LM) may offer more resilient and feasible Plasma Facing Components (PFCs). Particularly, regarding the unavoidable material erosion/degradation produced by particle/heat fluxes in future fusion devices where much longer duty cycles are expected. Furthermore, configurations that propose a flowing LM surface can add the advantage of a continuously fresh and clean layer facing the plasma. Although lithium is the most widely tested option, tin-lithium (SnLi) alloys have been proposed to attempt to combine the positive characteristics of both pure elements and ameliorate the specific issues of lithium. In this work, the potential use of Sn70Li30 alloy in such flowing concepts has been explored by addressing several preliminary and mandatory aspects for its utilization. Key issues such as wettability and compatibility of the alloy with relevant substrates have been studied in a multidisciplinary approach. The data obtained from deposited liquid tin-lithium droplets indicates approximate wetting temperatures of 360 °C, 390 °C and 405 °C for the fresh alloy on 316 stainless steel, molybdenum, and tungsten, respectively. However, the alloy contamination appeared to strongly affect the wetting characteristics of materials, increasing their wetting temperature by ~130 °C in the worst observed cases. Interestingly, in some instances, the instability of the liquid alloy surface was observed in the form of sudden gaseous ejection. The deposited droplets were posteriorly characterized in terms of absolute composition and depth profile by Inductively Coupled PlasmaOptical Emission Spectroscopy (ICP-OES) and Secondary Ion Mass Spectrometry (SIMS-ToF). Additionally, the nature and composition of the boundaries between the substrates and alloy microparticles was investigated by Scanning Electron Microscopy (SEM), Energy Dispersive X-Ray Spectroscopy (EDS), and 3D Laser microscopy. The overall results of this post-mortem characterization revealed that first signs of corrosion induced by both alloy elements (lithium-chromium association and iron-tin intermetallic mixing) were present on 316 stainless steel after short exposures (≤3 h) at temperatures lower than 550 °C. Conversely, molybdenum and tungsten showed good compatibility with the alloy in equivalent conditions. The global implications of these results are finally addressed, focusing on the future perspectives and the more viable scenarios for the eventual utilization of these alloys in flowing liquid metal configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical nanoscopy of high T c cuprate nanoconstriction devices patterned by helium ion beams

Helium ion beams (HIB) focused to subnanometer scales have emerged as powerful tools for high-resolution imaging as well as nanoscale lithography, ion milling, or deposition. Quantifying irradiation effects is an essential step toward reliable device fabrication, but most of the depth profiling information is provided by computer simulations rather than the experiment. Here, we demonstrate the use of atomic force microscopy (AFM) combined with scanning near-field optical microscopy (SNOM) to provide three-dimensional (3D) dielectric characterization of high-temperature superconductor devices fabricated by HIB. By imaging the infrared dielectric response obtained from light demodulation at multiple harmonics of the AFM tapping frequency, we find that amorphization caused by the nominally 0.5 nm HIB extends throughout the entire 26.5 nm thickness of the cuprate film and by ~500 nm laterally. This unexpectedly widespread damage in morphology and electronic structure can be attributed to a helium depth distribution substantially modified by the internal device interfaces. Lastly, our study introduces AFM-SNOM as a quantitative tomographic technique for noninvasive 3D characterization of irradiation damage in a wide variety of nanoscale devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast reconstruction of a bounded ultrasonic beam using acoustically induced piezo-luminescence

We report on the conversion of ultrasound into light by the process of piezo-luminescence in epoxy with embedded BaSi{sub 2}O{sub 2}N{sub 2}:Eu as active component. We exploit this acoustically induced piezo-luminescence to visualize several cross-sectional slices of the radiation field of an ultrasonic piston transducer (f = 3.3 MHz) in both the near-field and the far-field. Simply combining multiple slices then leads to a fast representation of the 3D spatial radiation field. We have confronted the luminescent results with both scanning hydrophone experiments and digital acoustic holography results, and obtained a good correlation between the different approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13–125 Gy).Conclusions: A three-dimensional inpatient dose reconstruction method has been developed that is based on the PET/CT data of a patient treated with {sup 90}Y microspheres. It allows for a complete description of the absorbed dose by the tumor and critical structures. It represents the first step in building predictive models for treatment outcomes for patients receiving this therapeutic modality as well as it allows for better analysis of patients' dose response and will ultimately improve future treatment administration.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

SU-C-BRA-06: Automatic Brain Tumor Segmentation for Stereotactic Radiosurgery Applications

Purpose: Stereotactic radiosurgery (SRS), which delivers a potent dose of highly conformal radiation to the target in a single fraction, requires accurate tumor delineation for treatment planning. We present an automatic segmentation strategy, that synergizes intensity histogram thresholding, super-voxel clustering, and level-set based contour evolving methods to efficiently and accurately delineate SRS brain tumors on contrast-enhance T1-weighted (T1c) Magnetic Resonance Images (MRI). Methods: The developed auto-segmentation strategy consists of three major steps. Firstly, tumor sites are localized through 2D slice intensity histogram scanning. Then, super voxels are obtained through clustering the corresponding voxels in 3D with reference to the similarity metrics composited from spatial distance and intensity difference. The combination of the above two could generate the initial contour surface. Finally, a localized region active contour model is utilized to evolve the surface to achieve the accurate delineation of the tumors. The developed method was evaluated on numerical phantom data, synthetic BRATS (Multimodal Brain Tumor Image Segmentation challenge) data, and clinical patients’ data. The auto-segmentation results were quantitatively evaluated by comparing to ground truths with both volume and surface similarity metrics. Results: DICE coefficient (DC) was performed as a quantitative metric to evaluate the auto-segmentation in the numerical phantom with 8 tumors. DCs are 0.999±0.001 without noise, 0.969±0.065 with Rician noise and 0.976±0.038 with Gaussian noise. DC, NMI (Normalized Mutual Information), SSIM (Structural Similarity) and Hausdorff distance (HD) were calculated as the metrics for the BRATS and patients’ data. Assessment of BRATS data across 25 tumor segmentation yield DC 0.886±0.078, NMI 0.817±0.108, SSIM 0.997±0.002, and HD 6.483±4.079mm. Evaluation on 8 patients with total 14 tumor sites yield DC 0.872±0.070, NMI 0.824±0.078, SSIM 0.999±0.001, and HD 5.926±6.141mm. Conclusion: The developed automatic segmentation strategy, which yields accurate brain tumor delineation in evaluation cases, is promising for its application in SRS treatment planning.

60 APPLIED LIFE SCIENCES↗

High Density Chip Interconnect Technology Using High Density Glass Interposers

Modern particle physics experiments require “intelligent detectors” with dense interconnects and distributed intelligence in very large area detector systems. Available packaging and interconnect technologies directly limit the performance and capabilities of these systems. Interposers are interconnected elements that use through-silicon or through-glass via to replace the PC board technology currently used for connecting chips and can improve the interconnect density by more than two orders of magnitude. The goal of this project is to fabricate a thru glass via interposer that will allow top to bottom side interconnects in the tens of microns. Having a thru glass interposer with interconnects in the tens of microns will benefit the electrons industry which focuses on 3D packaging. In addition to commercial, medical applications such as the CAT scan, which have resolutions in the micron or larger range, will now be able to use these interposers to diagnose in the tens of microns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RockFlow: Fast Generation of Synthetic Source Rock Images Using Generative Flow Models

Image-based evaluation methods are a valuable tool for source rock characterization. The time and resources needed to obtain images has spurred development of machine-learning generative models to create synthetic images of pore structure and rock fabric from limited image data. While generative models have shown success, existing methods for generating 3D volumes from 2D training images are restricted to binary images and grayscale volume generation requires 3D training data. Shale characterization relies on 2D imaging techniques such as scanning electron microscopy (SEM), and grayscale values carry important information about porosity, kerogen content, and mineral composition of the shale. Here, we introduce RockFlow, a method based on generative flow models that creates grayscale volumes from 2D training data. We apply RockFlow to baseline binary micro-CT image volumes and compare performance to a previously proposed model. We also show the extension of our model to 2D grayscale data by generating grayscale image volumes from 2D SEM and dual modality nanoscale shale images. The results show that our method underestimates the porosity and surface area on the binary baseline datasets but is able to generate realistic grayscale image volumes for shales. With improved binary data preprocessing, we believe that our model is capable of generating synthetic porous media volumes for a very broad class of rocks from shale to carbonates to sandstone.

58 GEOSCIENCES↗

Hurricane Directional Wave Spectrum Spatial Variation in the Open Ocean

The sea surface directional wave spectrum was measured for the first time in all quadrants of a hurricane in open water using the NASA airborne scanning radar altimeter (SRA) carried aboard one of the NOAA WP-3D hurricane hunter aircraft at 1.5 km height. The SRA measures the energetic portion of the directional wave spectrum by generating a topographic map of the sea surface. At 8 Hz, the SRA sweeps a radar beam of 1 deg half-power width (two-way) across the aircraft ground track over a swath equal to 0. 8 of the aircraft height, simultaneously measuring the backscattered power at its 36 GHz (8.3 mm) operating frequency and the range to the sea surface at 64 positions. These slant ranges are multiplied by the cosine of the incidence angles to determine the vertical distances from the aircraft to the sea surface. Subtracting these distances from the aircraft height produces the sea surface elevation map. The sea surface topography is interpolated to a uniform grid, transformed by a two-dimensional FFT, and Doppler corrected. The data presented were acquired on 24 August 1998 when hurricane Bonnie was east of the Bahamas and moving slowly to the north. Wave heights up to 18 m were observed and the spatial variation of the wave field was dramatic. The dominant waves generally propagated at significant angles to the downwind direction and at times there were wave fields traveling at right angles to each other. The NOAA aircraft spent over five hours within 180 km of the hurricane Bonnie eye, and made five eye penetrations. A 2-minute animation of the directional wave spectrum spatial variation over this period will be shown.

Wright, C. W.↗