Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABERRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Radiative equilibrium in rapidly expanding shells

The equation of radiative equilibrium for rapidly expanding spherical shells including the special relativistic terms is discussed, and a temperature-correction procedure for the solution of this equation is given. The temperature-correction scheme combines a partial linearization approach with the approximate Lambda-operator iteration method. For some test problems, the temperature structures of atmospheres in radiative equilibrium in the Lagrangian frame are calculated. The effects of the velocity field on the temperature stratification and the luminosity are also discussed. We find that the temperature structure of a moving photosphere in radiative equilibrium in the Lagrangian frame differs significantly from that of a static photosphere and that, at least, all first-order terms, in particular the advection and aberration terms, have to be included consistently both in the radiative transfer and the energy equation in studies of supernovae atmospheres and other high-speed radiating flows.

Hauschildt, P. H.↗

Optical design and testing of a fast, large aperture, infrared space telescope

An optical design study for a next generation infrared space telescope has been performed. The concept is that of a passively cooled telescope of minimum aperture 2.5 m with an F/1.2 primary and wavelength coverage from 2 to as least 40 microns, and possibly to 100 microns. Compactness, low thermal emission from the optics and structure, diffraction limited imaging at 2 microns, and sensitivity to misalignment aberrations and manufacturing errors were the main considerations for this study. Ray tracing results are presented showing the characteristics of the various designs considered. A preliminary investigation of stray light properties is also given. Special emphasis has been placed on the testing of such a fast primary, and optical systems using a lateral shearing interferometer are described for testing both the primary and the primary/secondary combination.

Humphries, C. M.↗

Direct 75 milliarcsecond images from the Multiple Mirror Telescope with adaptive optics

We report results from an adaptive optics system designed to provide imaging at the diffraction limit of resolution in the near-infrared at the Multiple Mirror Telescope (MMT). For the present experiment, the aperture consisted of five of the six primary mirrors of the MMT, operating as a coherently phased array. The largest components of the atmospherically induced wave-front aberration are the fluctuations in mean phase between the segments. These errors were derived in real time from the Fourier transform of short-exposure stellar images at 2.2 microns and corrected at an image of the telescope pupil with piston motion from a segmented adaptive mirror. At a correction rate of 43 Hz, this level of adaptive control resulted in an integrated image with a clear diffraction-limited component of 0.075 arcsec FWHM. This stabilized component is present directly in the light arriving at the detector and is not the result of postprocessing. We discuss future improvements to our adaptive wave-front control and its application to astronomical observations.

Lloyd-Hart, M.↗

Theory and operation of a three-gate time-of-flight velocity analyzer

Theoretical considerations and test results are presented for a new-type velocity analyzer for incident fast neutral particles, positive ions, and negative ions. Velocity analysis is carried out by means of a pulsed, three-gate time-of-flight (TOF) technique capable of eliminating alias velocities (harmonics) to sixth order. In addition the design and operation are presented of a four-element ion lens system, with small spherical and chromatic aberrations, suitable for interfacing a large-diameter ion beam from the TOF section with a subsequent mass analyzer.

Martus, K. E.↗

The effects of thermal gradients on the Mars Observer Camera primary mirror

The paper discusses the effect of thermal gradients on the optical performance of the primary mirror of Mars Observer Camera (MOC), which will be launched on the Mars Observer spacecraft in September 1992. It was found that mild temperature gradients can have a large effect on the mirror surface figure, even for relatively low coefficient-of-thermal-expansion materials. However, in the case of the MOC primary mirror, it was found that the radius of curvature (ROC) of the reflective surface of the mirror changed in a nearly linear fashion with the radial temperature gradient, with little additional aberration. A solid-state ROC controller using the thermal gradient effect was implemented and verified.

Applewhite, Roger W.↗

Observations of 3C 273 with the Goddard High Resolution Spectrograph on the Hubble Space Telescope

The observations of the quasar 3C 273 taken with the Goddard High Resolution Spectrograph in 1991 February are presented here. We have included both the reduced raw data, and smoothed and deconvolved spectra. Also, a list of observed absorption lines is presented. The data comprise 11 spectra, including one low resolution and 10 medium resolution observations. The wavelength region covered ranged from about 1150 to 2820 A, but was not all inclusive. The procedures used to obtain and reduce the data, including corrections for fixed pattern noise, compensation for the effects of spherical aberration in the HST primary mirror, and objective detection of weak absorption lines, are described. We also have included a short discussion on the detection of galactic Ni II and Virgo cluster metal lines.

Brandt, J. C.↗

Design of spherical varied line-space gratings for a high-resolution EUV spectrometer

A highly efficient EUV spectrograph is designed for high-resolution spectroscopic observation. The spectrograph is designed for point source astronomy in a 40-120 nm bandpass and is to be ORFEUS (Orbiting Retrievable Far and Extreme Ultraviolet Spectrometer), scheduled for launch as the first payload of a German space platform Astro-SPAS (Astronomy Shuttle Pallet Satellite). The design uses spherical varied line-space (SVLS) grating to minimize astigmatism, coma, and spherical aberration. The effectiveness and practical feasibility of the design is proved by an SVLS grating for visible use. The image focusing properties of the SVLS grating for ORFEUS are compared to those with toroidal uniform line-space (TULS) design. The SVLS design is superior to the TULS, theoretically in resolution and image concentration, but also practically with not only fabrication ease. Four SVLS gratings with nominal groove densities of 6000, 4550, 3450, and 2616 gr./mm, and a 200 mm x 200 mm ruled area have been ruled using a numerically controlled ruling engine for use in ORFEUS.

Harada, Tatsuo↗

Design and analysis of a depolarizer for the NASA moderate resolution imaging spectrometer-tilt (MODIS-T)

The design and analysis of a depolarizer for the NASA MODIS-T spectrometer is presented. The theory of spatial pseudodepolarizer operation and its effect on linear polarization sensitivity is described. Details of the HV depolarizer design and issues of depolarizer location and material are discussed. The image doubling and aberrations induced by the depolarizer and the trade-offs between increased polarization performance and decreased image quality are also addressed. The issues considered apply directly to depolarizer design for other remote sensing instruments.

Mcclain, Stephen C.↗

On-orbit performance of the Hubble Space Telescope fine guidance sensors

The observed and measured on-orbit performance of various aspects of the fine guidance sensors is presented and discussed in the light of the original requirements and predictions. The fine guidance sensors are shown to meet or exceed the original requirements concerning dynamic pointing errors, photometric repeatability, and moving-target tracking capability. Calibration accuracy has been sufficient for observations to date, and fine-lock acquisitions are approaching a 100 percent success rate. Improvements to the fine-guidance-sensor tolerance of telescope spherical aberration, the South Atlantic anomaly, and solar-panel vibrations have been made, and further improvements are expected.

Eaton, David J.↗

Hubble Space Telescope prescription retrieval

Prescription retrieval is a technique for directly estimating optical prescription parameters from images. We apply it to estimate the value of the Hubble Space Telescope primary mirror conic constant. Our results agree with other studies that examined primary-mirror test fixtures and results. In addition they show that small aberrations exist on the planetary-camera repeater optics.

Redding, David↗

Telescope simulators for Hubble - An overview of optical designs

This paper briefly describes optical design of the Hubble Space Telescope (HST) and overviews three optical design simulators for HST which have been proposed for use as verification tools to characterize the performance of second-generation instruments during ground testing. These simulators are: the Refractive Aberrated Simulator developed at Ball Aerospace, the Optical Simulator developed at Laboratoire Astronomie Spatiale, and the Jet Propulsion Laboratory Stimulus. Relative advantages and disadvantages of each optical configuration are discussed.

Davilla, Pam↗

Hubble Space Telescope COSTAR asphere verification with a modified computer-generated hologram interferometer

To correct for the spherical aberration in the Hubble Space Telescope primary mirror, five anamorphic aspheric mirrors representing correction for three scientific instruments have been fabricated as part of the development of the corrective-optics space telescope axial-replacement instrument (COSTAR). During the acceptance tests of these mirrors at the vendor, a quick and simple method for verifying the asphere surface figure was developed. The technique has been used on three of the aspheres relating to the three instrument prescriptions. Results indicate that the three aspheres are correct to the limited accuracy expected of this test.

Feinberg, L.↗

Two-mirror projection systems for simulating telescopes

Optical instruments designed for use with large telescopes need to be tested before being installed at their work site. This is especially true for space-based instruments. To perform these tests, an auxiliary optical system is required which simulates the telescope exit pupil. Two-mirror projection systems can be used for this purpose. In this paper the first-order geometric properties and third-order aberrations of the general two-mirror system used at finite conjugates are examined. Relations are given in terms of five design parameters: object distance, image distance, exit pupil size, and the two mirror magnifications. A particular application of these relations is presented for a system designed to simulate the HST, for ground testing of the next generation of scientific instruments to be installed in the observatory. We show that a sufficient number of degrees of freedom are available to meet requirements when both mirrors are conics.

Hannan, Paul G.↗

Debris Collision Warning Sensor (DCWS) telescope design

The 60-cm diameter, f/2 DCWS telescope is a modified Ritchey Chretein configuration which collects radiation in three spectral bands, 0.4 to 0.9/micron (visible), 5.0 to 9.0/microns (MWIR), and 9.0 to 12.0 microns (LWIR). The visible and infrared radiation are separated by a dichroic beamsplitter and focused on to separate focal planes; the MWIR and LWIR radiation share a common focal plane with separate detector arrays residing side-by-side. The conic constants of the primary and secondary mirrors are that of a Ritchey Chretein telescope; to improve the image quality at the edges of the field of view, a set of zero power correcting optics have been introduced to each optical train. The Ritchey Chretein telescope is corrected to have zero third order spherical aberration and zero third order coma; the DCWS telescope is further configured such that the positive power in the primary mirror is approximately equal to the negative power in the secondary mirror, resulting in a telescope with very little field curvature.

Brown, Robert J.↗

Multilayer and grazing incidence X-ray/EUV optics for astronomy and projection lithography; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992

The present volume on multilayer and grazing incidence X-ray/EUV optics for astronomy and projection lithography discusses AXAF grazing incidence mirrors, the theory and high throughput optics of grazing incidence optics, multilayer mirror fabrication and characterization, and multilayer optics for X-ray projection lithography. Attention is given to the VETA-I X-ray detection system, a motion detection system for AXAF X-ray ground testing, image analysis of the AXAF VETA-I X-ray mirror, and optical constants from mirror reflectivities measured at synchrotrons. Topics discussed include the application of aberration theory to calculate encircled energy of Wolter I-II telescopes, W/C multilayers deposited on plastic films, nonspecular X-ray scattering from Si/Mo multilayers, and multilayer thin-film design as FUV polarizers. Also discussed are thin-film filter lifetesting results in the EUV, chromospheric and coronal observations with multilayer optics, present and future requirements of soft X-ray projection lithography, and the imaging Schwarzschild multilayer X-ray microscope.

Hoover, Richard B.↗

The FK5 Extension on the FK4 system

This paper reports on the computations necessary to place the FK5 Extension (epoch of place B1950.0) on the B1950.0/FK4 system from its published form and the availability of this version of the catalog. An application of the utility of the new version of the FK5 Extension, to the AGK3U, is given too. This confirms both the system of the AGK3U and the estimated values of its equatorial coordinate and proper motion mean errors. In addition, we have fully exploited the flexibility of the method of infinitely overlapping circles to compute a mean epoch of place/FK4 version of the FK5 Extension which we also make available. These modifications include taking into account the changes induced by the new system of general precession constants, adjusting for the e-terms of aberration, correcting for both the FK5/FK4 equinox offset and motion, and the FK5/FK4 positional and the proper motion systematic differences.

Lattanzi, M. G.↗

Faint Object Camera observations of M87 - The jet and nucleus

UV and optical images of the central region and jet of the nearby elliptical galaxy M87 have been obtained with about 0.1 arcsec resolution in several spectral bands with the Faint Object Camera (FOC) on the HST, including polarization images. Deconvolution enhances the contrast of the complex structure and filamentary patterns in the jet already evident in the aberrated images. Morphologically there is close similarity between the FOC images of the extended jet and the best 2-cm radio maps obtained at similar resolution, and the magnetic field vectors from the UV and radio polarimetric data also correspond well. We observe structure in the inner jet within a few tenths arcsec of the nucleus which also has been well studied at radio wavelengths. Our UV and optical photometry of regions along the jet shows little variation in spectral index from the value 1.0 between markedly different regions and no trend to a steepening spectrum with distance along the jet.

Boksenberg, A.↗

Deformed ellipsoidal gratings for far-ultraviolet spectrographs - Analytic optimization

Analytic formulas are developed for the semiaxes and for the deformation coefficients of a deformed ellipsoidal grating that minimize aberrations over a given spectral range. These include the Rowland circle mount and quasi-Rowland circle mounts, as required for systems that combine spectra from multiple gratings on a common detector. It is also shown that the necessary condition for a holographic grating to give a better performance over a conventional grating is the use of a convergent beam and a divergent beam for the recording. Examples applicable to the Far-Ultraviolet Spectroscopic Explorer are given. The light-path function for a deformed ellipsoidal holographic grating is also presented.

Content, David↗