Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Generating ultrabroadband terahertz radiation based on the under-compression mode of velocity bunching

We propose and analyze a scheme to generate enhanced ultrabroadband terahertz (THz) radiation through coherent transition radiation emitted by ultrashort electron beams based on a 10.5 m beamline at Tsinghua University. The proposed scheme involves the initial compression of the electron beam with a few hundred pC charges using a velocity bunching scheme (i.e., RF compression) in an under-compression mode instead of the usual critical-compression mode in order to maintain a positive energy chirp at the exit of the traveling wave accelerator. After a long drift segment, the particles in the tail catch up with the bunch head. More than 80% of the particles are distributed in a spike with an rms length less than 20 fs. Such beams correspond to an ultrabroadband coherent transition radiation (CTR) spectrum of 0.1 THz to 25 THz, with the single-pulse THz radiation energy of up to 50 {mu}J. The principle of CTR and under-compression mode of velocity bunching are introduced in this paper. And the ASTRA simulation parameters and the stability of the system are also discussed.

43 PARTICLE ACCELERATORS↗

Key elements of space charge compensation on a low energy high intensity beam injector

Space charge effect (SCE) along the beam line will decrease beam quality. Space charge compensation (SCC) with extra gas injection is a high-efficiency method to reduce SCE. In this paper, we will report the experimental results on the beam profile, potential distribution, beam emittance, and beam transmission efficiency of a 35 keV/90 mA H{sup +} beam and a 40 keV/10 mA He{sup +} beam compensated by Ar/Kr. The influence of gas type, gas flow, and injection location will be discussed. Emphasis is laid on the consideration of SCC when designing and commissioning a high intensity ion beam injector. Based on measured data, a new definition of space charge compensation degree is proposed.

43 PARTICLE ACCELERATORS↗

Improved sliced velocity map imaging apparatus optimized for H photofragments

Time-sliced velocity map imaging (SVMI), a high-resolution method for measuring kinetic energy distributions of products in scattering and photodissociation reactions, is challenging to implement for atomic hydrogen products. We describe an ion optics design aimed at achieving SVMI of H fragments in a broad range of kinetic energies (KE), from a fraction of an electronvolt to a few electronvolts. In order to enable consistently thin slicing for any imaged KE range, an additional electrostatic lens is introduced in the drift region for radial magnification control without affecting temporal stretching of the ion cloud. Time slices of {approx}5 ns out of a cloud stretched to Greater-Than-Or-Slanted-Equal-To 50 ns are used. An accelerator region with variable dimensions (using multiple electrodes) is employed for better optimization of radial and temporal space focusing characteristics at each magnification level. The implemented system was successfully tested by recording images of H fragments from the photodissociation of HBr, H{sub 2}S, and the CH{sub 2}OH radical, with kinetic energies ranging from <0.4 eV to >3 eV. It demonstrated KE resolution Less-Than-Or-Equivalent-To 1%-2%, similar to that obtained in traditional velocity map imaging followed by reconstruction, and to KE resolution achieved previously in SVMI of heavier products. We expect it to perform just as well up to at least 6 eV of kinetic energy. The tests showed that numerical simulations of the electric fields and ion trajectories in the system, used for optimization of the design and operating parameters, provide an accurate and reliable description of all aspects of system performance. This offers the advantage of selecting the best operating conditions in each measurement without the need for additional calibration experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The source-sample stage of the new two-dimensional angular correlation of annihilation radiation spectrometer at Technische Universitaet Muenchen

Angular correlation of annihilation radiation (ACAR) is a well established technique for the investigation of the electronic structure. A major limitation of ACAR studies is the available positron flux at a small spot on the sample. For this reason, the focus of this work is put on the discussion of a newly developed source-sample stage of the new 2D-ACAR spectrometer at Technische Universitaet Muenchen which uses an optimized static magnetic field configuration to guide the positrons onto the sample. The achieved spot diameter is d{sub FWHM}= 5.4 mm, with a high efficiency over the whole energy spectrum of the {sup 22}Na positron source. The implications of the performance of the source-sample stage are discussed with regard to 2D-ACAR measurements of single crystalline {alpha}-quartz, which serves as a model system for the determination of the total resolution. A value of (1.53 Multiplication-Sign 1.64) mrad{sup 2} FWHM was achieved at room temperature.

43 PARTICLE ACCELERATORS↗

The new bern PET cyclotron, its research beam line, and the development of an innovative beam monitor detector

The new Bern cyclotron laboratory aims at industrial radioisotope production for PET diagnostics and multidisciplinary research by means of a specifically conceived beam transfer line, terminated in a separate bunker. In this framework, an innovative beam monitor detector based on doped silica and optical fibres has been designed, constructed, and tested. Scintillation light produced by Ce and Sb doped silica fibres moving across the beam is measured, giving information on beam position, shape, and intensity. The doped fibres are coupled to commercial optical fibres, allowing the read-out of the signal far away from the radiation source. This general-purpose device can be easily adapted for any accelerator used in medical applications and is suitable either for low currents used in hadrontherapy or for currents up to a few {mu}A for radioisotope production, as well as for both pulsed and continuous beams.

43 PARTICLE ACCELERATORS↗

Development of ion beams for space effects testing using an ECR ion source

At LBNL's 88-Inch Cyclotron and Berkeley Accelerator Space Effects (BASE) Facility, a range of ion beams at energies from 1 to 55 MeV/nucleon are used for radiation space effects testing. By bombarding a component with ion beams the radiation component of the space environment can be simulated and single event effects (SEEs) determined. The performance of electronic components used in space flight and high altitude aircraft can then be evaluated. The 88- Inch Cyclotron is coupled to the three electron cyclotron resonance ion sources (ECR, AECR-U, VENUS). These ion sources provide a variety of ion species, ranging from protons to heavy ions such as bismuth, for these tests. In particular the ion sources have been developed to provide {sup c}ocktails{sup ,} a mixture of ions of similar mass-to-charge ratio, which can be simultaneously injected into the cyclotron, but selectively extracted from it. The ions differ in both their linear energy transfer (LET) deposited to the part and in their penetration depth into the tested part. The current heavy ion cocktails available are the 4.5, 10, 16, and 30 MeV per nucleon.

43 PARTICLE ACCELERATORS↗

Simulation of ion beam transport through the 400 Kv ion implanter at Michigan Ion Beam Laboratory

The Michigan Ion Beam Laboratory houses a 400 kV ion implanter. An application that simulates the ion beam trajectories through the implanter from the ion source to the target was developed using the SIMION Registered-Sign code. The goals were to have a tool to develop an intuitive understanding of abstract physics phenomena and diagnose ion trajectories. Using this application, new implanter users of different fields in science quickly understand how the machine works and quickly learn to operate it. In this article we describe the implanter simulation application and compare the parameters of the implanter components obtained from the simulations with the measured ones. The overall agreement between the simulated and measured values of magnetic fields and electric potentials is {approx}10%.

43 PARTICLE ACCELERATORS↗

Generation of first hard X-ray pulse at Tsinghua Thomson Scattering X-ray Source

Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 Multiplication-Sign 10{sup 6} per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.

43 PARTICLE ACCELERATORS↗

Optical design of the short pulse x-ray imaging and microscopy time-angle correlated diffraction beamline at the Advanced Photon Source

The short pulse x-ray imaging and microscopy beamline is one of the two x-ray beamlines that will take full advantage of the short pulse x-ray source in the Advanced Photon Source (APS) upgrade. A horizontally diffracting double crystal monochromator which includes a sagittally focusing second crystal will collect most of the photons generated when the chirped electron beam traverses the undulator. A Kirkpatrick-Baez mirror system after the monochromator will deliver to the sample a beam which has an approximately linear correlation between time and vertical beam angle. The correlation at the sample position has a slope of 0.052 ps/{mu}rad extending over an angular range of 800 {mu}rad for a cavity deflection voltage of 2 MV. The expected time resolution of the whole system is 2.6 ps. The total flux expected at the sample position at 10 keV with a 0.9 eV energy resolution is 5.7 Multiplication-Sign 10{sup 12} photons/s at a spot having horizontal and vertical full width at half maximum of 33 {mu}m horizontal by 14 {mu}m vertical. This new beamline will enable novel time-dispersed diffraction experiments on small samples using the full repetition rate of the APS.

43 PARTICLE ACCELERATORS↗

Focusing giga-electronvolt heavy ions to micrometers at the Institute of Modern Physics

To study the radiation effect of cosmic heavy ions of low fluxes in electronics and living samples, a focusing heavy ion microbeam facility, for ions with energies of several MeV/u up to 100 MeV/u, was constructed in the Institute of Modern Physics of the Chinese Academy of Sciences. This facility has a vertical design and an experiment platform for both in-vacuum analysis and in-air irradiation. Recently, microbeam of {sup 12}C{sup 6+} with energy of 80.55 MeV/u was successfully achieved at this interdisciplinary microbeam facility with a full beam spot size of 3 {mu}m Multiplication-Sign 5 {mu}m on target in air. Different from ions with energy of several MeV/u, the very high ion energy of hundred MeV/u level induces problems in beam micro-collimation, online beam spot diagnosis, radiation protection, etc. This paper presents the microbeam setup, difficulties in microbeam formation, and the preliminary experiments performed with the facility.

36 MATERIALS SCIENCE↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Compact integrated X-ray intensity and beam position monitor based on rare gas scintillation

We have created and tested a compact integrated X-ray beam intensity and position monitor using Ar-gas scintillation. The light generated inside the device's cavity is detected by diametrically opposed PIN diodes located above and below the beam. The intensity is derived from the sum of the top and bottom signals, while the beam position is calculated from the difference-over-sum of the two signals. The device was tested at Cornell High Energy Synchrotron Source with both 17 keV and 59 keV x-rays. For intensity monitoring, the Ar-scintillation monitor performance is comparable to standard ion chambers in terms of precision. As an X-ray beam position monitor the new device response is linear with vertical beam position over a 2 mm span with a precision of 2 {mu}m.

43 PARTICLE ACCELERATORS↗

Terahertz free electron superradiation from mimicking surface plasmons-two electron beams interaction within a 3-mirror quasi-optical cavity

Interaction between mimicking surface plasmons and electron beams provides a good opportunity to develop terahertz (THz) radiation sources. In this paper, such an interaction in a special 3-mirror quasi-optical cavity is presented and explored. The 3-mirror quasi-optical cavity acts as a resonant tunable system, the resonance frequency of which can be tuned by adjusting the distance between mirrors. The study demonstrated THz free electron superradiation from the interaction of mimicking surface plasmons and two electron beams that formed a resonance within the structure, with the 3-mirror cavity enhancing the intensity of superradiation. Moreover, this system can work in the high-harmonic superradiation region with relatively high efficiency and low current density. This concept thus shows the application potential for electron-beam-driven terahertz sources.

43 PARTICLE ACCELERATORS↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

Development of a cryogenic load frame for the neutron diffractometer at Takumi in Japan Proton Accelerator Research Complex

To prepare for projects such as the Large Hadron Collider upgrade, International Thermonuclear Experimental Reactor and Demonstration reactor, it is important to form a clear understanding of stress-strain properties of the materials that make up superconducting magnets. Thus, we have been studying the mechanical properties of superconducting wires using neutron diffraction measurements. To simulate operational conditions such as temperature, stress, and strain, we developed a cryogenic load frame for stress-strain measurements of materials using a neutron diffractometer at Japan Proton Accelerator Research Complex (J-PARC) Takumi beam line. The maximum load that can be applied to a sample using an external driving machine is 50 kN. Using a Gifford-MacMahon cryocooler, samples can be measured down to temperatures below 10 K when loaded. In the present paper, we describe the details of the cryogenic load frame with its test results by using type-304 stainless steel wire.

43 PARTICLE ACCELERATORS↗

Grating monochromator for electron cyclotron resonance ion source operation

Recently, we started to observe optical line spectra from an ECR plasma using a grating monochromator with a photomultiplier. The light intensity of line spectrum from the ECR plasma had a strong correlation with ion beam intensity measured by a magnetic mass analyzer. This correlation is a significant information for beam tuning because it allows the extraction of the desired ion species from the ECR plasma. Separation of ion species of the same charge to mass ratio with an electromagnetic mass analyzer is known to be an exceptionally complex process, but this research gives new insights into its simplification. In this paper, the grating monochromator method for beam tuning of a Hyper-ECR ion source as an injector for RIKEN azimuthal varying field (AVF) cyclotron is described.

43 PARTICLE ACCELERATORS↗

Focused electron beam in pyroelectric electron probe microanalyzer

We report a method to focus the electron beam generated using a pyroelectric crystal. An electron beam with a spot size of 100 μm was achieved by applying an electrical field to an electroconductive needle tip set on a pyroelectric crystal. When the focused electron beam bombarded a sample, characteristic X-rays of the sample were only detected due to the production of an electric field between the needle tip and the sample.

43 PARTICLE ACCELERATORS↗

Microwave radiation power of relativistic electron beam with virtual cathode in the external magnetic field

The study of the output power of the electromagnetic radiation of the relativistic electron beam (REB) with virtual cathode in the presence of external magnetic field has been found out. The typical dependencies of the output microwave power of the vircator versus external magnetic field have been analyzed by means of 3D electromagnetic simulation. It has been shown that the power of vircator demonstrates several maxima with external magnetic field growth. The characteristic features of the power behavior are determined by the conditions of the virtual cathode formation in the presence of the external transversal magnetic field and the REB self-magnetic fields.

43 PARTICLE ACCELERATORS↗