Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-49: The Evaluation of Usability of Multileaf Collimator for Diagnostic Radiation in Cephalometric Exposure

Purpose: This study evaluated usability of Multileaf collimator (MLC) for diagnostic radiation in cephalometric exposure using optical stimulated luminance dosimeters (OSLDs) Methods: The MLC material was made alloy tool steel (SKD-11) and the density of it is 7.89g/m3 that is similar to it of steel (Fe, 7.85 g/m3) and the MLC was attached to general radiography unit (Rex-650R, Listem Inc, Korea) for cephalometric exposure. The OSLDs that used were nanoDotTM Dosimeter (Landauer Inc, Glenwood, USA) and we read out OSLDs with micro star system (Landauer Inc, Glenwood, USA). The Optical annealing system contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To measure absorbed dose using OSLDs, was carried out dosimetric characteristics of OSLDs. Based on these, we evaluated dose reduction of critical organ (Eyes, Thyroids) with MLC in cephalometric exposure Results: The dosimetric characteristics were following that batch homogeneity was 1.21% and reproducibility was 0.96% of the coefficient of variation The linearity was that the correlation of between dose and count was fitted by linear function (dose,mGy = 0.00029 × Count, R2 =0.997). The range of angular dependence was from −3.6% to 3.7% variation when each degree was normalized by zero degree. The organ dose of Rt. eye, Lt eye, thyroids were 77.8 μGy, 337.0 μGy, 323.1μGy, respectively in open field and the dose reduction of organ dose was 10.6%(8.3μGy), 12.4 %(42 μGy), 87.1%(281.4μGy) with MLC Conclusion: We certified dose reduction of organ dose in cephalometric exposure. The dose reduction of Eye was 11% because of reduction of field size and it of thyroids was 87% by primary beam shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-235: Monte Carlo Analysis of the Dose Enhancement in the Scalp of Patients Due to Titanium Plate Backscatter During Post-Operative Radiotherapy

Purpose: To quantify the clinically observed dose enhancement adjacent to cranial titanium fixation plates during post-operative radiotherapy. Methods: Irradiation of a titanium burr hole cover was simulated using Monte Carlo code MCNPX for a 6 MV photon spectrum to investigate backscatter dose enhancement due to increased production of secondary electrons within the titanium plate. The simulated plate was placed 3 mm deep in a water phantom, and dose deposition was tallied for 0.2 mm thick cells adjacent to the entrance and exit sides of the plate. These results were compared to a simulation excluding the presence of the titanium to calculate relative dose enhancement on the entrance and exit sides of the plate. To verify simulated results, two titanium burr hole covers (Synthes, Inc. and Biomet, Inc.) were irradiated with 6 MV photons in a solid water phantom containing GafChromic MD-55 film. The phantom was irradiated on a Varian 21EX linear accelerator at multiple gantry angles (0–180 degrees) to analyze the angular dependence of the backscattered radiation. Relative dose enhancement was quantified using computer software. Results: Monte Carlo simulations indicate a relative difference of 26.4% and 7.1% on the entrance and exit sides of the plate respectively. Film dosimetry results using a similar geometry indicate a relative difference of 13% and -10% on the entrance and exit sides of the plate respectively. Relative dose enhancement on the entrance side of the plate decreased with increasing gantry angle from 0 to 180 degrees. Conclusion: Film and simulation results demonstrate an increase in dose to structures immediately adjacent to cranial titanium fixation plates. Increased beam obliquity has shown to alleviate dose enhancement to some extent. These results are consistent with clinically observed effects.

60 APPLIED LIFE SCIENCES↗

TU-F-18A-05: An X-Ray Fluorescence Technique for Energy Calibration of Photon-Counting Detectors

Purpose: To investigate the feasibility of energy response calibration of a Si strip photon-counting detector by using the x-ray fluorescence technique. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on Si strips. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing Ag, I, Ba, and Gd, were placed in small plastic aliquots with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known energies for materials. The energy resolution was derived from the full width at half maximum (FWHM) of the fluorescence peaks. In addition, the angular dependence of the recorded fluorescence spectra was studied at 30°, 60°, and 120°. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The recorded pulse height was calibrated with respect to photon energy and the gain and offset values were calculated to be 7.0 mV/keV and −69.3 mV, respectively. Negligible variation in energy calibration was observed among the four energy thresholds. The variation among different pixels was estimated to be approximately 1 keV. The energy resolution of the detector was estimated to be 7.9% within the investigated energy range. Conclusion: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the detector. The proposed x-ray fluorescence technique provides an accurate and efficient way to calibrate the energy response of a photon-counting detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-108: An Investigation of Cerenkov Light Production in the Exradin W1 Scintillator Under Various Measurement Conditions

Purpose: To investigate the effects of depth, fiber-optic cable bends, and incident radiation angle on Cerenkov production in the Standard Imaging Exradin W1. Methods: Measurements were completed using a Varian Clinac 21EX linear accelerator with an Exradin W1 scintillator as well as a cable-only scintillator (no scintillation material) to isolate the Cerenkov signal. The effects of cable bend radius and location were investigated by bending the fiber-optic cable into a circle with radii ranging from 1.0 to 10.8 cm and positioning the center of the coil at distances ranging from 10.0 to 175.0 cm from the photodiode. The effects of depth and incident radiation angle were investigated by performing measurements in water at depths ranging from 1.0 cm to 25.0 cm and angles ranging from 0° to 80°. Eclipse treatment-planning software was utilized to ensure a consistent dose was delivered to the W1 regardless of depth or angle. Results: Measured signal in both channels of the cable-only scintillator decreased as the bend radius decreased and as the distance between the bend and photodiode increased. A fiber bend of 1.0 cm radius produced a 17.1% decrease in the green channel response in the cable-only scintillator. The effect of depth was less severe; a maximum increase of 6.6% in the green channel response was observed at a depth of 25.0 cm in the W1. In the angular dependence investigation, the signal in both channels of the W1 peaked at an angle of 40°; which is in agreement with the nominal Cerenkov emission angle of 45°. Conclusion: The green channel response in the W1 (mainly Cerenkov signal) varied with depth, fiber-optic cable bends, and incident radiation angle. Fully characterizing Cerenkov production is essential to ensure it is properly accounted for in scintillator measurements. Research funding and materials received by Standard Imaging, Inc. (Middleton WI)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-672: Real-Time In Vivo Dosimeters Using LiPCDA and Optical Fibers

Purpose: To investigate dosimeter prototypes made with lithium pentacosa-10,12-diynoate (LiPCDA, the material used in GafChromic EBT films) and optical fibers for their suitability in real-time in vivo measurements. Methods: The prototypes, made with 500 µm plastic optical fibers and 8.5 µm thickness of LiPCDA at fiber tip, were irradiated with a 6 MV beam. To investigate the efficacy of pre-irradiation calibration, the probes were irradiated to 2 Gy twice, with 5 minutes in between. Net optical density values (netOD) around the main absorbance peak were compared, and effect of correcting second measurement by the first was assessed. Ageing was assessed by irradiating two prototypes to 2 Gy and comparing the netOD to that obtained for 15 prototypes from the same batch 12–14 months earlier. To measure angular dependence, the probes were pre-irradiated with beam perpendicular to fiber axis and then, 5 minutes later either perpendicular or parallel to fiber axes. The thickness-corrected netOD measurements were compared. Results: Standard deviation of netOD for probes of the same batch was measured to be 5–6%. When netOD was corrected for material thickness by using results from the first irradiation, the standard deviation decreased to 1.3%. This was comparable to the uncertainty in measurements observed with a single probe and is attributed to variations in light output, spectrometer noise and splitter-to-probe connection variations. Comparison of netOD values obtained a year apart failed to illustrate statistically significant decrease in sensitivity due to ageing (0.38 ± 0.03 and 0.3656 ± 0.0003). NetOD measured with MV beam parallel to fiber was within error of netOD measured with MV beam perpendicular to fiber. Conclusion: Current prototype construction allows for shelf life of at least one year. With material thickness corrected for, the prototypes can measure dose with an uncertainty below 2% at a given energy and dose rate. This work has been funded by the Ontario Centres of Excellence Market Readiness grant. The authors have no conflict of interest to declare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRB-04: A Novel Monolithic Silicon 2D Detector Array for Use in Stereotactic Applications

Purpose: To assess the capability of a novel 2D monolithic silicon detector array in measuring stereotactic photon fields. Methods: The silicon array detector used in this work, named Magic Plate-512 (MP512), is a thin monolithic silicon wafer (52 × 52 × 0.47 mm{sup 3}) with 512 ion-implanted diodes (0.5 × 0.5 mm{sup 2}). Adjacent pixels are spaced evenly with 2 mm pitch, covering a maximum detection area 46 mm wide. Its fast, FPGA based read-out system is synchronised with the linac to allow readout of all pixels pulse-by-pulse. A clinical SABR lung plan (consisting of 9 single segment beams, 6MV) was measured with the array at 1.5 cm depth in a solid water phantom (100 cm SSD). The typical field size was in the range of 3 × 3 cm{sup 2} to 4 × 4 cm{sup 2}. Each beam was delivered at perpendicular incidence to the detector plane so as to avoid the need for angular dependence corrections. The fields were measured under the same conditions using Gafchromic EBT3 film for comparison. The film was scanned at 72 dpi resolution, with the red channel data used for analysis. Results: Average gamma passing rates of (92.3 ± 1.8) % for 2%/2mm criteria, and (86.6 ± 2.3) % for 1%/2mm criteria were achieved for MP512, using EBT3 film as the reference distribution. The detector array was able to accurately measure the full-width-at-half-maximum (FWHM), to within (0.77 ± 0.01) mm accuracy when compared to film. The penumbral widths (80%-20%) were measured to within (0.30 ± 0.01) mm accuracy to film. Conclusion: The MP512 is a feasible option for measurement of stereotactic photon fields, with its high density of detection points making it useful for small field applications. The prototype array has demonstrated merit; in the future the development of a larger array detection area would be beneficial for clinical applications.

60 APPLIED LIFE SCIENCES↗

SU-F-T-264: VMAT QA with 2D Radiation Measuring Equipment Attached to Gantry

Purpose: To introduce a method of VMAT QA by 2D measuring device. The 2D device is attached to the gantry throughout measurement duration. This eliminates error caused by the angular dependence of the radiation detectors. Methods: A 2D radiation measuring device was attached to the gantry of linear accelerator. The center of the detector plane was at the isocenter. For each patient plan, two verification plans were created for QA purpose. One was like an ordinary VMAT plan, to be used for radiation delivery. The other is a plan with gantry angle fixed at zero, so the dose distribution as seen by the rotating 2D device. Points above 10% dose threshold were analyzed. Data is in tolerance if it fits within the 3 mm or 3% dose gamma criteria. For each patient, the plan was passed when 95% of all the points in the 2D matrix fit the gamma criteria. The following statistics were calculated: number of patient plans passed, percentage of all points passed, average percentage difference of all points. Results: VMAT QA was performed for patients during one year in our department, and the results were analyzed. All irradiation was with 6 MV photon beam. Each plan has calculated and measured doses compared. After collecting one year’s result, with 81 patient plans analyzed, all (100%) of the plans passed the gamma criteria. Of the points analyzed from all plans, 98.8% of all points passed. Conclusion: This method of attaching a 2D measuring device on the linac gantry proves to be an accurate way for VMAT QA. It is simple to use and low cost, and it eliminates the problem of directional dependence.

60 APPLIED LIFE SCIENCES↗

Determination of optical constants of a biaxially anisotropic film by standard multiangle monochromatic ellipsometry

Possibilities of standard multiangle monochromatic ellipsometry in the determination of parameters of a uniform biaxially anisotropic layer are studied for the case of an arbitrary orientation of the two principal axes in the plane of incidence of the light beam and perpendicularity of the third axis to the plane of incidence. Using numerical simulation, it has been found that the measurement accuracy that is necessary in the determination of all the three principal components of the dielectric permittivity tensor ε and tilt angle of the axes using only angular dependences of ellipsometric parameters must be no worse than 0.0001°, which is far beyond the accuracy limits provided by present-day ellipsometers. If the tilt angle is known, standard multiangle monochromatic ellipsometry provides the determination of thickness and all three principal components of the dielectric permittivity tensor. This method allows one to determine the layer thickness and tensor component for the axis perpendicular to the plane of incidence, as well as the average value of components for the axes lying in the plane of incidence without involving the data about the tilt angle of the axes. This is demonstrated by an example of experimental data for biaxially anisotropic SiO{sub x} films obtained by oblique deposition of silicon monoxide SiO evaporated in vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solution of the inverse problem for reconstructing the real structure of materials from the data of different X-ray methods

A software program has been developed for joint solution of the inverse problem on the basis of the X-ray diffractometry and reflectometry data. A system of basic objects supporting some functions of automatic data flow processing in the program and oriented to mathematical calculations has been created. It is shown by the example of experimental data for an In{sub x}Ga{sub 1-x}As-In{sub y}Al{sub 1-y}As/InP(001) sample that joint fitting of X-ray diffractometry and reflectometry curves makes it possible to reconstruct the model parameters of a multilayer with smaller rms errors. The data were processed taking into account the angular dependences of the background intensity and the aperture factors stemming from the geometry of the experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of strong virtual scattering under three-beam (220, 371) X-ray diffraction in TeO{sub 2} single crystal

A strong effect of virtual scattering has been experimentally observed when studying the nearly coplanar three-beam (220, 371) X-ray diffraction in a paratellurite single crystal under high-resolution double-crystal X-ray diffraction using MoK{sub {alpha}1} radiation. One characteristic feature of this effect is that the angular dependence of the first (strong) reflection intensity and its shape barely change in the three-beam range of parameters, whereas very strong changes are observed for the second (weak) reflection not only in the three-beam range but also far beyond it, which is related to the variation in the two-beam diffraction parameter due to virtual scattering. The changes observed are asymmetric and make it possible to determine the triplet combination of structure-factor phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ordered gold nanostructures on sapphire surfaces: Fabrication and optical investigations

The possibilities of obtaining ordered gold nanoarrays on sapphire surfaces with oriented nanorelief are demonstrated. The structures are morphologically described using atomic force microscopy data. A study of the angular dependence of the reflectivity in the visible range of electromagnetic waves has revealed some features which are likely to indicate surface plasmon-polariton excitation at the air-gold interface under exposure to p-polarized radiation. The experimental results are found to be in good agreement with the theoretical calculations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Model approach to solving the inverse problem of X-ray reflectometry and its application to the study of the internal structure of hafnium oxide films

The key features of the inverse problem of X-ray reflectometry (i.e., the reconstruction of the depth profile of the dielectric constant using an experimental angular dependence of reflectivity) are discussed and essential factors leading to the ambiguity of its solution are analyzed. A simple approach to studying the internal structure of HfO{sub 2} films, which is based on the application of a physically reasonable model, is considered. The principles for constructing a film model and the criteria for choosing a minimal number of fitting parameters are discussed. It is shown that the ambiguity of the solution to the inverse problem is retained even for the simplest single-film models. Approaches allowing one to pick out the most realistic solution from several variants are discussed.

36 MATERIALS SCIENCE↗

Quantum oscillations in dual-layered quasi-two-dimensional organic metal (ET){sub 4}HgBr{sub 4}(C{sub 6}H{sub 4}Cl{sub 2})

The behavior of de Haas–van Alfven (dHvA) and Shubnikov–de Haas (ShdH) quantum oscillations in dual-layered quasi-two-dimensional organic metal (ET){sub 4}HgBr{sub 4}(C{sub 6}H{sub 4}Cl{sub 2}) is investigated. The oscillation spectra qualitatively agree with theoretical calculations of the bandgap structure. The angular dependence of the oscillation amplitude of magnetoresistance contains “spin zeros”; the analysis of the location of these zeros allows one to evaluate the electron–phonon interaction constant: λ ≈ 0.2.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Trinal Nature of the Excitation of Bulk Plasmons by a Fast Charged Particle at Grazing Incidence on the Interface between Vacuum and a Metal with Strong Spatial Dispersion

The excitation and propagation of bulk and surface (surface waves of transition radiation of plasmons at frequencies above the plasma frequency) plasma waves by incident electrons moving both in vacuum toward the surface of a metal and inside the metal whose boundary elastically and spectacularly reflects internal nonequilibrium electrons have been analyzed. In contrast to work [B. N. Libenson, J. Exp. Theor. Phys. 113, 553 (2011)], attention in this work is focused on the influence of surface effects on bulk-plasmon excitation by incident electrons. The probabilities and spectra of single characteristic energy loss of an intermediate- energy electron (50–500 eV) moving at an angle to the surface of the medium in three regions: in vacuum, in the medium, and again in vacuum after the electron leaves the medium are calculated. The kinetic approximation is used for the dielectric function, where the entire range of the plasmon spectrum is taken into account correctly for the problem under consideration. In the indicated energy range of incident electrons, surface effects, on the one hand, significantly reduces the probability of excitation of bulk plasma waves in the medium with strong spatial dispersion, in particular, as compared to the results obtained in [B.N. Libenson, J. Exp. Theor. Phys. 113, 553 (2011)], where surface effects were disregarded and the probability of bulkplasmon excitation by a 200-eV electron incident and emitted perpendicularly to the boundary is about one third of that in the unbounded medium. On the other hand, at grazing incidence from vacuum, the probability of transition radiation of bulk plasmons increases significantly and can lead to a change in the character of the angular dependence of the intensity of bulk plasma energy loss. Thus, the main result of this work is that a decrease in the glancing angle of the fast electron with respect to the vacuum–metal interface is accompanied both by an increase in the contribution from the transition mechanism to the probability of bulk-plasmon excitation in the vacuum region and by a decrease in the contribution from Cherenkov and bremsstrahlung mechanisms of excitation in the medium. The probability of bulk-plasmon excitation in the vacuum region exceeds the probability of excitation at the further motion of the electron in metallic aluminum at angles of incidence larger than 65°, 70°, and 75° at the energies E = 200, 350, and 500 eV, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Differential Cross Section for Elastic Deuteron–Proton Scattering at the Energy of 700 MeV per Nucleon

The results of measurements of the differential cross section for elastic deuteron–proton scattering at the energy of 700 MeV per nucleon that were performed at the internal target station of the nuclotron at the Joint Institute for Nuclear Research (JINR, Dubna) are presented. These data were obtained at angles in the range between 70◦ and 120◦ in the c.m. frame. The angular dependence obtained in this way is compared with world-averaged data at similar energies and with the results of theoretical calculations performed within the relativistic theory of multiple scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin effects in the dd → {sup 3}He n reaction at intermediate energies

The dd → {sup 3}He n reaction is considered at the energies between 200 and 520 MeV. The calculations are performed within relativistic multiple scattering model based on the Alt-Grassberger-Sandhas equations. The angular dependences of the differential cross section and vector and tensor analyzing powers are given in comparison with the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the electrically detected cyclotron resonance of holes in silicon nanostructures

The cyclotron resonance in semiconductor nanostructures is electrically detected for the first time without an external cavity, a source, and a detector of microwave radiation. An ultranarrow p-Si quantum well on an n-Si (100) surface confined by superconducting heavily boron-doped {delta}-shaped barriers is used as the object of investigation and provides microwave generation within the framework of the nonstationary Josephson effect. The cyclotron resonance is detected upon the presence of a microcavity, which is incorporated into the quantum-well plane, by measuring the longitudinal magnetoresistance under conditions of stabilization of the source-drain current. The cyclotron-resonance spectra and their angular dependences measured in a low magnetic field identify small values of the effective mass of light and heavy holes in various 2D subbands due to the presence of edge channels with a high mobility of carriers.

36 MATERIALS SCIENCE↗