Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arcing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Short Arc Orbit Determination for Altimeter Calibration and Validation on TOPEX/Poseidon

TOPEX/Poseidon (T/P) is a joint mission of US NASA and French CNES design launched August 10, 1992. It carries two radar altimeters which alternately share a common antenna. There are two project designated verification sites, a NASA site off the coast at Pt. Conception, CA, and a CNES site near Lampedusa Island in the Mediterranean Sea. Altimeter calibration and validation for T/P is performed over these highly instrumented sites by comparing the spacecraft's altimeter radar range to computed range based on in situ measurements which include the estimated orbit position. This paper presents selected results of orbit determination over each of these sites to support altimeter verification. A short arc orbit determination technique is used to estimate a locally accurate position determination of T/P from less than one revolution of satellite laser ranging (SLR) data. This technique is relatively insensitive to gravitational and nongravitational force modeling errors and is therefore essentially geometrical. The quality of these short arc orbits is demonstrated by covariance analysis and by comparison to orbits determined from longer arcs of data and other tracking data types, such as DORIS and Global Positioning System Demonstration Receiver (GPSDR) data.

radar↗

Analysis of Arc Welding Process in Space

This work is motivated by NASA plans to conduct welding experiments on the ISS. It is expected that deployment of welding and additive manufacturing technologies in the space environment has the potential to revolutionise how orbiting platforms are designed, manufactured, and assembled. However, the structure, composition and quality of a weld is extremely dependent on the environment and can be difficult to control in space. Shielding gases would also be tough to manage as gases behave differently in zero gravity and airless environments. Additional points of concern are related to the spatter and sparks dynamics in space. Therefore, there is a need for a more basic understanding of welding processes by computational modelling. To provide such an insight we developed state of art models of the ARC torch, droplet detachment and transfer, and the melt pool build up using magnetohydrodynamics approximation and level set method for two-phase liquid metal/-gas flow modelling. Two finite element models were built using 2D axisymmetric geometry in COMSOL Multiphysics®: (i) stationary model of the ARC torch and (ii) dynamical model of droplet detachment and transfer. Both models demonstrate reasonable agreement with earlier experimental observations and high sensitivity to the temperature dependence of the thermophysical parameters on the system materials. The models were used to provide physical insight into ARC welding in various environments and geometries. It was shown, in particular, that there is a significant probability of gas bubbles trapping in the meltpool and a possibility of unbounded wondering of sparks in the welding chamber in zero gravity. In addition, we estimated metal evaporation rate that may be hazardous in the confined environment of the ISS. These issues raise concern of quality of the weld and safety for ISS applications.

ARC welding↗

Characterizing Heat Flux in the Miniature Arc Jet Research Chamber (mARC II)

The second-generation miniature Arc jet Research Chamber (mARC II) at NASA Ames Research Center produces small-scale high enthalpy flows relevant for entry systems ground testing. This facility is aimed at applications such as new arc jet flow diagnostics and new arc column diagnostics. The mARC system has previously been shown capable of delivering heat fluxes between 800 and 1900 W/cm2. New work shows that the facility is also capable of delivering heat fluxes as low as 200 W/cm2.

arc jet↗

On Characterization of Flow Disturbances in Arc-Jet Testing

This paper reports computational simulations and analysis of flow characterization tests in high enthalpy arc-jet facilities at NASA Ames Research Center. Flow disturbances and their characterization are presented through case studies, and their implications for testing are discussed. The case studies include free-jet test configurations from three different arc heaters and nozzles: the 60-MW IHF 30-inch conical nozzle, the 10-MW TP3 15-inch conical nozzle, and the 20-MW AHF 12-inch conical nozzle. For all cases, test articles are placed in the jet exiting the conical nozzle, and the existence of a flow disturbance is confirmed through flow survey data using pitot pressure and heat flux probes and accompanying analysis. The paper focuses on cases where the effects of the disturbances on test article surface quantities are important. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzles and test box, including the models tested. Comparisons of computations with the experimental measurements are presented. The computations that reproduce the probe sweep data approximately are essential to interpret the arc-jet test data accurately, while providing insights into several observed calorimeter anomalies caused by flow disturbances.

Arc-jet testing↗

On Characterization of Flow Disturbances in Arc-Jet Testing

This paper reports computational simulations and analysis of flow characterization tests in high enthalpy arc-jet facilities at NASA Ames Research Center. Flow disturbances and their characterization are presented through case studies, and their implications for testing are discussed. The case studies include free-jet test configurations from three different arc heaters and nozzles: the 60-MW IHF 30-inch conical nozzle, the 10-MW TP3 15-inch conical nozzle, and the 20-MW AHF 12-inch conical nozzle. For all cases, test articles are placed in the jet exiting the conical nozzle, and the existence of a flow disturbance is confirmed through flow survey data using pitot pressure and heat flux probes and accompanying analysis. The paper focuses on cases where the effects of the disturbances on test article surface quantities are important. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzles and test box, including the models tested. Comparisons of computations with the experimental measurements are presented. The computations that reproduce the probe sweep data approximately are essential to interpret the arc-jet test data accurately, while providing insights into several observed calorimeter anomalies caused by flow disturbances.

Arc-jet testing↗

Kalman Filtering and RTS Smoothing for Arc-Jet Sample Edge Tracking

Accurate and temporally consistent measurements of test-article recession are required to characterize material response during arc-jet ablation experiments. However, image-based boundary measurements are often affected by segmentation noise, brightness variations, and frame-to-frame variability. This work extends arcjetCV [1] with filtering methods for tracking the evolving boundaries of hemispherical and ISO-Q test articles. Two boundary-tracking approaches based on Kalman filtering [2] were implemented. The first applies a point-wise Kalman filter followed by a Rauch–Tung–Striebel smoother [3] to individual boundary-point locations. The second applies the same filtering and smoothing framework to a reduced set of geometry-dependent shape parameters. The point-wise method reduces local frame-to-frame fluctuations while preserving spatial details along the detected boundary. The shape-parameter method provides a compact and geometrically constrained estimate of the sample contour. Figure 1 illustrates the two approaches for a hemispherical test article. Both methods improve temporal consistency and support more robust estimation of surface recession from arc-jet imagery. The two filtering approaches provide complementary representations of boundary evolution and improve the reliability of image-based recession measurements during arc-jet experiments.

recession measurement↗

Arc Detection and Interlock Module for the PEP II Low Level RF System

A new arc detection and interlock generating module for the SLAC PEP-II low-level RF VXI-based system has been developed. The system is required to turn off the RF drive and high voltage power supply in the event of arcing in the cavity windows, klystron window, or circulator. Infrared photodiodes receive arc signals through radiation resistant optical fibers. Gain and bandwidth are selectable for each channel to allow tailoring response. The module also responds to interlock requests from other modules in the VXI system and communicates with the programmable logic controller (PLC) responsible for much of the low-level RF system's interlock functionality.

43 PARTICLE ACCELERATORS↗

Quarterly Management Document – FY21, 4th Quarter, Multi-pass Hybrid Laser Arc Welding of Alloy 740H

This report summarizes the progress made on reducing the joining time for thick plates of Alloy 740H. Modeling of deep penetration laser welding of Alloy 740H continues with the goal of explaining cracking in the weld that is observed in experimental laser welds in this alloy. Experimental work was also performed to understand factors influencing hybrid laser arc weld quality as a function of the arc and laser parameters. Laser welds and hybrid laser arc welds have been made using best practices up this point in the project. Welded materials have been sent to a commercial vendor to make creep specimens and perform short term creep tests to help evaluate the quality of the welds that have been made so far.

36 MATERIALS SCIENCE↗

Control System Upgrade for Canal ARC SAW

Upgrading the specific components of the Arc Saw, such as the HMI, the components of the chassis involving the I/O modules, servo motor modules, and PLC modules offers numerous advantages. By enhancing the HMI, the operators will benefit having a user-friendly interface, enabling smoother control and monitoring of the ARC SAW’s functionality. Upgrading the modules will contribute to an improved precision and responsiveness in changing modes of the ARC SAW as well as the adjusting the saw blades position, further enhancing the system's overall performance. These upgrades, while maintaining the same functionality, enable the latest technological advancements without needing significant changes or disruptions to existing operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

The Effects of Low Frequency on the Microstructure and Mechanical Properties of High-Strength Al-Mg Aluminum Alloys by Wire and Double-Pulsed Arc Additive Manufacturing

An innovative and high deposition efficiency process, the double-pulsed arc additive manufacturing process, is used to produce high-strength Al-Mg wall components. This dissertation investigates the electrical parameter acquisition, bead appearance, porosity morphology, microstructure and mechanical properties of additively manufactured high-strength Al-Mg wall components and how these are affected by the low frequency of the double-pulsed arc additive manufacturing process. Then, using this process at different low frequencies of 0, 1, 3, 5, 7 and 9 Hz, multilayer deposition experiments were performed. It can be observed that the deposit porosity is obviously eliminated compared with cold metal transfer (CMT) process. The bead appearance of the deposited aluminum wall varies clearly with low frequencies, and at a low frequency of 3 Hz, its appearance is the best of all. The optical observation of microstructure proves that the average grain size varies significantly with low frequency, and at a low frequency of 1 Hz, it is the smallest. In addition, the deposited wall showed maximum mean microhardness and maximum ultimate tensile strength at a low frequency of 3 Hz. Considering the deposited porosity and mechanical priorities, double-pulsed arc additive manufacturing with a frequency of 3 Hz is more suitable for making high-strength Al-Mg wall components than at other low frequencies.

36 MATERIALS SCIENCE↗

Commissioning of Volumetric Modulated Arc Therapy (VMAT)

Purpose: Volumetric modulated arc therapy (VMAT) involves the simultaneous use of dynamic multileaf collimator (DMLC) techniques and gantry arcing; appropriate quality assurance is therefore required. This article describes the development and implementation of procedures for commissioning VMAT on a commercial linear accelerator (Elekta PreciseBeam VMAT with MLCi and Beam Modulator heads). Materials and Methods: Tests for beam flatness and symmetry at the variable dose rates required for VMAT were performed. Multileaf collimator (MLC) calibration was investigated using dynamic prescriptions. The cumulative dose delivered by a sliding window aperture was measured and compared with calculated values. Rotational accuracy was evaluated using dynamic prescriptions which required accurate correlated motion of both gantry and MLC leaves. Finally, measured and calculated dose distributions for complete VMAT treatment plans were compared and evaluated. Results: Beam symmetry was found to be better than 3% down to dose rates of 75 MU/min. MLC calibration provided continuity of dose at match planes of better than 4%, which was comparable to interleaf leakage effects. Integrated sliding window doses were within 3% of those calculated. Tests for rotational accuracy showed uniformity of peripheral dose mostly within {+-}4% of local control point dose, or approximately {+-}0.2% of total central dose. A two-arc prostate case showed an absolute dose difference between calculations and measurements of less than 3%, with gamma (3% and 3 mm) of better than 95%. Conclusions: VMAT has been successfully commissioned and has been introduced into clinical use. The Elekta DMLC has also been shown to be suitable for sliding window delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Intensity-Modulated Arc Therapy for Lymph Node Metastasized Prostate Cancer

Purpose: To determine the planning results and acute toxicity after hypofractionated intensity-modulated arc radiotherapy and androgen deprivation for lymph node metastasized (Stage N1) prostate cancer. Methods and Materials: A total of 31 patients with Stage T1-T4N1M0 prostate cancer were treated with intensity-modulated arc radiotherapy and 3 years of androgen deprivation as primary treatment. The clinical target volume (CTV{sub p}) was the prostate and seminal vesicles. Elective lymph node areas ({sub e}) were delineated and expanded by 2 mm to create the CTV{sub e}. The planning target volumes (PTV{sub p} and PTV{sub e}) were created using a three-dimensional expansion of the CTV{sub p} and CTV{sub e}, respectively, of 7 mm. A median dose of 69.3 Gy and 50 Gy was prescribed to the PTV{sub p} and PTV{sub e} respectively, to be delivered in 25 fractions. Upper and lower gastrointestinal toxicity was scored using the Radiation Therapy Oncology Group toxicity and radiotherapy-induced lower intestinal toxicity scoring system. Genitourinary toxicity was scored using a combined Radiation Therapy Oncology Group, LENT-SOMA (late effects normal tissue-subjective, objective, management, analytic), and Common Toxicity Criteria toxicity scoring system. Results: The median follow-up time was 3 months. The mean prescription dose to the CTV{sub p} and PTV{sub p} was 70.4 Gy and 68.6 Gy, respectively. The minimal dose to the CTV{sub e} and PTV{sub e} was 49.0 Gy and 47.0 Gy, respectively. No acute Grade 2 or greater gastrointestinal toxicity occurred. Fourteen patients developed acute Grade 2 lower gastrointestinal toxicity. Acute Grade 3 and 2 genitourinary toxicity developed in 2 and 14 patients, respectively. Conclusion: The results of our study have shown that hypofractionated intensity-modulated arc radiotherapy as primary therapy for N1 prostate cancer is feasible with low toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Brain Radiotherapy With Simultaneous Integrated Boost to Multiple Brain Metastases Using Volumetric Modulated Arc Therapy

Purpose: Volumetric modulated arc therapy (RapidArc [RA]; Varian Medical Systems, Palo Alto, CA) allows for the generation of intensity-modulated dose distributions by use of a single gantry rotation. We used RA to plan and deliver whole-brain radiotherapy (WBRT) with a simultaneous integrated boost in patients with multiple brain metastases. Methods and Materials: Composite RA plans were generated for 8 patients, consisting of WBRT (20 Gy in 5 fractions) with an integrated boost, also 20 Gy in 5 fractions, to Brain metastases, and clinically delivered in 3 patients. Summated gross tumor volumes were 1.0 to 37.5 cm{sup 3}. RA plans were measured in a solid water phantom by use of Gafchromic films (International Specialty Products, Wayne, NJ). Results: Composite RA plans could be generated within 1 hour. Two arcs were needed to deliver the mean of 1,600 monitor units with a mean 'beam-on' time of 180 seconds. RA plans showed excellent coverage of planning target volume for WBRT and planning target volume for the boost, with mean volumes receiving at least 95% of the prescribed dose of 100% and 99.8%, respectively. The mean conformity index was 1.36. Composite plans showed much steeper dose gradients outside Brain metastases than plans with a conventional summation of WBRT and radiosurgery. Comparison of calculated and measured doses showed a mean gamma for double-arc plans of 0.30, and the area with a gamma larger than 1 was 2%. In-room times for clinical RA sessions were approximately 20 minutes for each patient. Conclusions: RA treatment planning and delivery of integrated plans of WBRT and boosts to multiple brain metastases is a rapid and accurate technique that has a higher conformity index than conventional summation of WBRT and radiosurgery boost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of a New Method for Dynamic Multileaf Collimator Tracking of Prostate Motion in Arc Radiotherapy Using a Single KV Imager

Purpose: To implement a method for real-time prostate motion estimation with a single kV imager during arc radiotherapy and to integrate it with dynamic multileaf collimator (DMLC) target tracking. Methods and Materials: An arc field with a circular aperture and 358 deg. gantry rotation was delivered to a motion phantom with a fiducial marker under continuous kV X-ray imaging at 5 Hz, perpendicular to the treatment beam. A pretreatment gantry rotation of 120 deg. in 20 sec with continuous imaging preceded the treatment. During treatment, each kV image was first used together with all previous images to estimate the three-dimensional (3D) target probability density function and then used together with this probability density function to estimate the 3D target position. The MLC aperture was then adapted to the estimated 3D target position. Tracking was performed with five patient-measured prostate trajectories that represented characteristic prostate motion patterns. Two data sets were recorded during tracking: (1) the estimated 3D target positions, for off-line comparison with the actual phantom motion; and (2) continuous portal images, for independent off-line calculation of the 2D tracking error as the positional difference between the marker and the MLC aperture center in each portal image. All experiments were also made with 1- Hz kV imaging. Results: The mean 3D root-mean-square error of the trajectory estimation was 0.6 mm. The mean root-mean-square tracking error was 0.7 mm, both parallel and perpendicular to the MLC. The accuracy degraded slightly for 1- Hz imaging. Conclusions: Single-imager DMLC prostate tracking that allows arbitrary beam modulation during arc radiotherapy was implemented. It has submillimeter accuracy for most prostate motion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Abdominopelvic Radiotherapy Using Intensity-Modulated Arc Therapy in the Palliative Treatment of Chemotherapy-Resistant Ovarian Cancer With Bulky Peritoneal Disease: A Single-Institution Experience

Purpose: To retrospectively review our experience with whole abdominopelvic radiotherapy (WAPRT) using intensity-modulated arc therapy in the palliative treatment of chemotherapy-resistant ovarian cancer with bulky peritoneal disease. Methods and Materials: Between April 2002 and April 2008, 13 patients were treated with WAPRT using intensity-modulated arc therapy. We prescribed a dose of 33 Gy to be delivered in 22 fractions of 1.5 Gy to the abdomen and pelvis. All patients had International Federation of Gynecology and Obstetrics Stage III or IV ovarian cancer at the initial diagnosis. At referral, the median age was 61 years, and the patients had been heavily pretreated with surgery and chemotherapy. All patients had symptoms from their disease, including gastrointestinal obstruction or subobstruction in 6, minor gastrointestinal symptoms in 2, pain in 4, ascites in 1, and vaginal bleeding in 2. A complete symptom or biochemical response required complete resolution of the patient's symptoms or cancer antigen-125 level. A partial response required {>=}50% resolution of these parameters. The actuarial survival was calculated from the start of radiotherapy. Results: The median overall survival was 21 weeks, with a 6-month overall survival rate of 45%. The 9 patients who completed treatment obtained a complete symptom response, except for ascites (partial response). The median and mean response duration (all symptoms grouped) was 24 and 37 weeks, respectively. Of the 6 patients presenting with obstruction or subobstruction, 4 obtained a complete symptom response (median duration, 16 weeks). Conclusion: WAPRT delivered using intensity-modulated arc therapy offers important palliation in the case of peritoneal metastatic ovarian cancer. WAPRT resolved intestinal obstruction for a substantial period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulated Arc-Based Hypofractionated Stereotactic Radiotherapy for the Treatment of Selected Intracranial Arteriovenous Malformations: Dosimetric Report and Early Clinical Experience

Purpose: To evaluate, with a dosimetric and clinical feasibility study, RapidArc (a volumetric modulated arc technique) for hypofractionated stereotactic radiotherapy treatment of large arteriovenous malformations (AVMs). Methods and Materials: Nine patients were subject to multimodality imaging (magnetic resonance, computed tomography, and digital subtraction angiography) to determine nidus and target volumes, as well as involved organs at risk (optical structures, inner ear, brain stem). Plans for multiple intensity-modulated arcs with a single isocenter were optimized for a fractionation of 25 Gy in 5 fractions. All plans were optimized for 6-MV photon beams. Dose-volume histograms were analyzed to assess plan quality. Delivery parameters were reported to appraise technical features of RapidArc, and pretreatment quality assurance measurements were carried out to report on quality of delivery. Results: Average size of AVM nidus was 26.2 cm{sup 3}, and RapidArc plans provided complete target coverage with minimal overdosage (V{sub 100%} = 100% and V{sub 110%} < 1%) and excellent homogeneity (<6%). Organs at risk were highly spared. The D{sub 1%} to chiasm, eyes, lenses, optic nerves, and brainstem (mean {+-} SD) was 6.4 {+-} 8.3, 1.9 {+-} 3.8, 2.3 {+-} 2.2, 0.7 {+-} 0.9, 4.4 {+-} 7.2, 12.2 {+-} 9.6 Gy, respectively. Conformity index (CI{sub 95%}) was 2.2 {+-} 0.1. The number of monitor units per gray was 277 {+-} 45, total beam-on time was 2.5 {+-} 0.3 min. Planning vs. delivery {gamma} pass rate was 98.3% {+-} 0.9%. None of the patients developed acute toxicity. With a median follow-up of 9 months, 3 patients presented with deterioration of symptoms and were found to have postradiation changes but responded symptomatically to steroids. These patients continue to do well on follow-up. One patient developed headache and seizures, which was attributed to intracranial bleed, confirmed on imaging. Conclusion: Hypofractionated stereotactic radiotherapy can be successfully delivered using the RapidArc form of volumetric arc technology for intracranial AVMs. The quality of delivery and calculated parameters are in agreement with each other and are in line with published reports for other sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Photon Beams of a Flattening Filter-free Linear Accelerator for Hypofractionated Volumetric Modulated Arc Therapy in Localized Prostate Cancer

Purpose: To evaluate the potential usage of flattening filter-free (FFF) photon beams in the treatment of prostate cancer. Methods and Materials: Volumetric-modulated arc therapy (VMAT) treatment planning was performed for 7 patients using TrueBeam{sup Registered-Sign} linear accelerator and photon beams with (X6, X10) and without (X6FFF, X10FFF) flattening filter. Prescribed dose was 19 Multiplication-Sign 3 Gy = 57 Gy. One or two 360 Degree-Sign arcs with dose rate of 600 MU/min for flattened beams, and 1,200 MU/min for FFF beams were used. Results: No difference was detected between the four beams in PTV coverage, conformity, and homogeneity. Mean body dose and body volume receiving 50% of the prescribed dose decreased with increasing mean energy (r{sup 2} = 0.8275, p < 0.01). X6FFF delivered 3.6% more dose compared with the X6 (p < 0.01). X10FFF delivered 3.0% (p < 0.01), and the X10 5.8% (p < 0.01) less mean body dose compared with X6. There was a significant increase in the mean dose to the rectum for the X10 compared with X6 (2.6%, p < 0.01). Mean dose to the bladder increased by 1.3% for X6FFF and decreased by 2.3% for X10FFF. Using a single arc and FFF, treatment time was reduced by 35% (2 SD = 10%). Conclusion: FFF beams resulted in dose distributions similar to flattened beams. X10FFF beam provided the best solution, sparing rectum and bladder and minimizing whole-body dose. FFF beams lead to a time efficient treatment delivery, particularly when combined with hypofractionated VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗