Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Buckling of continuously supported hinged beams

The effect on the buckling load of a hinge at the center of an infinite beam supported by a semiinfinite elastic continuum is analyzed using the complex Fourier transforms. An expression is obtained for the relationship between the surface deflection of the elastic continuum and the pressure distribution acting on the surface, and solutions are obtained for the assumed form of the pressure distribution below the beam. The analysis is applied to cases of uniform pressure over the width of the beam and a pressure distribution that occurs below a rigid stamp. The results show that the buckling loads for an infinite beam with a hinge at the center and supported by a semiinfinite elastic continuum are approximately one half of those for a beam without a hinge, and that this ratio is exactly one half for an infinite beam resting on a Winkler foundation.

Murthy, G. K. N.↗

Angular distributions of reflected and refracted relativistic electron beams crossing a thin planar target at a small angle to its surface

The scattering of electrons by aluminum, copper, and lead foils, as well as by bimetallic aluminum-lead and aluminum-copper foils, has been studied experimentally. A microtron with an energy of particles of 7.4 MeV has been used as a source of electrons. The beam of particles incident on a target at small angles is split into particles reflected from the foil, which constitute a reflected beam, and particles crossing the foil, which constitute a refracted beam. The effect of the material and thickness of the foil, as well as the angle between the initial trajectory of the beam and the plane of the target, on the direction of motion and the angular divergence of the beam crossing the foil and the beam reflected from the foil has been analyzed. Furthermore, the effect of the sequence of metal layers in bimetallic films on the angles of refraction and reflection of the beam has been examined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrostatic beams from tailored plasmas in a Penning-Malmberg trap

In recent work, a technique was developed to extract high quality beams from single-component plasmas confined in a Penning-Malmberg trap in a 4.8 T magnetic field. In this paper, a procedure is developed to extract these beams from the confining magnetic field and then focus them to create especially tailored electrostatic beams. Electron beams are extracted from the field in two stages: they are first transported to a region of reduced field (1 mT), and then taken to zero field with a nonadiabatic, fast extraction. Once in the field-free region, the beams are focused using an Einzel lens. Experimental results and numerical simulations are presented to illustrate the extraction and focusing process. Theoretical expressions are developed to describe the modifications to the relevant beam energy and spatial distributions. Where possible, analytic expressions are presented for the case relevant here of beams with Gaussian radial profiles. Beam emittance considerations are discussed as well as prospects for further development of these techniques. Application of these techniques to provide high-quality positron beams is also discussed.

43 PARTICLE ACCELERATORS↗

High-power green and blue electron-beam pumped surface-emitting lasers using dielectric and epitaxial distributed Bragg reflectors

ZnSe-based electron-beam pumped vertical-cavity surface-emitting lasers for the green (λ = 530 nm) and blue (λ = 462 nm) spectral region have been realized. Structures with and without epitaxial bottom distributed Bragg reflector have been fabricated and characterized. The samples consist of an active region containing 20 quantum wells with a cavity length varying between an optical thickness of 10 λ to 20 λ. The active material is ZnCdSSe in case of the green devices and ZnSe for the blue ones. Room temperature single mode lasing for structures with and without epitaxial bottom mirror with a maximum output power up to 5.9 W (green) and 3.3 W (blue) is achieved, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy distribution measurement of narrow-band ultrashort x-ray beams via K-edge filters subtraction

The characterization of novel x-ray sources includes the measurement of the photon flux and the energy distribution of the produced beam. The aim of BEATS2 experiment at the SPARC-LAB facility of the INFN National Laboratories of Frascati (Rome, Italy) is to investigate possible medical applications of an x-ray source based on Thomson relativistic back-scattering. This source is expected to produce a pulsed quasi-monochromatic x-ray beam with an instantaneous flux of 10{sup 20} ph/s in pulses 10 ps long and with an average energy of about 20 keV. A direct measurement of energy distribution of this beam is very difficult with traditional detectors because of the extremely high photon flux. In this paper, we present a method for the evaluation of the energy distribution of quasi-monochromatic x-ray beams based on beam filtration with K-edge absorbing foils in the energy range of interest (16-22 keV). The technique was tested measuring the energy distribution of an x-ray beam having a spectrum similar to the expected one (SPARC-LAB Thomson source) by using a tungsten anode x-ray tube properly filtered and powered. The energy distribution obtained has been compared with the one measured with a HPGe detector showing very good agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of weakly and strongly diverging ion beams in a magnetically expanding plasma

The spatial distribution of an ion beam created in a magnetically expanding plasma using permanent magnets is experimentally investigated for 0.35 and 1 mTorr, where the magnetic-field strength is about 100 G in the plasma source and is decreasing into a few gauss in the diffusion chamber. The beam profile for 0.35 mTorr is weakly divergent. On the other hand, the strongly diverging beam is detected for 1 mTorr. The results are discussed from the viewpoint of the plasma-potential structures and imply the beam divergence caused by the radial electric fields in the ion acceleration region and the diffusion chamber.

43 PARTICLE ACCELERATORS↗

Correlation of auroral hiss and upward electron beams near the polar cusp

Data were obtained from the DE-1 high-altitude plasma instrument (HAPI) and plasma wave instrument (PWI) during outbound passes through the polar cusp near local noon. The observed distribution functions of electron beams are fitted by drifting Maxwellian functions and the observed distribution functions of hot background electrons by isotropic Maxwellian functions. In addition, the cold plasma density is inferred from knowledge of the electron plasma frequency and the measured density of the warm plasma, including the electron beam distribution. The empirically fitted plasma parameters, including density, temperature and drifting energy, are used to solve the linear dispersion equation for the resulting whistler mode emissions. Because the whistler mode becomes quasi-electrostatic for wave-normal angles near the resonance cone, the electrostatic approximation is used for the whistler mode dispersion relation. The results of wave instability analyses are then compared with the wave observations. A ray tracing of cusp hiss emission is conducted to locate the wave source region (at about one earth-radius).

Lin, C. S.↗

An image filtering technique for SPIDER visible tomography

The tomographic diagnostic developed for the beam generated in the SPIDER facility (100 keV, 50 A prototype negative ion source of ITER neutral beam injector) will characterize the two-dimensional particle density distribution of the beam. The simulations described in the paper show that instrumental noise has a large influence on the maximum achievable resolution of the diagnostic. To reduce its impact on beam pattern reconstruction, a filtering technique has been adapted and implemented in the tomography code. This technique is applied to the simulated tomographic reconstruction of the SPIDER beam, and the main results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature dependence of ion-beam mixing in crystalline and amorphous germanium isotope multilayer structures

Self-atom mixing induced by 310 keV gallium (Ga) ion implantation in crystalline and preamorphized germanium (Ge) at temperatures between 164 K and 623 K and a dose of 1 × 10{sup 15} cm{sup −2} is investigated using isotopic multilayer structures of alternating {sup 70}Ge and {sup nat}Ge layers grown by molecular beam epitaxy. The distribution of the implanted Ga atoms and the ion-beam induced depth-dependent self-atom mixing was determined by means of secondary ion mass spectrometry. Three different temperature regimes of self-atom mixing, i.e., low-, intermediate-, and high-temperature regimes are observed. At temperatures up to 423 K, the mixing is independent of the initial structure, whereas at 523 K, the intermixing of the preamorphized Ge structure is about twice as high as that of crystalline Ge. At 623 K, the intermixing of the initially amorphous Ge structure is strongly reduced and approaches the mixing of the crystalline material. The temperature dependence of ion-beam mixing is described by competitive amorphization and recrystallization processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Remnant break-up and muon production in cosmic ray air showers

We discuss the relation between remnant fragmentation in inelastic high-energy hadronic interactions and muon production in extensive cosmic ray air showers. Using a newly developed tool, a simple and flexible hadronic event generator, we analyze the forward region of hadronic interactions. We show that measurements of the Feynman-x distribution in the beam fragmentation region at LHCf will be key to understanding muon production in air showers quantitatively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-dimensional analytical model for the spatial variation of the foreshock electron distribution function - Systematics and comparisons with ISEE observations

A model which is consistent with the solar wind and shock surface boundary conditions for the foreshock electron distribution in the absence of wave-particle effects is formulated for an arbitrary location behind the magnetic tangent to the earth's bow shock. Variations of the gyrophase-averaged velocity distribution are compared and contrasted with in situ ISEE observations. It is found that magnetic mirroring of solar wind electrons is the most important process by which nonmonotonic reduced electron distributions in the foreshock are produced. Leakage of particles from the magnetosheath is shown to be relatively unimportant in determining reduced distributions that are nonmonotonic. The two-dimensional distribution function off the magnetic field direction is the crucial contribution in producing reduced distributions which have beams. The time scale for modification of the electron velocity distribution in velocity space can be significantly influenced by steady state spatial gradients in the background imposed by the curved shock geometry.

Fitzenreiter, R. J.↗

NUMERICAL SOLUTION FOR THE POTENTIAL AND DENSITY PROFILE OF A THERMAL EQUILIBRIUM SHEET BEAM

In a recent paper, S. M. Lund, A. Friedman, and G. Bazouin, Sheet beam model for intense space-charge: with application to Debye screening and the distribution of particle oscillation frequencies in a thermal equilibrium beam, in press, Phys. Rev. Special Topics - Accel. and Beams (2011), a 1D sheet beam model was extensively analyzed. In this complementary paper, we present details of a numerical procedure developed to construct the self-consistent electrostatic potential and density profile of a thermal equilibrium sheet beam distribution. This procedure effectively circumvents pathologies which can prevent use of standard numerical integration techniques when space-charge intensity is high. The procedure employs transformations and is straightforward to implement with standard numerical methods and produces accurate solutions which can be applied to thermal equilibria with arbitrarily strong space-charge intensity up to the applied focusing limit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NUMERICAL SOLUTION FOR THE POTENTIAL AND DENSITY PROFILE OF A THERMAL EQUILIBRIUM SHEET BEAM

In a recent paper, S. M. Lund, A. Friedman, and G. Bazouin, Sheet beam model for intense space-charge: with application to Debye screening and the distribution of particle oscillation frequencies in a thermal equilibrium beam, in press, Phys. Rev. Special Topics - Accel. and Beams (2011), a 1D sheet beam model was extensively analyzed. In this complementary paper, we present details of a numerical procedure developed to construct the self-consistent electrostatic potential and density profile of a thermal equilibrium sheet beam distribution. This procedure effectively circumvents pathologies which can prevent use of standard numerical integration techniques when space-charge intensity is high. The procedure employs transformations and is straightforward to implement with standard numerical methods and produces accurate solutions which can be applied to thermal equilibria with arbitrarily strong space-charge intensity up to the applied focusing limit.

43 PARTICLE ACCELERATORS↗

In-situ microscale through-silicon via strain measurements by synchrotron x-ray microdiffraction exploring the physics behind data interpretation

In-situ microscale thermomechanical strain measurements have been performed in combination with synchrotron x-ray microdiffraction to understand the fundamental cause of failures in microelectronics devices with through-silicon vias. The physics behind the raster scan and data analysis of the measured strain distribution maps is explored utilizing the energies of indexed reflections from the measured data and applying them for beam intensity analysis and effective penetration depth determination. Moreover, a statistical analysis is performed for the beam intensity and strain distributions along the beam penetration path to account for the factors affecting peak search and strain refinement procedure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-D-BRC-07: System Design for a 3D Volumetric Scintillation Detector Using SCMOS Cameras

Purpose: The purpose of this project is to build a volumetric scintillation detector for quantitative imaging of 3D dose distributions of proton beams accurately in near real-time. Methods: The liquid scintillator (LS) detector consists of a transparent acrylic tank (20×20×20 cm{sup 3}) filled with a liquid scintillator that when irradiated with protons generates scintillation light. To track rapid spatial and dose variations in spot scanning proton beams we used three scientific-complementary metal-oxide semiconductor (sCMOS) imagers (2560×2160 pixels). The cameras collect optical signal from three orthogonal projections. To reduce system footprint two mirrors oriented at 45° to the tank surfaces redirect scintillation light to cameras for capturing top and right views. Selection of fixed focal length objective lenses for these cameras was based on their ability to provide large depth of field (DoF) and required field of view (FoV). Multiple cross-hairs imprinted on the tank surfaces allow for image corrections arising from camera perspective and refraction. Results: We determined that by setting sCMOS to 16-bit dynamic range, truncating its FoV (1100×1100 pixels) to image the entire volume of the LS detector, and using 5.6 msec integration time imaging rate can be ramped up to 88 frames per second (fps). 20 mm focal length lens provides a 20 cm imaging DoF and 0.24 mm/pixel resolution. Master-slave camera configuration enable the slaves to initiate image acquisition instantly (within 2 µsec) after receiving a trigger signal. A computer with 128 GB RAM was used for spooling images from the cameras and can sustain a maximum recording time of 2 min per camera at 75 fps. Conclusion: The three sCMOS cameras are capable of high speed imaging. They can therefore be used for quick, high-resolution, and precise mapping of dose distributions from scanned spot proton beams in three dimensions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-443: Developmental Technique for Proton Pencil Beam Measurements: Depth Dose

Purpose: Measurements of depth dose distribution (DDD) of pencil beam in proton therapy can be challenging and time consuming. We have developed a technique that uses two Bragg peak chambers to expedite these measurements with a high accuracy. Methods and Material: We used a PTW water tank and two PTW 10.5 cm3 Bragg peak chambers; one as a field chamber and the other as a reference chamber to measure DDDs for 100–250 MeV proton pencil beams. The reference chamber was positioned outside of the water tank upstream with respect to field chamber. We used Geant4 Monte Carlo Simulation (MCS) to model the ProTom proton beam to generate DDDs. The MCS generated DDDs were used to account for halo effects of proton pencil beam that are not measureable with Bragg peak chambers. We also used PTW PEAKFINDER to measure DDDs for comparison purpose. Results: We compared measured and MCS DDDs with Continuous Slowing Down Approximation (CSDA) ranges to verify the range of proton beams that were supplied by the manufacturer. The agreements between all DDD with respect to CSDA were within ±0.5 mm. The WET for Bragg peak chamber for energies between 100–250 MeV was 12.7 ± 0.5 mm. The correction for halo effect was negligible below 150 MeV and was in order of ∼5-10% for 150–250 MeV. Conclusion: Use of Bragg Peak chamber as a reference chamber can facilitate DDD measurements in proton pencil beam with a high accuracy. Some corrections will be required to account for halo effect in case of high energy proton beams due to physical size of chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

SU-F-T-473: Evaluation of Off-Axis And Peripheral Dose Using Different Detectors

Purpose: In radiation therapy, measurement of off-axis and peripheral dose is a tedious task. The dose distribution along the beam central axis give only part of the information required for an accurate dose description inside the patient. Dose distributions in 2-D and 3-D are determined with central axis data in conjunction with off-axis dose profiles. Combining a central axis dose distribution with off-axis data results in volume dose matrix that provides 2-D and 3-D information on dose distribution. By considering the importance of these two parameters this study investigates and compares the off axis and peripheral dose measurement using Ionization chamber, MOSFET, Radiochromic film and EDR2 film. Methods: In the measurement of off-axis and peripheral doses 0.6cc farmer type chamber, EDR-2 film, MD-55 radiochromic film and MOSFET detectors were used for both 6MV and 15MV beams. The off-axis and peripheral dose was measured at every 1 cm interval by changing the position of the couch without disturbing the other experimental setup in particular, the phantom with detector position. Results: Readings were obtained for both 6MV and 15MV photon beams at SSD technique for various field size using MOSFET, Ionization chamber and Radiochromic film. The results shows the percentage difference between various detectors for various field sizes. For Peripheral dose measurement were taken from the edge of the field size and for off axis it is measured form central axis dose. Conclusion: In conclusion, our study shows that no detector is ideal and only a comparison between different detectors highlights the weaknesses of each detector. MOSFET provides adequate dose assessment in off-axis and peripheral regions in 6MV and 15MV photon beams. Film dosimetry in general a convenient method to generate one- and two-dimensional dose distributions. The result of this indicates that MOSFET is flexible tool for relative dosimetry as films.

07 ISOTOPE AND RADIATION SOURCES↗