Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cancer models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Lysophosphatidic acid induces reactive oxygen species generation by activating protein kinase C in PC-3 human prostate cancer cells

Highlights: •LPA induces ROS generation through LPA{sub 1} and LPA{sub 3}. •LPA induces ROS generation by activating PLC. •PKCζ mediates LPA-induced ROS generation. -- Abstract: Prostate cancer is one of the most frequently diagnosed cancers in males, and PC-3 is a cell model popularly used for investigating the behavior of late stage prostate cancer. Lysophosphatidic acid (LPA) is a lysophospholipid that mediates multiple behaviors in cancer cells, such as proliferation, migration and adhesion. We have previously demonstrated that LPA enhances vascular endothelial growth factor (VEGF)-C expression in PC-3 cells by activating the generation of reactive oxygen species (ROS), which is known to be an important mediator in cancer progression. Using flow cytometry, we showed that LPA triggers ROS generation within 10 min and that the generated ROS can be suppressed by pretreatment with the NADPH oxidase (Nox) inhibitor diphenylene iodonium. In addition, transfection with LPA{sub 1} and LPA{sub 3} siRNA efficiently blocked LPA-induced ROS production, suggesting that both receptors are involved in this pathway. Using specific inhibitors and siRNA, phospholipase C (PLC) and protein kinase C (PKC) were also suggested to participate in LPA-induced ROS generation. Overall, we demonstrated that LPA induces ROS generation in PC-3 prostate cancer cells and this is mediated through the PLC/PKC/Nox pathway.

60 APPLIED LIFE SCIENCES↗

27-Hydroxycholesterol increases Myc protein stability via suppressing PP2A, SCP1 and FBW7 transcription in MCF-7 breast cancer cells

27-hydroxycholesterol (27-HC), the most abundant metabolite of cholesterol, is a risk factor for breast cancer. It can increase the proliferation of breast cancer cells and promote the metastasis of breast tumours in mouse models. Myc is a critical oncoprotein overexpressed in breast cancer. However, whether 27-HC affects Myc expression has not been reported. In the current study, we aimed to investigate the effects of 27-HC on Myc and the underlying mechanisms in MCF-7 breast cancer cells. Our data demonstrated that 27-HC activated Myc via increasing its protein stability. Three key negative modulators of Myc protein stability, PP2A, SCP1 and FBW7, were suppressed by 27-HC at the transcriptional level. We performed a data-mining analysis of the chromatin immunoprecipitation with next-generation DNA sequencing (ChIP-Seq) data in the ChIPBase, and discovered that a number of putative transcription factors (TFs), including Myc itself, were involved in the transcriptional regulation of PP2A, SCP1 and FBW7. Our results provide a novel mechanistic insight into the activation of Myc by 27-HC via transcriptional repression of PP2A, SCP1 and FBW7 to increase Myc protein stability in breast cancer cells. - Highlights: • 27-Hydroxycholesterol (27-HC) activates Myc via increasing its protein stability. • 27-HC inhibits PP2A and SCP1 transcription to block pS62-Myc dephosphorylation. • 27-HC suppresses FBW7 transcription to prevent pT58-Myc degradation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-667: Radiosensitization Due to Gold Nanoparticles: A Monte Carlo Cellular Dosimetry Investigation of An Expansive Parameter Space

Purpose: To investigate dose enhancement to cellular compartments following gold nanoparticle (GNP) uptake in tissue, varying cell and tissue morphology, intra and extracellular GNP distribution, and source energy using Monte Carlo (MC) simulations. Methods: Models of single and multiple cells are developed for normal and cancerous tissues; cells (outer radii 5–10 µm) are modeled as concentric spheres comprising the nucleus (radii 2.5–7.5 µm) and cytoplasm. GNP distributions modeled include homogeneous distributions throughout the cytoplasm, variable numbers of GNP-containing endosomes within the cytoplasm, or distributed in a spherical shell about the nucleus. Gold concentrations range from 1 to 30 mg/g. Dose to nucleus and to cytoplasm for simulations including GNPs are compared to simulations without GNPs to compute Nuclear and Cytoplasm Dose Enhancement Factors (NDEF, CDEF). Photon source energies are between 20 keV and 1.25 MeV. Results: DEFs are highly sensitive to GNP intracellular distribution; for a 2.5 µm radius nucleus irradiated by a 30 keV source, NDEF varies from 1.2 for a single endosome containing all GNPs to 8.2 for GNPs distributed about the nucleus (7 mg/g). DEFs vary with cell dimensions and source energy: NDEFs vary from 2.5 (90 keV) to 8.2 (30 keV) for a 2.5 µm radius nucleus and from 1.1 (90 keV) to 1.3 (30 keV) for a 7.5 µm radius nucleus, both with GNPs in a spherical shell about the nucleus (7 mg/g). NDEF and CDEF are generally different within a single cell. For multicell models, the presence of gold within intervening tissues between source and target perturbs the fluence reaching cellular targets, resulting in DEF inhomogeneities within a population of irradiated cells. Conclusion: DEFs vary by an order of magnitude for different cell models, GNP distributions, and source energies, demonstrating the importance of detailed modelling for advancing GNP development for radiotherapy. Funding provided by the Natural Sciences and Engineering Council of Canada (NSERC), and the Canada Research Chairs Program (CRC)

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-F-304-05: Cranial TCP/NTCP Modeling Insights and Caveats

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-00: Outcomes of Hypofractionated Treatments - Results of the WGSBRT

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-01: Overview of the Working Group On Stereotactic Body Radiation Therapy (WGSBRT)

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-02: Recurrent HNC Treated with SBRT: TCP-Based Outcome Estimates

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

SU-D-9A-02: Relative Effects of Threshold Choice and Spatial Resolution Modeling On SUV and Volume Quantification in F18-FDG PET Imaging of Anal Cancer Patients

Purpose: PET imaging with F18-FDG is utilized for treatment planning, treatment assessment, and prognosis. A region of interest (ROI) encompassing the tumor may be determined on the PET image, often by a threshold T on the PET standard uptake values (SUVs). Several studies have shown prognostic value for relevant ROI properties including maximum SUV value (SUVmax), metabolic tumor volume (MTV), and total glycolytic activity (TGA). The choice of threshold T may affect mean SUV value (SUVmean), MTV, and TGA. Recently spatial resolution modeling (SRM) has been introduced on many PET systems. SRM may also affect these ROI properties. The purpose of this work is to investigate the relative influence of SRM and threshold choice T on SUVmean, MTV, TGA, and SUVmax. Methods: For 9 anal cancer patients, 18F-FDG PET scans were performed prior to treatment. PET images were reconstructed by 2 iterations of Ordered Subsets Expectation Maximization (OSEM), with and without SRM. ROI contours were generated by 5 different SUV threshold values T: 2.5, 3.0, 30%, 40%, and 50% of SUVmax. Paired-samples t tests were used to compare SUVmean, MTV, and TGA (a) for SRM on versus off and (b) between each pair of threshold values T. SUVmax was also compared for SRM on versus off. Results: For almost all (57/60) comparisons of 2 different threshold values, SUVmean, MTV, and TGA showed statistically significant variation. For comparison of SRM on versus off, there were no statistically significant changes in SUVmax and TGA, but there were statistically significant changes in MTV for T=2.5 and T=3.0 and in SUVmean for all T. Conclusion: The near-universal statistical significance of threshold choice T suggests that, regarding harmonization across sites, threshold choice may be a greater concern than choice of SRM. However, broader study is warranted, e.g. other iterations of OSEM should be considered.

60 APPLIED LIFE SCIENCES↗

SPECT/CT imaging of HER2 expression in colon cancer-bearing nude mice using 125I-Herceptin

Highlights: • {sup 125}I-Herceptin has a high affinity for HER2 in MC38 colon cancer cells. • SPECT imaging of HER2 in colon cancer using {sup 125}I-Herceptin is feasibility. • An effective, non-invasive and less costly in vivo detection method of HER2. An accurate assessment of HER2 status in patients with colorectal cancer is very important, because only the patients overexpressing HER2 can benefit most from the anti-HER2 targeted therapy. In this study, we investigated the feasibility of detecting HER2 expression in colon cancer by SPECT imaging using {sup 125}I-Herceptin, which showed high labeling rate, good in vitro stability and high binding specificity for HER2. HER2-positive mouse colon adenocarcinoma cell line (MC 38) was chosen as the colon caner cell model, and used for the establishment of colon cancer-bearing nude mice model. SPECT/CT imaging suggested that the tumors can be visualized at 12 h after the injection of {sup 125}I-Herceptin, and the uptake of tracer in tumors reached the peak at 24 h after injection, and can be attenuated significantly by pretreatment with an excess of nonlabeled Herceptin. These results indicates that {sup 125}I-Herceptin can be considered as an effective SPECT probe for the non-invasive detection of HER2 expression in colon cancer.

60 APPLIED LIFE SCIENCES↗

Reproductive Factors and Endometrial Cancer Risk Among Women

Despite evidence of an association between reproductive factors and endometrial cancer risk, prospective studies have been conducted mainly in non-Asian countries. To assess the association between reproductive factors, such as number of deliveries, age at menarche, or menopause, and endometrial cancer risk. This cohort study used pooled individual data from 13 prospective cohort studies conducted between 1963 and 2014 in the Asia Cohort Consortium. Participants were Asian women. Data analysis was conducted from September 2019 to April 2023. Reproductive factors were assessed using a questionnaire in each cohort. The main outcome was time to incidence of endometrial cancer. A Cox proportional hazards model was used to calculate hazard ratios (HRs) and 95% CIs.

60 APPLIED LIFE SCIENCES↗

Experimental comparison of grating- and propagation-based hard X-ray phase tomography of soft tissue

When imaging soft tissues with hard X-rays, phase contrast is often preferred over conventional attenuation contrast due its superior sensitivity. However, it is unclear which of the numerous phase tomography methods yields the optimized results at given experimental conditions. Therefore, we quantitatively compared the three phase tomography methods implemented at the beamline ID19 of the European Synchrotron Radiation Facility: X-ray grating interferometry (XGI), and propagation-based phase tomography, i.e., single-distance phase retrieval (SDPR) and holotomography (HT), using cancerous tissue from a mouse model and an entire heart of a rat. We show that for both specimens, the spatial resolution derived from the characteristic morphological features is about a factor of two better for HT and SDPR compared to XGI, whereas the XGI data generally exhibit much better contrast-to-noise ratios for the anatomical features. Moreover, XGI excels in fidelity of the density measurements, and is also more robust against low-frequency artifacts than HT, but it might suffer from phase-wrapping artifacts. Thus, we can regard the three phase tomography methods discussed as complementary. The application will decide which spatial and density resolutions are desired, for the imaging task and dose requirements, and, in addition, the applicant must choose between the complexity of the experimental setup and the one of data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-645: Dose Enhancement to Cell Nucleus Due to Hard Collisions of Protons with Electrons in Gold Nanospheres

Purpose: The purpose of this study was to investigate the theoretical dose enhancement to a cell nucleus due to increased fluence of secondary electrons when gold nanospheres are present in the cytoplasm during proton therapy. Methods: We modeled the irradiation of prostate cancer cells using protons of variable energies when 10,000 gold nanoparticles, each with radius of 10 nm, were randomly distributed in the cytoplasm. Using simple analytical equations, we calculated the increased mean dose to the cell nucleus due to secondary electrons produced by hard collisions of 0.1, 1, 10, and 100 MeV protons with orbital electrons in gold. We only counted electrons with kinetic energy higher than 1 keV. In addition to calculating the increase in the mean dose to the cell nucleus, we also calculated the increase in local dose in the “shadow,” i.e., the umbra, of individual gold nanospheres due to forward scattered electrons. Results: For proton energies of 0.1, 1, 10, and 100 MeV, we calculated increases to the mean nuclear dose of 0.15, 0.09, 0.05, and 0.04%, respectively. When we considered local dose increases in the shadows of individual gold spheres, we calculated local dose increases of 5.5, 3.2, 1.9, and 1.3%, respectively. Conclusion: We found negligible, less than 0.2%, increases in the mean dose to the cell nucleus due to electrons produced by hard collisions of protons with electrons in gold nanospheres. However, we observed increases up to 5.5% in the local dose in the shadow of gold nanospheres. Considering the shadow radius of 10 nm, these local dose enhancements may have implications for slightly increased probability of clustered DNA damage when gold nanoparticles are close to the nuclear membrane.

60 APPLIED LIFE SCIENCES↗

Sci—Fri PM: Dosimetry—04: Radiation out-of-field dose in the treatment of pediatric central nervous system malignancies

Children diagnosed with central nervous system (CNS) malignancies often receive radiotherapy, which can cause radiogenic late effects. In order to identify and reduce the risk of these late effects, we must understand the radiation doses that these children receive. Modern treatment planning systems accurately estimate the absorbed dose within the treatment fields but poorly estimate the dose outside them. The purpose of our study was to measure the out-of-field dose for children receiving localized radiotherapy for CNS cancer and apply an analytical model for estimating dose as a function of distance from the field edge. Radiation fields designed for a 12-year-old boy treated in our clinic were applied to an anthropomorphic phantom containing more than 200 thermoluminescent dosimeters. A double-Gaussian function of absorbed dose versus distance from the field edge (i.e., 50% isodose line) was applied, and parameters were allowed to vary and were fit to the model by minimizing the root mean square deviation, RMSD. The fitted model accurately predicted the dose from distances of 4 cm to 50 cm (RMSD = 0.54 cGy/Gy), but the model was not useful in estimating dose for distances less than 4 cm because of wide variation in measured dose, and the double-Gaussian model failed by systematically underestimating the dose beyond 50 cm. In conclusion, the double-Gaussian model may be applicable for points at distances from the field edge between 4 cm and 50 cm, where most children's radiosensitive tissues are located, but for points beyond 50 cm, an improvement should be investigated.

60 APPLIED LIFE SCIENCES↗

PNNL-CompBio/coderdata

Automation scripts and benchmark dataset package for cancer drug prediction deep learning models.

Gosline, Sara JC [Pacific Northwest National Labor↗

Super-resolution and segmentation deep learning for breast cancer histopathology image analysis

Traditionally, a high-performance microscope with a large numerical aperture is required to acquire high-resolution images. However, the images’ size is typically tremendous. Therefore, they are not conveniently managed and transferred across a computer network or stored in a limited computer storage system. As a result, image compression is commonly used to reduce image size resulting in poor image resolution. Here, we demonstrate custom convolution neural networks (CNNs) for both super-resolution image enhancement from low-resolution images and characterization of both cells and nuclei from hematoxylin and eosin (H&E) stained breast cancer histopathological images by using a combination of generator and discriminator networks so-called super-resolution generative adversarial network-based on aggregated residual transformation (SRGAN-ResNeXt) to facilitate cancer diagnosis in low resource settings. The results provide high enhancement in image quality where the peak signal-to-noise ratio and structural similarity of our network results are over 30 dB and 0.93, respectively. The derived performance is superior to the results obtained from both the bicubic interpolation and the well-known SRGAN deep-learning methods. In addition, another custom CNN is used to perform image segmentation from the generated high-resolution breast cancer images derived with our model with an average Intersection over Union of 0.869 and an average dice similarity coefficient of 0.893 for the H&E image segmentation results. Finally, we propose the jointly trained SRGAN-ResNeXt and Inception U-net Models, which applied the weights from the individually trained SRGAN-ResNeXt and inception U-net models as the pre-trained weights for transfer learning. The jointly trained model’s results are progressively improved and promising. We anticipate these custom CNNs can help resolve the inaccessibility of advanced microscopes or whole slide imaging (WSI) systems to acquire high-resolution images from low-performance microscopes located in remote-constraint settings.

60 APPLIED LIFE SCIENCES↗