Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗

A comparative experimental study of the hygroscopic and mechanical behaviors of electrospun nanofiber membranes and solution–cast films of polybenzimidazole

This article reports a comparative experimental study of the hygroscopic and mechanical behaviors of electrospun polybenzimidazole (PBI) nanofiber membranes and solution-cast PBI films. As-electrospun nonwoven PBI nanofiber mats (with the nanofiber diameter of ~250 nm) were heat-pressed under controlled temperature, pressure and duration for the study; lab-made solution-cast PBI films and commercially available PBI films (the PBI Performance Product Inc., Charlotte, NC) were used as the control samples. Thermogravimetric and microtensile tests were utilized to characterize the hygroscopic (moisture absorption) and mechanical properties of the PBI nanofiber membranes at varying heat-pressing conditions, which were further compared to those of solution-cast PBI films. Experimental results indicated that the PBI nanofiber membranes carried slightly higher thermal stability and less hygroscopic properties than those of solution-cast PBI films. In addition, heat-pressing conditions significantly influenced the mechanical properties of the resulting PBI nanofiber membranes. The stiffness and tensile strength increase with increasing either the heat-pressing pressure or duration, and relevant mechanisms were explored. Here, the present study provides a rational understanding of the hygroscopic and mechanical behaviors of electrospun PBI nanofiber membranes and solution-cast PBI films that are beneficial to their reliable cutting-edge applications in high-temperature filtration, polymer electrolyte membranes (PEMs), etc.

25 ENERGY STORAGE↗

Postoperative radiotherapy following mastectomy for patients with left-sided breast cancer: A comparative dosimetric study

The purposes of this article were to compare the biophysical dosimetry for postmastectomy left-sided breast cancer using 4 different radiotherapy (RT) techniques. In total, 30 patients with left-sided breast cancer were randomly selected for this treatment planning study. They were planned using 4 RT techniques, including the following: (1) 3-dimensional conventional tangential fields (TFs), (2) tangential intensity-modulated therapy (T-IMRT), (3) 4 fields IMRT (4F-IMRT), and (4) single arc volumetric-modulated arc therapy (S-VMAT). The planning target volume (PTV) dose was prescribed 50 Gy, the comparison of target dose distribution, conformity index, homogeneity index, dose to organs at risk (OARs), tumor control probability (TCP), normal tissue complication probability (NTCP), and number of monitor units (MUs) between 4 plans were investigated for their biophysical dosimetric difference. The target conformity and homogeneity of S-VMAT were better than the other 3 kinds of plans, but increased the volume of OARs receiving low dose (V{sub 5}). TCP of PTV and NTCP of the left lung showed no statistically significant difference in 4 plans. 4F-IMRT plan was superior in terms of target coverage and protection of OARs and demonstrated significant advantages in decreasing the NTCP of heart by 0.07, 0.03, and 0.05 compared with TFs, T-IMRT, and S-VMAT plan. Compared with other 3 plans, TFs reduced the average number of MUs. Of the 4 techniques studied, this analysis supports 4F-IMRT as the most appropriate balance of target coverage and normal tissue sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural origin of high‐strength Tyranno SA4 SiC fiber studied by comparative Raman spectroscopy #

Tyranno SA4 grade SiC fiber is an emerging continuous fiber with excellent mechanical properties. The origin of the fiber's high-performance was studied by comparative Raman spectroscopy of four different grades of SiC fibers and reference SiC monolith. Analysis of the Raman spectra of fiber cross-sections, surface and homogeneity, and fibers under stress, revealed how differences in microstructure, such as crystalline order, size, and the presence of critical flaws, dictate mechanical properties. In conclusion, this information can help optimize SiC fiber manufacturing.

36 MATERIALS SCIENCE↗

Hierarchical microstructural parameters governing electrical and thermal conductivity in Al-based eutectic systems

Enhancing conductivity properties of aluminum alloys can drive superior performance and efficiency across diverse engineering applications, yet currently commercially available Al casting alloys are severely limited in electrical and thermal conductivity. There is a general understanding that the presence of any defects and alloying elements within Al will inevitably lower conductivity properties. However, there is a lack of comparative studies evaluating the intricate interplay between the microstructural parameters and conductivity properties across cast Al-based eutectic systems. Therefore, this study bridges this gap by conducting a comparative study across hypoeutectic alloy compositions consisting of 50 % primary Al and 50 % eutectic region to elucidate the key parameters that dictate conductivity properties. This research contributes to advancing the understanding of alloy design opportunities for high conductivity, high strength castable Al alloys.

36 MATERIALS SCIENCE↗

Design study and comparative evaluation of JSFR failed fuel detection system

A conceptual design study of an advanced sodium-cooled fast reactor JSFR has progressed in the 'Fast Reactor Cycle Technology Development (FaCT) 'project in Japan. JSFR has two failed fuel detection systems in the core. One is a failed fuel detection (FFD) system which continuously monitors a fission product from failed fuel subassembly. The other is a failed fuel detection and location (FFDL) system which locates when it receives signals from FFD. The FFD system consists of a FFD-DN which detects delayed neutron (DN) in sodium and a FFD-CG which detects fission products in the cover gas of the reactor vessel. In this study, requirements to the FFD-DN and the FFD-DN design to meet the requirements were investigated for the commercial and demonstration JSFR. In the commercial JSFR, a sampling type FFD which collects sodium from the reactor vessel by sampling lines for DN detectors was adopted. The performances have been investigated and confirmed by a fluid analysis in the reactor upper plenum. In the demonstration JSFR, the performance of DN detectors installed on the primary cold-leg piping has been confirmed. For the FFDL systems, experiences in the previous fast reactors and the R and D of FFDL system for JSFR were investigated. This study focuses on the Selector-Valve and the Tagging-Gas FFDL systems. Operation experiences of the Selector-valve FFDL system were accumulated in PFR and Phenix. Tagging-gas system experiences were accumulated in EBR-II and FFTF. The feasibility of both FFDL systems for JSFR was evaluated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparative experimental study of heat transfer processes in accumulation energy recovery exchangers

In this study, an experimental comparison between three different energy accumulating ceramic heat exchangers for energy recovery in ventilation systems was presented. The units were selected to represent three different approaches on the energy recovery process: honeycomb structure with more accumulation mass (more energy can be stored in one unit)- Unit 1.1, honeycomb structure with lower accumulation mass- Unit 1.2, and a rectangular structure with expanded heat transfer surface- Unit 1.3. The achieved results are useful for the future application of such units in ventilation systems. It was established that all evaluated units demonstrated an acceptable effectiveness of thermal energy recovery from the exhaust air. Their average energy recovery efficiency ranged between 70 % and 80 %, aligning with expected performance benchmarks for regenerative heat exchangers employed in contemporary mechanical ventilation systems. It was also established that the factor which has the highest impact on thermal effectiveness is the heat transfer surface available in the tested heat exchangers. Units with the highest number of channels (i.e., with the highest amount of single channel walls, which can be used for heat transfer) achieve the highest thermal effectiveness. However, higher thermal effectiveness can negatively affect the ventilation potential of the units. Unit 1.3, which was characterized by the highest thermal efficiency, was also characterized by the lowest achievable flow rate. It was also found that the important technical aspect that should be taken into account when analyzing accumulation energy recovery units is also the fluctuation of the supply air temperature. The ability to ensure minimal temperature fluctuations is a significant operational advantage, as it ensures a higher level of safety at lower outside temperatures.

Energy recovery↗

Reproducibility of the cutoff probe for the measurement of electron density

Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparative experimental study of IOR potential in fractured shale reservoirs by cyclic water and nitrogen gas injection

Oil production from tight and shale formations accounted for more than half of total U.S. oil production in 2015 (EIA, 2016). Such amount is expected to grow significantly as the active development of low permeability reservoirs continues. Since the primary recovery is becoming less effective and large amounts of oil are locked in matrix, IOR techniques should be considered to face such challenge. Many recent studies have evaluated the potential of gas injection in shale plays. However, few studies discussed the feasibility of water huff-n-puff process. Here this study evaluated the potential of cyclic water injection (CWI) in shale plugs and compared it with the performance of cyclic gas injection (CGI). Eagle Ford core samples were used in this study and saturated with dead shale oil. X-ray diffraction (XRD) technique was employed to analyze the mineral composition of the sample. To reduce clay swelling, 5 wt% of potassium chloride (KCl) solution was used as the injection fluid in CWI tests. Two groups of experiments were performed to examine the effects of soaking time and injection pressure (Pin) on the recovery performance. For one cycle of huff-n-puff, after reaching the Pin, the core plug was soaked with water for a certain time, then the surrounding pressure was released to enter the production period. Under the same operating conditions, CGI tests were conducted to compare the two IOR performances. The CWI experimental results show that soaking time affects the recovery factor (RF) of a single cycle within a certain range, which was similarly concluded from the CGI tests. Injection pressure can affect the recovery performance of CWI significantly. For example, after performing 12 cycles of water huff-n-puff, the RF for tests with Pin of 1000 psi and 5000 psi were 14% and 21%, respectively. When applying 5000 psi, fractures were created on the plug and the size enlarged with further cycles operated. Comparing the two processes of CWI and CGI, different recovery characters can be observed. CWI showed the recovery potential at the first four cycles, and then the incremental oil recovery decreased dramatically in the subsequent cycles. By contrast, CGI presented a more continuous and steady recovery performance with high incremental RF, and then gradually diminished after seven cycles of huff-n-puff processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecule-Adsorbed Topological Insulator and Metal Surfaces: A Comparative First-Principles Study

We compare electronic structure characteristics of three different kinds of benzene-adsorbed (111) surfaces: that of Bi 2 Te 3 , a prototypical topological insulator, that of Au, a prototypical inert metal, and that of Pt, a prototypical catalytic metal. Using first-principles calculations based on dispersion-corrected density functional theory, we show that benzene is chemisorbed on Pt, but physisorbed on Au and Bi 2 Te 3 . Here, the adsorption on Bi 2 Te 3 is particularly weak, consistent with a minimal perturbation of the electronic structure at the surface of the topological insulator, revealed by a detailed analysis of the interaction of the molecular orbitals with the topological surface states.

36 MATERIALS SCIENCE↗

Role of low-energy ion irradiation in the formation of an aluminum germanate layer on a germanium substrate by radical-enhanced atomic layer deposition

Radical-enhanced atomic layer deposition uses oxygen radicals generated by a remote microwave-induced plasma as an oxidant to change the surface reactions of the alternately supplied trimethylaluminum precursor and oxygen radicals on a Ge substrate, which leads to the spontaneous formation of an aluminum germanate layer. In this paper, the effects that low-energy ions, supplied from a remote microwave plasma to the substrate along with the oxygen radicals, have on the surface reactions were studied. From a comparative study of aluminum oxide deposition under controlled ion flux irradiation on the deposition surface, it was found that the ions enhance the formation of the aluminum germanate layer. The plasma potential measured at the substrate position by the Langmuir probe method was 5.4 V. Assuming that the kinetic energy of ions arriving at the substrate surface is comparable to that gained by this plasma potential, such ions have sufficient energy to induce exchange reactions of surface-adsorbed Al atoms with the underlying Ge atoms without causing significant damage to the substrate. This ion-induced exchange reaction between Al and Ge atoms is inferred to be the background kinetics of the aluminum germanate formation by radical-enhanced atomic layer deposition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A COMPARATIVE ASTROCHEMICAL STUDY OF THE HIGH-MASS PROTOSTELLAR OBJECTS NGC 7538 IRS 9 AND IRS 1

We report the results of a spectroscopic study of the high-mass protostellar object NGC 7538 IRS 9 and compare our observations to published data on the nearby object NGC 7538 IRS 1. Both objects originated in the same molecular cloud and appear to be at different points in their evolutionary histories, offering an unusual opportunity to study the temporal evolution of envelope chemistry in objects sharing a presumably identical starting composition. Observations were made with the Texas Echelon Cross Echelle Spectrograph, a sensitive, high spectral resolution (R {lambda}/{Delta}{lambda} {approx_equal} 100,000) mid-infrared grating spectrometer. Forty-six individual lines in vibrational modes of the molecules C{sub 2}H{sub 2}, CH{sub 4}, HCN, NH{sub 3}, and CO were detected, including two isotopologues ({sup 13}CO, {sup 12}C{sup 18}O) and one combination mode ({nu}{sub 4} + {nu}{sub 5} C{sub 2}H{sub 2}). Fitting synthetic spectra to the data yielded the Doppler shift, excitation temperature, Doppler b parameter, column density, and covering factor for each molecule observed; we also computed column density upper limits for lines and species not detected, such as HNCO and OCS. We find differences among spectra of the two objects likely attributable to their differing radiation and thermal environments. Temperatures and column densities for the two objects are generally consistent, while the larger line widths toward IRS 9 result in less saturated lines than those toward IRS 1. Finally, we compute an upper limit on the size of the continuum-emitting region ({approx}2000 AU) and use this constraint and our spectroscopy results to construct a schematic model of IRS 9.

79 ASTRONOMY AND ASTROPHYSICS↗

Whole breast and excision cavity radiotherapy plan comparison: Conformal radiotherapy with sequential boost versus intensity-modulated radiation therapy with a simultaneously integrated boost

A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy in 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images. Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA values as well as patients’ survival are warranted.

60 APPLIED LIFE SCIENCES↗

Osteogenic differentiation of human adipose derived stem cells on chemically crosslinked carbon nanomaterial coatings

Abstract Carbon nanomaterial coatings have been widely investigated for many biomedical applications including bone tissue engineering. Current methods to fabricate carbon nanomaterial coatings are limited by specific substrate requirements and the lack of strong bonds between the nanomaterials. Furthermore, few studies compare the effect of carbon nanoparticle architecture on stem cell differentiation and mineralization for osteogenic differentiation. Herein, we report a study comparing chemically crosslinked carbon nanotubes (of various diameters), graphene nanoplatelets, and graphene nanoribbons coatings for adipose derived stem cell differentiation toward an osteogenic lineage. We observed greatest autodeposition of calcium on graphene nanoribbon surfaces, while multiwalled carbon nanotubes of high diameter had the greatest influence on stem cell fate (by alkaline phosphatase activity, calcium deposition, and osteocalcin measurements). Studies indicate the cause for multiwalled carbon nanotube related stem cell differentiation, may be related to early timepoint toxicity as indicated by lactose dehydrogenase release. These results indicate suggestions for orthopedic tissue engineering applications for carbon nanomaterial coatings. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1189–1199, 2018.

Patel, Sunny C.↗

Liquid–Liquid Mixing Studies in Annular Centrifugal Contactors Comparing Stationary Mixing Vane Options

Comparative studies of multiphase operation of annular centrifugal contactors showing the impact of housing stationary mixing vane configuration. A number of experimental results for several different mixing vane options are reported with selected measurements in a lab-scale 5 cm contactor and 12.5 cm engineering-scale unit. Fewer straight vanes give greater mixingzone hold-up compared to curved vanes. Quantitative comparison of droplet size distribution also showed a significant decrease in mean diameter for four straight vanes versus eight curved vanes. This set of measurements gives a compelling case for careful consideration of mixing vane geometry when evaluating hydraulic operation and extraction process efficiency of annular centrifugal contactors.

Wardle, Kent E.↗

A Comparative Observational Study of YSO Classification in Four Small Star-forming H ii Regions

We have developed a new young stellar object (YSO) identification and classification technique using mid-infrared Wide-field Infrared Survey Explorer (WISE) data. We compare this new technique with previous WISE YSO detection and classification methods that used either infrared colors or spectral energy distribution slopes. In this study, we also use the new technique to detect and examine the YSO population associated with four small H ii regions: KR 7, KR 81, KR 120, and KR 140. The relatively simple structure of these regions allows us to effectively use both spatial and temporal constraints to identify YSOs that are potential products of triggered star formation. We are also able to identify regions of active star formation around these H ii regions that are clearly not influenced by the H ii region expansion, and thus demonstrate that star formation is on-going on megayear timescales in some of these molecular clouds.

79 ASTRONOMY AND ASTROPHYSICS↗